Water Underfloor Heating Kit

Similar documents
Water Underfloor Heating Kit

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ONE LARGE ZONE

INSTALLATION INSTRUCTIONS SINGLE CIRCUIT

Method Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others:

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

Underfloor Heating Installation Guide

Installation Guide. Maximum Area 20m 2

Case Study - Yardley Park Road Gerpex MLCP and Press Fit System, Underfloor Heating and Manifold Based Sanitary Systems

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

UNDERFLOOR HEATING EXPRESS. UK s Water & Electric Underfloor Heating Supplier

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

Product and installation manual. Underfloor Heating

Thermomix Underfloor Heating Control Pack

warm water underfloor heating installation manual v4b-aug 08 Nu-Heat design innovation expertise service

HEATING UNDERFLOOR PRODUCT.GUIDE. Underfloor Heating for the professional heating and plumbing engineer. EXCELLENCE IN UNDERFLOOR HEATING

tep by step Installation Guide Install a complete underfloor heating system, up to 112m 2, using one simple pack.

Nu-Heat. SPECIFYING NU-HEAT LoPro Max. A Best Practice Guide for professional installers

Single Room Packs. Total m m m m m 2. Multiple Room Packs

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

Whether you are coming in from a cold night, a heavy rain shower or a long day at work nothing is more inviting then a Joule Underfloor Heating

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Technical Helpline. Installation Manual. WHS-M-S3-Series Manifolds. Hydronic Heating System

LoProLite OneZone installation manual for floating floors

Underfloor Heating Control Pack

Simple. Smart. Solutions.

Manifolds Controls Pipes Accessories

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

Carbon Film Installation Instructions

Hydronic Underfloor Heating

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

Electric Warm-Stretch under floor heating

Thermotech underfloor heating

UNDERFLOOR HEATING SYSTEM C SYH ME UNDERFLOOR HEATING SYSTEM. Heating Homes All Around The World.

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Polypipe Plumbing & Heating

Installation And User Instructions

Polypipe Plumbing & Heating

BEGETUBE UK UNDERFLOOR HEATING SYSTEMS TECHNICAL MANUAL

Polypipe Underfloor Heating

Polypipe Underfloor Heating

About us.

Luxusheat. Price List - February Underfloor Heating. Luxusheat Underfloor Heating Price List

lightwaverf Boiler Switch Model No. JSJSLW920 Instruction Manual Professional Series

Underfloor Heating Mat Installation Manual

Polypipe Underfloor Heating

Reliable Family Run (Husband & Wife Formed) "Twice recommended by"time Out" London in 2006"

Nu-Heat UNDERFLOOR & RENEWABLES

Installation And User Instructions. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

ADVANCE ELECTRIC THERMAL STORE

DOMESTIC HOT AND COLD WATER SUPPLY AND CENTRAL HEATING SYSTEMS. Guidance Notes

Underfloor Heating & Controls. Part of the Whole House System from OMNIE.

UNDERFLOOR HEATING GUIDE

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

ADVANCE ECB ELECTRIC COMBINATION BOILER

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

THE PUSH-FIT SOLUTION FOR UNDERFLOOR HEATING

Underfloor Heating Systems

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand

Assessment Schedule - TS.6

System 70 Datasheet/0105

THE OXYVENT TANK. Patent No. EP INSTALLATION MANUAL. This Manual is to be left with owner. TUV Certificate of Design Approval

Design, supply and installation specialists of wet and electric underfloor heating systems, latex and insulation

Simple. Smart. Solutions.

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Underfloor Heating Cable Installation Manual

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

MEGAFLO HE Iss 1

Uponor Comfort E AL-Foil Mat

Technical and Specification Information. Greenfloor heating series GREENFLOOR HEATING VIDEO AVAILABLE ON OUR WEBSITE

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Zircon Installation Manual

SEALED THERMAL STORE

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

Data Sheet. Self regulating heating tapes. RS stock numbers

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

Price List 2017 NEW: Radiant heating & cooling, plumbing and local heat distribution. Uponor PRO App

THE PUSH-FIT SOLUTION FOR UNDERFLOOR HEATING

Uponor. THE NATIONAL ENERGY FOUNDATION Ground Source Heat Pump Seminar 12 th May Who Are We???????? Radiator

Installation and servicing instructions

Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

METRO BASIN MONO MIXER CHR

Introduction. Overview DOMESTIC HOT AND COLD WATER SUPPLY AND CENTRAL HEATING SYSTEMS

Installation Instruction

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

Data Sheet. Self regulating process heating tapes RS stock numbers ,

5UNDERFLOOR UNDERFLOOR HEATING UNDERFLOOR HEATING

GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE

UNDERFLOOR HEATING SYSTEMS BY SCHÜTZ.

Underlaminate Foil Heater

Installation and Operating Instructions

Underwood Heater Installation Manual

Transcription:

Water Underfloor Heating Kit INSTALLATION MANUAL For multiple rooms 50 year pipe warranty CE approved Easy to install MULTIPLE ROOM SYSTEM INSTALLATION MANUAL

Manufactured in Europe! MULTI ROOM SYSTEM INSTALLATION T ION Thank you for investing in our industry leading ProWarm underfloor heating system ProWarm Water Underfloor Heating Systems are the ideal choice for homeowners and tradesmen wishing to install a premium branded water underfloor heating kit. This instruction manual contains important information regarding the safe installation and operation of your underfloor heating system. Please read carefully. See our online videos for helpful guidance In addition to this manual we have online installation videos that guide you through each stage of process with easy to follow CGi graphics and helpful dialogue. Scan QR code to watch video 2 Technical support 01268 567019

Before you begin Installing: Please read through these instructions carefully and check that you have all the components required. ProWarm water underfloor heating kits contain everything you need in one box for your water underfloor heating project. NB: This multi zone system is controlled by multiple thermostats. A rated UPS 2 Grundfos pump PE-Xb-multilayer pipe to suit area Edging insulation (NA: for low profile) Manual Thermostat Pipe rerounding tool Wiring centre All pipe connections to fix pipe to pump and manifold Actuators Pipe Staples Pipe Cutters We use high quality multi layered pipe (PE-Xb-Al-HDPE) in all our ProWarm water underfloor heating systems AN INNER LAYER in cross-linked polyethylene PE-Xb (crosslinked with silanes) PIPE WARRANTY PE-Xb-Al-HDPE. Working pressure & temperature10bar, 95 C. 100% oxygen impermeable. Lifetime warranty. TWO BINDING LAYERS of adhesive bind the metal pipe with the two outer layers in cross-linked polyethylene AN INTERMEDIATE LAYER in aluminium alloy, butt-welded along length of pipe. AN OUTER LAYER in cross-linked polyethylene PE-Xb-Al-HDPE (crosslinked with silanes). MULTI ROOM SYSTEM INSTALLATION www.prowarm.com 3

Installation for a multiple room (multi circuit system) Typical 1 circuit layout Typical 2 circuit layout MULTIPLE ROOM pipe layout 1) Select a suitable location for the pump & manifold unit and mount on the wall. See opposite page for assembly. 2) Refer to the typical pipe installation drawings and determine the pipe layout - the layout is not critical and can be varied to suit site conditions, the important criteria being the pipe spacing, see below. 4) The pipe is marked every metre by the metre. (maximum length for any circuit is 110m, 70m for low profile 12mm pipe circuit). 5) Pipes should be laid 100mm away from walls. 6) Do not lay pipe under fixed units. 7) Lay the rooms furthest from the manifold and work back, do the room with the manifold last. PIPE SPACINGS STANDARD OUTPUT SYSTEM suitable for internal well insulated areas such as a living room, kitchen or bathroom. Pipe spacings are set at 250mm centres. 8) When pipes to/from one area pass through another area, the two pipes should be run together, the bunches of pipes should then be spaced as if they were one pipe. 9) Lay the pipe as planned, fixing every 1.0m if on a screeded celotex base and return to the manifold. 10) If the pipe is kinked when bending, the pipe should be straightened and rearranged so that the location of the kink remains in a straight length, no other remedial action is required. LOW PROFILE SYSTEM panels are spaced at 150mm centres HIGH OUTPUT SYSTEM suitable for areas of high heat loss, ideal for conservatories, extensions and external buildings. Pipe spacings are set at 200mm centres. 4 Technical support 01268 567019

11) To lay the circuit, cut the pipe end squarely using the plastic pipe cutter, re-round the pipe end with the tool provided, place the nut over the pipe, ensure the olive and insert is fully fitted over the end of the pipe and the assembly is attached to the manifold. Tighten the nut using an open end spanner. Do not over tighten. 12) Note also the room to which each circuit applies. 13) Prevent people from walking on the pipes, keep tools etc away from the pipes and use running boards. The pipe is very tough, but it is better to be safe than sorry. PUMP & MANIFOLD ASSEMBLY Flow meters Wiring centre Return to boiler Ball valves Pump Mixing valve Flow from boiler Fill & drain valves Actuators to UFH circuit 1) Attach manifold to wall. 2) Fit ball valves to manifold, the end with the loose nut to manifold( remember the washers!). 3) Assemble pump & mixing valve as shown. 4) Connect supply pipework to mixing valve using ¾" male iron compression fittings. DO NOT APPLY HEAT TO MIXING VALVE FILLING THE MANIFOLD SYSTEM 1) It is IMPORTANT that the underfloor heating system is properly filled with water and purged completely of air to ensure correct operation, it is therefore necessary to follow the procedure below. 2) IT IS NOT ADEQUATE TO FILL THE SYSTEM USING THE BOILER FILLING LOOP! 3) Connect a hose from a mains pressure cold water supply to the hose connection on the top (flow) manifold, and another hose from the hose connection on the bottom (return) manifold to a drain. 4) Ensure that all the black caps on the bottom (return) manifold are screwed down, closing the valves. MULTIPLE ROOM pump & manifold assembly & filling www.prowarm.com 5

MULTIPLE ROOM filling the manifold / commisioning / mantenance FILLING THE MANIFOLD SYSTEM (cont.) 5) Ensure that the main flow & return ball valves are closed on the manifold. 6) Turn on the water and open the hose connection valve on the top (flow) manifold. 7) Open the first circuit valve by unscrewing the black cap allowing water to flow into the pipe. 8) Open the hose connection valve on the bottom (return manifold) allowing water to flow freely into the drain until the water is clear with no air bubbles. 9) Open the second circuit valve (black cap) and close the first. COMMISIONING 1) Screed or chipboard flooring should be laid immediately after pipelaying to protect the pipe. 2) Concrete screed floors must be cured before any heat is applied, a general rule of thumb is to allow 1 day per 2 millimetres of screed. 3) Timber floor with drymix infill can have heat applied immediately, the drymix must be dried completely before laying the flooring. 4) Hardwood timber flooring must be conditioned before fixing. 5) It is important to purge the pipework from the boiler to the manifold, to avoid air being introduced into the underfloor heating system. 6) It is not normally necessary to balance the system but if required follow this procedure. The system is balanced by running the pump, and adjusting the flow to each zone by turning the square spigots under the blue caps on the bottom manifold, the flow in the respective sight glasses 10) Open the third circuit valve and close the second etc. 11) Continue until the last circuit has been purged and close the hose connection valve on the bottom (return) manifold before closing the last circuit valve (black cap). 12) While under pressure, check manifold & pipework for leakage. 13) Close hose connection valve on the top (flow manifold) and remove the hoses. 14) If possible pressure test the system to 6 bar for 2 hours. should be set at a figure calculated by dividing the length of pipe for that zone by 40. Example: Circuit 1, 85m 40 = approx 2 on the scale. Low profile systems circuit at 70m 40=1.75. 8) Fit actuators to valves after connecting the control wiring. 9) It is important that the actuators are screwed tightly on to the valve. 7) Initially start the system with the thermostatic valve set at min (35 c). 8 Increase the setting by 5 per day, up to a maximum of 50 for concrete floors, max 65 for timber floors. 9) The flow & return from the boiler should be connected to the manifold connections shown using compression couplings. 10) NOTE. When first starting up the system it may take 12-24 hours for the heating effect to become apparent! MAINTENANCE It is recommended that the following maintenance be carried out annually. 1) Check that all actuator nuts are tightened firmly and that actuators are not loose. 2) Remove end plug from pump and check that pump rotates when energised. 3) Turn up thermostats and check that actuators move into open position also check flow gauges are indicating. If not, re-pressurise manifold, remove indicator, clean and replace, repressurise manifold. 6 Technical support 01268 567019

Electrical setup 1) Wiring from thermostats to manifold wiring centre should be 1mm 3core + earth (6243Y). NB: A network system must be wired in 'CAT6' cable. 2) The wiring centre has a back entry to avoid surface wiring. 3) Where one room has more than one pipe circuit it will be necessary to connect all the circuit actuators to that particular zone on the controller, controlled by one thermostat. 4) Thermostat position in the room is not critical but positions affected by the sun should be avoided, mounting height approx 1.5M Heatmiser DS1/DT/ PRT/PRT-TS For wireless systems see instructions supplied with wiring centre N L A1 A2 N L 1 2 3 N L 3 N L 1 2 3 2 room thermostat connections 3 Only required for manual dial stats TIME CLOCK ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 EXTERNAL PROGRAMMER L N L E N IN OUT L E N GrOr L E N MAINS BOILER UFH P/P UFH VALVE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 230v AC supply connect across room thermostat connections in combination boiler WARNING: DO NOT CONNECT 230V FROM THIS CONTROL SYSTEM TO THE BOILER TERMINALS OR BOILER MAY BE DAMAGED! manifold pump manifold actuators (up to 4 per zone) ELECTRICAL setuup www.prowarm.com 7

hot water programmer cylinder thermostat Boiler + hot water + underfloor heating N L Earth wires omitted for clarity! Supply 230V AC refer to wiring centre schematic for these connections X ufh manifold 1 motorised valve DHW motorised valve UFH1 M M power to boiler & boiler pump hot water + radiators programmer room thermostat (radiators) cylinder thermostat Boiler + hot water + radiators + underfloor heating N L ELECTRICAL setuup motorised valve DHW M N underfloor heating programmer M L motorised valve radiators motorised valve UFH1 M Supply 230V AC Earth wires omitted for clarity! power to boiler & boiler pump refer to wiring centre schematic for these connections X ufh manifold 1 8 Technical support 01268 567019

Schematic for system boiler & UFH + radiators + hot water HWC Motorised valves Boiler Boiler pump (not needed on a UHF only / Hot water sytsem) UFH Schematic for gas combination boiler & underfloor heating + radiators Combination Boiler Motorised valves UFH ELECTRICAL setuup www.prowarm.com 9

Typical fixing methods UNDER NEW CONCRETE OR SCREED FLOORS A cost effective solution for installing water underfloor heating into new build properties or new extensions. This type of system installation is the most popular and cost effective type on the market today, the pipes are incased in screed or concrete meaning that the whole floor warms up like one huge storage radiator. This system is normally for new build houses or extensions/conservatories. CLIP RAIL SYSTEM BETWEEN JOISTS OR SUSPENDED FLOORS Installing water underfloor heating between joists is easy using our different installation solutions. Please note all in joist systems require the pipe spacing to be 200mm apart or less This means you need to select a conservatory style kit or a multiple room kit standard room kits are designed with the pipe spacing at 250mm centers which would mean you would not have enough pipe in the kit SPREADER PLATE SYSTEM TYPICAL FIXING METHODS OVER EXISTING FLOORS Installing water underfloor heating over existing floors is simple using our different installation solutions. Our overfloor systems can be installed directly over any solid subfloor such as existing floorboards, plywood or concrete/ screed floors, or any solid surface such as existing tiles/ wooden floors. FLOATING FLOOR PANELS for finished timber floor 10 Technical support 01268 567019

PLASTIC EGG CRATE SYSTEM CLIPPED DIRECT WITH STAPLES DRY BISCUIT MIX/ SCREED SYSTEM IN JOIST FOIL BOARDS SOLID FLOOR PANELS for finished tiled floor For more information on various floor fixings watch our helpful videos for step by step guidance. Scan QR code to watch videos TYPICAL FIXING METHODS www.prowarm.com 11

Visit us online for a list of suppliers: www.prowarm.com Call us direct for technical advice: 01268 567019 Unit 12, Carnival Park, Carnival Way, Basildon, Essex, SS14 3WN T: 01268 567019 www..com