EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Similar documents
EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

COOLS AND FILTERS THE AIR ENVIRONMENT FRESCO OK TECHNOLOGY AND INNOVATION EVAPORATIVE COOLER HEATING COOLING GREEN ENERGY

when the equipment is combined with Systema control panels. 3 working programs: enabled)

RANGE OF PRODUCTS AND SOLUTIONS FOR HEATING AND COOLING

INFRA BAF DES FARMS AND GREENHOUSES RADIANT SYSTEM WITH 3 SPECIFIC FEATURES HEATING COOLING GREEN ENERGY RADIANT HEATING HEATING OF THE FLOOR

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Rapid. Suspended Warm Air Heater. Caring for the environment!

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

GAS AIR HEATER RANGE

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Condensing, pre-mixed, wall-hung gas boilers with water tank

1 VICTRIX ZEUS Superior kw I features

Power X High Power Condensing Wall-Hung Boilers

Wall-mounted air heaters for outdoor installation MEC EX C

SPECIFICATIONS - NIKE

Blower-YEFB-020-3R-1maxVel

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

C Tahiti. condensing

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

white blue cobalt bordeaux light oak (rovere)

Ciao Green Condensing Wall-Hung Boilers

... UDSA - UDSBD Gas fired unit heaters...

Gas heaters and convectors ROBUR

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Gas-fired unit heaters for indoor installation

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

IMPORTANT Read this manual carefully before starting up the system. In order to improve the product, Systema reserves the right to modify the content

SILVERTOP RANGE ENERGY RECOVERY

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Power X High Power Condensing Wall-Hung Boilers

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

ENERGY TOP. Condensing boiler solutions

OVENS LINE. Pocket 4060 rack oven for bread and pastry

Tower Green HE Hybrid

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

SGE Condensing Gas - Solar Water Heater

Ideasandformsinevolution

GAS UNIT HEATERS ARM RANGE

COND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

BORA BORA. BORA gas: the best suns THE MODELS BORA GAS ALL INNOVATION STRENGTHS

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

PCH/new Series. High performance, total flexibility

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Capri B Cast iron combination oil-fired boiler with water tank

VPC Gas Cabinet Heater Range

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PK-N Floor Standing Heater

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

FORMENTERA KC - KRB - KR

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

KOMFORT EC DB Suspended heat recovery air handling units

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Wall hung combination

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Exclusive Green E Condensing Wall-Hung Boilers

BFC Cyclone Condensing Glass-Lined Water Heater

INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV HFM

Capri R CH only, oil-fired, cast iron boiler

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

THE PERFECT CONDENSATION

Indirect gas-fired air heater

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Products and prices. CLIMATE TECHNOLOGY feels better, works better.

The iqe Boiler Range. Combination and System T Boilers.

EHR EHR HIGH PERFORMANCE IN MINIMAL SPACE THE FUME-WATER RECUPERATOR FOR HEATING & AIR-CONDITIONING. imita la natura

A/23 MFFI - A/27 MFFI

Flue gas condensation...

Since 1983 Nuova COTERM has developed a wide range of water heaters.

Seradens Super Seradens Super Plus

Mynute Green Condensing Wall-Hung Boilers

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Transcription:

EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION MORE CENTRIFUGAL FAN CONFIGURATIONS HEATING COOLING GREEN ENERGY

EOLO B RT: NEW The new condensing and modulating ROOF-TOP gas air heater EOLO B RT is the gas for roof-top installations, produced by Systema S.p.A.. This product is suitable for indoor and outdoor applications and can be fit with ventilation duct for air distribution. The efficiency of this equipment is really high and reaches 108%, the structure is solid and its components guarantee quality, great design and a long-lasting resistance. ADVANTAGES CE certificate 10CO000 Technical features - Centrifugal fans and air intake where it is possible to install the filter and the flange for the connection of the air intake duct þ HIGH EFFICIENCY up to 108% þ NOISELESS þ 10 YEARS GUARANTEE * þ The airtight BURNER is INSTALLED INSIDE the UNIT þ INDOOR or OUTDOOR version þ EASY to be installed þ Available in versions: - EOLO B RT BC = modulating and condensing - EOLO B RT BL = On/Off or modulating - Epoxy painted galvanized steel structure with insulation - Reflecting and solid self-supporting structure - Easy access to electrical cabling and burner casing - High efficiency heat exchanger, flue back project with condensing discharge - Outdoor installation with temperature up to -0 C using the specific low temperature kit (optional) * The guarantee depends on regular maintenance MODULATING PREMIX BURNER DESIGNED BY SYSTEMA

TWO VERSIONS OF ROOF-TOP HOT AIR HEATER Power from to 1 kw - Classe Nox EOLO B RT BC (Eolo Vip B RT) - Modulating and condensing version with stainless steel exchanger and premix burner designed and realized by Systema S.p.A. - Automatic modulation of the thermal power from 100% to 0%. - Combustion efficiency minimum power 108% - Combustion efficiency maximum power 98% EOLO B RT BL (Eolo B RT Bluline) - High efficiency ON/OFF or modulating version, with premix burner designed by Systema S.p.A. - Automatic modulation of the thermal power from 100% to 0%. - Combustion efficiency minimum power 9% - Combustion efficiency maximum power 9% MORE CENTRIFUGAL FAN CONFIGURATIONS 00 Pa Standard centrifugal fans 00 Pa Optional centrifugal fans with higher performance up to 00 Pa 00 Pa Optional centrifugal fans with high performances up to 00 Pa 1000 Pa Optional centrifugal fans with very high performances up to 1000 Pa Performance according ERP 01 DIMENSIONS OF STANDARD VERSIONS Standard version Double air intake (view of air intake side) Double air intake (view of delivery side) A H B1 A A X A A1 Y B MODEL X Y H A1 A A A B1 B EOLO B RT EOLO B RT 100 100 90 00 0 00 00 00 00 EOLO B RT EOLO B RT EOLO B RT EOLO B 8 RT 100 10 1010 00 00 00 900 00 900 EOLO B 100 RT EOLO B 10 RT EOLO B 10 RT 1900 000 100 00 110 100 900 00 800 800 1000 1000 800 1000 1000 EOLO B 00 RT 0 00 100 1000 900 1000 100 1000 100 EOLO B 0 RT 00 00 100 1000 100 100 EOLO B 00 RT 0 00 000 10 900 10 1100 10 1100 EOLO B 00 RT 000 00 00 Please, get in touch with the Technical Dep. WARNING The dimensions of the ducts indicated in the sheet are referred to standard version. For special application they can be modified to satisfy the installation needs. For the sizing of insulated ducting, please get in touch with the Technical Department.

Accessories 1 1 1 1 1 1 1 Air intake/delivery panel Air intake vent Two-ways air dumper Two-ways flanged air intake panel Air intake vent for two-ways panel Insulation cover for right delivery Insulation cover for left delivery 8 Insulation cover for roof delivery 9 Left/right delivery bend 10 Roof delivery bend 11 Side mixing section 1 Roof mixing section 1 Belimo proportional device for air dumper with 0-10V control 1 G/G air filter 9 9 8 1 1 10 11 8 1

Technical features Models RT RT RT RT RT 8 RT 100 RT 10 RT 10 RT 00 RT 0 RT 00 RT 00 RT Thermal capacity ver. BC kw 8-10- 1-18- 1- -8-10 0-1 -1-10 8-0 9-1 1-0 Combustion Efficiency BC ** Min % 10.9 10.9 10,1 10,1 10 10, 10,8 10, 108 108 108 108 108 Max % 9, 9, 9 9 9,9 98,1 98 98 98 98 98 98 98 Thermal capacity ver. BL kw 1- - 0- - - 9-8 1-10 88-1 108-1 1-10 18-0 0-1 9-0 Combustion Efficiency BL ** Nominal gas consumption (Hi) (1 C - 101,mbar) Min % 9 9 9 9 9 9 9 9 9 9 9 9 9 Max % 9, 9,9 9 9,8 9,8 9, 9, 9, 90 90 90 90 91 G0 Nat. gas 0 mbar G1 Propane mbar G0 Butane mbar m /h,,9,,, 8,89 10,9 1, 1,,,1,, kg/h 1,1,9,,0,9, 8 9,1 1,0 1, 0,,8, kg/h 1,,1,,08,9,8 8,0 9,8 1,1 1, 0,8,9,91 Gas inlet diameter Inc. / / / / / 1 1 1 1," 1, " " " Electrical power sup. V 0/L+NPE o 00/L+NPE 00/L+NPE Thickness insulation panels (with mm 0 0 0 0 0 0 0 0 0 0 0 0 0 external insulation) Air treated capacity Fans * Standard m (ΔT C) /h.00.00.00.800.800 8.00 10.000 11.00 1.00 1.000 0.000.000.000 Plus - optional m /h.00.00.800.800 8.800 11.000 1.000 1.000 18.000 0.000.000 9.000 8.000 Numb. - 1 1 1 1 1 1 1 1 1 1 1 Model * - 10_8 10_10 1_1 1_1 ADH1 1_1 ADH1 1_1 ADH 1_1 0/0 ADH ADH00 ADH00 ADH0 ADH ADH0 ADH0 Electrical motor power capacity * Standard (00 Pa) Optional (00 Pa) Optional (00 Pa) Optional (1000 Pa) kw 0, 0, 1,1 1,,,,,, kw 1,1 1,,,,,0,,, 11 11 11 kw 1,,,,,,, 11 11 1 1 kw,,,,, 11 x, x, x, x11 x11 Noise Level (at 1 m) Standard Version db (A) 8 9 1 Ø condensing drain (ver. BC) Inc. 1/" 1/" 1/" 1/" 1/" 1/" 1/" 1/" 1/" 1/" 1/" 1/" 1/" Fumes exhaust Ø mm 100 100 100 100 100 10 10 10 00 00 00 00 00 Max Length fumex exhaust m 8 8 8 8 8 8 8 8 8 8 8 8 8 Working temperature C -0/+0 Weight ver. BL kg 00 0 0 0 90 0 90 0 80 0 0 800 990*** Weight ver. BC kg 0 0 80 00 0 10 0 80 0 10 80 890 900*** (*) The electrical power and the models of fan can vary according to the efficiency and the prevalence. (**) Standard condition (***) The model of the fan and the electrical power of the motor can be different from the ones indicated in the technical sheet, according to the efficiency and the prevalence of the equipment. For any further information we kindly ask you to get in touch with the Technical Department of Systema S.p.A.

EOLO VIP, EOLO B BC, EOLO B BC RT: Integrated functions The board installed inside the heater represents the electronic brain of the equipment. It has been designed to guarantee a huge range of functions, which can be set using our control panels. These functions can be used profitably when the equipment is combined with Systema control panels. working programs: 1) Manual OFF: keeps just the anti-freeze condition (if enabled) ) Auto: thermal power according to the set program and timer and also ventilation in the Eolo VIP AE models ) Manual ON: keeps just the condition set by the comfort program working modalities: 1) Automatic modulation of the minimum and maximum thermal power power according to the internal and external temperature (with optional external ) ) Automatic modulation of the thermal power and constant air flow temperature Functions: - Thermostat with programmable temperatures (comfort and economy program) - Timer with daily, weekly programming and holiday function - Summer ventilation function - Air intake dumper that can be regulated according to winter or summer function and ON/OFF modalities, only with centrifugal fan models - Automatic modulation of the air capacity in EOLO VIP AE models - Possibility to connect optional safety devices (up to ): minimum gas pressure switch, air filter pressure switch, other types of safety devices - Anti-freeze function (standard) and possibility to install low temperature kit (optional) for temperatures up to -0 C CODE 0CNAC09 Standard Touch control panel for 1 hot air heater EOLO VIP, EOLO B BC, EOLO B BC RT EOLO B EOLO B RT þ Control of all the functions of Eolo (Eolo vip, Eolo B, Eolo B RT) hot air heater. It can be connected directly to the equipment (1 for each heater) till a distance of 0 meters. COD. 0CEQU11 -> It is possible to use this panel to control a specific zone, its internal temperature can be set as environment temperature as well as zone once the heater has been connected to the Master control panel SYS80, or SYS80. -> We suggest the use of these type of control panels till heaters, at maximum ( control panels). For more heaters it is better to use Master SYS80 or SYS80 control panel. Standard control panel CODE 0CEQU11 EOLO VIP

Master panel SYS80 and SYS80 for EOLO VIP, EOLO B BC, EOLO B BC RT SYS80 conceived to manage up to 0 air heaters - SYS80 conceived to manage up to 1 air heaters SYS80 and SYS80 are available in versions: þ SYS80 Basic version - Code 0CEQU1 Control up to 0 air heaters with 1 thermal zone per each burner, i.e. 0 indipendent thermal zones. þ SYS80 Basic version - Code 00CEQU Control up to 1 air heaters with n 1 thermal zone per each burner, i.e. 1 independent thermal zones. þ SYS80 LAN - Code 0CEQU18 þ SYS80 LAN - Code 00CEQU -> Besides the main functions of the Basic versions, SYS80 LAN and SYS80 LAN control panels are also equipped with Ethernet LAN (TCPIP) door for the PC monitoring in a network and through the Internet via EYE-LAN Software in versions (LITE, PLUS and ADVANCED), which can be activated in accordance with the specific needs of the user. þ SYS80 ModBUS - Code 0CEQU1 þ SYS80 ModBUS - Code 00CEQU -> Besides the main functions of the Basic versions, SYS80 ModBUS and SYS80 ModBUS control panels are equipped with a specific communication port necessary for the control through the Modbus communication system. SYS80/SYS 80 Master control panel Example of installation with thermal zones and EOLO heaters controlled by SYS80 or SYS80 SYS80/SYS 80 EOLO EOLO EOLO N Zone Environment temperature CODE 0CEGL001 Example of installation with or more zones and EOLO heaters controlled by SYS80 or SYS80 The heater EOLO is also provided with local control using the Standard Touch control panel, featuring an integrated temperature into the control panel. SYS80/SYS 80 EOLO EOLO EOLO N Zone Zone N Environment temperature CODE 0CEGL001 Standard Touch control panel CODE 0CEQU11 Environment temperature CODE 0CEGL001

Example of installation with or more zones and EOLO heaters controlled by SYS80 or SYS80 The heater uses a remotable environment temperature and uses the local control by Standard Touch control panel, while the heater EOLO is provided with local control using the standard control panel, featuring an integrated temperature into the control panel. SYS80/SYS80 EOLO EOLO EOLO N... Zone Zone Zone N... Standard Touch control panel CODE 0CEQU11 Environment temperature CODE 0CEGL001 Standard Touch control panel CODE 0CEQU11 Environment temperature CODE 0CEGL001 Example of installation with or more zones and EOLO heaters controlled by SYS80 or SYS80 All heaters EOLO are equipped with local control using the Standard Touch control panel, featuring an integrated temperature into the control panel. SYS80/SYS80 EOLO EOLO Zone EOLO N... Zone Zone N... Standard Touch control panel CODE 0CEQU11 Standard Touch control panel CODE 0CEQU11 Example of installation with or more zones and EOLO heaters controlled by SYS80 or SYS80 All heaters EOLO are equipped with environment temperature. SYS80/SYS80 EOLO EOLO Zone Environment temperature CODE 0CEGL001 8 EOLO N... Zone Zone N... Environment temperature CODE 0CEGL001

INET control panel for control up to 1 air heaters EOLO BLULINE, EOLO B BL, EOLO B BL RT Functions of EOLO combined with INET control panel: - - Automatic functioning according to the set programs and timer, for all the models, and modulation of the thermal power according to the programs, in the modulating Eolo BL version - working temperatures, - Daily/weekly temperature, timer, hour counter and holiday function - Automatic modulation of the thermal power according to the internal temperature (only for modulating EOLO BL) - Summer ventilation independent from the control panel connectable on request - Anti-freeze function (standard) and possibility to install low temperature kit (optional) for temperatures up to -0 C - CODE 0CNAC09 INET control panel up to 1 heaters: 1 thermal zone CODE 9CECR9 thermal zones CODE 9CECR9 thermal zones CODE 9CECR9 thermal zones CODE 9CECR98 Example of installation with 1 zone and EOLO BLULINE, EOLO B BL, EOLO B BL RT controlled by INET INET CODE 9CECR9 EOLO EOLO Environment temperature CODE 0CEGL001 Example of installation with zones and EOLO BLULINE, EOLO B BL, EOLO B BL RT controlled by INET EOLO 8 EOLO 9 INET CODE 9CECR9 Zone Environment temperature CODE 0CEGL001 Example of installation with zones and EOLO BLULINE, EOLO B BL, EOLO B BL RT controlled by INET EOLO EOLO 1 INET CODE 9CECR9 Zone Zone 9 Environment temperature CODE 0CEGL001

Example of installation with zones and EOLO BLULINE, EOLO B BL, EOLO B BL RT heaters controlled by INET EOLO EOLO EOLO 8 INET CODE 9CECR98 Zone Environment temperature CODE 0CEGL001 EOLO 9 Zone Zone EOLO BLULINE, EOLO B BL, EOLO B BL RT functions combined with CE control panel ON/OFF CE control panel with thermostat and integrated environment, ON/OFF function for 1 heater. CODE 0CEQU11 CE control panel with digital thermostat, remote environment and ON/OFF function: - Standard version, digital temperature control for 1 heater CODE 0CEQU10 - Version with Chrono-thermostat with daily/weekly program and timer for 1 heater CODE 0CEQU10 Common functions of EOLO BLULINE, EOLO B BL, EOLO B BL RT combined with all of the CE control panels type: - Summer ventilation independently from the matched control panel - Manual regulation of the thermal power by potentiometer (optional) - Remote Reset button independently from the matched control panel - Thermal power regulation by PLC (0-Volt control) (optional) - Double-stage function at power levels by bithermostat (optional) - Possibility to install low temperature kit (optional) for temperatures up to -0 C - CODE 0CNAC09 10

EOLO B REFERENCES AND APPLICATIONS INSTALLATION OF EOLO B WITH CANALIZATION INSTALLATION OF EOLO B WITH WAYS DUCT INSTALLATION OF EOLO B WITH CANALIZATION INSTALLATION OF EOLO B RT ON THE ROOF 11

HEATING COOLING GREEN ENERGY SYSTEMA S.p.A. Via Antonio Ceccon, - Loreggia C.A.P. 010 PADOVA - ITALY Tel. +9.09.9 r.a. - export@systema.it www.systema.it In order to improve the quality of its products, Systema S.p.A. reserves the right to modify its features without prior notice. Stampato il 10-01 - Revisione n 0IT