JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other

Similar documents
VENTING IS ALL AROUND US

Pressure equalization by Venting

Pressure equalization by Venting

CFH Series High Efficiency Filters

gas monitoring system

Protective Vents adhesive series

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Introducing Solar Identification Labels

Kitchen Exhaust Air Cleaning Systems

Dome Fiber Optic Closure SC-221

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

140 FT. LONG HOT AIR OVEN FOR SOLVENT COATINGS

How to comply with CDC Guidelines

Tyco Electronics Solar Identification Labels

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Innovation in air purification unmatched air quality

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING

M5200 Industrial Pressure Transducer

WFH Series. High Efficiency Filters

M7100 Pressure Transducer

SOLID PLUS HEAT

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

GateKeeper Gas Purification System Z2 Series for 400, 500, 600 NM 3 /HR

U5300 Industrial Pressure Transducer

U5600. Wireless Pressure Transducer SPECIFICATIONS

(HR) Heating Resistors

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

GateKeeper Gas Purification System Z2 Series

portable gas analyser

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

BARD Cabinet Finishes and Corrosion Coating Options

ACT Cartridge Dust Collector

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Waveguide Dehydrators

The name to vacuum with...

Electrostatic Precipitator

GateKeeper Gas Purification System SX Series

DP86 Constant Voltage with Fitting

EHH SERIES DRAW THROUGH FAN COILS CFM

SECTION AIR COILS

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS

Outside Air Humidity & Temperature Sensor

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Understanding Hazardous and Explosion-Protection Environments

5CONSIDERATIONS WHEN SELECTING A DESICCANT BREATHER FOR YOUR EQUIPMENT

M5800 Pressure Transducer with Rotatable Display

Well Tanks and Expansion Tanks

2002 METAL FORM MFG. Form No: CCIOM/03

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Adsorption Air Dryers

Technical Catalog laboratory furniture system

Advantages / Characteristics

Filters & Centrifugal Separators

ELSTA MOSDORFER- Energy Distribution with Competence

CI/SfB. September MediCare range. MediCare Standard. MediCare Plus. MediCare Air

Protective & Marine Coatings Europe, Middle East, Africa & India

for relative humidity and temperature with calibration certificates

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

SALT SPRAY & CYCLIC CORROSION CHAMBERS

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Data Sheet. Humidity control products. Data Pack K Issued February

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

SPECTRACOOL Indoor & Outdoor Air Conditioners

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

2003 METAL FORM MFG. FORM NO: PCIOM/03

Operating Instructions

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

TrueTech Energy TT - HYD Series

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Duct Humidity/Temp Sensor

52nd North Carolina Industrial Ventilation Conference

Confined Space Ventilation equipment

Introduction Airflow and filtration area General design practices Cleaning system

Operating instructions

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Chilled Water DOAS Fan Powered Terminal Units

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR

Item # Modular Blast CaBinEt instructions

Service Parts for RMR Wall-Mount Enclosures

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

For commercial & industrial systems. Large volume dirt collection capacity

CONFINED SPACE VENTILATION

Transcription:

Membrane Vent Product Description JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other liquids without negatively affecting their operation. It is comprised of a filtration membrane and a pressure-sensitive adhesive ring for securing the filter to the device. Features and Benefits Typical Applications High efficiency particulate removal Automotive electronics Venting of gases and pressure equalization Telecommunication hardware Eliminates the need for costly hermetic sealing Radios Repels water, oils, and other liquids GPS navigation and other portable devices Easy application and device integration Wide variety of standard sizes and material available

Membrane Vent Dimension (Unit: mm) P/N 22-001-003-0100 22-001-004-0100 22-001-007-0100 22-001-008-0100 22-001-009-0100 Sizes OD*ID mm 21.5*12.5 Inch 0.85*0.53 mm 19.1*8.9 Inch 0.75*0.35 mm 7.6*3.3 Inch 0.32*0.13 mm 11*7 Inch 0.43*0.28 mm 10*5.5 Inch 0.39*0.22

Membrane Vent Specification Media Description Efficiency Air Flow Thickness Water Entry Pressure Pore Size Operating Temperature Oleophobicity (AATCC 118-1992) IP Rating (per IEC 529) Adhesive Type Typical Structure Recommended Substrates Adhesive Layer Thickness (TAPPI 411) Total Thickness (TAPPI 411) Continuous Service Temperature Short-term Temperature Minimum Temperature Oleophobic eptfe membrane with polyester / polyethylene scrim White 99.99% on 0.1 μm @ 3.2 meters / minute air velocity (99.99% on 0.1 μm @ 10.5 fpm air velocity) 8.5 liters / hr / cm²@ 12 mbar (0.5 cfm / sqft @ 0.5 inches water) 0.20 mm @ 35 mbar (8 mils @ 0.5 psi) 0.8 bar (330 inches water or 12 psi) 1.0 μm 110 C (230 F) Rating = 8 (0 to 8: 8 is most repellent) IP67 High temperature acrylic PSA 0.05mm carrier with PSA on each side (2 mil) High energy surfaces (ABS, PC, PET, nylon, metal, etc.) 0.051 mm (2 mil) 0.152 mm (6 mil) 150 C (300 F) 233 C (450 F) -40 C (-40 F)

Push-in Vent Product Description JONES Push-in Vent is design for venting air and preventing water intake. Through it excellent permeability, Push-in Vents balance the air pressure difference between inside of housing and environmental condition and low the pressure on seal gaskets, therefore it prolongs seal gaskets service life and improve the reliability of the device. The micro-pore membrane structure of eptfe build-in Push-in Vent provides an effective barrier from dust and dirt and still allows the product to breathe with changing environmental conditions. This prevents pressure from building up and damaging enclosure seals, exposing sensitive components to water and debris. Equipment used in the telecommunications industry is subjected to rapid temperature fluctuations, a variety of particulates, and exposure to wind, precipitation and solar radiation. JONES Push-in Vent Vents effectively protect them against the negative effects of pressure differentials caused by temperature changes and provide an effective barrier against dust, water, salts and other corrosive liquids. Especially Its threaded design ensures secure mechanical fastening, its durable designs keep it able to used in extremely harsh environments in the field. Its unique property makes it find the wide application in shipboard telecommunication and alarm system.

Push-in Vent Features and Benefits Typical Applications eptfe membrane build-in silicone case without PSA Automotive electronics High reliability Telecommunication hardware Easy to install Radios GPS navigation and other portable devices Dimension (Unit: mm) Specification Construction Material Base : Silicone Membrane: eptfe Property of Membrane IP Rating (per IEC 529) Temperature resistance (DIN IEC 68-2-14 Na) UV Resistance Gray or White Rating of Oil Repellency6(AATCC 118-1989ASTM) Water Entry Pressure : >0.7 bar/60 sec IP67 Under 1 meter water, no leakage /30 minutes IP69K steam jet resistance -40 ~125 Cycling Test:Cycles =400 TDWET=20 min Tchange<10s Industrial Climate Test (DIN 50-0-18) Standard SFW 2.0S 9 Cycles, No mechanical change found Salt Mist Test(DIN 50-0-21) 85/85 Storage Test (DIN IEC 60068-2-3) Typical airflow (dp = 70 mbar/1.0 psi) Hardness range, Shore A,±5 70 No salt particles entering housing through the vents 85,85%r.H. Test Time 1000 hours, No mechanical change found Type A 600 ml/min

M12X1.5 Screw-in Vent Product Description JONES Screw-in Vent is design for venting air and preventing water intake. Through it excellent permeability, Screw-in Vents balance the air pressure difference between inside of housing and environmental condition and low the pressure on seal gaskets, therefore it prolongs seal gaskets service life and improve the reliability of the device. The micro-pore membrane structure of eptfe build-in Screw-in Vent provides an effective barrier from dust and dirt and still allows the product to breathe with changing environmental conditions. This prevents pressure from building up and damaging enclosure seals, exposing sensitive components to water and debris. Equipment used in the telecommunications industry is subjected to rapid temperature fluctuations, a variety of particulates, and exposure to wind, precipitation and solar radiation. JONES Screw-in Vent Vents effectively protect them against the negative effects of pressure differentials caused by temperature changes and provide an effective barrier against dust, water, salts and other corrosive liquids. Especially Its threaded design ensures secure mechanical fastening, its durable designs keep it able to used in extremely harsh environments in the field. Its unique property makes it find the wide application in shipboard telecommunication and alarm system. Features and Benefits eptfe membrane build-in plastic case without PSA High reliability Easy to install Typical Applications Automotive electronics Telecommunication hardware Radios GPS navigation and other portable devices TEL: +86 10 6786 2636 FAX: +86 10 67860291

M12X1.5 Screw-in Vent Dimension (Unit:mm) Specification Construction Material Base : PA-6 Membrane: eptfe O Ring Seal : Silicone Property of Membrane Gray or White Rating of Oil Repellency6(AATCC 118-1989ASTM) Water Entry Pressure : >0.7 bar/60 sec IP Rating (per IEC 529) IP67 Under 1 meter water, no leakage /30 minutes Temperature resistance (DIN IEC 68-2-14 Na) IP69K steam jet resistance -40 ~125 Cycling Test:Cycles=400 TDWET=20 min Tchange<10s UV Resistance Salt Mist Test(DIN 50-0-21) Industrial Climate Test (DIN 50-0-18) Standard SFW 2.0S mechanical change found No salt particles entering housing through the vents 9 Cycles, No 85/85 Storage Test (DIN IEC 60068-2-3) Typical airflow (dp = 70 mbar/1.0 psi) 85,85%r.H. Test Time 1000 hours, No mechanical change found Type A 600~1200 ml/min Type B 1500 ml/min Continuous Service Temperature 150 C TEL: +86 10 6786 2636 FAX: +86 10 67860291

M12X1.5 Screw-in Vent (300 F) Short-term Temperature Minimum Temperature 233 C (450 F) -40 C (-40 F) P/N Property 22-101-002-0000 22-102-002-0000 22-101-002-0001 22-102-002-0001 Typical airflow Typical airflow Typical airflow Typical airflow Gray 600~1200 ml/min White 1500 ml/min Gray 600~1200 ml/min White 1500 ml/min Contact Information ADD: 3 DongHuanZhong Road, Beijing Economical & Technological Development Area Beijing 100176 China TEL: +86 10 67862636 FAX: +86 10 67860291 TEL: +86 10 6786 2636 FAX: +86 10 67860291

M4X0.7 Shield Screw-in Vent Product Description JONES Screw-in Vent is design for venting air and preventing water intake. Through it excellent permeability, Screw-in Vents balance the air pressure difference between inside of housing and environmental condition and low the pressure on seal gaskets, therefore it prolongs seal gaskets service life and improve the reliability of the device. The micro-pore membrane structure of eptfe build-in Screw-in Vent provides an effective barrier from dust and dirt and still allows the product to breathe with changing environmental conditions. This prevents pressure from building up and damaging enclosure seals, exposing sensitive components to water and debris. Metal Screw-in Vent has excellent shielding effect than PA-6 vent. High strength metal case has good heat resistance and high impact properties, also has a good weatherability. Equipment used in the telecommunications industry is subjected to rapid temperature fluctuations, a variety of particulates, and exposure to wind, precipitation and solar radiation. JONES Screw-in Vent Vents effectively protect them against the negative effects of pressure differentials caused by temperature changes and provide an effective barrier against dust, water, salts and other corrosive liquids. Especially Its threaded design ensures secure mechanical fastening, its durable designs keep it able to used in extremely harsh environments in the field. Its unique property makes it find the wide application in shipboard telecommunication and alarm system.

M4X0.7 Shield Screw-in Vent Features and Benefits Typical Applications Excellent shielding effect Automotive electronics eptfe membrane build-in metal case without PSA Telecommunication hardware High reliability Radios Easy to install GPS navigation and other portable devices Dimension (Unit: mm) Size(mm) P/N M L H D 22-301-010-0000 M4*0.7 6.8 5 9.8 Specification Construction Material Property of Membrane IP Rating (per IEC 529) Base : Copper nickel plating Membrane: eptfe Silver Rating of Oil Repellency6(AATCC 118-1989ASTM) Water Entry Pressure : >0.6 bar/60 sec IP67 Under 1 meter water, no leakage /30 minutes IP69K steam jet resistance Temperature resistance (DIN IEC 68-2-14 Na) -40 ~125 Cycling Test:Cycles =400 TDWET=20 min Tchange<10s UV Resistance Salt Mist Test(DIN 50-0-21) 85/85 Storage Test (DIN IEC 60068-2-3) Typical airflow (dp = 70 mbar/1.0 psi) Industrial Climate Test (DIN 50-0-18) Standard SFW 2.0S 9 Cycles, No mechanical change found No salt particles entering housing through the vents 85,85%r.H. Test Time 1000 hours, No mechanical change found 75 ml/min