SPRINKLER SYSTEMS UNDERCOVER-SPRINKLERS. Undercover-Sprinklers recessed and concealed sprinklers

Similar documents
Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

Minifog EconAqua Water mist sprinkler systems

Case study: EconAqua water mist sprinkler system

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

...extinguish it with a water spray.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

Tail-end valve stations

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Extended Coverage Sidewall Sprinklers

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

The Series LFII (TY3596) Residential

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

Microfast quick response Fusible element hsw sprinkler

TECHNICAL DATA OBSOLETE

CAPILLARY SAMPLING INTRODUCTION. Page 1 CAPILLARY SAMPLING

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

The green and friendly entrance. Comfort air curtains Model CA 2

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Automatic Sprinklers

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

CASSETTE UNIT. Comfort Circle

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

B. Section Identification for Fire Suppression Piping and Equipment.

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

SENJU SPRINKLER CO., LTD.

Submittal Packages Detailed with Items and Reviewers

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

STANDARD/quick. Sprinkler 42o. August 8, 2011

Data Sheet 4.24 Issue F

Standard Spray concealed horizontal sidewall sprinkler VK481

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Procedure for the Approval of New Fire Detection and Alarm Technologies

Non-Storage / Special Protection / Storage Sprinklers

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Data Sheet 4.16 Issue D

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Transcription:

SPRINKLER SYSTEMS UNDERCOVER-SPRINKLERS Undercover-Sprinklers recessed and concealed sprinklers

NOTICEABLY well designed Sprinklers from the Minimax Undercover product range are the perfect solution when it comes to integrating a fire extinguishing system into a ceiling unobtrusively and harmoniously. They are exactly what is required when high aesthetic standards need to be met in prestigious settings such as luxury hotel rooms, museums, showrooms of department stores or offices. Architects and clients with a keen eye for design invariably consider conventional sprinkler heads and traditional escutcheons that protrude from the ceiling to be unattractive and highly conspicuous. Virtually flush with the ceiling and available in a surface finish to match your interior design, the innovative Undercover-Sprinklers open up a whole host of new interior design opportunities. In addition, they continue to meet the official prerequisites for planning permission to be granted and for premium rebates on fire insurance to be guaranteed. Installation Undercover-Sprinklers can be installed wher - ever there are suspended ceilings (e.g. gypsum board or AMF ceiling systems) and solid concrete ceilings (e.g. exposed concrete) with enough available space for the sprinkler housings. These are not installed until the ceiling has been completed and are then seated flush with the ceiling. The height can then be adjusted by up to 15 mm. Undercover-Sprinklers fit onto all standard arm pipes with drops or flexible stainless steel hoses. Once the sprinkler has been installed, the hydraulic pressure test of the pipe network can be conducted before the suspended ceiling is put in place. Office buildings Museums Examples of areas of application for Undercover-Sprinklers

UNNOTICEABLE and flush with the ceiling Highly reliable There are a number of reasons why Undercover- Sprinklers are so reliable. For a start, there are no moving pieces or parts prone to corrosion. The ornamental ring or the fine-mesh cover are not positively soldered to the housings, but are attached magnetically. There are no vent holes in the Undercover-Sprinklers housings, and they can therefore not be inadvertently cooled down by the water from cavity sprinklers arranged above them. If you need a concentrated sprinkler arrangement, the stipulated minimum spacing between two Undercover-Sprinklers installed flush with the ceiling can be easily reduced without having to install baffles, for example. These sprinklers can even be installed in solid ceilings with no adverse effect on their response sensitivity. Attractive design We can meet practically any customer requirement when it comes to the colour of your sprinklers, even above and beyond the RAL colours, so that they will harmoniously blend in to their surroundings. The sprinkler housings and the suspended sprinkler come in a highly polished chrome finish as standard. The fine-mesh cover and the ornamental ring are available in a choice of white and highly polished chrome. Protected against soiling and damage The fact that they are recessed offers the sprinklers greater protection from being damaged by external influences, thus significantly reducing the likelihood of water damage caused by a damaged sprinkler. In addition, Undercover-Sprinklers are consequently less prone to soiling. In accordance with DIN EN 12259-1, concealed and recessed Undercover-Sprinklers have been issued with a CE conformity certificate by VdS Schadenverhütung GmbH.

ROUND-THE-CLOCK safety Recessed Undercover-Sprinklers Usually, up to half of the release element of a standard recessed sprinkler protrudes from the ceiling. Recessed Minimax Undercover-Sprinklers are currently the only recessed sprinklers known of to have a sprinkler deflector which is virtually flush with the ceiling. Consequently, they are often also referred to as being fully recessed. They are optionally available with a visually attractive ornamental ring and can be easily converted to concealed sprinkler. Concealed Undercover-Sprinklers With its fine-mesh cover and innovative CoverDrop eject mechanism, the Minimax Undercover-Sprinkler is unique amongst the known concealed sprinklers. Thanks to CoverDrop, the fact that the cover unsolders before the sprinkler is triggered does not have any bearing on the sprinkler s reliability. Low response sensitivity of the release element: RTI value < 50. Low response sensitivity of the release element: RTI value < 50. Recessed Undercover-Sprinkler Concealed Undercover-Sprinkler

INGENIOUS design SPRINKLER SYSTEMS UNDERCOVER-SPRINKLERS Design and function Cross section of an Undercover-Sprinkler Minimax has come up with two different types of the Undercover-Sprinkler a recessed and a concealed version. Unlike the concealed sprinkler with its fine-mesh cover and the innovative CoverDrop eject mechanism, the recessed Undercover-Sprinkler s head is visible through the optional ornamental ring. Both versions are equipped with the suspended quickresponse spray sprinkler, which is a tried and tested Minimax component. The sprinkler unit consists of the sprinkler itself, a base plate with a bayonet socket for attaching the housing, and a thread sleeve. Advantages The construction is carefully designed down to the smallest detail and comprises the following benefits: maximum functional reliability unobtrusive and attractive design recessed installation offers protection from soiling and damage Unique: CoverDrop eject mechanism The patented CoverDrop eject mechanism is based on two redundant mechanisms. A prestressed spring, held with soldered joint under tension, is fasten on the inside of the fine-mesh cover. When the soldering material s nominal release temperature is reached, this being below that of the sprinkler s release temperature, the prestressed spring is unleashed and the finemesh cover is ejected. If, under exceptional circumstances, the sprinkler should be triggered before the cover is ejected, the water released by the sprinkler is enough to dislodge the screen, thereby guaranteeing that the water is distributed evenly in all cases. Tested and approved: After successful completion of the VdS examinations, Minimax is now the first manufacturer of a VdS-approved concealed sprinkler.

IN USE everywhere Areas of application Undercover-Sprinklers are used in LH, OH1, OH2 and OH3 risk scenarios, as defined by VdS CEA 4001. These include: Banks Churches Department stores and shopping centres Hospitals, old people s homes and other care institutions Hostels, apartment blocks Hotels Libraries Multi-storey/underground car parks Museums Offices and administrative departments Official and governmental buildings Penal institutions and young offenders institutions Railway stations Restaurants Schools, universities and other educational institutions Minimax GmbH & Co. KG Industriestrasse 10/12 23840 Bad Oldesloe Germany Phone +49 4531 803-0 Fax +49 4531 803-248 E-mail info@minimax.de www.minimax.de No. S 89201 PB07We/10.06/5/09.08/HA