Mechanical Smoke Extract Shaft Systems

Similar documents
technical specification smoke venting systems

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

SHEVTEC Extended Travel Distance. System for Chettles Yard, Nottingham

Smoke Control in Apartment Buildings. Smoke Control

Prescriptive Requirement for Smoke Control

Uniclass L7535: N3253 EPIC L13:Y42. CI/SfB (57) X (K5) Residential Smoke Ventilation

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Mechanical smoke ventilation systems. CI/SfB 37.4 Xy

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

V3 Intelligent Damper Control and Monitoring System

22 BISHOPSGATE Lift Evacuation Strategy

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Design of Fire safety in Multi Occupancy Residential Accommodation

PASSIVE FIRE PROTECTION GETTING IT RIGHT

Fire Risk Assessment

Fire Risk Assessment

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

Fire Risk Assessment

Uniclass L7535 EPIC L13. CI/SfB (57) X. secontrols.com. Smoke Ventilation, Natural Ventilation and Window Automation

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

Fire Risk Assessment

Smoke Vents. Certified to CE EN Roof Access Systems

BUILDING FIRE STRATEGY (Operational & Fire Engineering Information)

30 top tips to tackle HVAC challenges No.21 - Fireman s override

Technical reference Reference & design

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Kensington Aldridge Academy, London W10

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

FORMULATION OF FIRE SAFETY REQUIREMENTS FOR NEW RAILWAY INFRASTRUCTURES

Case Study of Underground Car Park. Team Japan

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Smoke Control Requirements for New Railway Infrastructure. Ir Peter Law

Fire Risk Assessment. Index. Part 1 Introduction Part 2 The Fire Risk Assessment Part 3 The Management Action Plan

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

Fire protection documentation. CFPA-E Guideline No 13:2015 F

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Colt ventilation systems for car parks, loading bays and service areas

CHAPTER 7 MECHANICAL VENTILATION AND SMOKE CONTROL SYSTEMS 7.1 AIR CONDITIONING & MECHANICAL VENTILATION SYSTEMS

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

Firefighting operations on fire control centres F5-09 GD

Element C3.5 Means of Escape

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Top tip No. 21 Fireman s override

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

BUILDING FIRE STRATEGY

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

General Principles of Smoke Control

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

Fire Engineering in High Rise 15 November 2013

ctbuh.org/papers Fire Engineering the Tallest Building in the Historic City of Manchester, UK Title:

Smoke extract fan SMHA HATCH

LYHA Fire Safety Policy

Smoke Vent Control Panel PCB4 V4 Installation Manual

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

- CONSTRUCTION FIRE SAFETY STANDARDS

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED

IFE Level 5 Diploma in Fire Engineering Design

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

FIRE AND SECURITY CONSULTING SERVICES

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Smoke Master SMPA Compact pressurisation system

Fire Safety Policy Date: 0

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

INTEGRATED LIFE SAFETY COMPLIANCE TESTING AND ITS PROCEDURES

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

Smoke Management in High-Rise Structures

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Handout Notes Major changes in BS : 2016

Cladding Screening Test Result

Fire Safety Management Audit Specification August 2017

Specialist Fire Safety Courses Xact Consultancy and Training Limited

Specialist Fire Safety Courses Xact Consultancy and Training Limited

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

The Social Accountability International (SAI) Fire Safety Checklist

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Actionpac LNS3 Intelligent Damper Control and Monitoring System

FIRE RISK ASSESSMENT. Hatton House. Page 1 of 21

Your specialist partner for total electrical compliance. Electrical Testing

Technical Information

Fire Risk Assessment 2017

New Fire Safety Order

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

Transcription:

Mechanical Smoke Extract Shaft Systems Presented by

Mechanical Smoke Extract Shaft Systems Why Choose Crossflow? Crossflow is a family run company with over 45 years technical expertise. We are a solutions provider offering a wide range of specialised products and are proud to be partners with manufacturers and suppliers throughout Europe who are innovate market leaders in our field. We provide a turnkey package, designed, installed and commissioned by experienced and professional engineers who are specifically trained in all aspects of our products. Our aim as a Ventilation Specialist is to provide a Smoke Ventilation Solution for individual projects that is reliable effective and code compliant. A system that exceeds building regulations whilst satisfying architectural and fire engineering requirements. Regulation Legislation that describes the national guidance on fire safety in new buildings of every kind. BS 9991: 2015 Fire Safety in Design, Management and use of Residential Buildings and BS 9999: 2017 Fire Safety in Design, Management and use of Building both of these two documents give a more detailed designed requirement than TGD-B 2006. BS 9991 is relevant to residential buildings/ accommodation (excluding hotels) whilst BS 9999 relates to commercial buildings covering the four main areas that influence Fire Safety measures namely : Fire safety management The provisions of means of escape The structural protection of escape facilities and the structural stability of the building in the event of a fire The provision of access and facilities for fire fighting. Smoke Control Association (SCA) Guidance on Smoke Control to Escape Routes in Apartment Buildings (Flats & Maisonettes) this document provides guidance on design parameters for smoke control systems in apartment buildings and recommends design calculations for CFD models/simulations. Where are Smoke Shafts used? Protected corridors where compartment travel distance exceeds maximum distance and when external ventilation is not possible. Regulation Requirements for Heat and Smoke Control Regulation Requirements: Fire Fighting Shafts should be designed and installed in accordance with a number of legislative requirements: Technical Guidance Document B 2006 (Fire Safety): This is the primary piece of Building Protected lobby ventilation for all small residential buildings where lobby travel distances exceed 4.5m and when external ventilation is not possible. Protected lobby ventilation as part of a fire fighting shaft, where the top floor is over 18m from ground level or 20m in TGD-B and when external ventilation is not possible.

Types of Smoke Shafts BRE Shaft 3.0 m 2 cross sectional area naturally ventilated tested by British Research Establishment to 101 storeys. Naturally Ventilated Shaft minimum of 1.5m 2 area smaller version of the BRE Shaft Maximum aspect ratio 2:1 which means smallest dimension must be more than 850mm. Suitable where space is limited. Mechanical Shaft any size but generally > 0.6m 2 area. Suitable where space is limited. Consists of mechanical fans to assist extraction of smoke, at the same volumetric rate as a BRE Shaft. by the Smoke Control Association (SCA) 2015. 4. This should allow evacuation of all occupants and safe access for fire fighters through the stair core. Conditions are considered tenable when visibility towards normal objects is greater than 10m. Furthermore temperatures should be below 60 o C @ 2m above the floor and temperature of the smoke layer should remain lower than 200 o C (radiation intensity <2.5 kw / m 2 ). System Description 1. A In multi-storey buildings, the main escape route is via a common corridor and or lobbies or a protected stairs. B In the event of a fire, smoke can easily spread from the fire compartment and quickly fill corridors/lobby during evacuation phase with doors opening for a short period of time, making escape difficult for occupants. C Smoke entering the stairs can also make escape difficult for occupants/residents on higher levels. 2. BS9991 Three types of systems have been mentioned in order to achieve the required ventilation, namely a pressurisation system, a mechanical smoke ventilation system or a natural smoke ventilation system. 3. Crossflow has designed and developed a mechanical smoke shaft ventilation system specifically for firefighting stair cores to provide an equivalence or better than a natural smoke shaft ventilation system as specified in BS 9999, BS 9991, TGD-B 2006 and is compliant with recommendations and guidance provided Plan Drawing Smoke Shaft construction is typically formed from either a fire resistant shaft board, double thickness plaster board, blockwork or concrete. The Smoke Shaft should be sized at no less than 0.6m 2 with an aspect ratio of no greater than 2:1 and have a maximum pressure drop of 50 Pa between highest and lowest point. The shaft should be predominately straight, vertical, fire rated to match the building requirements and well sealed against air leakage with a maximum leakage rate of 3.8m 3 /L/m 2 @ 50 Pa pressure differences. This is to be tested and verified by the main contractor. The shaft is connected to each protected lobby with a 60 mins fire rated damper at high level tested and certified to BSEN 12101-8.

Mechanical Smoke Extract Shaft Systems Air inlet is provided via the stairs from the final exit door and a ventilator/aov at the head of the stairs. No air inlet is required at the base of the shaft. A pressure differential switch is located at each level to monitor the Pa difference between the lobby and stairs. A fireman override switch is located on each level in the stair core. Section Drawing On detection of smoke in the lobby the fire alarm signals the Crossflow System Control Panel. The damper on the fire level will automatically open to allow smoke to enter the shaft. The dampers on all other levels will lock out closed to prevent smoke spread to upper floors. The stairwell AOV will automatically open to allow inlet air into the stair core. Also on Smoke Detection, the duty fan will start to extract the smoke via the shaft. The fan flow rate is controlled via the pressure differential sensors located in the stairwell on the fire floor. 4 Stage Fire Scenario The fireman s over ride switch on each level operate independently. Once a fireman s override switch is activated the pressure differential switch is by passed and the fans run at full speed. The door to the stair core should be held open when the system is in this mode as the lobby will depressurise if the door is closed. Should the duty fan fail the standby fan will be automatically started with a changeover time of 10 secs. The pressure differential sensor ensures that the pressure difference between the stair core and the lobby does not exceed 15 Pa with all doors closed. The fans will continue to run until the fire alarm is fully reset.

System Components Damper - Advantage Purpose designed and tested for lobby to shaft application Damper with lobby grille 24vDC motor drive open/drive closed on fire alarm re-set 60 mins fire rated CE marked Tested and Certified to BSEN12101 - Part 8 Size dependent on Pa requirements Available in standard RAL colours Fans ELTA long cased axial fans D&S Smoke Vent 300 o C for 2 hours Volume m 3 /s project specific BS7346-2 (EN 12101-3) Stairwell AOV Brakel Eura Louvre type AOV Brakel MonoTherma Flap type AOV CE Marked EN12101-2 1.0m 2 free area Damper - Kamouflage Purpose designed and tested for lobby to shaft application Door type damper 24vDC motor drive open/pull closed on fire alarm re-set 60 mins fire rated CE marked Tested and Certified to BSEN12101 - Part 8 Size dependent on Pa requirements Standard finish can be painted, veneered or wallpapered etc MCC Control Panel CE Marked Conforms to IEC 61439-01 Conforms to the EMC directive

Mechanical Smoke Extract Shaft Systems Approving authority : London Fire & Emergency Planning Authority 74 no. Luxury Apartments 1 no. Mechanical smoke shaft Fireman s Override Switches Smoke Vent EN 12101 9 Colour: Orange 3 no. levels below ground floor 16 no. levels above ground floor BS 9991 and SCA compliant Sprinklered apartments 1MW heat release rate 4.5m 3 /s Mechanical exhaust Pressure Differential Sensor Dwyer Magnesense II CE marked 1 2 Code compliant natural ventilation system components - Overview (1) The AOV on top of the shaft and stair core is depicted in green, and the relevant doors in brown. The yellow spot marks the fire location. Mechanical ventilation system Overview (2) ABB Touchscreen Panel CE Marked The AOV on top of the stair core is depicted in green, the exhaust in red and the relevant doors in brown. The yellow spot marks the fire location. EN61000-6 CFD Study : Code Compliant Natural Shaft v Mechanically Ventilated Shaft Lansdowne Place, Ballsbridge, Dublin 4 Mixed use development Client: Chartered Land 215 no Luxury apartments 6 no. Mechanical smoke Blake Tower, Barbican, London Former YMCA Building with 20 no. levels above ground floor Client: Redrow PLC 4 no. Natural smoke BS 9991 and SCA compliant 6MW heat release rate 5.6m 3 /s mechanical exhaust

1 2 Code compliant natural ventilation system components - Overview (1) The AOV on top of the shaft and stair core are depicted in green, and the relevant doors in brown. The yellow spot marks the fire location. The vent to outside as per SCA document is depicted in light blue. safety systems should be serviced by a competent specialist contractor. A minimum of one full service and three inspections should be taken annually. Crossflow operate a Service and Maintenance Division providing statutory inspection and maintenance requirements as well as 24 hour/7day/365 call out cover. Projects Here are some prestigious projects Crossflow have been involved with. Mechanical ventilation system Overview (2) The AOV is depicted in green, the exhaust in red and the relevant doors in brown. The yellow spot marks the fire location. The vent to outside as per SCA document is depicted in light blue. Installation and Commissioning Installation by a competent, suitably trained and experienced engineer in accordance with the manufactures instructions and technical specification- BS7346-8 (7) 2013 Commissioning BS7346-8 (8) 2013 The responsibility of the commissioning engineer is to verify that the system operates correctly in the manner designed and that the installation workmanship is of an adequate standard. It is there necessary for the commissioning engineer to be provided with the agreed specification of the system. Maintenance BS7346-8 (9) 2013 As an integral part of the life safety systems and firefighting strategy, the mechanical must perform as designed in the event of an emergency. In order to ensure this, a schedule of preventative maintenance should be undertaken. EN 12101 & BS 9999 stipulates that the life Balham Hill, Clapham, London 1 no. Ext. Corridor mechanical 1 no. Mechanical smoke extract shaft Lambeth Palace View, London 2 no. Mechanical smoke extract Catherine House, Portsmouth 3 no. Mechanical smoke extract 2 no. Natural smoke extract Charlemont Street, Dublin 4 no. Mechanical smoke extract No. 1 Albert Quay, Cork 2 no. Mechanical smoke extract Westminster Quarter, London 4 no. Mechanical smoke extract

Unit 50, Hawthorn Road, Western Industrial Estate, Dublin D12 XK65. Tel: 01 4279300 Email: enquiries@crossflow.ie www.crossflow.ie