FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

Similar documents
FLIM/FFS Upgrade Kits for Zeiss LSM systems

Microscopy from Carl Zeiss

Compact FLIM and FCS Upgrade Kit for Laser Scanning Microscopes (LSMs)

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

An FT-NIR Primer. NR800-A-006

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Industrial presentation. Philippe Marchais - July 3rd, NDIP Tours

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Bunch Length Interferometer System

HTRF. SpectraMax Paradigm Cisbio HTRF Detection Cartridge. User Guide

RAMAN SPECTROSCOPY See more, faster than ever before

palmotdr Series Handheld OTDR

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

WHAT IS LASER ULTRASONIC TESTING?

Variable Temperature Microprobe Systems

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Laser Diagnostics and Optical Measurement Techniques

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

M210 Multifunction Micro OTDR

AV6416 OTDR. Product Overview: Main Features:

Development of On-line Instrumentation and Techniques to Detect and Measure Particulates

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Specifications Wavelength Range: 190 nm to 800 nm continuous

EasyLog Data Logger Series

M210 Multifunction Micro OTDR

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

4-Channel-aSTEM Detector. Detecting Transmitted Electrons in an FESEM with the new Annular STEM Detector. Upgrade Info

EasyLog Data Logger Series

HESAI. HS-4000 Laser-Based Remote Methane Leak Detector

Customized MCPs for Analytical Instruments. An MCP for every application

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

SPECTRAL INSTRUMENTATION

LHCb Rich Detectors Control and High Voltage Systems

Technical specifications of FT-IR Spectrometer

palmotdr Series Handheld OTDR

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Remote fiber testing to improve SLA s

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017


The Optical Scattering Calibration System at SNO+ IOP 2015

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Recommended Work Area Controls

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Spectrum Detector, Inc.

SOLUTION MINING RESEARCH INSTITUTE

Standard Operating Procedure Raman Microscope - Renishaw invia

BGA Rework Station Pro-660

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

The FEL Facility Optical Diagnostics and FEL Characterization

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

Surface Concept Product Catalog 2014

PC474 Lab Manual 1. Terry Sturtevanta and Hasan Shodiev 2. Winter 2012

MINI2 MOST ACCURATE COMPACT OTDR

Thank You for Attending Today s Webinar:

Current Research Topics in Optical Sensors and Laser Diagnostics

APPLIED. OMA-406R Rackmount Process Analyzer

VM-3000 Mercury Vapor Monitor

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

VM-3000 Mercury Vapor Monitor

FX150 OTDR. Platform Highlights. Key Features

NanoReady. Micro UV-Vis Spectrophotometer

VIEW500 USER-FRIENDLY STANDARD OTDR

Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Modular LIBS System. User s Manual. September 2010 Doc. Ref.: UM/ /01

Noyes OFL 250B Specs Provided by

Variable Temperature Options for Optical Experiments

Temperature Data Logging

Laser Distance Sensor Type M Analog-Output

LASER SAFETY BARRIER

FI-DL. SpectraMax Paradigm Fluorescence Intensity Dual Label (FI-DL) (MultiTox-Fluor) Detection Cartridge. User Guide

OMA-300 Process Analyzer

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

WL 110 Series. Heat Exchanger with Supply Unit EQUIPMENT FOR ENGINEERING EDUCATION

WG Container & Cargo X-Ray Scanning Portal

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

VIEW500 FASTEST STANDARD OTDR

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Mercury Vapor Monitor VM-3000

Transcription:

TECHNICAL NOTE FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes Shih-Chu Liao, Yuansheng Sun, Ulas Coskun ISS, Inc. 1 Introduction The FLIM and FFS Upgrade Package for the Olympus confocal microscopes (FV1000, FV1200, FV3000, and FVMPE-RS) incorporates the acquisition of Fluorescence Lifetime Imaging (FLIM) while introducing an additional measurement capability for the Fluorescence Fluctuations Spectroscopy (FFS) family. The Upgrade Package does not reduce any of the microscope original operations to the standard measurements; in contrast, it provides the following additional measurements: Fluorescence Lifetime imaging Measurements can be carried out in a combination of X,Y, Z, and t dimensions Digital frequency-domain (DFD) FLIM Acquired by FastFLIM. Time-domain FLIM Acquired in time-correlated single photon counting (TCS) Fluorescence fluctuation spectroscopy utilities Data can be acquired in the counts, the time tagged or the time tagged time resolved (TTTR) mode Autocorrelation (FCS) The FCS function gives the temporal correlation of the fluctuations Cross-correlation (FCCS) The FCCS function provides the temporal correlation of the fluctuations related to events occurring simultaneously on two or three channels. Photon Counting Histogram (H) The H function plots the distribution of photon counts at the specified time interval FFS measurement at target XYZ locations in an image The user selects the XYZ location by moving the cursor or entering the values in the software. FLCS, fluorescence lifetime correlation spectroscopy The FCS data points are acquired in the Time-Tagged- Time-Resolved mode, allowing both FCS and FLIM analysis. 1 ISS TECHNICAL NOTE

Number & Brightness (N&B) A series of raster images acquired in fast way and in photon counting mode. It separates the mobile from the immobile fluorophores; it separates monomers form dimers. Anisotropy Anisotropy measurements provide information about orientation and rotation information thru polarization measurements Nanoimaging and Orbital Particle Tracking Particle tracking Tracks isolated particle Tracks particle with nanometer resolution Analyze the dynamics of the system like motion characteristics (ballistic, diffusion, trapped, etc), lifetime, brightness along the path Edge Tracking Studies dynamics on interface surfaces like cell membrane Nanoimaging Provides image for a micrometer size extrusions with nanometer diameter like microtubules Figure 1.1 Model FV1200 confocal microscope The upgrade package requires an attentive selection of four key elements: The wavelengths required for single-photon excitation The way to carry out the upgrade (use of internal detectors, or addition of external detectors) 2 ISS TECHNICAL NOTE

The type of light detectors to be utilized for the acquisition (GaAs, hybrid detectors) The FLIM/FFS data acquisition modality (FastFLIM or TCS) 2 Different ways to carry out the upgrade The upgrade of the Olympus systems can be achieved in three different ways: Using the internal light detectors of the FV1000 LSM system; or the detectors provided by Olympus in the FV1200; or the detectors mounted on the descanned or non-descanned NDD port. Collecting the fluorescence signal from the fiber port of the confocal head and diverting it to the 2- detector unit (made by ISS). The unit, controlled though the USB port, features an automated filterwheel holding the dichroics, automated filterwheels in front of each detector, and automated shutters. Adding two detectors (mini TDU, made by ISS) to the fiber port of the microscope; additional detectors can be cascaded for more acquisition channels. This option offers the maximum sensitivity. The upgrade works for both single-photon laser excitation and multiphoton laser excitation. When the single-photon excitation option is used, the port for multiphoton excitation is left untouched (that is, a multiphoton laser can still be connected to it), a feature not available with other commercial upgrade options. The upgrade package does not modify in any ways the operations of the instrument as originally installed by Olympus. The single-photon light beam will be injected into the scanner head utilizing the VIS port and a laser combiner unit that merges the beam from the Olympus laser launcher with the beam from the ISS laser launcher. Comparison Table Features Disadvantages Using internal detectors Economical upgrade package Sensitivity and response time for FLIM is limited by the detectors Using the fiber port The 2-detector unit features automated filter wheels in front of each detector. 15% loss of signal Using the 2-detector unit connected to the output port of the microscope Highest sensitivity Anisotropy measurement capability can be added. Filters and dichroic have to be inserted and replaced manually by the operator 3 ISS TECHNICAL NOTE

2.1 Using the internal detectors of the Olympus LSM microscope Figure 1 below is a schematic of the upgrade using the internal detectors of the Olympus FV1000 system. With this upgrade the ISS technical personnel accesses the internal detectors and adds a routing system that diverts the signal to the data acquisition card. For the FV1200, Olympus may provide two external detectors (GaAs); the signal can be collected at the detectors directly. FLIM upgrade FV1000 microscope FLIM acquisition card REF USB cable pulsed lasers CLK cable detectors routing unit control electronics FV1000 confocal head lasers (405 nm, 440nm, 488nm, 559 nm, 635 nm) Figure 2.2.1 Schematics of the FLIM Upgrade using the internal PMTs of the Olympus FV1000. The parts to the right include the instrument components (, control electronics, scanner and laser launcher). The left part of the schematics includes the components provided by ISS with the upgrade package. In this schematics the lasers for FLIM are delivered through a fiber that joins the fiber from the Olympus lasers using the laser combiner. Figure 2.2 Confocal head of the FV1000 with the ISS panel for the Output signals of the internal detectors. 4 ISS TECHNICAL NOTE

2.2 Collecting the fluorescence signal from the fiber port and diverting to the 2-detector unit by ISS The Figure below shows the upgrade package where the florescence light is collected by the fiber port of the confocal head. FLIM upgrade FV1000 microscope FLIM acquisition card REF USB cable pulsed lasers CLK cable 2-Detectors Unit control electronics FV1000 confocal head lasers (405 nm, 440nm, 488nm, 559 nm, 635 nm) Figure 2.3 FLIM Upgrade using the fiber port on the confocal head of the Olympus FV1000. The parts to the right include the instrument components (, control electronics, scanner and laser launcher). The left part of the schematics includes the components provided by ISS with the upgrade package. In this schematics the lasers for FLIM are delivered through a fiber that joins the fiber from the Olympus lasers using the laser combiner. 2.3 Adding two detectors (mini TDU) to the output port of the microscope A schematics of the two-detectors added to the confocal head of the Olympus is shown below. The twodetectors feature a dichroic filter and separate filters inserted manually by the user. FLIM upgrade FV1000 microscope FLIM acquisition card REF USB cable pulsed lasers CLK cable 2-detectors control electronics FV1000 confocal head lasers (405 nm, 440nm, 488nm, 559 nm, 635 nm) Figure 2.4 FLIM Upgrade where the two detectors are connected to the confocal head of the Olympus FV1000. The parts to the right include the instrument components (, control electronics, scanner and laser launcher). The left part of the schematics includes the components provided by ISS with the upgrade package. In this schematics the lasers for FLIM are delivered through a fiber that joins the fiber from the Olympus lasers using the laser combiner. 5 ISS TECHNICAL NOTE

Figure 2.5 The two GaAs detectors (upper deck with yellow housing) and ISS beam combiner (lower deck with white ISS sticker) are coupled directly on the confocal head of the FV1000. 3 FLIM in frequency-domain (FastFLIM) or in time-domain (TCS) FLIM acquisition is available from ISS in either modality: frequency domain (FastFLIM); or, time-domain (time correlated single photon counting, TCS) The choice is left to the customer and, in fact, if required, both acquisition modalities can be implemented on the same instrument. FastFLIM is more immune the pile-up effect compare to the TCS as the dead time is much less and the duty cycle is higher; FastFLIM is suggested when measuring FRET in live cells or with bright isolated species. Number of input channels 4 parallel channels FastFLIM 1 channel TCS Additional cards can be used in parallel; or a router can be utilized for 4 channel Dead time 3.125 ns 125 ns Max signal count 13,000,000 counts/sec 1,000,000 counts/sec Min time bin 20 ps 813 fs Architecture USB2 I bus Table I. Comparison of FastFLIM and TCS acquisition 6 ISS TECHNICAL NOTE

4 The detectors The detectors utilized by ISS, made by Hamamatsu, are H7422P (GaAs) R10467 (hybrid) Figure 4.1 Dual-in line H7422P PMT; the unit includes a dichroic for the separation of the incoming beam and filters in front of each detector. The sensitivity region of the detectors has to match the wavelength acquisition range of the measurements; contact ISS for recommendations and selection. 7 ISS TECHNICAL NOTE

5 The laser launcher In multiphoton system, ISS uses the laser originally installed with the instrument. For single photon excitation, ISS provides lasers for the FLIM/FFS upgrade. The wavelengths available are: Laser diodes 375, 405, 440, 473, 488, 514, 530, 635 nm DSSP laser 561, 588, 598 nm ISS laser launchers can accommodate 3-, 4- and 6-lasers. The laser launcher can accommodate lasers made by ISS, B&H, and Coherent. The laser launcher is controlled through the USB port of the computer by the ISS VistaVision software. Each laser beam can be ON/OFF; also the intensity can be controlled independently. The lasers beams are superimposed in the unit and delivered to the laser combiner by using a single-mode fiber. Figure 5.1 Three-laser launcher. The unit can mount different lasers; the beams are superimposed inside the unit and the light is delivered to the confocal head by the fiber optic cable. Figure 5.2 Four-laser launcher. The lasers are mounted inside the unit. The lasers are housed in the laser launcher where the lasers beams are superimposed and focused into a single-mode fiber; the fiber delivers the beam into the laser combiner connected to the VIS port (the multiphoton port is not used). Lasers made by ISS, B&H and Coherent can be accommodated in the unit. The laser combiner superimposes the beams coming from the ISS laser launcher and from the Olympus laser launcher with a polarizer to minimize the coupling loss. The ISS beam combiner can accept OZ optics, QI-Optics, and Olympus fiber couplers. 8 ISS TECHNICAL NOTE

Figure 5.1 Laser combiner. The adapter from the Olympus laser launcher is connected to the left (point A); the adapter from the ISS laser launcher is connected to the top. The brass thumbscrew (C) allows for selection either laser launcher. 6 Summary The FLIM/FFS upgrade of your Olympus Laser Scanning Microscope can be done in several ways. Contact ISS for discussing your intended application; ISS technical personnel is available for answering your questions and discuss the best way to achieve your goals. For more information please call (217) 359-8681 or visit our website at www.iss.com 1602 Newton Drive Champaign, Illinois 61822 USA Telephone: (217) 359-8681 Fax: (217) 359-7879 Email: iss@iss.com Copyright 2016 ISS Inc. All rights reserved, including those to reproduce this article or parts thereof in any form without written permission from ISS. ISS, the ISS logo are registered trademarks of ISS Inc. 9 ISS TECHNICAL NOTE