Solar Powered Wireless Photobeam Sensors

Similar documents
No Touch Door Release Exit Sensor ACA-NTEB

Home Theater Interface Plate INSTALLATION INSTRUCTION

Twin Photobeam Detectors Manual

Radio Frequency Do s & Don ts

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Long-Range Barrier Sensors

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

CD6102 / CD6102 OC / CD6102-2

VX SERIES Wireless Thermostat with Occupancy Sensor

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

installation & operation manual

Whynter Portable Ice Maker 33 lb capacity - White

Robotic Vacuum. Operation Manual P4900

FLCH4R Garage and Utility Electric Heater

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

Classic & Deluxe Pants Press SPP-0669 SPP-0670

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INTELLICRISP WAFFLE MAKER INSTRUCTION MANUAL MODEL: CKCLWF1. Calphalon_WaffleMaker_IB_SPEC_DarkGrey_CKCLWF1_19EM1.indd 1 1/25/19 09:30

MaxLite LED Vapor Tight Linear Fixture

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

ETLW7. Product: 7kg Top Load Washing Machine. User Manual

LMA LINE MONITOR ALERT USER S MANUAL

52 CEILING FAN. Owner s Manual Models #50336, 50337

52 STRATHMERE CEILING FAN

20 High Velocity Fan with 135 Tilt Head

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

MERCURY HD-22 AUTOSCRUBBER Safe Operations

Thermometer model 02059

PIR Sensor. User s Guide

Instruction Leaflet. Read instructions before operating. Retain for future reference.

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Active Infrared Multi Beam Sensors. R Series

48 TAYLOR CEILING FAN

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Projection Alarm Clock USER GUIDE

Instruction Leaflet. Read instructions before operating. Retain for future reference.

ion Genesis Pump Controller

User Manual. Juice Extractor MODEL: WJE2BSLA

SWF2000-CN twin TRUSTED FOR OVER 100 YEARS. Window Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Digital Refrigerator/Freezer Thermometer model 00986

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Instruction Leaflet. Read instructions before operating. Retain for future reference.

GAS-Mate. Combustible Gas Leak Detector

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

52 BERKSHIRE CEILING FAN

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

Active Infrared Multi Beam Sensors

Sound Cover [ , , , ]

Z-710. Instruction Manual SAVE THIS MANUAL- KEEP IT HANDY FOR QUICK REFERENCE READ INSTRUCTIONS BEFORE USING

2-Port alarmcharge Hub - Manual

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

FW-KP WIRELESS KEYPAD

Owner s Manual. PIR-1 IR Learner

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Owner s Manual & Safety Instructions

Long Range Radio Alarm Transmitter

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

42 Oscillating Tower Fan with Remote Control. OWNER S MANUAL Model # FC1-42R-03

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Owner s. 18 Misting MF18W. To view

PORTABLE AIR CONDITIONER OWNER S MANUAL

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

HI Industrial Utility Heater HI Soleus Air International

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Long Range Radio Alarm Transmitter

SYSTEM CONTROL KIT Model: CK-41P

USER MANUAL Table of Contents

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

TrueClean ToteCleaner

Pet Immune SAW PIR Motion Sensor

OIL FREE HEATER RADIATEUR SANS HUILE CALEFACTOR SIN ACEITE AQUECEDOR SEM ÓLEO

- Oscillating Table Model Fan

PORTABLE AIR CONDITIONER OWNER S MANUAL

640 Series Advanced Remote Vehicle Security System

Transcription:

Installation & Operating Manual Solar Powered Wireless Photobeam Sensors SWPB-50 SWPB-100 SWPB-250 SWPB-400 50ft 100ft 250ft 400ft Create a Virtual Wall with the photobeam sensors! FEATURES Detection Range: 50ft / 100ft / 250ft / 400ft (depending on model) Power Consumption: 200uA (fully charged sensors can operate more than 30 days without sunlight) Frequency: 315MHz RF Range: 2000ft / 600m open area Response Time: 50ms Powered by: Copyright 2012. All Rights Reserved. S-61 / S-62 / S-63 / S-64 R201205-V08

Please read the Manual before attempting to use this product. Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. CAUTION 1. Handle this product with care Avoid any shock or bumping of the product. Improper handling could damage the product. 2. Requires a proper operating environment This product is designed for outdoor use. The allowable temperature range for operation of this product is between -13 F ~ 131 F / -25 C ~ 55 C. 3. Check the power source voltage The power source voltage should be within the specified range. (Product must meet the specifications). 4. Objects and liquid entry Never push objects of any kind into this product as this may touch dangerous voltage points of short out parts that could result in a fire or electric shock. Never spill any kind of liquid on the product. 5. Servicing Do not attempt to service this product by yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all service to qualified servicing personnel. 7. Retain Instructions The safety and operating instructions should be retained for future reference. 2

PACKAGE COMPONENTS One (1) Photobeam Transceiver One (1) Photobeam Receiver Two (2) Metal Mounting Plates Two (2) Metal Mounting Plate Screws Two (2) Pole Mounting U-Brackets Four (4) U-Bracket Screws Two (2) Jumpers Two (2) View Finders One (1) Test Paper One (1) User Manual For any returns, please include all components listed above with original packaging in Resalable Condition. Absolutely No Returns will be accepted if any component is missing/damaged. DIMENSIONS Units: mm 3

PARTS & FUNCTIONS 1. Front Cover 2. Optics Lens 3. Tamper Switch 4. J1 Jumper 5a. Local Solar Panel 5b. Local Solar Panel Connector 6. Power Switch 7. BAT Test Key 8. LED Indicator 9. Vertical Adjustment Screw 10. Main frame 11. Buzzer (for Receiver only) 12. View Finder 13. Metal Mounting Plate 14. Metal Mounting Plate Screw 15. U-Clamp Bracket 16. U-Clamp Bracket Screws 17a. External Solar Cell Charger 17b. External Solar Cell Charger Connector 4

APPLICATION DIAGRAM POSITIONS NOT SUITABLE FOR INSTALLATION Don t install the sensors to an unstable surface. It s necessary to avoid direct sunlight of sunrise and sunset. Don t install the sensors in the area where there are seasonal trees growing. Installation position should be suitable for alignment vertical +/-5 horizontal +/- 90. Don t install the sensors near corrosive. Don t soak it in water. 5 It s necessary to test the system after installation.

Multiple sets of the photobeam sensors can be used for longer distance guard.refer to the above figures to avoid mutual disturbances. When two sets of photobeam sensors are used in the same side, J1 should be short-circuited for one of the two sets. ALIGNMENT Remove the front cover, and turn on the power switch, the LED indicator of the transmitter flashes 3 times. The receiver s LED indicator flashes 3 times and the buzzer beeps di,di,di. Install the view finder as shown above and push it to the end. Observe at a 45 angle. 6

Make the photo of transmitter/receiver in the center of the view finder by vertical and horizontal adjustment. First adjust the transmitter, then adjust the receiver the beep sound (di,di,di) will be heard when alignment is successful. Put the test paper before the receiver and repeat alignment until the beep sound (di, di, di) can be heard again. Align vertical screw to desire position. After successful alignment remove the view finder, and then install the front cover. 7

INSTALLATION Note: Due to various pole sizes, the installation instruction below is recommended for poles with a diameter of about 1.18 / 30mm. Visit your local hardware store if additional materials are required for mounting the photobeam sensors on a larger sized pole. A. Pole Mounting 1. Pull the two bottom corners of the front cover outward and remove the front cover. 2. Fix the metal mounting plate and U-Clamp bracket with screws 3. Screw the mainframe to the metal mounting plate. 4. Place the cover back over the mainframe. 1. 2. 3. 4. 8

B. Wall Mounting 1. Pull the two bottom corners of the front cover outward and remove the front cover. 2. Fix the metal mounting plate to a wall with screws. 3. Screw the mainframe to the metal mounting plate. 4. Place the cover back over the mainframe. 1. 2. 3. 4. 9

TROUBLESHOOTING Trouble Reason Solution Transmitter LED indicator does not flash when power is on The energy stored is not enough to support the system on. Receiver LED indicator does not flash, and buzzer does not beep when power is on Detection range is not enough False Alarm Alarm Failure 1. Alignment is not optimum. 2. Stored power is low. 1. The base was not installed properly 2. Alignment is not optimum. 3. Batter power is low. 4. Front covers are polluted. 5. There is some moving object between the transmitter and receiver. 1. The signal of the transmitter is reflected to the receiver. 2. Other transmitter s signal are interfering with the receiver. 3. Battery power is low. Press BAT TEST key to check if there is enough stored energy. IF LED is not lighted, put it under the sunlight and check it next day. Without the front cover, charging is quickly. 1. Confirm proper installation of the viewfinder and optimize alignment with the test paper. 2. This problem can be fixed after sitting out in direct sunlight. 1. Select a firm installation base strong enough to withstand wind. 2. Optimize alignment with the test paper. 3. Let photobeam sit out in direct sunlight to recharge. 4. Clean the front covers. 5. Clear away any object blocking photobeams. 1. Because of the reflection, do not select long distance model for indoor use. Change the installation positions of the transmitter to avoid reflection. 2. Change the other transmitter s installation position. 3. Let photobeam sit out in direct sunlight to recharge. 10

SPECIFICATIONS Model SWPB-50 SWPB-100 SWPB-250 SWPB-400 Detection Range 50ft 100ft 250ft 400ft Detection Method Twin beam infrared pulse, alarm only when all beams are broken Response Time 50ms Power Input Power Consumption LED Indicator Buzzer Alarm Output Frequency RF Range Tamper Switch Alignment Angel Mounting Operation Temperature Dimension Weight Solar energy 200uA (the full charged system can work continuously more than 30 days without sunlight) 1. Flash 3 times when power on 2. LED on in alarm condition (Receiver only) 3. Flash 1~9 times when alignment is successful (receiver only) Receiver only 1. Beep dididi when power on. 2. Beep di, di ---- when alignment is successful, then stop beeping. 3. Beep di per 10 seconds when alignment is not successful. Wireless RF Transmission to Wireless Receiver SWPBR 315MHz 2000ft / 600m open area Valid Vertical 10 (+ / - 5 degrees) Horizontal 180 (+ / - 90 degrees) Wall Mounting or Pole Mounting -13 F ~ 131 F / -25 C ~ 55 C 2.874 x 3.3465 x 7.0866 / 73mm x 85mm x 180mm 1.4 lbs * Specifications are subject to change without notice 11

LIMITED WARRANTY LIMITED ONE (1) YEAR WARRANTY AND EXCLUSIONS Manufacturer warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Manufacturer is free of defects in materials and workmanship under normal and proper use for one (1) year from the purchase date. Manufacturer's only obligation is to correct such defects by repair or replacement, at its option, if within such one (1) year period the product is returned prepaid, with proof of purchase date, and a description of the problem. This warrant excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is voided if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other implied warranties of any kind, including merchantability and fitness or a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warrant, including merchantability and fitness of or a particular purpose, is limited to one (1) year. Manufacturer is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, loss sales or profits or delay or failure to perform this warranty obligation. The remedies, provided therein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. RELATED ACCESSORIES Solar Powered Wireless Signal Repeater SWPREPT Solar Powered Wireless Siren SWSIREN 1 Zone Non-Supervised Wireless Receiver with One Alarm Output SWPREC1 External Solar Cell Charger SWEXCELL One Zone Fully Supervised Wireless Receiver VS-MCR-304 4 Zone Fully Supervised Wireless Receiver VS-MCR-308 12