Features High efficiency Copeland compressors, with internal pressure relief valves and inherent thermal protection High quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity Whirlpool Split System 13 SEER Air Conditioner W2C3 Top discharge directs hot air and sound away from living area and shrubbery All units are factory run and leak tested Units are equipped with enhanced wire guard for condenser coil protection Easy access to electrical panels, pre-wired for easy hook-up Control panel allows simple access to electrical components 45 degree service valves for easy hook-up and service Liquid line filter drier installed in every unit All units ETL, ETLC approved and ARI listed Charged for 15 feet of interconnecting tubing Warranty: 5 year parts; 5 year compressor (see warranty certificate for details) 5 Year Limited Warranty on Compressor 5 Year Limited Warranty on All Parts Extended Warranty Available
Number Guide W 2 C 3 24 A - 1 A Whirlpool 2 - R22 Minor Revision Code C = Air Conditioning Major Revision Code 13-13 SEER Nominal Electric A - 208-2V/60Hz/1Ph B - 208-2V/60Hz/3 Ph Physical and Electrical Cooling Performance with Evaporator Coils Nominal Capacity 24-24,000 Btuh Refrigerant Compressor Fan Motor Maximum Connections Voltage Min. Circuit Weight Volts/Hz/Phase Fuse Rated Locked Full Number Range Ampacity Rated Nom. (lbs) (amps) Load Rotor Load Liquid Vapor HP RPM Amps Amps Amps W2C318A-2B 208-2/60/ 11. 4 15 6. 9 35 0. 7 1/10 1075 8 4 132 W2C324A-2B 208-2/60/ 15. 1 25 11. 3 51 0. 7 1/10 1075 8 4 140 W2C3A-2B 208-2/60/ 15. 7 25 12. 0 60 0. 7 1/10 1075 8 4 173 W2C336A-2B 208-2/60/ 21. 0 35 16. 2 82 0. 7 1/10 1075 8 4 176 W2C342A-1B 208-2/60/ 28. 0 45 21. 5 104 1. 1 1/ 5 1075 8 7/ 8 188 W2C348A-1B 208-2/60/ 28. 0 45 21. 5 97 1. 1 1/ 5 1075 8 7/ 8 204-1B 208-2/60/ 27. 9 45 21. 4 137 1. 1 1/ 5 1075 8 1 1/ 8 217 W2C318A-1A,B W2C324A-1A,B W2C3A-1A,B W2C336A-1A,B *Single or Three Phase Indoor Rated T SEER ARI CFM Expan. Piston or Field Installed Ratio Capacity WE(U,C,M)1P19A 17,100 560 # 53 WE(U,C,H,M)1P23(A,B) 17,400 560 # 53 WE(U,C,M)1P19A 17,200 560 WE(U,C,H,M)1P23(A,B) 17,400 560 WE(U,C,H,M)1P23(A,B) 23,200 # 62 WE(U,C,H,M)1P29(A,B) 23,600 # 62 WE(U,C,M)1P19A 22,800 WE(U,H,C,M)1P23(A,B) 23,200 WE(U,C,H,M)1P29(A) 23,600 WE(U,C,H,M)1P29(A) 28,600 WE(U,C,H,M)1P36(A,B,C) 29,000 WE(U,C,H,M)1P23(A,B) 27,800 WE(U,C,H,M)1P29(A) 28,600 WE(U,C,H,M)1P36(A,B,C) 29,000 WE(U,C,H,M)1P36(A,B,C) 34,600 # 76 WE(U,C,H,M)1P43B # 76 WE(U,,HC,M)1P29A 34,600 WE(U,,H,M)1P36(A,B,C) 34,600 WE(U,C,H,M)1P43B
Cooling Performance with Evaporator Coils W2C342A-1B W2C348A-1B -1B *Single or Three Phase Indoor Rated T SEER ARI CFM Expan. Piston or Field Installed Ratio Capacity WE(U,C,H,M)1P43(A,B,C) WE(U,H,M,C)1P49(C,D) WE(U,C,H,M)1P36(A,B,C) 40,000 WE(U,C,H,M)1P43(A,B,C) WE(U,C,H,M,)1P49(C,D) WE(U,C,H,M)1P43(B,C) WEC1P49C WE(U,C,H,M)1P50C WEC1P60D WE(U,C,H)1P62C WE(U,C,M)1P43(B,C) WEC1P49C WE(U,C,M)1P50C WEC1P60D WE(U,C,H)1P62C WE(U,C,H,M)1P49C 55,500 # 99 WE(U,C,H)1P62C # 99 WEC1P49C 55,500 WE(U,C,M)1P50C 54,000 WEC1P60D 55,000 WE(U,H,C)1P62(C,D) Accessories Kit Number / Part Number Description 20442712 / 12W19 Hard Start Kit 20442713 / 12W20 Hard Start Kit 20442505 / 14W08 Low Pressure Switch 20442506 / 14W09 High Pressure Switch 20442508 / 14W11 Low ambient kit 20442804 / 14W04 Crankcase Heater 20442805 / 14W05 Crankcase Heater 20442806 / 14W06 Crankcase Heater 20401504 Short Cycle Protection 204401 Liquid Line Solenoid 20442906 / 14W00 Compressor Sound Blanket 20442907 / 14W01 Compressor Sound Blanket 20442908 / 14W02 Compressor Sound Blanket Where Used W2C318A, 324A, 3A, W2C318A, 324A, 342A, W2C3, 336A W2C318A, 324A W2C342A, 348A, 360A W2C3A, 336A 336A 348A
Cooling Performance Extended Ratings Indoor W2C318A WE*P19 W2C324A WE*1P23 W2C3A WE*1P29 W2C336A WE*1P36 W2C342A WE*1P43 W2C348A WE*1P49 WE*1P62 * = Insert C for Upflow / Indoor Temp - DBºF Temp DB/W- 65 82 95 105 115 B ºF Btuh Btuh Btuh Btuh Btuh 19,500. 61 1.33 18,600. 65 1.50 18,200 1.57 17,200 1.63 16,000 1.69 18,400. 63 1.28 17,500 1.45 17,100 1.52 16,200 1.57 15,000 1.62 17,000 1.24 16,200 1.40 15,800 1.46 15,100. 77 1.52 13,. 77 1.56 26,500. 63 1.85 25,200 2.11 24,600 2.21 23,400 2. 21,700 2.38 24,. 65 1.79 23,800 2.03 23,200 2.13 22,000 2.21 20,400 2.29 23,100 1.72 22,000 1.95 21,500 2.05 20,444 2.13 18,. 80 2.20 33,100. 66 2.24 31,600 2.55,800 2.68 29,0 2.79 27,100 2.89 32,600. 52 2.39 31,000. 55 2.66 29,500. 58 2.77 27,0. 58 2.86 25,200 2.76,600. 57 2. 29,100. 60 2.56 27,700. 62 2.66 25,600. 63 2.75 23,0 2.65 40,200. 66 2.75 38,0 3.15 37,400 3.31 35,500 3.45 32, 3.57 37, 2.65 36,100 3.02 3.18 33,500 3.31 31,000 3.43 35,100 2.55 33,500 2.91 32,600. 80 3.06 31,000. 83 3.18 28,700. 84 3.29 46,200. 53 3.15 44,100. 66 3.60 43,000 3.78 40,800. 07 3.94 37,800 4.08 43,500. 64 3.03 3.46 3.64 38,500 3.78 35,600 3.91 40,0 2.92 38,500 3.33 37,500 3.50 35,700 3.64 33,000 3.76 52,500. 63 3.48 50,100 3.97 48,800 4.17 46,400 4.34 43,000 4.49 49,500. 65 3.36 47,200 3.82 46,000 4.01 43,700 4.17 4.31 45,800 3.24 43,700 3.68 42,600 3.86 4.01 37,500 4.14 65,000. 66 4.26 62,000 4.85 60,500 5.10 57,500 5.31 53,200 5.49 61,0 4.10 58,400 4.67 4.90 54,200 5.10 50,200 5.27 56,800 3.95 54,100 4.49 52,800. 80 4.72 50,200. 83 4.91. 84 5.07 Downflow; H for Horizontal, M for Multi-position; U for Uncased Sound Ratings MODEL SOUND RATING (DBA) W2C318A 76 W2C324A 76 W2C3A 80 W2C336A 80 W2C342A 78 W2C348A 80 80
Cooling Performance with Air Handlers W2C318A Indoor Piston or Field Installed SEER CFM Expansion Capacity Ratio WAHMS18-1A 17, 600 # 55 WAHMS24-1A 18,000 625 # 55 WMB24CB WE(C,U,H,M)1P23B 18,000 625 # 55 WAHMS18-1A+ 17, 600 WAHMS24-1A+ 18,000 625 W2C324A Indoor Piston or Field Installed SEER Rated ARI Capacity T Ratio CFM Expan. WAHMS18-1A 22,800 # 67 WAHMS24-1A 23,400 # 67 WAHMS-1A 23,800 # 67 WMB24CB WE(C,U,H,M)1P23,29B 23,800 # 67 WAHMS18-1A+ 23,400 WAMS24-1A+ 23,400 WAMS-1A+ 23,800 W2C3A Indoor Piston or Field Installed CFM Expan. SEER Cap. Ratio WAHMS2-1A 28,200 WAHMS-1A 29,000 WAHMS36-1A 29,200 WMB36CB WE(C,U,H,M)1P36B 29,200 WAHMS24-1A+ 28,200 WAHMS-1A+ 29,000 0.70 WAHMS36-1A+ 29,200 0.70 W2C336A Indoor Piston or Field Installed SEER CFM Expan. Cap. Ratio WAHMS-1A 0.72 # 78 WAHMS36-1A 0.72 # 78 WAHMS42-1A 35,800 # 78 WMB36CB WE(U,C,H,M)1P36,43B 35,800 # 78 WAHMS-1A+ 35,000 WAHMS36-1A+ 35,000 WAHMS42-1A+ 36,000
Cooling Performance with Air Handlers & Furnaces W2C342A Indoor Piston or Field Installed SEER CFM Expan. Cap. Ratio WAHMS36-1A WAHMS42-1A WAHMS48-1A WMB42CC WE(U,C,H,M)1P43,49C WAHMS36-1A+ WAHMS42-1A+ WAHMS48-1A+ W2C348A Indoor Piston or Field Installed SEER CFM Expan. Cap. Ratio WAHMS42-1A WAHMS48-1A WAHMS60-1A 48,000 WMB48CC WE(U,C,H,M)1P49C WAHMS42-1A+ WAHMS48-1A+ WAHMS60-1A+ 48,000 WAHMS48-1A 55,500 1 # 102 WAHMS60-1A # 102 WMB60CD WE(U,C,H)1P62D # 102 WAHMS48-1A+ 55,500 1 WAHMS60-1A+ Dimensions Dimensions A B C Number (in.) (in.) (in.) W2C318A-2B 22 1/ 2 22 1/ 2 25 W2C324A-2B 22 1/ 2 22 1/ 2 29 W2C3A-2B 29 W2C336A,B-2B 33 W2C342A-1B 37 W2C348A,B-1B 29,B-1B 33 A B C
Notes
All specifications are subject to change without notice. /TM Whirlpool and all other trademarks are owned by Whirlpool, U.S.A., used under license by Tradewinds Distributing Company, LLC. Form #W2C3.03 (08/07) 2007 Printed in U.S.A.