Closed Circuit Cooling Towers

Similar documents
Evaporative Condensers

Evaporative Cooling Products

Layout. Guidelines11. Chapter 11: Layout Introduction

Closed Circuit Cooling Towers

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

Low Profile Layout Guidelines

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

CTI Sponsored Educational Program

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

Closing the Loop What s best for your system?

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

EqUIPMENT LAYOUT MANUAL

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Closed Circuit Hybrid Cooling Towers. Product Introduction...E61. Benefits...E63. Construction Details...E65. Custom Features & Options...

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

PAPER NO: ANDREW RUSHWORTH

How about Savings in Time, Money, Energy and Longer Life?

Evaporative Condensers

Series V Layout Guidelines

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Lenntech. Tel Fax

Product Introduction...E11. Benefits...E13. Construction Details...E15. Custom Features & Options...E19. Accessories...E23. Structural Support...

Un-Used Series CXV Evaporative Condenser

Fan Guard. Fan Guard ASSEMBLY INSTRUCTIONS FOR INDUCED DRAFT PRODUCTS

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Method to test HVAC equipment at part load conditions

Chiller Plant Design. Application Guide AG McQuay International. Elevation Difference. Column Height When Pump Is Off

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Efficient, Long Lasting Evaporative Condensers

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

CONTENTS. B. System Design and Performance Requirements

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

MECHANICAL SERVICES 101. Ian White

MACH N-407 Heat Pump Air-Cooled Chiller

SNOWCOOL SYSTEMS INDIA PVT LTD.

Products and Services

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Cold Weather Operation Of Cooling Towers

Chilled Water system

Technical Development Program

Open Cooling Tower. Equipment Layout Guide

Product Introduction...D33. Benefits...D35. Construction Details...D37. Custom Features & Options...D39. Accessories...D41. Engineering Data...

PACKAGED AIR COOLED Product Data Catalog

New PHE applications in construction & HVAC.

Series 1500 Cooling Tower Specification

How Much Energy is Really Being Wasted?

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

RCF Closed Circuit Cooling Towers RCC Evaporative Condensers

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

JCseries EVAPORATIVE CONDENSER. engineering data

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

CXVB Evaporative Condenser TABLE OF CONTENTS E112 ENGINEERING DATA CXVB EVAPORATIVE CONDENSERS E144 STRUCTURAL SUPPORT CONSTRUCTION DETAILS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

Compressors, Chillers & Condensers

Compass Series Open Cooling Towers

2009 IECC Commercial Mechanical Requirements

Appendix 13. Categories of Cooling and Heating systems

Installation, Operation, and Maintenance Information

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

C13-Series Engineering Guide

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Application Guidelines

MU053: CHILLERS: Operation & Maintenance of Chilled Water Systems

Advance Release September 2009

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Performance Optimization of the Evaporative Condenser Design

Our energy efficient experts and engineers have made ground breaking innovations in this field.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Air Conditioning Inspections for Buildings Condensers

GP SERIES Packaged Chillers

What is Cooling S.Sen

THERMAL ICE STORAGE: Application & Design Guide

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

30GN FLOTRONIC II AIR-COOLED CHILLERS

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Increase your flexibility.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

MAC N-407 Air-Cooled Chiller

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

ICE CHILLER Thermal Storage Products... F2. Benefits... F4. Proven Technology... F7. Construction Details TSU-M - Internal Melt Application...

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

T F E

Transcription:

Closed Circuit Cooling Towers Overview Closed circuit cooling towers provide evaporative cooling for many types of systems, and the specific application will largely determine which BAC Closed Circuit Cooling Tower is best suited for a project The table on page E5 & E6 is intended as a general guide Specialized assistance is available through your local BAC Representative See page E7 for an article on the advantages of closed circuit cooling towers Principle of Operation Closed circuit cooling towers operate in a manner similar to open cooling towers, except that the heat load to be rejected is transferred from the process fluid (the fluid being cooled) to the ambient air through a heat exchange coil The coil serves to isolate the process fluid from the outside air, keeping it clean and contaminate free in a closed loop This creates two separate fluid circuits: (1) an external circuit, in which spray water circulates over the coil and mixes with the outside air, and (2) an internal circuit, in which the process fluid circulates inside the coil During operation, heat is transferred from the internal circuit, through the coil to the spray water, and then to the atmosphere as a portion of the water evaporates Configuration BAC manufactures two types of closed circuit cooling towers: combined flow and counterflow Combined Flow Combined flow is the use of both a heat exchange coil and fill for heat transfer in a closed circuit cooling tower The addition of fill to the traditional closed circuit cooling tower design reduces evaporation in the coil section, reducing the potential for scaling and fouling BAC s combined flow closed circuit cooling towers utilize parallel flow of air and spray water over the coil, and crossflow air/water flow through the fill In parallel flow, air and water flow over the coil in the same direction The process fluid travels from the bottom to the top of the coil, increasing efficiency by bringing the coldest spray water and air in contact with the process fluid at its coldest temperature E1 Baltimore Aircoil Company

In the fill of BAC s combined flow closed circuit cooling towers, air and water interact in a crossflow configuration: water flows vertically down the fill as air flows horizontally across it Counterflow Combined Flow: Parallel Flow of Air and Water Over the coil Air across Water down Combined Flow: Crossflow Configuration Over the Fill In a counterflow closed circuit cooling tower design, the flow of the air is in the opposite direction of the spray water In BAC s counterflow closed circuit cooling towers, air travels vertically up through the unit while the spray water travels vertically down over the coil The process fluid flows from top to bottom through the coil and is in thermal counterflow to the air Closed Circuit Cooling Towers Water down Air up Counterflow Configuration because temperature matters E2

Fan System The flow of air through most factory assembled closed circuit cooling towers is provided by one or more mechanically driven fans The fan(s) may be axial or centrifugal, each type having its own distinct advantages Overview Axial fan units require approximately half the fan motor horsepower of comparably sized centrifugal fan units, offering significant lifecycle cost savings Centrifugal fan units are capable of overcoming reasonable amounts of external static pressure ( 05 ) 127mm of H 2 O, making them suitable for both indoor and outdoor installations Centrifugal fans are also inherently quieter than axial fans, although the difference is minimal and can often be overcome through the application of optional low sound fans and/or sound attenuation on axial fan units Centrifugal Fan Axial Fan Induced Draft Fans can be applied in an induced draft or a forced draft configuration The rotating air handling components of induced draft equipment are mounted in the top deck of the unit, minimizing the impact of fan noise on near-by neighbors and providing maximum protection from fan icing if units operate in sub-freezing conditions The use of corrosion resistant materials ensures long life and minimizes maintenance requirements for the air handling components Forced Draft Rotating air handling components are located on the air intake face at the base of forced draft towers, facilitating easy access for routine maintenance and service Additionally, locating these components in the dry entering air stream extends component life by isolating them from the saturated discharge air E3 Baltimore Aircoil Company

Capacity Range On page E5 and E6, product capacities are called out in terms of a flow rate at 95ºF/85ºF/78ºF This refers to the flow rate of water that the unit can cool from a 95ºF (350ºC) entering water temperature to an 85ºF (294ºC) leaving water temperature at a 78ºF (256ºC) entering wet-bulb temperature BAC offers selection software to evaluate the performance of a closed circuit cooling tower at any conditions; see page M17 for details All capacities shown are for a single cell; multiple cell units can be applied to achieve larger capacities Maximum Entering Water Temperature All BAC Closed Circuit Cooling Towers are capable of withstanding entering fluid temperatures as high as 180ºF (822ºC), and the HXV is capable of withstanding even higher temperatures due to the added dry coil technology Closed Circuit Cooling Towers because temperature matters E4

Closed Circuit Cooling Tower Product Lines Overview Single Air Inlet Models FXV Dual Air inlet Models Principle of Operation Configuration Combined Flow Combined Flow Fan System Axial Fan, Induced Draft Axial Fan, Induced Draft Capacity Range (Single Cell) 26-299 Nominal Tons 787-896 GPM at 95 F/85 F/78 F 344-624 Nominal Tons 1,031-1,872 GPM at 95 F/85 F/78 F Maximum Entering Water Temperature Typical Applications Small to medium HVAC & industrial such as water source heat pump loops and air compressor cooling Tight enclosures & installations requiring a single air inlet Unit replacements Medium to large HVAC & industrial such as electric arc furnaces and pharmaceutical plants E5 Baltimore Aircoil Company

VF1 Series V VFL (low profile) WATER DISTRIBUTION SYSTEM IN MODULATING FLOW CONTROL VALVE PRIME SURFACE COIL IN SPRAY PUMP HXV WARM OUT WATER COLD WATER BASIN Counterflow Counterflow Combined Flow Centrifugal Fan, Forced Draft Centrifugal Fan, Forced Draft Axial Fan, Induced Draft 41-543 Nominal Tons 124-1,629 GPM 95 F/85 F/78 F 39-108 Nominal Tons 116-3246 GPM at 95 F/85 F/78 F WARM WARM FILL 160-305 Nominal tons 480-915 GPM at 95 F/85 F/78 F FINNED COIL Closed Circuit Cooling Towers Entering water temperature can exceed 180 F but is application specific; contact your local BAC Representative for details Small to medium HVAC & industrial such as water source heat pump loops and air compressor cooling Indoor installations High temperature Tight enclosures & installations requiring a single air inlet Extremely sound sensitive Small to medium HVAC & industrial Installations with extremely low height requirements Indoor installations High temperature industrial Extremely sound sensitive Small to medium HVAC & industrial such as water source heat pump loops and air compressor cooling Installations requiring plume abatement Installations requiring water conservation Large range/close approach High temperature industrial because temperature matters E6