User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Similar documents
Zone Terminal, 2-fold, FM MT/U , GH Q R0111

ABB STOTZ-KONTAKT GmbH Webinar ABB i-bus KNX Security Module SCM/S

KNX / EIB Product Documentation Page: 1 of 81

User Manual. Security Systems Security System L208

OPERATING INSTRUCTIONS

Movement controller comfort, Flush-mounted (Up) xx, xx

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Operating instructions

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

0701 CO Light, HVAC, Monitoring, Brightness

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

KNX/EIB - Product database - Application description

Connections, displays and operating elements C D E G H. Installing the control unit

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

M2500 Engine Controller Installation Manual

2200 and 2200L ALARM CONTROL SYSTEMS

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Technical Manual MDT Motion Detector

Devices for Special Applications

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Description of the application programme for KNX occupancy detectors version 3.1

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Tebis application software

Installer Manual KNX Touchscreen Thermostat

Auro KNX Manual. Auro KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 23 v basalte

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

Fire Control Panel FS4000

Product and Applications Description


External Wireless Sounder

Wireless Keypad GKP-S8M

Contents. Glossary

DESCRIPTION OF KEYPAD (Access module with segments)

Independent Zone Control (I.Z.C.)

VAP304 PRO INSTALLATION & OPERATION MANUAL

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Use of the application program

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

ELT-KLED EliteSuite LED Keypad Installation Manual

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

2000 Series. Program Entry Guide. Control Panels

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Paradox Integration Module Settings Guide

UP 258E11 OPTISENS OFFICE

DOCUMENTATION IPS640

REPEATER FS5200R INSTRUCTION MANUAL

DOCUMENTATION IPS640

Webinar Competence Center Europe Building Automation

BURGLAR ALARM PANEL BS-468

The Challenger Version 8 User Guide

Security Technology KNX-Intrusion Alarm System L240 Installation, Commissioning, Operation

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

Using Your. Security System With LED Keypad S5030, S5031, S5032

Orion ISS. Intrusion and Fire Alarm Panel. Signal-10. User s Manual

Total Connect Box. User manual

Fire Alarm System FMS3000 Installation Instructions

A Beginners Guide to Inner Range Systems

TP4-20 GSM 4 TO 20 ZONES CONTROL PANEL WITH ON-BOARD GSM INTERFACE USER MANUAL EN EN EN /3 EN

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Remote alarm unit Art. Nr.:

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Contents: This manual is valid for control panel JA-82K The control panel can be configured by a PC running OLink software.

2. Safety. 4. Function

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

ALARM OUTPUT MODULE. Product #7736

Security System. User Guide for the LED Command Center

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

compact office 24V compact office 24V Lux

Installation & Operating Instructions

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Operating Manual MS220DA

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Solution Ultima 862 Operators Manual ISSUE 1.10

Contents: JA-83K control panel installation manual MKG51102

Challenger Series Users Manual

External Wireless Sounder

Instructions manual. By-alarm. By-alarm Manager software

Summary of Keypad Main User Commands

Viewguard Motion detctors PIR and DUAL detectors

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

Controller - 4 x 1-10 V outputs - BUS/KNX

Summit 3208GLD USER MANUAL. Electronics Line

Connections, displays and operating elements E F. 20s 3min

Integration Test Plan

Security System. User s Guide for the Text Command Center

SC-F3G User Manual 1.0

Committed to security

FIB_FGBS-001 Universal Binary Sensor

Smoke Detector and Siren. Manual

Local Control Network - building controls in perfection

Version 1.03 January-2002 USER S MANUAL

Interface and EOL Modules 8

Digiplex Control Panel (DGP-848) - V4.0

Control/Communicator Installation Manual

Transcription:

User manual ABB i-bus EIB Zone Terminal MT/S 4.12.1 Intelligent Installation System ABB STOTZ-KONTAKT

2

Contents Page 1 Device configuration..................................... 4 1.1 Introduction.......................................... 4 1.2 Wiring diagram........................................ 4 1.3 Functional description of the display....................... 5 1.4 Functional description of the inputs and outputs.............. 5 2 Application software..................................... 6 2.1 Description........................................... 6 2.2 Communication objects................................. 6 2.3 Zones A, B, C and D................................... 6 2.4 Set/Unset Request..................................... 7 2.5 Reset Zones A D..................................... 8 2.6 Supply Voltage Fault.................................... 8 2.7 Set confirmation....................................... 8 3 Parameters............................................. 9 3.1 Debounce time........................................ 9 3.2 Cyclical sending....................................... 9 3.3 Device status on return of bus............................ 9 4 Examples of application.................................. 10 4.1 Zone fault............................................ 10 4.2 Alarm devices......................................... 10 4.3 EIB bus monitoring..................................... 10 4.4 Parallel connection of zone terminals....................... 11 4.5 General notes......................................... 12 3

1 Device configuration 1.1 Introduction Zone Terminal MT/S 4.12.1 The zone terminal forms the interface between security sensors and the EIB. It is used for the connection of passive detectors (e.g. magnetic reed-contacts and/or glass-breakage sensors) to the ABB i-bus EIB and/or to connect potential free contacts in applications with increased security requirements. monitored cables Security sensors Zone terminal EIB components 1.2 Wiring diagram Detector contacts EOL resistor 2.7 kω To motion detectors EIB bus connection Power supply for detectors EOL = End of Line External 12 V DC SELV supply voltage 4

1.3 Functional description When the device is unset, the current status of the zones is displayed of the display via 4 LEDs. When the device is set, the LEDs are inactive. The current status of each zone is displayed again once the device is unset. The S/U LED displays the status of the zone terminal and the S/U output. The Test LED indicates the status of the Test output. 1.4 Functional description Zone inputs (terminals 1 to 8) of the inputs and outputs The device has 4 zone inputs (terminal pairs 1 2, 3 4, 5 6 and 7 8). The zones are designed to work with End of Line (EOL) resistors of 2.7 kω. To enable the zone terminal to function correctly, it is important to ensure that even unused zone inputs are terminated with a 2.7 kω resistor. This can be carried out directly at the input terminals. For information about setting up zones and the selection of sensors, the brochure Application Notes: ABB i-bus EIB Security and surveillance product range is available. S/U output (terminal 9) The voltage on this transistor output indicates the status of the zone terminal. Device set Device unset S/U output 12 V 0 V S/U LED OFF ON This signal voltage can be evaluated by specific detectors. It can be used, for example, by passive infrared detectors to activate the alarm storage function of the detector. Test output (terminal 10) The Test output is likewise a 12 V DC transistor signal output. The walk test function of passive infrared detectors can be activated using this signal. Walk test OFF Walk test ON Test output 0 V 12 V Test LED OFF ON This output is controlled via the ETS parameter Device status on return of bus, i.e. it is not possible to activate or deactivate the Test output via a bus telegram. Supply voltage inputs (terminals 11 and 12) The required 12 V DC SELV supply voltage is connected to these terminals (terminal 11: 0 V, terminal 12: + 12 V DC). Terminal 11 is also used as the common reference potential for the two outputs S/U and Test. 5

2 Application software 2.1 Description The application software Monitor Report Display / 1 makes it possible to implement security and surveillance functions using the EIB. 2.2 Communication objects The application software has eight 1 bit communication objects: two input objects for receiving input telegrams and six output objects. Only one group address can be assigned to each communication object. 2.3 Zones A, B, C and D Each zone has a separate 1 bit communication object that sends the status of the zone onto the EIB bus. Telegram value 0 Telegram value 1 Status of the zone OK Fault The mode of operation of these communication objects depends on the status of the zone terminal and the preceding events. Unset: In the normal unset mode, i.e. after a reset, the zone terminal sends a corresponding telegram each time there is a change in the status of the individual zones. Set: When the device is set, a telegram is sent once if a zone has a fault. Unset with stored alarm: If after the device has been unset, an alarm has been stored in one of more zones, no further telegrams are sent from the zones. The device only returns to the normal unset mode after a reset. 6

If no alarm is stored, once the zone terminal has been unset, the device reverts automatically to the normal unset mode. The following flow diagram represents the outlined functions: Normal unset Set Unset with stored alarm Reset Unset or set (no zones with faults) Unset ( 1 zone fault) Reset Zone = OK Zone LED = OFF S/U LED = ON Unset Zone = OK Zone LED = OFF S/U LED = OFF (zones without faults) Set Zone OK Telegram = 0 Zone Fault Telegram = 1 Zone Fault Telegram = 1 (alarm stored) Zone Fault Telegram = 1 no Zone = Fault Zone LED = ON S/U LED = ON Zone = Fault Zone LED = OFF S/U LED = OFF Zone = Fault Zone LED = ON S/U LED = ON Fault rectified? Zone Fault Telegram Zone OK Telegram Zone = Fault Zone LED = OFF S/U LED = OFF Zone Fault Telegram Zone OK Telegram Zone = OK Zone LED = OFF S/U LED = ON yes Zone OK Telegram = 0 2.4 Set/Unset Request With this communication object, it is possible to set or unset the zone terminal. When set, the LED display is switched off and the alarm storage function of the zone terminal is activated. The device can only be set if no faults are present. Device unset Telegram value 0 Telegram value 1 Device signals it is unset no fault 1 Device is set Fault 1 Device remains unset 2 Device set Device is unset no function 1 Fault: One or more zones have faults and/or there is a fault in the 12 V DC supply voltage. 2 Device signals it is unset: The signal is made via the communication object Set confirmation. 7

2.5 Reset Zones A D This communication object enables the zone terminal and its zones to be reset after: a fault in the zones while the device was set a fault in the supply voltage (= sabotage). A reset can only be carried out when the device is unset. Telegrams are only sent by the zones whose status has changed during the reset or by zones where there is still a fault after the reset. Telegram value 0 Telegram value 1 Device unset no function Device is reset Device set no function no function 2.6 Supply Voltage Fault The status of the 12 V DC supply voltage is indicated using this communication object. Cyclical sending: Via the parameter window, it is possible to select that this communication object sends telegrams cyclically for bus monitoring purposes. With this setting, the value 0 is continuously sent until a fault is detected. There after the value 1 is sent, regardless of whether the fault is still present or not. No cyclical sending: If a fault occurs, a telegram (value 1 ) is sent only once. The communication object is then disabled. In both cases, it is only possible to reset the fault indication by rectifying the fault and carrying out a reset of the zone terminal. Telegram value 0 Telegram value 1 Status of the supply voltage OK Fault 2.7 Set confirmation This enables the status of the zone terminal to be relayed back to the EIB bus. A telegram is only sent if: the status of the zone terminal has been changed by a set or unset command a set command could not be carried out successfully due to a fault Telegram value 0 Telegram value 1 Status of the zone terminal unset set 8

3 Parameters The following parameter window is displayed in the ETS program: 3.1 Debounce time With the parameter Debounce time, the bouncing of the detector contacts can be intercepted at the four zone inputs and unnecessary telegrams are blocked. A possible false alarm can thus be avoided 3.2 Cyclical sending Via the parameter window, the function Cyclical sending of the fault object can be activated or deactivated. The transmission interval is indicated in the parameters Time base for cyclical sending and Factor for cyclical sending. The time is the result of the product of the set values: transmission time = base for cyclical sending x factor for cyclical sending. It is recommended that a low base and the highest possible factor are given so that the set time is kept to as accurately as possible. Note: For security applications in which the EIB bus is to be monitored for interruptions, a transmission time of 10 s is recommended. (According to VdS guidelines, on recognition of an alarm signal, a warning must follow within 10 s). 3.3 Device status on After a bus voltage failure, it is possible to specify in this parameter the status return of bus of the zone terminal when the bus voltage is restored. The status of the zone terminal before the bus failure is not stored which means that earlier alarm signals are lost. Device set or unset Walk test ON or OFF 9

4 Examples of application 4.1 Zone fault In a typical installation, the individual faults of the zones should lead to a centralised alarm. This function can be implemented using a logic gate. Zone A Zone B Zone C 1 Zone fault Zone D 4.2 Alarm devices Local alarm devices, i.e. external sirens and/or flashing lights and silent alarm devices, e.g. telephone dialling systems should normally only be activated when the system is set. The following logic function only sends an alarm telegram if the system is set and there is a zone fault. Zone fault System set & Zone alarm The telegram System set is controlled directly by the communication object Set confirmation. 4.3 EIB bus monitoring If the communication object Supply Voltage Fault is set to cyclical sending, the transmitted telegrams can be used simultaneously for the monitoring of the supply voltage as well as for bus monitoring purposes (i.e. interruption of the bus). The status of the 12 V supply is given by the value of the transmitted telegram Supply Voltage Fault. The logic function shown below converts any telegram received (value 0 or 1 ) into a telegram with value 1. Supply voltage fault A A 1 AT/S Should a telegram not arrive within a specified transmission interval, e.g. due to an interruption of the bus (= sabotage), an alarm signal can be implemented, e.g. together with a binary output (application software autoreset ). 10

4.4 Parallel connection of In installations in which more than 4 zones are needed, it is possible to zone terminals connect zone terminals in parallel. In this case additional logic functions are required. Important: If zone terminals are connected in parallel, the installation functions slightly differently to an individual device. This affects the behaviour of the devices during fault storage. If a device detects a fault while it is set, no further telegrams are sent once it has been unset. In comparison, the other devices in the installation which have not detected a fault all revert back to the normal unset mode once they have been unset. Telegrams are sent out as normal should there be a fault in a zone. This means that the storage of alarms can be invalidated under certain conditions if, for example, it is not possible to distinguish between current and stored alarm signals. The following diagram represents the connection of two zone terminals. 4 4 Zone fault Zone terminal Zone terminal 1 2 Reset Set/Unset Set confirmation 2 Set confirmation 1 System set The telegram System set is produced by a logical AND connection of all Set confirmations. If no System set telegram is received after an attempt to set the system, i.e. no telegram with the value 1 has been sent, this means that at least one device has a fault. The other devices are set however. In order to give the whole installation a defined status, a manual unset telegram must be sent. This can however also be done automatically using the following additional logic function (application software Filter Switch / 1). 11

Filter value 1 Set confirmation 1 Input Output Enable Set confirmation 2 Input Output Enable Set/Unset In order to activate the system, a telegram set/unset with the value 1 is sent as usual. The value 1 also allows the filter gates to be enabled which have been programmed so that they only allow the value 0 to pass through. Once the set telegram has been received, the zone terminals report back either with the value 1 (set) or 0 (unset). Should all the zone terminals report back with the value 1, the filter gate outputs remain inactive. The whole system is now set. Should a zone terminal report back with the value 0, the telegram that is received at the filter gate input is allowed to pass through and is routed into the system as an unset telegram. All the zone terminals are thus immediately unset again. 4.4 General notes If more than two zone terminals are connected in parallel, the design of the external control logic function can be complicated. The increase in telegram interchange must therefore be considered as this can quickly lead to overloading of the bus and possibly to malfunctions. If several logic modules are used to implement the external logic function, it is recommended that time delay parameters are assigned to the output telegrams (if available in the application software). This prevents telegrams from being sent before all the telegrams have been received and evaluated at the input all the logic gates from simultaneously attempting to send telegrams and thus overloading the bus. Druckschrift-Nr. G STO 3052 98 S0001 ABB STOTZ-KONTAKT GmbH P.O. box address: Postfach 10 16 80 D-69006 Heidelberg Phone: + 49 (0) 62 21 701-774 Fax: + 49 (0) 62 21 701-723