TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

Similar documents
TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

INTERNATIONAL STANDARD

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

AS/NZS IEC :2014

Photobiological safety of lamps and lamp systems

Amendment to Test Report

Test Report issued under the responsibility of:

This document is a preview generated by EVS

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

G4 Pulsed Fiber Laser

Important Safety Notice

Laser Safety Citations

Contains Nonbinding Recommendations. Draft Not for Implementation

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

TEST REPORT IEC MEDICAL ELECTRICAL EQUIPMENT

Policy Redesign Project. Laser safety. Table of Contents

Inspection Detail. General Questions for Laser Labs

Model No.: VS806-6N ( ) V~ 50/60Hz LED 6x4W

G4 Pulsed Fiber Laser

American National Standard for Safe Use of Lasers

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

KALDEWEI SKIN TOUCH WELLNESSPRODUKT

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

North Dakota State University Laser Safety

Rice University Laser Safety Manual

OWNERS MANUAL OPERATION GUIDE

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

Laser Safety Program

Class 1 laser beam sensor safe for your eyes

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Consumer Products Services Germany GmbH Türkheim Germany

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

Class 1 laser beam sensor safe for your eyes

w w w. p r o l i g h t. c o. u k USER MANUAL Order code: EQLA15

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Laser Safety Self-Audit Checklist

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

ANSI Z136.1-CDV Status on Updates for Next Revision & Work by TSC-4 Committee on Control Measures and Training

Test Report Iec En Household And Similar

Copy of marking plate:

64 Max IR Thermometer

Test Report No.: Page 2 of 14

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

Laser Safety Management

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

Lasers and Laser Safety

*For inquiries and questions about lasers, see the Yellow-Page.

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore Singapore

Page 2 of 14 Report Ref. No

Rutgers Environmental Health and Safety (REHS)

TEST REPORT IEC Safety of household and similar electrical appliances

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

NEED FOR LASER SAFETY

Class 1 laser beam sensor safe for your eyes

University of North Florida Laser Safety Manual. Environmental Health and Safety Department

ETSI TS V1.2.1 ( )

order code: EQLA08 user manual

ETSI TS V1.2.1 ( )

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

TEST REPORT IEC60529 Edition TD990426C02

INTERNATIONAL STANDARD NORME INTERNATIONALE

American National Standard

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Laser Safety Products. Edition 20

Light Detection and Ranging LiDAR and the FAA FAA Review and Reclassification of LiDAR systems

LASER SAFETY PROGRAM

See cover page See cover page

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

IECEE OPERATIONAL DOCUMENT

FLASHLIGHT ANSI STANDARDS

PURPOSE OF THE PROCEDURE

Test Report issued under the responsibility of:

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire

Draft ES V1.1.1 ( )

ZH0505-GR-HT N/A IEC60335_2_9H LCIE

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Laser Safety Program Manual

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

AS/NZS IEC :2013

TEST REPORT IEC Safety of household and similar electrical appliances

CATALOGUE LASER POINTERS

Transcription:

Test Report issued under the responsibility of: TEST REORT IEC 60825-1 Safety of laser products - art 1: Equipment classification and requirements Report Number.... : 50089797 001 Date of issue... : 2017.07.25 Total number of pages... 16 Name of Testing Laboratory preparing the Report : Applicant s name... : Address... : Test specification: TÜV Rheinland Shanghai Co., Ltd. Honeywell International Inc Honeywell Sensing & roductivity Solutions 9680 Old Bailes Rd, Fort Mill, SC 29707, USA Standard... : Test procedure... : Non-standard test method... : Test Report Form No.... : Test Report Form(s) Originator... : IEC 60825-1:2014 (Third Edition) CB Scheme IEC60825_1E ÖVE Master TRF... : Dated 2014-07 Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

www.tuv.com age 2 of 16 Report No. 50089797 001 Test item description... : Trade Mark... : Manufacturer... : Model/Type reference... : Ratings... : Barcode Scanner Honeywell International Inc Honeywell Sensing & roductivity Solutions 1980i, 1981i 1980i: DC 5.0V, 450mA; 1981i: DC 3.75V(Li-ion battery operated); Class 2 laser product

www.tuv.com age 3 of 16 Report No. 50089797 001 Responsible Testing Laboratory (as applicable), testing procedure and testing location(s): TÜV Rheinland Shanghai Co. Ltd TÜV Rheinland Shanghai Co., Ltd. Testing location/ address... : No.177, 178, Lane 777, West Guangzhong Road, Jing an District, Shanghai, China Associated CB Testing Laboratory: Testing location/ address... : Tested by (name, function, signature)... : Bright Guo / Cherry Sun Approved by (name, function, signature)... : Stanley Liu Testing procedure: TM/CTF Stage 1: Testing location/ address... : Tested by (name, function, signature)... : Approved by (name, function, signature)... : Testing procedure: WMT/CTF Stage 2: Testing location/ address... : Tested by (name, function, signature)... : Witnessed by (name, function, signature). : Approved by (name, function, signature)... : Testing procedure: SMT/CTF Stage 3 or 4: Testing location/ address... : Tested by (name, function, signature)...: Witnessed by (name, function, signature).: Approved by (name, function, signature)...: Supervised by (name, function, signature) :

www.tuv.com age 4 of 16 Report No. 50089797 001 List of Attachments (including a total number of pages in each attachment): ATTACHMENT 1 - hoto document (6 pages) Summary of testing: The product has been tested according to standard IEC/EN 60825-1:2014. The tests have been performed according to the following sequence: Determine wavelength λ. Determine angular subtense α of apparent source. Determine measurement conditions (distance, aperture stop, time base, AEL) Measure radiant power from laser diode under normal condition. Measure radiant power from laser diode under single fault condition. The product is classified as Class 2 laser product according to both IEC/EN 60825-1:2014 and IEC/EN 60825-1:2007. Tests performed (name of test and test clause): 5.4 Measurement geometry. Testing location: TÜV Rheinland Shanghai Co., Ltd. No.177, 178, Lane 777, West Guangzhong Road, Jing an District, Shanghai, China Summary of compliance with National Differences: The product fulfils the requirements of EN 60825-1:2014.

www.tuv.com age 5 of 16 Report No. 50089797 001 Copy of marking plate: Trade Mark on The roduct Model: 1980i Model: 1981i Laser Label

www.tuv.com age 6 of 16 Report No. 50089797 001 Test item particulars...: Classification of installation and use...: Class III Supply Connection...: DC supply...: ossible test case verdicts: - test case does not apply to the test object...: - test object does meet the requirement...: (ass) - test object does not meet the requirement...: F (Fail) Testing...: Date of receipt of test item...: 2017-07-04 Date (s) of performance of tests...: 2017-07-04 to 2017-07-07 General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided... : Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : Metro (Suzhou) Technologies Co., Ltd. No. 221 Xinghai Street China-Singapore Suzhou Ind. ark, Suzhou, Jiangsu rovince 215021,. R. China General product information: The Granit 1980i industrial scanner features full-range area-imaging technology capable of reading both 1D and 2D barcodes. The Granit 1981i wireless industrial scanner features full-range area-imaging technology capable of reading both 1D and 2D barcodes. Model difference: Note: The difference between models 1980i and 1981i are rated voltage and power supply mode. The test is based on model 1981i. An integrated laser pointer is used for aiming purpose while LED light is used for scanning the bar code.

www.tuv.com age 7 of 16 Report No. 50089797 001 The Barcode Scanner is class III equipment, which is only SELV circuit inside EUT, connected and supplied by USB port or battery. The Laser diode emission power is evaluated according to IEC/EN60825-1 in complying with Class 2 Laser product, the related marking and warning labels are attached on labels and User Manual. The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 50 C. The product is designed to comply with Class 2 Laser roduct requirement.

www.tuv.com age 8 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict 4 CLASSIFICATION RINCILES 4.3 Classification rules --- 4.3 a Radiation of a single wavelength Single wavelength used. 4.3 b Radiation of multiple wavelengths 1) Laser product emits at two or more wavelengths shown as additive in Table 1 2) Laser product emits at two or more wavelengths not shown as additive in Table 1 4.3 c Radiation from extended sources (see 5.4.3) Not extended source. 4.3 d Non-uniform, non-circular or multiple apparent source 4.3 e Time bases --- 1) 0,25 s Select for class 2 evaluation. 2) 100 s Select for class 1 evaluation. 3) 30000 s 4.3 f Repetitively pulsed or modulated lasers Continuous radiation. 1) Any single pulse 2) Average power for pulse trains 3) ulse duration t Ti... : Number of pulses N and C5... : 3) ulse duration t > Ti... : Number of pulses N and C5... : 4.4 Laser products designed to function as conventional lamps. measured at 200 mm distance from closest point of Not such laser product. Un-weighted radiance L measured at 200 mm distance (comparison with LT = 1 MWm -2 sr -1 under reasonably foreseeable single fault conditions. Evaluation of emission according to IEC 62471 series (optional): Standard applied (IEC 62471 series),..... : Risk Group...... : Labelling... : Classification of product based on accessible laser radiation (if no laser radiation accessible: Class 1).

www.tuv.com age 9 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict 5 DETERMINATION OF THE ACCESSIBLE EMISSION LEVEL and RODUCT CLASSIFICATION 5.1 Tests --- Compliance under reasonably foreseeable single fault conditions. 5.3 Determination of the class of the laser product... : For Class 1C: vertical safety standard applied with requirements for Class 1C. The built-in laser engine had been certified separately. Fault condition test considered in the laser engine test report. --- 5.4 Measurement geometry --- 5.4.1 General The built-in laser engine had been certified separately. 5.4.2 Default (simplified) evaluation Refer to laser engine CB test report. The laser engine is classified as Class 2 laser product according to both IEC/EN 60825-1:2014 and IEC/EN 60825-1:2007. Conditions applied... : Aperture diameter... : Reference point :... : Measurement distance... : (for each condition) --- 5.4.3 Evaluation condition for extended sources Conditions applied... : Most restrictive position... : (distance from reference point) Angular subtense of the apparent source and C6: (for each condition) 5.4.3 a Aperture diameters (for each condition).... : 5.4.3 b Angle of acceptance (for each condition)...:

www.tuv.com age 10 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict 6 ENGINEERING SECIFICATIONS (roduct is a component, Clause 6 should be considered in final system) 6.2 rotective housing --- 6.2.1 General --- rotective housing prevents access to energy levels in excess of the AEL for Class 1. rotective housing prevents access to energy levels equivalent to Class 4 and withstands exposures under reasonably foreseeable single fault conditions. Maintenance of Class 1, 1C, 1M, 2, 2M, or 3R (access to emissions of Class 3B or 4 is prevented). Maintenance of Class 3B product (access to emission of Class 4 is prevented). Class 2 laser product. 6.2.2 Service 6.2.3 Removable laser system (laser system complies with requirements of Clauses 6 and 7). Not removable laser system. 6.3 Access panels and safety interlocks --- 6.3.1 anel is intended to be removed during operation (or maintenance) and would give access to higher energy levels (see Table 13). Accessible emission (after removal of the panel) corresponds to product Class (designated by X in Table 13) Emission through the opening if interlocked panel of Class 1, 1C, 1M, 2, or 2M is removed (Emission < AEL of Class 1M or 2M). Emission through the opening if interlocked panel of Class 3R, 3B, or 4 is removed (Emission < AEL of Class 3R). Requirements regarding reasonably foreseeable single fault condition. 6.3.2 Override mechanism No such device provided. Behaviour of override in operation when the panel is replaced. Visible or audible warning for override mode. 6.4 Remote interlock connector 6.5 Manual reset 6.6 Key control 6.7 Laser radiation emission warning ---

www.tuv.com age 11 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict 6.7.1 Laser product is a 3R (λ<400 nm; λ>700 nm), 1C, 3B or 4 laser systems. 6.7.2 Audible or visible warning. Warning is failsafe or redundant. Viewing of the visible warning does not require exposure to emissions > AEL for Class 1M and 2M. 6.7.3 Operational control and laser aperture are provided with a warning device when they are separated more than 2 m from warning device. 6.7.4 Visible indication of output aperture if laser emission may be distributed through more than one output. 6.7.5 Switch for handheld Class 3R device must be depressed for emission (in lieu of emission indicator). 6.8 Beam stop or attenuator No beam stop or attenuation. 6.9 Controls 6.10 Viewing optics No viewing optics. a) Human access to laser radiation in excess of Class 1M prevented when the shutter is opened or attenuation varied. b) Opening of the shutter or variation of the attenuation prevented when exposure to laser radiation in excess of Class 1M is possible. 6.11 Scanning safeguard 6.12 Safeguard for Class 1C products a) Human access to laser radiation in excess of AEL for Class 1 measured under Condition 3 is prevented. b) Human access to laser radiation in excess of AEL for Class 3B measured through 3,5 mm aperture at 5 mm distance from applicator is prevented. 6.13 Walk-in access a) Means provided so that any person inside the housing can prevent activation of Class 3B or 4 laser hazards. b) A warning device provides adequate warning of emission to any person within the housing.

www.tuv.com age 12 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict c) Where walk-in access during operation is intended or reasonably foreseeable, emission of laser radiation that is equivalent to Class 3B or 4 while someone is present inside the enclosure of Class 1, Class 2 or Class 3R product is prevented by engineering means. 6.14 Environmental conditions --- - climatic conditions Considered, no climate conditions change can lead to higher laser radiation. - vibration and shock Considered, no environmental conditions change can lead to higher laser radiation. 6.15 rotection against other hazards --- 6.15.1 Non-optical hazards (product safety standard) See IEC 60950-1 test report: 15077054 001, 15077054 002, 15077054 003 - electrical hazards; - excessive temperature; - spread of fire from the equipment; - sound and ultrasonics; - harmful substances; - explosion; 6.15.2 Collateral radiation No collateral radiation 6.16 ower limiting circuit 7 LABELLING 7.1 General --- Labels durable, permanently affixed Labels clearly visible Reading of labels is possible without exposure to laser radiation in excess of AEL for Class 1. Colour combination Labelling impractical due to the size or design of the product. Class 2 laser product. Warning label Hazard symbol (Figure 3) Class 2 laser product.

www.tuv.com age 13 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict 7.2-7.7 Text on explanatory label or pictogram (laser class, warning text) Class 2 laser product. See copy of marking plate on page 5. 7.8 Aperture label 7.9 Radiation output and standards information See copy of marking plate. --- Max output of laser radiation...: Max. 1mW ulse duration...: Continuous radiation. Emitted wavelength(s)... : Name and publication date of the standard... : Measured: 655 nm; Declared: 630-680 nm IEC 60825-1: 2014. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No.50, dated June 24, 2007. 7.10 Labels for access panels --- 7.10.1 a) f) Labels for panels - warning wording used... : 7.10.2 Labels for safety interlocked panels - Warning wording used... : 7.11 Warning for invisible laser radiation... : 7.12 Warning for visible laser radiation... : 7.13 Warning for potential hazard to the skin or anterior parts of the eye - warning wording used... : 8 OTHER INFORMATIONAL REQUIREMENTS 8.1 Information for the user --- a) adequate instructions for assembly, maintenance and safe use and description of the classification limitations, if appropriate. Adequate instruction is provided in user manual and product label. b) additional warning for Class 1M and 2M c) laser beam parameters for radiation above the AEL of Class 1 Wavelength...: Measured: 655 nm; Declared: 630-680 nm --- Beam divergence... : Not specified ulse pattern... : (pulse duration, repetition rate, ) Continuous radiation. Maximum power or energy output... : Max. 1mW

www.tuv.com age 14 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict d) safety instruction for embedded laser products and other incorporated laser products. e) ME and NOHD for Class 3B and 4 laser products; For collimated beam Class 1M and 2M lasers the extended NOHD (ENOHD). f) information for the selection of eye protection. g) reproduction of all required labels and warnings. h) location of laser apertures i) list of controls, adjustments of procedures for operation and maintenance - and warning statement. j) information (compatibility requirements) about laser energy source if not incorporated. k) additional warning for Class 1, 1M, 2, 2M, and 3R regarding skin or corneal burns. l) Information for Class 1C products (e.g. warning that repeated application may pose a risk). 8.2 urchasing and service information rovided in the user manual. a) safety classification of each laser product stated in all descriptive material (e.g. brochures). b) adequate instructions for servicing available: warnings and precautions regarding exposure of laser emission above Class 1 maintenance schedule list of controls and procedures that could increase accessible emissions description of displaceable parts protective procedures for service personnel reproduction of labels and hazard warnings rovided in the user manual. rovided in the user manual. 9 ADDITIONAL REQUIREMENTS FOR SECIFIC LASER RODUCTS 9.1 Applicable other parts of the standard series IEC 60825 --- IEC 60825-2 (Safety of optical communication systems) IEC 60825-4 (Laser guards) IEC 60825-12 (Safety of free space optical communication systems used for transmission of information)

www.tuv.com age 15 of 16 Report No. 50089797 001 IEC 60825-1 Clause Requirement + Test Result - Remark Verdict 9.2 Medical laser products: Class 3B and Class 4 medical laser products comply with IEC 60601-2-22 9.3 Laser processing machines: Comply with IEC/ISO 11553 series. 9.4 Electric toys: Comply with IEC 62115 9.5 Consumer electronic products: Comply with IEC 60950 (IT-equipment) or IEC 60065 (AV equipment)

www.tuv.com age 16 of 16 Report No. 50089797 001 TABLE: Critical components information -- Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of conformity 1) Laser Engine Honeywell EX20, EX25 650nm, Class 2 laser product Supplementary information: IEC 60825-1:2014 CB by UL US-30013-UL Table1: List of test equipment used Clause Measurement / testing Testing / measuring equipment / material used 5 Wavelength Ocean Optics / HR4000-CG-UV- NIR Range used Next calibration date 200-1100nm Dec., 2017 5 ower sensor Newport 918D-UV Auto Sep., 2017 -- End of report --

ATTACHMENT 1 hoto Documentation Report No.: 50089797 001 Type Designation: See main test report Rev. 1 age 1 of 6

ATTACHMENT 1 hoto Documentation Report No.: 50089797 001 Type Designation: See main test report Rev. 1 age 2 of 6

ATTACHMENT 1 hoto Documentation Report No.: 50089797 001 Type Designation: See main test report Rev. 1 age 3 of 6

ATTACHMENT 1 hoto Documentation Report No.: 50089797 001 Type Designation: See main test report Rev. 1 age 4 of 6

ATTACHMENT 1 hoto Documentation Report No.: 50089797 001 Type Designation: See main test report Rev. 1 age 5 of 6

ATTACHMENT 1 hoto Documentation Report No.: 50089797 001 Type Designation: See main test report -- End of Attachment 1 -- Rev. 1 age 6 of 6