CAREL heatersteam Electric Element Steam Humidifiers

Similar documents
heatersteam unprecedented precision and reliability

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

heatersteam unprecedented precision and reliability

heatersteam titanium Climate Platform Climate Business Unit

"ER" Series Electric Humidifier

"ESDDR" Series Electric Humidifier

SEQUENCE OF OPERATIONS

LE Series. Electrode Steam Humidifiers

NHRS Series RESISTIVE ELEMENT STEAM HUMIDIFIER. Engineering Manual. Manual No. H

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

OPERATION AND MAINTENANCE MANUAL. Electrode Steam Humidifier Nortec EL Series

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Feature Summary. I. System

Revitalize Building Mechanical Systems (4619)

RESISTIVE STEAM HUMIDIFIER

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

The SKE humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

SECTION HUMIDITY CONTROL EQUIPMENT

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

Pressure Steam Humidifiers LS SERIES. humidity.com

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

ACTIVE INFRARED BARRIER

The integral solution for. Air Handling Units. Technology & Evolution

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Installation, Configuration and User Manual

Residential Steam Humidifier

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

READ AND SAVE THESE INSTRUCTIONS

OPTIMUM APPLIED SYSTEMS,

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Across-the-Line SERIES MP300 Combined Manual and Automatic

Soft Start Series MP700 Solid State, Reduced Voltage

Med Touch Master Alarm

Electric Coils. Blower Coils. Product Information

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Chilled Water Precision Air Conditioner for Critical Application

Integrated Automation Instrumentation & Terminal Devices

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Humidifi er FAQ. Why is the humidifier not running? The following conditions need to be satisfied before the humidifier sequence can start:

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Sequence of operation

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

SIMPLICITY BY DESIGN M52 CONTROLLER

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Specification for On-Line UPS Battery Monitoring and Data Management System

Flexible & Innovative. Cooling Solutions

Ventilation in balance

STEAM TO STEAM HUMIDIFIER

STEAM TO STEAM HUMIDIFIER

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Variable Frequency Drive SERIES MP800 VFD

SECTION SAMPLE SPECIFICATION FOR BOILER CONTROLLER CONVERSION KIT

Corrigo E. Second generation which contains all applications and languages

PART 1 - GENERAL 1.1 WORK INCLUDED

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

EC Series Wall Unit Humidifier

Power Flame Incorporated

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

Help. Help Software Tutorial. Building a Load Sizing Project with an SETC Humidifier and a mini SAM-e Distributor

RAYCHEM NGC-30 COMPONENTS

YOUR PARTNER IN FIRE & GAS DETECTION

Installation, Operation, Maintenance, Spare Parts, and Exploded Views Guide

************************************************************************************************************************

READ AND SAVE THESE INSTRUCTIONS VAPOR-LOGIC VERSION. Humidifier Control System. Installation. n Operation Manual

Vapor-logic VERSION 5 Humidifier Control System

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

READ AND SAVE THESE INSTRUCTIONS

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Altitude Chambers.

opti-visor ultra-efficient chiller plant automation Typical specification

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Project Name: Location: Engineer: Contractor: I. GENERAL

Steam Humidification Light Commercial Applications. Better technology means better business.

NU2 Smart Power Supply (SPS) Manual

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

NH-EL. The evolution of the industry s most trusted electrode steam humidifier NH SERIES. humidity.com

I/O ZONE 560/583 USERS GUIDE

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

NA G µair CONNECT 2

Model Smart Digital Humidistat

Transcription:

Suggested Engineering Specifications Section 23 84 13 CAREL heatersteam Electric Element Steam Humidifiers 1. GENERAL SCOPE 1. Furnish and install as indicated on the drawings and plans, in-duct [space] electric element steam humidifiers. 2. Furnish owner's manuals and blueprints covering installation, start up, maintenance and operating instructions, complete in every way to permit efficient operation and maintenance of the system. 3. Manufacturer shall warrant the system to be free from defects in materials and workmanship for a period of 2 years after the sale. 4. Capacities are as shown on the drawings and plans. 2. PRODUCT HUMIDIFIERS 1. The humidifiers shall be of the self-generating electric element type, electrically producing atmospheric steam in a 316 stainless steel heli-arc welded steam generator, and capable of operating on normal or demineralized water without modification. 2. The humidifier cabinet shall be constructed of 16 gauge steel, painted or coated inside and out to protect against corrosion and to be aesthetically pleasing. Electrical and steam generating compartments shall be separated, but contained in the same cabinet to minimize field wiring. 3. The electric elements shall be corrosion resistant Titanium and shall be able to be operated dry without burning out. Heater elements that cannot operate dry without burning out are unacceptable. Electrical connection to the elements shall be by screw down connectors. Spark plug type connectors can loosen and are therefore unacceptable. 4. The electric elements shall have embedded temperature sensors for high temperature shut down and stand-by preheating capability. 5. The steam generator shall be constructed of 316 stainless steel with a drain strainer for ease of maintenance. The steam generator shall be able to be removed from the cabinet for cleaning. The top shall be removable by a clamp and sealed with a gasket. Copyright CAREL USA +03U221775 Rev. 2.2 20160810

6. The steam generator shall have an external insulation jacket, and on smaller units, a Kevlar internal liner to increase efficiency and make cleaning easier. 7. The humidifier shall have thermal shock feature, removing lime scale from the heating elements, extends the cleaning intervals and make maintenance easier. 8. The steam generator water level control shall be by two float switches housed in an external, pressure-equalized electronic capsule with level indicator LEDs. Electrodes float switches or valves located inside the steam generator are subject to mineral build-up and therefore are not acceptable for water level control. 9. The steam generator shall also have twin sensing electrodes for detection of water foaming. The humidifier shall have the AFS anti-foaming system. 10. Units shall incorporate a power drain pump instead of drain solenoid to provide for more efficient flushing of the steam generator. 11. All internal electrical controls and components shall be prewired to appropriately marked terminals for field connection. All internal components and the cabinet shall be properly grounded and shielded to prevent any line or radiative interference. 12. The humidifier shall incorporate a true microprocessor control providing the following functions: a. Start-up wizard with simple step by step machine configuration during first commissioning. b. Automatic flushing of the steam generator based on feed water conductivity, not just time, to extend the life of the elements and reduce maintenance cycles. The humidifier shall read the incoming water conductivity to establish drain patterns and eliminate the need for a surface skimmer. c. Master slave capability to extend the capacity with automatic rotation. d. Integrated backup of the unit for applications that require continuous service and non-stop operation. e. Digital LCD Display of: Incoming water conductivity Electric current draw in Amps Output of the humidifier Selected output limit Model No. and unit configuration Display of sensed %RH on unit Display of %RH setpoint Display of differential 13. The humidifier microprocessor control shall incorporate complete diagnostics, including the following alarms and pre-alarms which shall be shown on the LCD display: Safety thermostat shut down Element overheat Low water level High supply water conductivity Power failure Lack of water Humidity sensor defective Water foaming in steam generator Copyright CAREL USA 2 +03U221775 Rev. 2.2 20160810

Improper steam generator fill rate Improper steam generator drain rate Diagnostic memory test fail Steam generator maintenance required All pre-alarms shall be self-correcting. 14. Humidifier shall operate on/off from an external dry contact (humidistat). Manufacturer shall supply a [wall mounted] [duct mounted] control humidistat, duct hi-limit humidistat and duct mounted airflow switch. 15. Humidifier shall operate modulating from an external demand signal provided by either an external controller or DDC system. Manufacturer shall supply a duct mounted hi-limit humidistat and duct mounted airflow switch. 16. Humidifier shall operate stand-alone and modulating from the internal controller and an external [wall] [duct] humidity sensor provided by the manufacturer. Manufacturer shall supply a [wall mounted] [duct mounted] humidity sensor, duct mounted hi-limit humidistat and duct mounted airflow switch. 17. Humidifier shall have RS485 serial port ready to communicate on Modbus, BacNet or Carel protocol with no additional devices. 18. Humidifier shall have Ethernet port ready to communicate on Modbus, BacNet protocol with no additional devices. 19. Humidifier shall have a integrated web server is used to configure and monitor the main unit parameters directly from a PC. In fact, using the Ethernet port on the humidifier controller, the unit can be accessed via a local network by simply entering its IP address in the browser. 20. Humidifier shall have Tera cloud or encrypted VPN connection remote access only via a secure connection. 21. If modulating, modulation of steam output shall be controlled by a microprocessor controlling an SSR to pulse the power to the electrodes. The SSR shall be protected with a cooling fan and thermal overload switch requiring manual reset. 22. Humidifier shall have the ability to maintain a set water temperature during periods of no humidification demand in order to keep restart times at a minimum. 23. Each humidifier shall have a built in serial adapter connection allowing future interface to computer or EMS systems if required. This shall be complete serial communication of all set-points, status and alarms, not just acceptance of a modulating signal. Manufacturer shall have available graphic monitoring/control software capable of running in Windows. 24. The humidifier controller shall have a built in USB port to be used for software updates, log file and alarm history extraction. Copyright CAREL USA 3 +03U221775 Rev. 2.2 20160810

25. [Optional] The humidifiers shall be provided with a direct [remote] mount Room Distribution Unit for direct discharge of humidifying steam into the area to be humidified. 26. [Optional] The humidifier shall be able to accept an outdoor reset temperature sensor and automatically reset the relative humidity set point based on outside temperature conditions to prevent building condensation. 27. The humidifier must be able to accept a second humidity sensor input for use in the supply air duct, and incorporate control logic to reduce the capacity of the humidifier in response to approaching the high limit sensor set point. This feature is necessary for VAV operation. 28. Humidifier shall be ETL, cetl or UL, cul listed. 3. Installation 1. The humidifiers shall be installed as per the plans and drawings, connected to a cold water feed line, and a hot water drain line and electrical service sized appropriately for the maximum current draw of the unit. All wiring shall be in accordance with national and local electrical codes. 2. Manufacturer shall supply a duct mounted air flow proving device to prevent system operation on loss of air flow. 3. Manufacturer shall supply a duct mounted high limit humidistat to prevent condensation in the duct. GENERAL OPERATING SEQUENCE AND CONTROL 1. All humidity sensors shall continuously send their signals to the humidifier for processing and indication. 2. On a signal indicating a requirement for humidity, the humidifier shall read the feed water conductivity and initiate the diagnostic sequence. Upon completion, the conductivity shall be entered into memory to control the steam generator flushing cycle and the power contactor shall be energized. The fill valve shall be activated as required to reach output and replenish water being boiled off or drained. 3. If the humidifier is operating on modulating control, it shall track with the control signal; adjust capacity as required to supply the humidity requirements. Tracking with the signal shall be immediate, without delay. 4. The humidifier shall incorporate "adaptive intelligence" to prevent it from hunting and reduce fluctuations to minimum automatically zeroing to the setpoint. 5. The humidifier shall automatically monitor the heating elements in the steam generator to indicate when the steam generator is approaching its maintenance time, but without shutting down the humidifier. Copyright CAREL USA 4 +03U221775 Rev. 2.2 20160810

4. EXECUTION GENERAL 1. Install the humidifiers as detailed in the installation drawings and schedules and/or as recommended by the manufacturer. 2. Manufacturer to furnish complete submittal drawings before installation and operating manuals after. 3. Humidifiers shall be the Carel HeaterSteam series electric element steam humidifiers as manufactured and distributed by: 385 South Oak Street Manheim, PA 17545 Ph: 717-664-0500 FAX: 717-664-0449 Email: sales_usa@carel.com www.humidifynow.com Copyright CAREL USA 5 +03U221775 Rev. 2.2 20160810