B6512 IP control panel, 96 points

Similar documents
B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B9512G Control Panels

B6512 IP control panel, 96 points

B4512 Control Panels. Intrusion Alarm Systems B4512 Control Panels.

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B3512 Control Panels. Intrusion Alarm Systems B3512 Control Panels.

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B5512 Control Panels. Intrusion Alarm Systems B5512 Control Panels.

B3512 Control Panels. Intrusion Alarm Systems B3512 Control Panels.

B4512 Control Panels. Intrusion Alarm Systems B4512 Control Panels.

B9512G Control Panel. Intrusion Alarm Systems B9512G Control Panel.

ICP-AMAX3-P2-BE Intrusion panel, fr/de/nl/pt

ICP-AMAX2-P2-EN Intrusion panel, fr/de/nl/pt

D7212GV4 Series Control Panels

ICP-AMAX3-P2-EN Intrusion panel, fr/de/nl/pt

B465 Universal Dual Path Communicator

B465 Universal Dual Path Communicator

AMAX panel Intrusion Alarm Systems AMAX panel hardwired zones / 2 areas / 64 user codes

ICP-AMAX4-P3-EN Intrusion panel, en/es/pl/sv

AMAX panel Intrusion Alarm Systems AMAX panel zones / 8 areas / 128 user codes. On-board voice dialer

D2212BE Control Panel

B465 Universal Dual Path Communicator

B440 Conettix Plug-in Cellular Communicator

AMAX3-P2ENG Intrusion kit, fr/de/nl/pt, GPRS

D2212B Control Panel. Intrusion Alarm Systems D2212B Control Panel. Eight on-board points. Up to 24 wired or wireless points

D7412GV3 Control Panel

D9412GV2 Control Panel

B8512G Control Panels

B9512G Control Panels

D7412GV3 Control Panel

Professional Series TriTech+ Motion Detectors with Anti mask

CC600PB Solution 144 Control Panel

FPA 1000 UL Analog Addressable Fire Panel

GEC Low-frequency Horn Strobes

FMC 210 DM Double Action Call Points

Professional Series LSN TriTech+ Motion Detectors with Anti mask

ISC PPR1 WA16x Professional Series PIR Detectors with Anti mask

System Sensor L-series indoor horn/ strobes

LH1 UC30E Music Horn Loudspeaker

Loudspeakers Line Isolator System

Blue Line Gen2 TriTech Motion Detectors

Blue Line Gen2 TriTech Motion Detectors

Conettix D6100IPv6 Communications Receiver/Gateway

Integrated Security Solutions

FPA 1000 Analog Addressable Fire Panels

LC4 Ceiling Loudspeaker Range

FPA 1000 Analog Addressable Fire Panels

Commercial Series TriTech+ Motion Detectors with Anti-mask

FAS 420 Series Aspirating Smoke Detectors LSN improved version

Integrated Security Solutions

LBB 1990/00 Plena Voice Alarm Controller

LBB 1990/00 Plena Voice Alarm Controller

FAP 520 Automatic Fire Detectors LSN improved version

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

AMAX Intrusion Alarm Systems System overview

FMC 420RW Single Action Call Points LSN improved

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

FMC 420RW Single Action Call Points LSN improved

Fireray5000-EN. Fire Alarm Systems Fireray5000-EN. Extended monitoring range. Up to 2 detectors per system controller

LA1 UMx0E Metal Column Loudspeakers

LA1 UMx0E 1 Metal Column Loudspeakers

LSN RF Fire Detection System

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

LH1 UC30E Music Horn Loudspeaker

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Control Panels D9412GV4/D7412GV4 v2.03. Installation and System Reference Guide

BIS - Overview and basic package V3.0

LC4 Ceiling Loudspeaker Range

Integrated Security Solutions. B and G Series Control Panels

Designed for integration. B Series and G Series Control Panels

Professional Series Intrusion Detector Knows when to alarm. Knows when not to. Back. Now Featuring Multi-Point Anti-Mask with Spray Detect

LBC 3200/00 Line Array Indoor Loudspeaker

FCS-8000-VFD-B Video-based fire detection

G Series Control Panels Quick Guide. September 2017

LBC 3011/x1 Panel Loudspeakers

B Series Quick Reference Guide Intrusion Small Commercial/Retail/Banking

FPA 5000 With Functional Modules

WARNING Important Safety Information

LBC 3210/00 Line Array Indoor/Outdoor Loudspeaker

LBC 3201/00 Line Array Indoor Loudspeaker

LB1 UMx0E Premium sound Cabinet Loudspeaker Range

DS7400Xi Addressable Control/ Communicator

Easy Series Control Panel ICP-EZM2

Control Panel-Based Alarm System

B and G Series Integrated Security Solution

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

MODEL FTGF2P (240 VAC)

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

G Series Control Panels Quick Guide. February 2017

TETRA Secury System funkwerk TSS: The future of professional mobile communication.

6 Advanced Programming

Buderus Oil Boilers. Buderus G115 & G215.

Control Panels B5512/B4512/B3512. en UL Installation Instructions

UltraSync Modular Hub

Control Panels B9512G/B8512G (B9512G E/B8512G E) Installation Manual

Control/Communicator

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Control Panels B6512/B5512/B4512/B3512 (B5512E/B4512E/B3512E) Installation Manual

CAMERAS DISPLAYS ALERTS TRANSCEIVERS ELECTRONICS

Transcription:

Intrsion Alarm Systems B6512 IP control panel, 96 points B6512 IP control panel, 96 points www.boschsecrity.com Provides p to 96 points sing a combination of hardwired or wireless devices for installation flexibility and p to 6 areas with perimeter and interior control On-board Ethernet port for Conettix IP alarm commnication and remote programming, compatible with modern IP networks inclding IPv6/ IPv4, Ato-IP, and Universal Plg and Play Installer-friendly featres for simple installation and commnications, inclding on-board USB for easy on-site RPS programming, pls spport for Remote Connect Service (not available in Erope, the Middle East, or Africa), and plg-in PSTN and celllar commnication modles for simple installation and commnications Remote Secrity Control (RSC) app which allows sers to control their secrity systems and view system cameras - remotely from mobile devices sch as phones and tablets Provides p to 4 access doors The B6512 integrates intrsion and residential fire, providing one simple ser interface for both systems. The B6512 provides p to 96 individally identified points that can be split into 6 areas. The control panel can commnicate throgh its bilt-in Ethernet port, or throgh compatible plg-in modles that can send events over the pblic switched telephone network (PSTN) or over celllar network commnications. With the B6512, yo can monitor doors, windows, and motion within areas like showrooms or those that hold inventory. Each ser can have a personalized passcode, a wireless keyfob, and a credential to control the system. Use programmable athority levels with restricted privileges to provide service, secrity, and cleaning personnel with fll or limited access. Use the three programmable otpts (expandable p to 91) to trn on lights or lock and nlock doors. Users can: Trn on the system to secre the stock room while yo condct daily bsiness. Perform tests to ensre yor system is working properly. Set yor system to alarm immediately if a door opens. Activate the Watch featre so a tone sonds whenever a cstomer enters. Set a schedle for yor system to atomatically trn on at closing time. Use wireless secrity options to cstomize yor system.

2 B6512 IP control panel, 96 points Add p to 4 doors of access control sing the B901 Access Control Modle. Central monitoring stations provide 24-hor system monitoring with access to vital services. Professional secrity personnel can test the system, monitor system activity, and alert the police, fire department, or other emergency response teams if necessary. Fnctions Programmable otpts Three programmable on-board otpts; one high crrent sing a relay, and two trigger otpts Otpt A, with a contact rating of 3 Amps, can spply p to 1.0 A total crrent from AUX PWR Otpts B and C sink p to 50 ma at 12 VDC For alarm-otpt patterns Programmable bell test Point response 20 cstom point indexes Selectable point response time Cross point capability Fire alarm verification Dangeros gas indicator incldes carbon monoxide (NFPA 720) Watch mode User interface Spervision of p to 12 keypads Cstom keypad text is flly programmable throgh RPS Fll fnction men inclding cstom fnctions Athority by area and 32 character name for each ser 14 cstom athority levels to restrict system featres that each ser can access Programmable primary and secondary langage by ser and keypad; select from English, Spanish, French, and Portgese Area configrations Link mltiple areas to a shared area sch as a lobby or common entryway. The shared area then atomatically trns On (arms) when all associate areas are armed and trns Off (disarms) when any one associate area is disarmed. For higher secrity applications, the Area Re-Arm featre garantees that areas are always rearmed, and are disarmed for no longer than a specific, configrable, amont of time (for example, service time). Cstom fnctions For added convenience, the installer can program cstom fnctions that allow cstomers to complete complex tasks with one simple action. For example, a cstom fnction can bypass a grop of points and arm the system, allowing the ser to perform these fnctions with one easy command. Users can activate cstom fnctions with a keypad, keyfob, token, or card, or the control panel can activate a fnction in reaction to a falted point, or atomatically throgh a schedled event (SKED). Passcode secrity Two-man rle. Reqires two people with two niqe passcodes to be present at the time of opening. Early ambsh. Allows sers to verify that the facility is safe by reqiring two passcodes. The control panel sends a dress event if the ser does not enter the passcode a second time after inspecting the premises. Dal athentication. Reqires two forms of identification before processing certain system commands, inclding trning off the system and opening doors. A standard system ser mst have a passcode, a credential (token or card), and appropriate command athority permissions. Door control Using the B901 Access Control Modle, the control panel provides a flly spervised access control soltion. The soltion offers 14 programmable levels of access athority. Athority for door access is controlled by the ser level, the grop of the ser, the time of day, the door state, and the area armed (On/ Off) state. Easy exit control The control panel changes from one On (armed) state to another withot trning off (disarming) the system. For example, if yo change the state from Part On (Perimeter Arm) to All On (Master Arm), the control panel complies and reports the change. Easy Exit Control redces the nmber of keystrokes, simplifying system operation. Programmable passcode-controlled men list Passcode-controlled shortcts provide sers only with the options and information pertinent to them, simplifying system operation. Flexible control The system provides the flexibility to choose added convenience or high secrity. For example, yo can restrict to a keypad's immediate local area trning on (arming) and trning off (disarming) the system with a passcode, even if the ser has access to other areas. This is particlarly sefl for high secrity areas, where a ser may have access to the area, bt wold prefer to only trn off (disarm) the area individally rather than with the rest of the system. Monitor Delay/Delayed Response Create a special point index that delays the reaction of a point for a specified time (p to 1 hor in mintes and seconds). This delay provides time for the specified condition to reset before activating any annnciation. The system can annnciate locally and send a report, if desired. When the system is armed, the point can respond like a normal point providing dal fnctionality. Use this featre to ensre that perimeter doors have not been propped open, or to monitor critical areas sch as compter rooms and safes, for example.

3 B6512 IP control panel, 96 points System sers The system spports p to 100 sers. Each ser can have a personalized passcode, a wireless keyfob, and a credential to control the system. Yo can assign passcodes to one of 14 cstomized athority levels in each area that can be restricted to operate only dring certain times. Programmable primary and secondary langage by ser and keypad; select from English, Spanish, French, and Portgese. Commnication formats The control panel prioritizes and sends reports to for rote grops. Network and phone commnications can se one of two commnication formats: Modem4, Contact ID. Each grop has a programmable primary and backp destination. The control panel provides flexible commnications for most central stations with reporting capabilities sch as: Individal point nmbers Opening or closing reports by ser and area nmber Remote programming attempts Diagnostic reports IP commnication The control panel can se on-board Ethernet to commnicate with a Conettix D6600 or a Conettix D6100IPv6 Commnications Receiver/Gateway. The control panel can optionally se a Conettix Plg-in Celllar Commnicator (B440/B441/B442/B443). Using Conettix IP commnication offers a secre path that incldes anti-replay/anti-sbstittion featres and provides enhanced secrity with p to AES 256-bit encryption (sing Cipher Block Chaining (CBC)). The control panel spports Domain Name System (DNS) for both remote programming and central station commnication. DNS provides ease of se, eliminating the need to se static IP addresses as yor reporting destination, and accommodates a simple soltion for central station disaster recovery. The control panel spports both IPv6 and IPv4 networks. Commnication paths The control panel accommodates p to for separate phone and for separate network paths to the central station receiver. When resetting alarms or trning a system on and off, the ser is identified by name and nmber. Personal notification The control panel can send text messages and emails for personal notification over Ethernet or sing a celllar commnicator. Yo can configre p to 16 destinations sing a combination of celllar phone nmbers and email addresses. The control panel sends notifications in the ser s programmed primary langage. Bosch Remote Connect (Clod) Remote Connect simplifies connections from RPS, and the Remote Secrity Control app, sing Bosch Clod services. This service creates a secre connection to the control panel withot specific roter settings or the need for a static IP address or DNS. Notice The Bosch Remote Connect service is not available in Erope, the Middle East, or Africa. Firmware pdates The system allows remote firmware pdates throgh Remote Programming Software (RPS) sing the RPS Firmware Update Wizard. The Firmware Update Wizard ses the on-board USB connection or the on-board Ethernet (IP) connection to transfer firmware pdates. The control panel can optionally receive firmware pdates from RPS sing a Conettix Plg-in Celllar Commnicator (B440/B441/B442/B443). Notice! Celllar firmware pdates reqire more time than Ethernet pdates and carrier data rates apply. Control panel pdates. Remotely pdate the control panel firmware for easy featre enhancements withot replacing ROM chips. Modle pdate spport. Remotely pdate the firmware on connected SDI2 modles for easy featre enhancements withot visiting each individal modle. A wide variety of inpt options Each point: Single 1 kω, single 2 kω, dal 1 kω (1 kω + 1 kω), and No EOL (end-of-line) (EOL) resistor options (for onboard and B208 inpts) Programmable for Fire, Intrsion, Access, Gas, and Spervisory devices Spports hardwired and wireless devices Spports IP cameras by Bosch as point and otpt devices IP camera spport The control panel can integrate directly with Bosch IP cameras, sing them as flly spervised points and otpts. Integration of cameras allows the camera s video motion detection to activate points on the control panel. The control panel s virtal otpts can be configred to trigger camera actions, inclding sending video snapshots via email. Video verification Ensre priority response by law enforcement and elimination of fines for false alarms throgh a sbscription to Bosch CBS video verification services. The services also optionally enable yor monitoring center to speak real-time to an intrder to deter frther damage to yor site.

4 B6512 IP control panel, 96 points Notice The CBS video verification service is not available in Erope, the Middle East, or Africa. Secrity and fire detection The control panel provides eight on-board points, and p to 88 additional off-board points (depending on model and expansion interfaces). Yo can program individal points to monitor some types of brglar alarms, fire alarms, and spervision devices. Event log The event log stores local and reported events. The event log incldes information sch as time, date, event, area, point, and ser. View the event log from a keypad or se RPS to remotely retrieve event information. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. The event log stores p to 1,000 local and reported events. Schedled events (SKEDs) The internal clock and calendar start individally schedled events (SKEDs). SKEDs perform several fnctions sch as trn on or off, relay control, or point bypassing. The control panel offers: Ten schedled events with p to 25 different fnctions Six opening windows and for closing windows Six ser grop windows Day-of-week, date-of-month, or holiday only schedles Two holiday schedles of 366 days (leap year) Programming Installers can perform limited programming on-site with a keypad (critical parameters; sch as accont IDs, central station and RPS IP addresses and phone nmbers, reporting formats, and more). They can also do fll programming on-site or remotely (attended or nattended) with RPS. A programmable system passcode prevents nathorized remote programming. Diagnostics Keypads and RPS offer diagnostic help for monitoring and trobleshooting. The diagnostics featres allow yo to view the stats of the wired and wireless devices. The featres provide the stats of the control panel and its connected devices, sch as firmware version, power, and missing conditions. View the stats of each area. Remote Secrity Control app The Remote Secrity Control (RSC) app allows sers to control their secrity systems remotely from their devices. Users can: Trn their secrity system On or Off Trn specific areas On or Off Control otpts for applications sch as lighting control View live video from Bosch IP cameras Grant access remotely by nlocking and locking doors The app reqires the installing dealer to create a Remote Access Profile for sers, and to install the profile on their devices. Bosch Video Management System integration With Bosch Video Management System (Bosch VMS) and an intrsion system, the VMS operator has a single ser interface to monitor and control the intrsion system combined with video srveillance. With Bosch VMS and a control panel, the operator can, for example: View videos triggered by intrsion events, inclding all relevant information sch as areas, point, and ser show in the display with the event. View areas, points, otpts, and doors with their statses on the Bosch VMS map, providing the exact location in the system. Trn on (arm) and trn off (disarm) areas. Bypass and nbypass points. Lock and nlock doors (Bosch VMS 6.0 and higher). Reqirements to integrate Bosch VMS with a control panel: A licensed Bosch VMS system sing Professional Editions v5.5 or higher or Bosch VMS Enterprise Edition v5.5 or higher. Expansion license to integrate the intrsion control panel. One license needed per control panel. Order nmber MBX-XINT-xx for the expansion license added to a Bosch VMS base license. Refer to the Bosch Video Management Software prodct page on the Bosch website, www.boschsecrity.com. Access to Remote Programming Software (RPS). Certifications and approvals Region USA Reglatory compliance/qality marks ANSI- SIA Astralia RCM ACMA CP-01-2010-Control Panel Standard - Featres for False Alarm Redction Erope CE EMC, LVD, RoHS [B6512, B5512, B5512E, B4512, B4512E, B3512, B3512E] USA [B6512, B5512, B4512, B3512] 294 - Standard for Access Control Units and Systems 365 - Police Station Connected Brglar Alarm Units 609 - Standard for Local Brglar Alarm Units and Systems 636 - Holdp Alarm Units and Systems 985 - Hosehold Fire Warning System Units 1023 - Hosehold Brglar Alarm System Units 1076 - Proprietary Brglar Alarm Units and Systems

5 B6512 IP control panel, 96 points Region Reglatory compliance/qality marks Enclosres CSFM FCC 1610 - Central Station Brglar Alarm Units 1635 - Standard for Digital Alarm Commnicator System Units see or website Part 15 Class B Canada C {B6512, B5512, B4512, B3512] C C C C C C IC Installation/configration notes Keypads CAN/C S303 - Local Brglar Alarm Units and Systems CAN/C S304 - Standard for Signal Receiving Center and Premise Brglar Alarm CAN/C S545 - Residential Fire Warning System Control Units CAN/C S559 - Fire Signal Receiving Centres and Systems C-ORD C1023 - Hosehold Brglar Alarm System Units C-ORD C1076 - Proprietary Brglar Alarm Units and Systems ICES-003 - Information Technology Eqipment (ITE) Notice Not all prodcts and featres are available in all regions. Conslt yor local Bosch representative for availability details. B942/B942W Toch Screen Keypad (SDI2) B930 ATM Style Alphanmeric Keypad (SDI2) B921C Two-line Capacitive Keypad (SDI2) B920 Two-line Alphanmeric Keypad (SDI2) B915/B915I Basic Keypad (SDI2) Power CX4010 Plg-in Transformer (18 VAC 22 VA 60 Hz) ICP TR1822 CAN Plg in Transformer (110 VAC primary, 18 VAC 22 VA secondary) DE-45-18 Transformer D126 Standby Battery (12 V, 7 Ah) D1218 Battery (12 V, 18 Ah) D122 Dal Battery Harness D122 Dal Battery Harness with long leads B10 Medim Control Panel Enclosre B11 Small Control Panel Enclosre B12 Monting Plate for D8103 Enclosre B8103 Universal Enclosre (reqires a B12) D8108A Attack Resistant Enclosre (reqires a B12) D8109 Fire Enclosre (reqires a B12) D8108A-CE Attack Resistant Enclosre with Bilt-in Transformer (reqires a B12) B-ENCL-1 Metal Enclosre Kit (incldes B12 and transformer) Accessories B56 Keypad Srface Mont Box B96 Keypad Trim Bezel B99 USB Direct Connect Cable B501-10 Interconnect wiring cables (pack of 10) Detectors FCC-380 Carbon Monoxide Detector F220-P: Photoelectric Smoke Detector F-220-PTH: Photoelectric/Heat Detector FCP-OT320 Mltisensor Detector Optical/Thermal FCP-O320 Optical Smoke Detector FCH-T320 Heat Detector Bosch conventional detectors, inclding Professional Series, Ble Line Gen2, Ble Line, Classic Line, Commercial Line, and Ceiling Mont motion detectors, as well as glass break, seismic, reqest-to-exit, photoelectric, heat, and smoke detectors. Modles B201 2-wire Powered Loop Modle B208 Octo-inpt Modle B308 Octo-otpt Modle B426 Conettix Ethernet Commnication Modle B430 Plg-in Telephone Commnicator B440 Conettix Plg-in Celllar Commnicator (sing 3G) B441 Conettix Plg-in Celllar Commnicator (sing CDMA) B442 Conettix Plg-in Celllar Commnicator (sing GPRS)* B443 Conettix Plg-in Celllar Commnicator (sing HSPA+)* B450 Conettix Plg-in Commnicator Interface B520 Axiliary Power Spply Modle B810 wireless receiver (RADION)

6 B6512 IP control panel, 96 points B820 SDI2 Inovonics Interface Modle B901 Access Control Modle D113 Battery Lead Spervision Modle D125B Dal Class B Initiating Modle D129 Class A Initiating Modle D130 Axiliary Relay Modle D132A Smoke Detector Reversing Relay Modle D133/D134 Relay Modle D135A Low Battery Disconnect Modle D185 Reverse Polarity Signaling Modle D192G Class B, Style Y Bell Circit Spervision Applications Remote Programming Software (RPS or RPS-LITE) v6.03 and higher Bosch Video Management System v5.5 and higher Remote Secrity Control (RSC) Conettix receivers (Managed and configred with Conettix D6200 Programming/ Administration Software v2.00) Conettix D6600 Commnications Receiver/Gateway (with only D6641 line cards installed) with CPU version 01.10.00 Conettix D6100IPv6 Commnications Receiver/Gateway with CPU version 61.10.00 Conettix D6100i Commnications Receiver/Gateway with CPU version 61.10.00 RADION wireless from Bosch B810 wireless receiver (RADION) RFBT-A/RFBT bill trap RFDL-11-A/RFDL-11 TriTech motion detector RFDW-RM-A/RFDW-RM recessed mont door/window contact RFDW-SM-A/RFDW-SM srface mont door/window contact RFGB-A/RFGB glass break detector RFPR-C12-A/RFPR-C12 PIR crtain motion detector RFUN-A/RFUN niversal transmitter Inovonics Wireless B820 SDI2 Inovonics Interface Modle ENKIT-SDI2 SDI2 Inovonics Interface and Receiver Kit. Incldes B820 and EN4200 EN1210 Universal Transmitter (Single-inpt) EN1210EOL Universal Transmitter with EOL Resistor EN1210W Door-Window Transmitter with Reed Switch EN1215EOL Universal Transmitter with Wall Tamper, Reed Switch, and EOL Resistor EN1223D Water resistant Pendant Transmitter (Doble btton) EN1223S Water resistant Pendant Transmitter (Single btton) EN1224-ON Mltiple-Condition Pendant Transmitter EN1233D Necklace Pendant Transmitter (Doble-btton) EN1233S Necklace Pendant Transmitter (Single-btton) EN1235D Beltclip Pendant Transmitter (Doble-btton) EN1235DF Fixed-location Transmitter (Doble-btton) EN1235S Beltclip Pendant Transmitter (Single-btton) EN1235SF Fixed-location Transmitter (Single-btton) EN1247 Glass-break Detector Transmitter EN1249 Bill Trap Transmitter EN1242 Smoke Detector Transmitter EN1260 Wall Mont Motion Detector EN1261HT High Traffic Motion Detector EN1262 Motion Detector with Pet Immnity EN1265 360 Ceiling Mont Motion Detector EN4200 Serial Receiver EN5040-T High Power Repeater with Transformer Parts inclded RFKF-A/RFKF two-btton keyfob Qantity Component RFKF-FBS-A/RFKF-FBS for-btton keyfob RFKF-TBS-A/RFKF-TBS two-btton keyfob RFPB-SB-A/ RFPB-SB single-btton panic RFPB-TB-A/RFPB-TB two-btton panic RFRP-A/RFRP repeater RFSM-A/RFSM smoke detector RFPR-12-A/RFPR-12 PIR motion detector 1 Control panel 1 Literatre pack: Installation Gide C Installation Gide (English and French) Owner s Manal Release Notes SIA Qick Reference Gide Qick Installation Gide 1 Literatre CD containing prodct literatre

7 B6512 IP control panel, 96 points Qantity Component Ordering information 1 Wiring label for enclosre door 1 Hardware pack: Monting clips 1 kω EOL resistors Battery wires For #6 x 3/4 in self threading screws Technical specifications Commnications Ethernet Environmental considerations 10/100 fll dplex Relative hmidity 5% to 93% at +90 (+32 ), non condensing B6512 IP control panel, 96 points Spports p to 96 points, 3 on-board otpts, and 6 areas for intrsion, residential fire. Order nmber B6512 Accessories B520 Axiliary power spply modle, 2A 12V Provides axiliary power to 12 VDC devices or to SDI2 modles. Order nmber B520 B201 2-Wire Powered Loop The modle provides a single powered initiating device circit. The modle spports compatible 12 V 2-wire smoke detectors. It also spports connecting brglary devices to the control panel. Order nmber B201 Temperatre (operating) Nmber of +32 F to +122 F (0 C to +49 C) B208 SDI2 8-Inpt Expansion Modle Provides 8 programmable inpts. Order nmber B208 Areas 6 Cstom fnctions 6 Events Up to 1,000 Passcode sers Points Programmable otpts RF points 88 Cameras 6 SKEDs 10 Power Reqirements Crrent draw (maximm) Otpt (alarm) Otpt (axiliary, continos power, and switched axiliary combined) Voltage (operating): 100, pls 1 Installer passcode 96 (8 on-board, p to 88 off-board and virtal) 91 (3 on-board, p to 88 off-board and virtal) Idle 125 ma; Alarm 155 ma 1.3 A at 12 VDC 800 ma at 12 VDC nominal 12 VDC nominal Voltage (AC) CX4010 Plg-in Transformer (18 VAC 22 VA 60 Hz) or ICP TR1822 CAN Plg in Transformer (110 VAC primary, 18 VAC 22 VA secondary) B308 SDI2 8-Otpt Expansion Modle Provides 8 programmable relays. Order nmber B308 B901 Door Controller Flly spervised, addressable SDI2/SDI bs device that allows access control integration for Bosch G and B Series Control Panels. Order nmber B901 B810 RECEIVER-SDI2 Receives RF signals from RADION transmitters, repeaters, and glassbreaks. Operates at 433.42 MHz. For se with compatible SDI2 bs control panels. Order nmber B810 D122 Dal Battery Harness Harness with circit breaker. Connects two batteries (in parallel) to a compatible control panel. Order nmber D122 Dal battery harness, 35'', 12V Harness with circit breaker and leads measring 35 in. (89 cm). Connects two batteries (in parallel) to a compatible control panel in a separate enclosre. Order nmber D122L D126 Battery, 12V 7Ah A rechargeable sealed lead acid power spply sed as a secondary power spply or in axiliary or ancillary fnctions. Order nmber D126

8 B6512 IP control panel, 96 points Battery, 12V 18Ah The D1218 is a 12 V 18 Ah sealed lead acid battery with two bolt-fastened terminals. It is sed for standby and axiliary power. It connects to a compatible control panel sing a D122 or D122L Dal battery harness. Order nmber D1218 CX4010 Transformer, plg-in, 18V 22VA For se in North America. 110 VAC primary voltage inpt. 18 VAC, 22 VA secondary inpt. Order nmber CX4010 ICP-TR1822-CAN Transformer, plg-in, 18V 22VA, Canada For se in Canada. 110 VAC primary voltage inpt. 18 VAC, 22 VA secondary inpt. Order nmber ICP-TR1822-CAN B8103 Universal enclosre, white White steel enclosre measring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). Order nmber B8103 D8103 Enclosre Grey steel enclosre measring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). Order nmber D8103 D8108A Attack resistant enclosre, large, grey Grey steel enclosre measring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). Listed. Incldes a lock and key set. Order nmber D8108A D8109 Fire Enclosre Red steel enclosre measring 16 in. x 16 in. x 3.5 in. (41 cm x 41 cm x 9 cm). Listed. Incldes a lock and key set. Order nmber D8109 B10 Steel enclosre, medim, white White, steel enclosre. Accepts an optional lock and tamper switch. Measres 35.6 cm x 31.8 cm x 7.6 cm (14 in x 12.5 in x 3 in). Order nmber B10 B11 Steel enclosre, small, white White, steel enclosre. Accepts an optional lock and tamper switch. Measres 27.8 cm x 25.9 cm x 8.32 cm (10.9 in x 10.2 in x 3.3 in). Order nmber B11 Monting plate for D8103 enclosre Reqired for monting select control panels and other devices in B8103, D8103, D8108A, D8109, and BATB Battery Box enclosres. Order nmber B12 Transformer enclosre kit, grey For applications that might reqire a remote transformer in an enclosre. Can be sed with B Series control panels and D9412GV4/D7412GV4 control panels. Order nmber D8004 D101 Lock and Key Set Short-body lock set with one key spplied. Uses the D102 (#1358) replacement key. Order nmber D101 D110 Tamper Switch Screw on tamper switch that fits all enclosres. Shipped in packages of two. Order nmber D110 ICP EZTS Dal Tamper Switch Combination tamper switch with a wire loop for additional tamper otpts. Order nmber ICP-EZTS B99 USB direct connect cable Male A to Male A USB cable for local programming of control panels with on-board USB ports. Order nmber B99 B915 Basic Keypad Two-line alphanmeric basic keypad with English fnction keys. Order nmber B915 B915I LCD keypad, icon keys, SDI2 Two-line alphanmeric basic keypad with icon fnction keys. Order nmber B915I B920 2 Line Alpha Nmeric Keypad (SDI2) Two-line alphanmeric keypad Order nmber B920 B921C Two-line Keypad w/toch keys, Inpts Two-line alphanmeric keypad with inpts and capacitive toch keys in black. Order nmber B921C B930 ATM Style-Alpha Nmeric Keypad (SD12) Five-line ATM style alphanmeric keypad Order nmber B930 B942 Toch Screen KP Prox/Inpt/Otpt, black Black SDI2 toch screen keypad with inpts and one otpt. Order nmber B942 B942W Toch screen KP, prox/inpt/otpt,white White SDI2 toch screen keypad with inpts and one otpt. Order nmber B942W

9 B6512 IP control panel, 96 points Software Options D5500CU Upgrade DVD RPS software is available for free download on the RPS prodct page. It is also available on DVD-ROM. Order nmber D5500CU B6512 IP control panel, 96 points Base license for Enterprise System. 2 Management Server sbsystems (1 reqired for Enterprise Management); 8 cameras; 2 workstations;1 CCTV keyboard; 1 DVR. All MBV-X* and MBV-F* options are only available with Base license. Order nmber MBV-BENT-70 B6512 IP control panel, 96 points Base license for Professional Edition. 8 cameras; 2 workstations; 1 CCTV keyboard; 1 DVR. All MBV-X* and MBV-F* options are only available with Base license. Order nmber MBV-BPRO-70 Represented by: Erope, Middle East, Africa: Germany: North America: Asia-Pacific: Bosch Secrity Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.secritysystems@bosch.com emea.boschsecrity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrnn Germany www.boschsecrity.com Bosch Secrity Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@s.bosch.com www.boschsecrity.s Robert Bosch (SEA) Pte Ltd, Secrity Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.secritysystems@bosch.com www.boschsecrity.asia Bosch Secrity Systems 2017 Data sbject to change withot notice 22491631627 en, V9, 22. Ag 2017