Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Similar documents
FT14 Ball Float Steam Trap (Screwed)

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

Liquid Drainers LIQUID DRAINERS

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Installation and Maintenance Manual

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

MFP14 Automatic pumps for condensate and other industrial fluids

SMK 22 SMK SMK SMK 22-82

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Inverted Bucket Steam Traps

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

THERMODYNAMIC STEAM TRAP

MFP14 Automatic pumps. for condensate and other industrial fluids

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

THERMOSTATIC STEAM TRAPS

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

STEAM TRAPS

LIQUIDATOR UMT-TD Series Thermodynamic

Model: 1100 Float-Controlled Condensate Trap, PN 25

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Spirax-Sarco Industrial Thermostatic Steam Traps

THERMODYNAMIC STEAM TRAPS

205 Control Installation and Maintenance Instructions

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

ESCO. Committed. Group of Companies. to help conserve Steam Energy

BK 46. Installation Instructions Steam Trap BK 46

CRU-S Series Stainless Steel Condensate Recovery Unit

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

CD-33/CD-33S Controlled Disc Steam Traps

Spiratec Steam trap monitoring

UNIVERSAL STYLE STEAM TRAPS WU450 Series

LIQUIDATOR 450 SERIES

THERMODYNAMIC STEAM TRAPS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

BK 45 BK 45-U BK 45-LT BK 46

Steam Traps and Steam Trap Testing

TITAN FLOW CONTROL, INC.

NON-SLAM DYNAMIC ARV FAF 7330

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

STEAM EQUIPMENT 4

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Operation, Maintenance and Installation Manual

INSTALLATION, OPERATION

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

INSTALLATION, OPERATION

Spiratec R16C Automatic Steam Trap Monitor

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Hoffman Specialty General Catalog

GESTRA. Program for Universal Connections. The Smart Solutions

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Disc Type Steam Trap TSD-42

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

INSTALLATION, OPERATION

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

TVA Flowmeter for Saturated and Superheated Steam Service Installation and Maintenance Instructions

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

CRU 200 and 500 Series Condensate Recovery Units

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Our Know-How. Your Peace of Mind. Steam Solutions

Why steam trap survey?

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

SECTION Pipeline Ancillaries

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

Technical Specification

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH7RH-B JH7.

Operating and installation instructions

EasiHeat Mechanical Installation and Commissioning Instructions

Steam Condensing Heat Exchanger SR-3 / SR-8

Temperature controller for steam (PN 25) AVT / VGS - external thread

Technical Specification

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

13-1. Temperature Regulator

HERZ Differential Pressure Control Valve 4002

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Product overview. the optimum components for every application

Transcription:

Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown) Description The IFT57 is an SG iron ball float steam trap having stainless steel working internals, an integral Spiratec sensor (SSI) for steam leakage detection and built-in automatic air venting facility for the prompt removal of large condensate loads from steam systems. The trap is supplied with integrally flanged connections and can be maintained without disturbing the pipework. Vertical flanged connections, designated are available. Flow direction for the horizontal trap is from right to left only when facing the body. For vertically orientated traps the flow is downwards only. The body and cover are produced by TÜV approved foundries. Available options: IFT57H - Horizontal flow. - Vertical flow. Sensors are compatible with Spiratec indicators, automatic monitors and test points: R1 (single trap) remote set point, R1 (1 trap) remote test point, Type 30 hand held indicator, R16C (16 trap) automatic steam trap monitor with PNP/ NPN output where applicable. Capsule - The BP99 /3 capsule used in the air vent assembly is suitable for 150 C superheat @ 0 bar g and 50 C superheat @ 3 bar g. Optional extras The top of the cover can be drilled and tapped The bottom of the cover can be drilled and tapped " BSP or NPT for the purpose of fitting a balance line if requested at the point of order. " BSP or NPT for the purpose of fitting a drain cock if requested at the point of order. Standards - This product fully complies with the requirements of the European Pressure Equipment Directive 97/3 /EC and carries the mark when so required. Certification - This product is available with certification to EN 100 3.1. Note: All certification /inspection requirements must be stated at the time of order placement. Sizes and pipe connections DN15, DN0, DN5, DN0 and DN50. Standard flanges are EN 109 PN0 (formerly DIN 501) with face-to-face dimensions in accordance with EN 655 (series 1). Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 009

Page of 5 3 1 10 5 6 5 DN15 IFT57H DN0 1 8 9 7 3 11 5 Materials No. Part Material 1 Body SG iron EN-GJS-00-18U-LT Cover SG iron EN-GJS-00-18U-LT 3 Cover gasket Reinforced exfoliated graphite Cover bolts FT57H Steel CrMo 5 (1.758) Cover studs FT57V Steel CrMo 5 (1.758) Cover nuts FT57V Steel CK 35 (1.1181) 5 Valve seat (DN15-5) Stainless steel X CrNi17(1.057) 6 Valve (DN15-5) Stainless steel X 105CrMo17(1.15) 7 Valve seat (DN0-50) Stainless steel X CrNi 17(1.057) 8 Valve (DN0-50) Stainless steel X CrNi 17(1.057) 9 Main valve gasket Exfoliated graphite 10 Ball float Stainless steel X 5 CrNi 18 10 (1.301) 11 Ball float Stainless steel X 5 CrNi 18 10 (1.301) Sensor gasket Stainless steel BS 19 30 S16 5 Sensor Stainless steel BS 19 30 S16 Note: All other internals are manufactured in stainless steel.

Page 3 of 5 Pressure/ temperature limits Temperature C Steam saturation curve Pressure bar g The product must not be used in this region. The product should not be used in this region due to the limitations of the sensor. Capsule - The BP99 /3 capsule used in the air vent assembly is suitable for 150 C superheat @ 0 bar g and 50 C superheat @ 3 bar g. Body design conditions PMA Maximum allowable pressure 0 bar g @ 10 C TMA Maximum allowable temperature 350 C @ 8 bar g Minimum allowable temperature PMO Maximum operating pressure for saturated steam service TMO Maximum operating temperature PN0-10 C 3 bar g 0 C @ 3 bar g Minimum operating temperature 0 C Note: For lower operating temperatures consult Spirax Sarco. IFT57H- IFT57H-8 IFT57H-1 IFT57H-16 IFT57H-0 IFT57H-3 Maximum Size Model - -8-1 -16-0 -3 PMX differential DN15, DN0 and DN5 bar 8 bar 1 bar - 0 bar 3 bar pressures DN0 and DN50 - - - 16 bar - 3 bar Designed for a maximum cold hydraulic test pressure of: Note: With internals fitted, test pressure must not exceed PMX 60 bar g Dimensions/weights (approximate) in mm and kg IFT57H Size A B C D E Weight DN15 150 8 16 151 119 7.5 DN0 150 53 16 151 119 8.0 DN5 160 58 16 151 119 8.5 DN0 30 75.5 19 08 168 7.0 DN50 30 83 19 08 168 8.0 Size A B D E F G Weight DN15 150 8 1 119 96 175 7.5 DN0 150 53 1 119 106 175 8.0 DN5 160 58 1 119 116 175 8.5 DN0 30 75.5 31 168 151 55 9.0 DN50 30 83 31 168 166 55 30.0 IFT57H DN15 to DN50 DN15 to DN50 D A B D F B C A G E Withdrawal distance E Withdrawal distance

Page of 5 Capacities (in accordance with ISO 78) DN15, DN0 and DN5 DN0 and DN50 Condensate kg/h Condensate kg/h Differential pressure bar (x 100 = kpa) Differential pressure bar (x 100 = kpa) Additional cold water capacities from thermostatic air vent under start-up conditions Under star the main valve. The Table below gives the minimum additional cold water capacities from the air vent. Minimum additional cold water capacities from the air vent (kg/h) P (bar) 0.5 1 3.5 8 10 1 16 0 8 3 DN15, DN0 and DN5 60 680 900 1080 1 50-1 700-000 50 550-3 000 DN0 and DN50 60 680 900 1080-1 300 1 700 1 900-50 550 900 - Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P603-03) supplied with the product. Installation note: The trap is designed for installation with the float arm in a horizontal plane so that it rises and falls vertically, ideally with a drop leg immediately preceding the trap. Suitable isolation valves must be installed to allow for safe maintenance / replacement. Where steam traps are fitted in exposed conditions, the possibility of freezing damage may be reduced by thermal insulation / draining / isolation. For DN15 DN5 sizes It is recommended that a strainer, with a screen having 0.8 mm perforations, is installed upstream of the unit to ensure adequate removal of dirt from the steam system. For DN0 DN50 sizes It is recommended that a strainer, with a 0 mesh screen, is installed upstream of the unit to ensure adequate removal of dirt from the steam system. Maintenance note: Maintenance can be completed with the trap in the pipeline, once the safety procedures have been observed. It is recommended that new gaskets and spares are used whenever maintenance is undertaken. Caution: The cover gasket and main valve assembly gasket may contain a thin stainless steel support ring which may cause physical injury if it is not handled and disposed of carefully. Disposal No ecological hazard is anticipated with the disposal of this product provided due care is taken. How to order Example: 1 off Spirax Sarco DN0 IFT57H-16 ball float steam trap with SG iron body and cover having an integral sensor (SSI) to identify steam leakage. Flanged connections to EN 109 PN0. Trap to be fitted with the optional balance and drain connections.

Page 5 of 5 Spare parts The spare parts available are shown in solid outline. Parts shown in a broken line are not supplied as spares. Available spares Main valve assembly with float (DN15, DN0 and DN5) 5, 6, 10, 1, 13, 1, 15 Main valve assembly with erosion deflector (DN0 and DN50) 7, 8, 9, 16 Ball float (DN0 and DN50 only) 11 Air vent assembly 17, 18 Complete set of gaskets (packet of 3) 3, 9, 18, 0 Sensor and gasket, 5 How to order spares Always order spare parts by using the description given in the column headed 'Available spares' and state the size, Model No., orientation i.e. horizontal (H) or vertical (V) and pressure rating of the trap. Example: 1 - Main valve assembly for a DN0 IFT5H-16 ball float steam trap. For operating pressures up to 16 bar. IFT57H shown 3 Air vent assembly 17 18 (Not an available spare) 11 7 16 8 9 Main valve assembly for DN0 and DN50 size traps with erosion deflector 15 5 1 5 Integral Spiratec sensor Recommended tightening torques Item No. and part Main valve assembly with float for DN15, DN0 and DN5 size traps IFT57H Bolt 10 A/F (socket) M1 x 35 70-75 DN15, DN0 and DN5 Stud M1 35-0 Nut 19 A/F M1 70-75 IFT57H Bolt A/F M16 x 55 150-165 DN0 and DN50 Stud M16 70-80 Nut A/F M16 150-165 5 DN15, DN0 and DN5 Valve seat 17 A/F M1 50-55 7 DN15, DN0 and DN5 Pivot frame assembly screws 10 A/F M6 x 10 10-1 15 DN0 and DN50 Servo-mechanism screws 10 A/ F M6 x 10 10-1 17 Air vent assembly 17 A/F 50-55 Sensor A/F 50-55 or 10 mm 13 6 1 N m