Hg5 HV Amalgam Separator Installation and Operations Manual

Similar documents
NXT Hg5 Amalgam Separator Installation and Operations Manual

NXT Hg5 mini Amalgam Separator Installation and Operations Manual

Hg5 Amalgam Separator Installation and Operations Manual

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

THAN 6 OR GREATER THAN 10 WILL VOID THESE WARRANTIES.

Syclone Amalgam Separator Installation and operating guide

Owner s. 18 Misting MF18W. To view

Industrial Vacuums, Inc

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Xaact Spot. Xaact Hot Spot

Owner s. Coolerr. comply. To view

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

TUBULAR LLdia-PUMPyy INSTRUCTIONS

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

A2Z Ozone, Inc. PRODUCT MANUAL


WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

Owner s Manual. Terpene Trap CF 1000

FLASH XTRACTOR II NEXT GENERATION SUB-SURFACE FLOOD EXTRACTION TOOL AC002

O w n e r s M a n u a l

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

C-Box 100, H-Box 200 & H-Box 500

Wax Base Heater & Dispenser

MDV. Mixing Degas Vessel. For Spa Ozone Generators Installation & Operations Manual Rev.C

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

Ozone + UV Sanitation

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

O w n e r s M a n u a l

OWNE R S MA N UA L. Made in USA. September 2015

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

OWNER S MANUAL & WARRANTY

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

Nilfisk Model VHS255 Drum Top Vacuum

Home Theater Interface Plate INSTALLATION INSTRUCTION

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC015 - AC016 - AC018

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

2001 Smith Eastern Corporation

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

Manual Parts Washer. Operating Instructions & Warranty Information

MODEL 7000 SUCTION UNIT

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

ion Genesis Pump Controller

REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return

IMPORTANT! ank You! Model: Twist-In 100 GPD, 3-Stage RO Unit. Installation, Operation & Maintenance Guide

Owner s Manual Hydro-X Vacuum Pac

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

2h 4h 6h. Ultrasonic Humidifier CAUTION: READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION.

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

ispring Whole House Water Filter Systems USER S MANUAL

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

No Touch Door Release Exit Sensor ACA-NTEB

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

Owner s Manual. For the Fuller Brush PORTABLE CANISTER Vacuum. Model FB-GIM

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

LS205EB INSTALLATION/OWNERS MANUAL

Part Number DOMESTIC. HyPerSteam Atmospheric Convection Steamer BETA 1.0

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

USER MANUAL/Installation Instructions LRV-4

Washable HEPA Air Cleaner with PlasmaWave Technology

Manual Feed Slot Opening. Wastebin. Credit Card Casters

InstructIon Manual KrEs EQuIPMEnt stands

DUST FREE CARBON Whole House Air Purifier

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

ULTRASONIC humidifier

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS

NP317W

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS


Instructions for using your new Sprinkler Magician System

IW-25-2 Dehumidifier Installation & Operations. Manual

INSTALLATION PROOF REGISTER YOUR PRODUCT. for warranty claims STAMP. Dealer. Date. here. Please complete and return. For the dental office:

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

MERCURY HD-22 AUTOSCRUBBER Safe Operations

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

MaxLite LED Vapor Tight Linear Fixture

YOUR AROMATHERAPY DIFFUSER

V. (Versus ) Bare Floor Vacuum

Navigator Upright Vacuum NV70 Series

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

HW-17 Record Cleaning Machine Setup and Instruction Manual

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Transcription:

Hg5 HV Amalgam Separator Installation and Operations Manual

Thoroughly read and understand instructions prior to installing, operating and servicing the Hg5 HV Amalgam Separator. These instructions are also available on our website at www.solmetex.com.! WARNING The waste stream treated by the Hg5 HV is discharge from a dental vacuum system and as such may contain concentrations of solid and soluble mercury and silver. Always wear protective gear when handling full Hg5 HV collection containers (latex gloves, safety glasses or face shield) and dispose of per local regulations and codes. Full collection containers should be handled, stored and disposed of according to regulations applying to hazardous waste containing mercury. Any spills should be considered hazardous and should be handled in accordance with standard hazardous materials handling procedures. Solmetex Warranty Solmetex Hg5 HV Air Water Separators are warrantied against defects in material and workmanship for a period of two (2) years from the date of purchase, established by proof of purchase or formal warranty registration. During the warranty period, Solmetex will at its option repair or replace products that prove to be defective. Solmetex Hg5 HV Collection Containers are warrantied against defects in material and workmanship for a period of one (1) year from the date of purchase, established by proof of purchase or formal warranty registration. During the warranty period, Solmetex will at its option repair or replace products that prove to be defective. Labor, transportation and service charges are not included. Limitations of Warranty The warranty shall not apply to defects resulting from improper installation, maintenance, abuse, unauthorized modification, or operation outside of the environmental specifications for the product or damages that occur due to improper repackaging of equipment for return to Solmetex. Use of third party collection containers or line cleaners having a ph less than or equal to 6 or greater than 8 will void these warranties. 2 For a complete list of recommended cleaners, visit our website at www.solmetex.com. No other warranty is expressed or implied. Solmetex specifically disclaims the implied warranties of merchantability and fitness for particular purpose. Hg5 HV Amalgam Separator

Hg5 HV Amalgam Separator Initial Set-Up The Hg5 HV Amalgam Separator is a Type 2 device with a maximum flow of 2000 ml/min and maximum fillable volume of 1900 ml. Treatment Rooms Hg5 HV Inlet Tank Inlet DO NOT connect Hg5 HV to outlet of tank. Dry Vacuum Unit OR Functional with 15, 30, or 50 Gallon Tank and with Single or Dual Wet Ring Pumps Hg5 HV Outlet Pump Inlet DO NOT connect Hg5 HV to outlet of the water ring pump. Side view Inlet 28" Air Water Separator 14" Wall Mount Bracket Outlet Collection Containers www.solmetex.com 3

Hg5 HV Installation When choosing the location to mount the Hg5 HV Amalgam Separator, remember that you must leave room to: Complete the piping. Access the front and sides of the unit for collection container replacement. Have the unit mounted higher than the pump and drain. The wall mounted support bracket must be mounted to the wall prior to installation of the Hg5 HV Amalgam Separator. The support bracket should be stud mounted in order to support the filled weight of approximately 100 pounds. The inlet and outlet connections are 3 Schedule 40 PVC Pipe. It is recommended that flexible pipe couplings be used to connect the unit to the existing vacuum lines. Since pipe sizes can vary from site to site, bushings may be required to adapt the unit to the vacuum line piping at your facility. Remove all components from package(s) make sure you have everything, prior to proceeding. The unit is piped into the vacuum line between the treatment rooms and the vacuum source. The line from the treatment rooms is piped to the inlet of the Hg5 HV and the outlet is piped to the vacuum source. DO NOT connect the unit to the outlet of the separating tank (dry vacuum system) or water ring pump (wet vacuum system). Determine the location of unit with respect to existing plumbing; pump location, drain and ease of collection container change out. Mount the back plate to an existing wall using lag bolts. The structure and bolts should be capable of supporting 100 pounds. Mount directly into the studs using the pre-drilled holes in the backplate. If no studs are available, molly bolts may be used providing they and the wall are capable of supporting the load. After mounting the bracket, lower the Hg5 HV onto the bracket. It will sit between the two side supports. Use the four ¼-20 bolts supplied with the unit to secure the unit to the bracket. After the unit is installed, the two collection containers can be installed. (See included installation instructions). Write the installation date on each collection container. Complete the registration form and return to Solmetex. 4 Environmental Specifications: Overall Dimensions: 17.625 W x 28 H x 22.5 D One Hg5 HV will serve up to 20 chairs Minimize water lift height. Maximum Temperature = 120 o F (52 o C) Maximum Vacuum = 15 Hg (51 kpa) For Dental Use ONLY Hg5 HV Amalgam Separator

Collection Container Your collection container must be changed once every twelve (12) months or when the sediment level reaches the full line, whichever occurs first. Check the sediment level of the collection container weekly. Maintenance Line rinsing & vacuum line cleaners - cleaners should be non-foaming, deodorizing, sanitizing & have a ph greater than 6 and less than or equal to 8. Using line cleaners outside of this ph range will void the warranty. For a complete list of recommended cleaners, visit our website at www.solmetex.com. With Dental Vacuum Systems: Follow manufacturer s instructions. Plan to rinse no more than 5 chairs every 10 minutes. Limit the total maximum flow to the Hg5 HV during rinsing to 1 liter per minute. Rinsing too much or too rapidly can overfill the Hg5 HV and could affect the unit s efficiency. Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. Solmetex shall not be liable for any direct, indirect, special, incidental or consequential damages, whether based on contract, tort or any other legal theory. Service & Troubleshooting NOTICE Refer to Hg5 HV Collection Container Replacement & Recycle Procedure manual at www.solmetex.com for removal and replacement of container. Always wear protective gear when handling full Hg5 HV collection containers. Keep the vacuum system running during the entire collection container replacement procedure. These procedures should be performed only when no operatories are being used as loss of chairside vacuum may occur. The Hg5 HV is designed to provide years of trouble-free service, with minimal attention. In the unlikely event of system related problems, please review the review the following for product support. Q: Little or no vacuum at the hand piece. A: Check sediment level of collection container, if full change the collection container. If the vacuum gauge reads normal but there is little or no vacuum to the hand piece, there is probably a clog or a leak between the hand piece and the Hg5 HV. If the vacuum gauge reads lower than normal these are the possible causes: www.solmetex.com 5

Service & Troubleshooting (continued) Did you just replace the collection container? Yes: Check installation of the new collection container. If the vacuum is low there is a possibility that the O-rings on the collection container did not seal into the receivers. With the vacuum running, remove the collection container, check the O-rings and re-install per the collection container installation procedure. No: If you have a solids collection cup (installed by others) - check & clean or replace element/screen if necessary. Check operation of the vacuum pump. Check all flexible hose for kinks, breaks, or loose clamps. Check all connections for breaks or cracks. Listen for vacuum leaks. Q: Water in the upper chamber (Air Water Separator) A: Check sediment level of collection container, if full change collection container. Check the ph of vacuum line cleaner: if less than or equal to 6 or greater than 8 change collection container and line cleaner. Visit www.solmetex.com for a recommended list of cleaners. Call or email your dental dealer for support if the problem cannot be solved easily. Q: Solids reach full line of collection container: A: Change the collection container. Q: Solids are above full line of collection container: A. Change the collection container. Inspect the top chamber for solids. Q: Top chamber has some solids: A: System is backed up. Turn on vacuum Remove pins Tilt container towards outlet pipe to allow air into top chamber Place container back on and insert pins Q: Top chamber is full with solids: A: System is in bypass. Reduction in suction Solids released into waste stream and environment Top chamber needs to be replaced Top chamber needs to be recycled Q: The equipment/utility room has poor lighting: A: Bring a flashlight to check the container. Using a flashlight from the backside of the system and shining it forward will help determine the level of sedimentation. 6 Hg5 HV Amalgam Separator

Visual Inspection Log Visual Inspection Log Solmetex provides a Visual Inspection Log for weekly maintenance reporting. Online at: www.solmetex.com/visualinspectionlog. Use this log with the Hg5 Series of Amalgam Separators to ensure proper operation and maintenance. Visually inspect the collection container weekly to determine the level of solid waste. Collection container is replaced when solids reach the full line or once a year, whichever comes first. Office Name: Account Number: Date (MM/DD/YYYY) Signature 04.2017 www.solmetex.com 1.800.216.5505 www.solmetex.com 7

Clearly the leader in amalgam separation In 1999, Solmetex designed the Hg5 that has quickly become the industry standard in Amalgam Separation. We have extensive experience in water chemistry, chemical separation science, process engineering, high performance manufacturing as well as Federal, State and local regulations governing water and hazardous wastes. What makes Solmetex different is our Total Solution Provider concept integrating waste handling and recycling into our complete product line to provide a truly green set of solutions. Solmetex is the global leader and our Hg5 system is the gold standard in high performance amalgam separation. Solmetex LLC 50 Bearfoot Road Northborough, MA 01532 Hg5 HV Install Ops Manual 11.2017 800.216.5505