SAURUS HEATER / DRYER

Similar documents
CLIMATE CONTROL PRODUCT GUIDE

HEATING HEATING HEATING. Call for rates and reservations

REFERENCE INFORMATION

JOB-SITE HEATERS PROPANE KEROSENE ELECTRIC

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

Power & HVAC. Keep the power on and the climate under control. We re here to help.

Click Here To View Item at

Mi-T-M carries a full line of portable heaters, built in the same quality tradition you ve come to expect from us.

Arcotherm Heaters by Cantherm HEATER CATALOGUE

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

Construction Equipment Sales, Service and Rentals

U n i t H e at e r s

BLAZE 400G TURBO & BLAZE 600D TURBO I & Input BTU/h: 399,000 (400G), 575,000 (600GT & 600GTII) Indirect NG/LP Beckett Burner

PORTABLE HEATERS FOR PROFESSIONAL USE

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

MD-170 Installation/Operator's Manual

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Econoburn Technical Datasheet

PORTABLE HEATERS FOR PROFESSIONAL use

TASKS REGARDING COMBUSTION AIR

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

LADERA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

EQUIPMENT RENTALGUIDE

A non-toxic zero-emf radiant floor heating system

1. AirTop Air Heater. 2. AirTop Heater Kit. 3. AirTop Evo Air Heater. 4. ThermoTop Water Heater. 5. Isotemp Water Heaters

THE HK500, HK300 & HK150 MOBILE GLYCOL HEATING SYSTEM

BOILERS. Air Vent. Supply. Drain Valve

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Workin Warm.Workin Warm. Workin Tough. CONSTRUCTION HEATERS CONSTRUCTION HEATERS

Universal Fire Tube Boiler Wall Mount Models

GARAGE / WORKSHOP INFRARED HEATERS

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

INDUSTRIAL HEATING CATALOG

comfort and peace of mind

Modular Panel System for Radiant Floor Heating.

Comfort Survey Aquila Investment Gr A oup. quila Investment Group.

Multi-Housing. Commercial Top Load Washer. Electronic BUILT FOR RELIABLE PERFORMANCE ELECTRONIC CONTROL. Rear Control

Heaters & air dehumidifiers.

HVAC Equipment Access Equipment Location

C O D E S & A M M E N D M E N T S

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Massachusetts Energy Efficiency Partnership. 5. High Efficiency Systems for Large Boilers

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.

SUBMITTAL SCHEDULE & DATA

Work In Shirt-Sleeve Comfort When It s Doggone Cold

CATALOG: HVAC - Gas Space Unit Heating

Solar Air Heating Roofing and Siding for Government and Commercial Buildings

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

TRADESMAN FORCED AIR LP/NG HEATERS

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Portable Radiant Heaters. Convection Heaters FEATURES: MTankCo.com LEADERSHIP INTEGRITY

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

Models. Options. Standard Features. LoH 2 O

MONTECITO. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

Boiler Technical Specifications (2013)

Flame115 Radiant. Flame115 Specifications. Flame115 Accessories

GLOBAL FINISHING SOLUTIONS

(TAPE #504) Dial-U-TELETIP Script AIR-TO-AIR HEAT EXCHANGERS" Roger A. Peterson

Air Handler Installation Instructions Water Lines

D. TURBO BLOWER 1.) Turbo fan type 2.) 40 HP motor

True performance and rugged durability. TU, LF and LD Models

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

Capture Waste Heat with Ultra-High Efficiency

New Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

PARAFFIN/DIESEL FORCED AIR HEATERS

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

Grain Dryer Exhaust Air Recycling System

Geothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

EnergyMeasure HOME DATA COLLECTION FORM

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

Split Portable Air Conditioner

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

TMB Baking TSV Gas Oven TAG Series. Contractor s Utility Requirements

CLEANING & FLOOR CARE

Please read before proceeding

Glass Canopy Wall-Mount Hood

2015 MECHANICAL CODE REQUIREMENTS

PARAFFIN/DIESEL HEATER

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

RED DOT UNITS HEATER ONLY. Heaters PAGE 51

User s Information Manual Models:

Basic Building Science insights for Spray Foam, HVAC and Moisture

13 GEP A L P - 1 A

CONDENSING WATER HEATERS GAS FIRED 55 I 80 I 119 I U.S. GALLONS

Technical Data Manual Model Nos. and pricing: see Price List

CCS Rents! C C. S Contractor. Equipment & Supply, Inc. We offer a complete line of construction equipment for rent:

THE PROFESSIONAL S CHOICE SINCE 1953 INDUSTRIAL HEATING & COOLING CATALOG. masterindustrialproducts.com

Installation Instructions DAR 1150, DAR 1220 DAR 1230, DAR 1250

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FUEL GAS CODE 2009 EDITION.

Transcription:

SAURUS HEATER / DRYER INDIRECT - FIRED MODEL 800 Specifications Output* 800,000 BTU/ Hr Blower* 11,000 CFM @ 1/2 SP Fuel NG & LPG or Oil Efficiency 82% NG 85% LPG Fuel Consumption** 800 CU. Ft NG/hr Max @ 5-100 PSI (typical 600 CU. Ft NG/hr) 8.8 Gal LPG/hr Max (typical 24 Litres LPG/hr) 5.8 Gal Oil/hr Max (typical 18 Litres Oil/hr) Inlet Duct Size 2 X 24 Outlet Duct Size 2 X 24 Electrical*** 40 Amp Breaker, 230 V single phase Optional 30 Amp Breaker, 208 V 3 phase Dimensions 53 W X 72 L X 90 H. Approx. Weight 1,800 lbs (820 KGs) Preset Duct Temp Limit Adjustable to 175 F (80 C) Preset Upper Limit 240 F (115 C) Preset Lower Limit 200 F (93 C) * Measured at the end of Hot Air Duct ** Consumption will decrease as return air temperature rises and burner is cycled off. Max consumption figures bases on continuous firing, followed by (typical operating values). ***Single phase starting current typically 120 Amps, continuous running 23 Amps. 24 DUCT Lifting Eyes DIFFUSER 24 t0 3 X 12 DUCT 25 X 24 DUCT 25 X 24 REMOTE THERMOSTAT 26 FORKLIFT POCKETS WWW.saurus.ca stanley.g@saurus.ca DISTRIBUTION, SALES & SERVICE SAURUS HEATERS INC. 1-888-215-1335

APPLICATION SUMMARY LARGE BUILDINGS: Typical size 20,000 to 60,000 SQ.FT. per Model 800 Warehouse: 22,000 SQ. FT. 25 FT Ceiling 550,000 Cubic FT. (1 heater) Warehouse: 550,000 SQ. FT. 28 FT Ceiling 9.8 Million Cubic FT. (6 heaters) GROUND THAW: Typical size 10,000 SQ. FT. per Model 800 Heater in middle 1 Supply 1 Return each way 24,000 SQ. FT. 3 to 4 of Frost in 12 to 14 days (2 heaters) TRENCH 200 X 10 W X 6 D 3 of Frost in 4 days SPECIAL PROJECTS: Underground 45,000 SQ. FT. (1 heater) Published Total Fuel Replacement Make / Model BTU*1000 ºF CFM*1000 LPG/Hr LPG/Hr Factor Saurus 800 800 * 175 11 24 24 1 ICE OHV 350 350 220 2.5 11 55 5 ICE OHV 500 450 220 3.0 14 56 4 ICE OHV 700 630 220 4.3 23 69 3 Wacker Cub 700 576 200 7.7 23 69 3 Thermobile IMAC 2000 630 167 6.5 23 69 3 DryAir Boiler 1.2 M 900 5.0** 46 92 2 SureFlame 1 M 5.0 45 180 4 * Delivered heat measured at the end of 50' of duct. ** Air flow depends on number of air units. 45,000 SQ FT X 6 Floors + Underground No-vented with CO monitoring (7 heaters) SAURUS 800 PROVEN FUEL REDUCTION WWW.saurus.ca stanley.g@saurus.ca 1-888-215-1335

Stairs Diffuser 24 to 3 x 12 small air mover 12 24 On Site Glycol Return Air Saurus 800 NG City of Calgary Water Centre: 160 M long by 20M wide One 800 NG replaced 6 MBTU per hour direct fired heaters; - improved efficiency reduced operating costs, add to LEEDS design. - improved air quality, quiet operation and constant temperature. - No contamination of drywall, paint or concrete. Large air mover used to circulate heat back to return air inlet

Grey Eagle Casino in Calgary: 187.000 Sq. Ft. Replaced 16 MBTU per hour direct fire heaters with two 800 Saurus LPG. - Improved air quality, dryer with no combustion odor. No contamination of concrete. - Operating cost reduction by recycling air with thermostatically controlled temperature. - Propane consumption reduced from 3,500 to 850 litres LPG per day. plus fewer generators and related diesel fuel. North West Saurus 800 LPG @ Rear Front View South East Saurus 800 LPG

Warehouse Application 350,000 SQ FT_ 28 FT Ceiling 9.8 Million Cubic FT. Quantity 6 Model 800 Propane SAURUS HEATERS INC. 1-888-215-1335 www.saurus.ca

Trench Ground Thaw and Cement Curing Heaters at each end push and pull air to recycle and heat. 1. Make tunnel on bottom of trench and ground thaw. 2. Install footings and forms and cover with hoarding and heat. 3. Pour concrete and cover with heat for curing. Unit 1: 800 Propane Unit 2: 800 Propane 340 ft West view East view

Ground Thaw Home Depot Warehouse Loading Dock One 800 Natural Gas Heater, 4 fans in 200 X 10 X 6 trench for loading dock. One hot duct and one return out each way. Fan shown to move heat along the bottom. In 4 days 3 feet of frost was removed. One extra day for good measure.

School Native Soil Ground Thaw In February 2009, 5 school projects used our heaters to thaw native soil. The sizes were 19,000 to 24,000 squ. ft. at a time. This is the typical hoarding done with a heater at the front and one at the back. One 25KW generator was used which also powered 4-42 inch fans. Thawing occurred with 12º to 15º C air cirulated above the ground. Day time high temperatures ranged from - 20ºC to -10ºC. Frost from 3 to 4 feet was removed in 12 to 14 days. Advantages over boilers; - 4 hour set up time instead of days with hoses and tarps. - The trades continued to work in side a warm space. No accumulation of mud. - Less than 1/2 the fuel of a boiler. - No hidden maintenance or support costs.

Underground Parking Garage 800 Natural Gas 27,000 SQ. Ft. Replaced 2-1M direct fire 800 Natural Gas 45,000 SQ. Ft. Replaced 2- Almund Brothers and Glycol system

U of C Library Storage This long and narrow, 22,000 sq. ft. building required 2 Model 800 gas units at the beginning of the project and reduced to one unit as the building closed in.

Calgary Westjet Office Non Vented Application with CO monitoring Office complex with 6 stories and underground facilities and parking. The underground used 1 Model 800, the main floor 2 and 1 unit for each floor, 2 through 6. The foot print is 45,000 sq.ft. per floor.

Suncor Community Leisure Centre Fort McMurray, Alberta Water park section of the facility: The area heated was the entire water park using 5 Model 800 Saurus Heaters, operating on 15 PSI NG. The special masonry, tile and adhesives required temperatures up to 15ºC at pool level while outdoor tempertures ranged from -25º to -50ºC. The temperature was -52ºC on the day of the pictures, December 15, 2009. Heat was moved along the ceiling and ceiling fans used to direct heat down to floor level. Specific ducts were used to direct heat below floor level. Return ducts also pulled cool air up from the lowest levels. H1 H2 H5 H3 H4