Columbia Boiler Company

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3

EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75

OIL-FIRED CAST IRON HOT WATER BOILER. Parts and Optional Accessories

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

Single stage operation oil burner

EC/ECT. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

Replacement parts EG/PEG

G615/11 Cast Iron Boiler

G315/6 Cast Iron Boiler

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

G315/5 Cast Iron Boiler

WBV/WV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

G515/7 Cast Iron Boiler

SLANT/FIN BOILERS TRADE PRICE BOOK

WBV/WV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

Beckett Oil Burner Parts

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

EUTECTIC EC-10 INSTALLATION AND OPERATING INSTRUCTIONS SERVICE COMPANY OIL-FIRED WATER BOILERS/NO. 2 OIL. Name Address. Telephone Model # Serial #

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

Single stage operation oil burner

EXCELSIOR. High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS

About Carlin. Visit our website, or call us at to learn more about this authentic Made-in-America company.

WV-DV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

NOW. Fall Heating Specials. Stock Up. & $ave! Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us!

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

PEERLESS BOILER PRODUCT REVIEW

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

Unmatched high efficiency product selection

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

OIL-FIRED CENTRAL FURNACE

Price - $ /12

INSTALLATION, OPERATING and SERVICE MANUAL

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON

Keeping Families Comfortable For More Than 60 Years

Indiana WX Oil Furnace Inspection Guide

Keeping Families Comfortable For More Than 60 Years

MAX. Installation, Operation and Maintenance Instructions. Residential Oil-Fired Boiler

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

DOMESTIC WATER HEATER OIL FIRED

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

WARNING. Keep area around vent terminal free of snow, ice, and debris.

TABLE OF CONTENTS BRADFORD WHITE BOILERS

XL-2000 INSTALLATION AND OPERATING INSTRUCTIONS OIL-FIRED WATER BOILERS/NO. 2 OIL SERVICE COMPANY. Name Address. Telephone Model # Serial #

RETROFIT APPLICATIONS ONLY

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

99FRD 102CRD EZ-66. Instruction Manual. Advanced Oil Burners. 0.5 to 4.5 GPH. Contents. Ratings

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR V7 SERIES OIL FIRED BOILER KNOCKDOWN & PACKAGED HEATING UNITS

AFII. FII Oil. Instruction Manual MODEL. Burner. AFII 85, AFII 100, AFII 150 Types HLX & FBX air tube combinations Voltage: 120 Vac / 60 Hz

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

Product Catalog Burners Ignitors Controls

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Instruction manual. Carlin Combustion Technology, Inc. 126 Bailey Road North Haven, CT Ph Fx

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190

Light oil - kerosene burner

Installation, Operation and Service Manual

Series. Gas/Oil Boilers Water. Oil, Gas & Installation, Operation & Maintenance Manual

Boiler Manual. Gas-fired water boilers. Featuring. Flexibility

SCS SCS

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Boiler & Water Heater

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

TC II. Series. Oil, Gas & Gas/Oil Boilers. Installation, Operation & Maintenance Manual

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave!

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

Peerless Boilers. Series MI. Residential Gas Boilers

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS CL SERIES CAST IRON OIL-FIRED BOILER

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Suggested Specifications Prestige Excellence 110

G215 G315 Cast Iron Residential Boilers

INSTALLATION, OPERATING and SERVICE MANUAL

Instruction manual. Ratings. Contents. Carlin Combustion Technology, Inc. 126 Bailey Road North Haven, CT Phone Fax

oil furnaces BCL, BFL, BML, BMLV 60, ,000 BTU HML, HMLV, HTL, HTLV 60, ,000 BTU Multiposition WML, WMLV, MPL 60, ,000 BTU

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Installation, Operation and Service Manual

PROFIRE -E SERIES BURNERS

SUPPLEMENTAL INSTRUCTIONS: DIRECT VENT INSTRUCTIONS FOR HIGH EFFICIENCY OIL-FIRED HOT WATER BOILER

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

BOCK RESIDENTIAL OIL-FIRED WATER HEATERS

STARFIRE IV WATER OIL FIRED CAST IRON BOILER

QHT Manual for: SU-2A Gas Burner

SB615/310 Stainless Steel Condensing Boiler

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

INSTALLATION INSTRUCTIONS

Keeping Families Comfortable For More Than 60 Years

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

Transcription:

FP Series s BECKETT OEM OIL BURNER CONFIGURATION Burner Model ATC Head Type Head setting/ firing pin Nozzle or Gas Orifice Size Air Pump or Manifold Pressure Baffle Solenoid Valve Flange Flange Insertion depth Flange Pitch Flange Rotation FP 24 Oil AFII HLX5HB 6-slot 4.65 X 6 o B (H) 4. 16(psig) 31769 None 316743 2 5/8 1 o o FP 24 Oil AFII HLX5HB 6-slot 6.85 X 45 o B (H) 5.5 16(psig) 31769 None 316743 2 5/8 1 o o FP 24 Oil AFII 15 HLX5HB 6-slot 4.85 X 45 o B (H) 3.5 16(psig) None None 316743 2 5/8 1 o o FP 24 Oil AFII 15 HLX5HB 6-slot 6 1. X 45 o B (H) 5. 16(psig) None None 316743 2 5/8 1 o o Manufacturing 43 E Cherry Road Quakertown PA 18951 (215) 536-478 Fax: (215) 536-896

SPECIFICATIONS FOR DYNATHERM FPB MODELS 24 & 36 WITH CARLIN SERIES 99CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 99-48CRD BURNER FPB MODELS 24 & 36 WITH CARLIN SERIES CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 11-48CRD BURNER RECOMMENDED SETTINGS FOR 99 CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS BLANK AIR SHUTTER RECOMMENDED SETTINGS FOR 99-48 CRD BURNER USED WITH MOD 48 FPB BOILER OPEN AIR SHUTTER Air Band % Air Band %.85 1/8 2 1.5 3/16 2 1. 1/8 3 1.65 1/4 5 1.1 1/8 4 1.75 5/16 5 1.25 1/8 4 1.35 3/16 5 1.5 3/16 6 RECOMMENDED SETTINGS FOR CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS WITH DELAY OIL VALVE RECOMMENDED SETTINGS FOR 11-48 CRD MODEL 48 FPB WITH 5-1/16" DIA. BLOWER WHEEL NO DELAY OIL VALVE Air Shutter Air Band Air Shutter Air Band.85 Min. 1/8 Max. 1/4 1. Min. 3/16 Max. 5/16 1.1 Min. 3/32 Max. 1/4 1.25 Min. 7/16 Max. 9/16 7 2 8 2 7 3 5 1.5 1.4 5 1.65 5/16 5 1.75 3/8 5 1.35 Min. 7/16 Max. 9/16 1.5 Min. 7/16 Max. 5/8 5 2 NOZZLE SPECIFICATIONS MODEL 99 CRD AND CRD MODEL 99-48 CRD AND 11-48 CRD 45 o semi-solid Hago 45 o Steinen Q 45 o Monarch R 45 o Monarch AR 45 o Steinen S

RATINGS & DATA Gross Output MBH D.O.E. A.F.U.E. Efficiency % Nozzle Size Gross Stack Temperature F Net Hot Water MBH Net Hot Water Sq.Ft. 24A 14 85.2.85 318 9.4 63 24B 118 84. 1. 35 12.6 684 24C 146 82.1 1.25 418 127. 847 36A 152 85.5 1.25 295 132.2 881 36B 163 85.3 1.35 38 141.7 945 36C 182 84.1 1.5 336 158.3 155 48A 188 87.5 1.5 249 163.5 19 48B 23 87.1 1.65 266 176.5 1177 48C 212 86.5 1.75 281 184.3 1229 FP/B MODEL WEIGHTS AND DIMENSIONS LENGTH SHIPPING INSTALLATION CLEARANCE WEIGHT CRATED VERTICAL SIDE FRONT REAR BARE BOILER SKID JACKET BURNER WIDTH HEIGHT 24 23" 35" 33" 13" 19" 34" 555 6" 12" 18" 24" 36 35" 47" 44" 13" 19" 34" 665 6" 12" 18" 24" 48 47" 59" 56" 13" 19" 34" 775 6" 12" 18" 24" DOMESTIC WATER OUTPUT Standard Equipment MODEL Intermittent G.P.M. Continuous G.P.H. Flame Retention Oil Burner Flush Jacket Insulation 24A 4 133 Primary Control Dual Connections for Temperature & Vent & Return Piping 24B 4 151 Pressure Gauge Oil Valve 24C 4 187 Water Features Tankless Coil 36A 4 195 Combination High Limit/Low Limit Operating Control and Circulator Relay 36B 4 29 Steam Features 36C 4 234 Low Water Cutoff Operating Control Safety Valve Water Gauge 48A 5 24 Pressure Control Compound Gauge 48B 5 26 Optional Equipment Two-Stage Fuel Unit Tankheater Coil 48C 5 27 Dual Tankless Coil Jacket Extension 43 E CHERRY RD, QUAKERTOWN PA 18951 (215) 536-478 FAX: (215) 536-896 VISIT OUR WEB SITE AT WWW. DYNATHERMBOILER.COM

DYNATHERM FP Series s CARLIN OEM GAS BURNER CONFIGURATION Appliance Venting arrangement Burner Model Control Pre/Post Purge Natural Gas orifice Natural Gas Air Propane Orifice Propane Air FP 18 Gas EZ-GAS 91 MBH 13/64 15% 9/64 12% FP 18 Gas EZ-GAS 15 MBH #3 (.213 ) 22% 9/64 23% FP 18 Gas EZ-GAS 119 MBH 15/64 32% 11/64 33% FP 18 DV EZ-GAS 91 MBH DV 13/64 5% 9/64 6% FP 18 DV EZ-GAS 15 MBH DV #3 (.213 ) 8% #21 (.159) 8% FP 18 DV EZ-GAS 119 MBH DV 15/64 11% 11/64 12% FP 24 Gas EZ-GAS 119 MBH 15/64 41% 11/64 42% FP 24 Gas EZ-GAS 14 MBH 17/64 6% 13/64 6% FP 24 Gas EZ-GAS 175 MBH 5/16 9% B (.238 ) 9% FP 24 DV EZ-GAS 119 MBH DV 15/64 8% 11/64 11% FP 24 DV EZ-GAS 15 MBH DV 17/64 18% 13/64 18% FP 24 DV EZ-GAS 119 MBH DV 5/16 37% B (.238 ) 28% FP 36 Gas EZ-GAS 175 MBH 5/16 5% B (.238 ) 4% FP 36 Gas EZ-GAS 189 MBH Q (.332 ) 6% F (.257 ) 53% FP 36 Gas EZ-GAS 21 MBH 3/8 83% J (.277 ) 67% FP 36 DV EZ-GAS 175 MBH DV 5/16 37% B (.238 ) 32% FP 36 DV EZ-GAS 189 MBH DV Q (.332 ) 43% F (.257 ) 42% FP 36 DV EZ-GAS 21 MBH DV 3/8 75% J (.277 ) 85% A) 3 ½ Water Column Manifold Pressure B) 4 long orificed nipple used, orifice toward gas valve DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA 18951 (215) 536-478 Fax: (215) 536-896 www.dynathermboiler.com

DYNATHERM FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement Pump or Flange Control Nozzle Size Air Band/ Manifold Insertion Burner Model Head Bar Pre/Post Purge Air Boot Pressure depth FP 18 Oil EZ-1 PRO 622 1/1.55 X 45 o B.6.5 15(psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.65 X 45 o B.65.6/.65 15(psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.75 X 45 o B.75.75 15(psig) 3. to flange FP 18 DV EZ-1 PRO 622 15/12.55 X 45 o B.45.6/.65 15(psig) 3. to flange FP 18 DV EZ-1 PRO 622 15/12.65 X 45 o B.55.75 15(psig) 3. to flange FP 18 DV EZ-1 PRO 622 15/12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.75 X 45 o B.75.75 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.85 X 45 o B.85.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B 1.1 1.1/ 1.25 15(psig) 3. to flange FP 24 DV EZ-1 PRO 622 15/12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 DV EZ-1 PRO 622 15/12.85 X 45 o B.85 1.1/ 1.25 15(psig) 3. to flange FP 24 DV EZ-1 PRO 622 15/12 1.1 X 45 o B 1.15 1.35/ 1.5 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1. X 45 o B 1.15.85/ 1. 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B 1.15 1.1/ 1.25 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1.25 X 45 o B 1.2 1.35/ 1.5 15(psig) 3. to flange FP 36 DV EZ-1 PRO 622 15/12 1. X 45 o B 1.2 1.1/ 1.25 15(psig) 3. to flange FP 36 DV EZ-1 PRO 622 15/12 1.1 X 45 o B 1.2 1.35/ 1.5 15(psig) 3. to flange FP 36 DV EZ-1 PRO 622 15/12 1.25 X 45 o B 1.6 1.65 15(psig) 3. to flange A) All B oil burner nozzles listed above for EZ-1 Pro Oil burner are Hago or Delavan B) All Air tubes for above burners are 7 in length DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA 18951 (215) 536-478 Fax: (215) 536-896 www.dynathermboiler.com

DYNATHERM FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement EZ-1/ 99FRD Burner Model Control Nozzle or Gas Orifice Size Air Turbulator or Head setting Pump or Manifold Pressure Flange Insertion depth FP 24 Oil EZ-1HP 62 1/1.75 X 45 o B.65.75 14(psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1 1.1 X 45 o B 1.1.85/1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.75 X 45 o B.75.75 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12 1.1 X 45 o B 1.6 1.1/1.25 14(psig) 2.75 to flange FP 18 99FRD 48245.65 X 45Q 15%. (psig) 3. to flange FP 18 99FRD 48245.85 X 45Q 25% 1. (psig) 3. to flange FP 18 99FRD 48245 1. X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD 48245.85 X 45Q 25% 1. (psig) 3. to flange FP 24 99FRD 48245 1. X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD 48245 1.25 X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD 48245 1.25 X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD 48245 1.35 X 45Q 55% 2. (psig) 3. to flange FP 36 99FRD 48245 1.5 X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD 48245 1.5 X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD 48245 1.65 X 45Q 75% 3. (psig) 3. to flange FP 42 99FRD 48245 1.75 X 45Q 8% 3. (psig) 3. to flange C) All B oil burner nozzles listed in above setup chart for EZ-1 Oil burner are Hago or Delavan D) All Q oil burner nozzles listed in above setup chart for 99FRD Oil burner are Steinen E) All Air tubes for above burners are 5 in length DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA 18951 (215) 536-478 Fax: (215) 536-896 www.dynathermboiler.com

Nozzle Interchange Chart Spray Angles 3 o through 9 o HAGO/SID HARVEY H A SS (up to 2.) SS SS (over 2.) A or W ES/P B* B B* MONARCH NS/PL A R/AR (up to 2.) R-D/AR-D R/AR (over 2.) A/A or W PLP B* DANFOSS AS W or B AH A *The original B Nozzle

Burner Manufacturer s Recommendations* Manufacturer Model Delavan Nozzle F-AFC 8 o W, A or B HF-US 8 o W, A or B Aero Burner HF-AFC 8 o W, A or B SV-SSV 7 o or 8 o B AF/FG (F) 6 o, 7 o or 8 o A or B (-15 PSI) R.W. AF/AFG (M) 6 o or 7 o A or B (-15 PSI) Beckett AFII (FB) 45 o, 6 o or 7 o A, W or B (14-2 PSI) AFII (HLX) 45 o, 6 o or 7 o A, W or B (14-2 PSI) 99 FRD (Std.).5 -.75 GPH 6 o A.85-3. GPH 45 o A, 6 o A or B CRD (Std.).5 -.75 GPH 6 o A.85-2.25 GPH 45 o A, 6 o A or B The Carlin Co. Riello Burners Intertherm Wayne Home Equipment Weil-McLain.75-1.1 GPH 6 o Elite EZ-1.5-1. GPH 7 o A.5 -.85 GPH 6 o SS 1. - 1.65 GPH 6 o or 7 o Elite (EZ-2,3) All Flow s 6 o A, B or SS Mectron 3M 6 o W, B, or Del-O-Flo A 5M (Up to.85 GPH) F3, F5.4-1.25 GPH 6 o or 8 o W or A F1 1.25-2.5 GPH 6 o W or B F15, F2 2. - 5. GPH 45 o or 6 o W or B R35.3, R35.5.5-1.25 GPH 6 o or 8 o W or B Press Series 2. - 12. GPH 6 o or 45 o B or W MAC 1265 P/N 661-181 or.55 GPH 9 o W or.579 MH MSH 66.5 8 o A MSH 86.65 8 o A P.5 1. GPH 6 o, 7 o, or 8 o A or B EHASR.75 3. GPH 8 o, 7 o, or 6 o ** MSR.75 2.75 GPH 8 o, 7 o, or 6 o ** HS.5 2.5 GPH 8 o, 7 o, or 6 o ** HS.5 3. GPH 8 o, 7 o, or 6 o B EG-1.5 3. GPH 8 o, 7 o, or 6 o ** **Under 1. GPH use A; above 1. use B QB18 (15 PSI).55 1.8 GPH 45 o, 6 o, 7 o, 8 o A or B QB18 (14 PSI) 1.75 3. GPH 45 o, 6 o, 7 o, 8 o B *Effective November 1999. Subject to updating by burner manufacturers. For s not listed, contact burner manufacturer. Always follow the appliance manufacturer s instructions for the correct nozzle specification. For more current information, please visit our website at www.delavaninc.com. NOTE: Information on this chart is to be used as a general guide only.

Recommended Nozzle Sizes for s MODEL BURNER BRAND GPH DEGREE SPRAY RIELLO.65.75 8 or 6 SOLID.85 18 BECKETT AFII 15 HAGO.65.75 45 SOLID.85 CARLIN HAGO/.65.75 45 SOLID.85 24 RIELLO BECKETT AFII 15 CARLIN HAGO HAGO/.75.85 1..75.85 1..75.85 1. 8 or 6 SOLID 45 SOLID 45 SOLID 36 RIELLO BECKETT AFII 15 CARLIN HAGO HAGO/ 1. 1.1 1.25 1. 1.1 1.25 1. 1.1 1.25 8 or 6 SOLID 45 SOLID 45 SOLID 42 RIELLO CARLIN HAGO/ 1.1 1.25 1.35 1.1 1.25 1.35 45 SOLID 45 SOLID 48 RIELLO CARLIN HAGO/ 1.5 1.75 2. 1.5 1.75 2. 3 SOLID 45 SOLID

DYNATHERM BOILERS DYNATHERM FP Series s RIELLO OEM OIL BURNER CONFIGURATION Appliance Venting arrangement rate input Nozzle or Pump or Flange Burner Model value US Gas Orifice Air Gate Turbulator or Manifold Insertion gph or BTU/Hr. Size Head setting Pressure depth FP 24 Oil 4 F5 w/sbt.85.75 X 8 o B 2.8. 145(psig) 2.5 to flange FP 24 Oil 4 F5 w/sbt 1..85 X 8 o B 3. 1. 145(psig) 2.5 to flange FP 24 Oil 4 F5 w/sbt 1.25 1.1 X 8 o B 3.25 3. 145(psig) 2.5 to flange FP 24 DV 4 BF5 w/sbt.85.75 X 8 o B 3.5. 145(psig) 2.5 to flange FP 24 DV 4 BF5 w/sbt 1..85 X 8 o B 4. 1. 145(psig) 2.5 to flange FP 24 DV 4 BF5 w/sbt 1.25 1.1 X 8 o B 5.5 3. 145(psig) 2.5 to flange FP 24 gas 4 G2 w/sbt 119, 2.mm 2. 2..85 o w.c. Fixed FP 24 gas 4 G2 w/sbt 14, 2.mm 2.25 3. 1. o w.c. Fixed FP 24 gas 4 G2 w/sbt 175, 2.mm 3. 4. 1.45 o w.c. Fixed FP 48 Oil 4 F1 w/lbt 1.65 1.5 X 3 o B 3. 2. 145(psig) 2.5 to flange FP 48 Oil 4 F1 w/lbt 2. 1.75 X 3 o B 4. 3. 16(psig) 2.5 to flange FP 48 Oil 4 F1 w/lbt 2.25 2. X 3 o B 5. 4. 155(psig) 2.5 to flange FP 48 gas 4 G2 (see note C ) 231, FP 48 gas 4 G2 (see note C ) 28, FP 48 gas 4 G2 (see note C ) 315, NO DATA AVAILABLE A) All oil burner nozzles listed in above setup chart = Delavan B) FP 48 boiler with F1 oil burner utilized a OEM specific milled aluminum type turbulator disk see OEM part number below C) FP 48 boiler with 4 G4 gas burner: No application data available D) All Gas burner installations must have a minimum of 6 of gas supply pressure measured at the inlet of gas valve during a firing cycle to obtain proper input value. E) All chimney applications must utilize a draft regulator (single acting oil) & (double acting gas) and draft pressure in breech to be set @ -.2 to.4 WC F) All OEM configurations and settings listed above are a starting point only. OEM spare parts list 4 F3 4 F5 4 F1 4 G2 4 G4 Flange C6841 C6841 C6841 C6841 N/A Gasket C68819 C68819 C68819 C68819 N/A part # C6563

SPECIFICATIONS FOR DYNATHERM FPB MODELS 24 & 36 WITH CARLIN SERIES 99CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 99-48CRD BURNER FPB MODELS 24 & 36 WITH CARLIN SERIES CRD BURNERS FPB MODEL 48 WITH CARLIN SERIES 11-48CRD BURNER RECOMMENDED SETTINGS FOR 99 CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS BLANK AIR SHUTTER RECOMMENDED SETTINGS FOR 99-48 CRD BURNER USED WITH MOD 48 FPB BOILER OPEN AIR SHUTTER Air Band % Air Band %.85 1/8 2 1.5 3/16 2 1. 1/8 3 1.65 1/4 5 1.1 1/8 4 1.75 5/16 5 1.25 1/8 4 1.35 3/16 5 1.5 3/16 6 RECOMMENDED SETTINGS FOR CRD BURNER USED WITH MOD 24 & 36 FPB BOILERS WITH DELAY OIL VALVE RECOMMENDED SETTINGS FOR 11-48 CRD MODEL 48 FPB WITH 5-1/16" DIA. BLOWER WHEEL NO DELAY OIL VALVE Air Shutter Air Band Air Shutter Air Band.85 Min. 1/8 Max. 1/4 1. Min. 3/16 Max. 5/16 1.1 Min. 3/32 Max. 1/4 1.25 Min. 7/16 Max. 9/16 7 2 8 2 7 3 5 1.5 1.4 5 1.65 5/16 5 1.75 3/8 5 1.35 Min. 7/16 Max. 9/16 1.5 Min. 7/16 Max. 5/8 5 2 NOZZLE SPECIFICATIONS MODEL 99 CRD AND CRD MODEL 99-48 CRD AND 11-48 CRD 45 o semi-solid Hago 45 o Steinen Q 45 o Monarch R 45 o Monarch AR 45 o Steinen S

RATINGS & DATA Gross Output MBH D.O.E. A.F.U.E. Efficiency % Nozzle Size Gross Stack Temperature F Net Hot Water MBH Net Hot Water Sq.Ft. 24A 14 85.2.85 318 9.4 63 24B 118 84. 1. 35 12.6 684 24C 146 82.1 1.25 418 127. 847 36A 152 85.5 1.25 295 132.2 881 36B 163 85.3 1.35 38 141.7 945 36C 182 84.1 1.5 336 158.3 155 48A 188 87.5 1.5 249 163.5 19 48B 23 87.1 1.65 266 176.5 1177 48C 212 86.5 1.75 281 184.3 1229 FP/B MODEL WEIGHTS AND DIMENSIONS LENGTH SHIPPING INSTALLATION CLEARANCE WEIGHT CRATED VERTICAL SIDE FRONT REAR BARE BOILER SKID JACKET BURNER WIDTH HEIGHT 24 23" 35" 33" 13" 19" 34" 555 6" 12" 18" 24" 36 35" 47" 44" 13" 19" 34" 665 6" 12" 18" 24" 48 47" 59" 56" 13" 19" 34" 775 6" 12" 18" 24" DOMESTIC WATER OUTPUT Standard Equipment MODEL Intermittent G.P.M. Continuous G.P.H. Flame Retention Oil Burner Flush Jacket Insulation 24A 4 133 Primary Control Dual Connections for Temperature & Vent & Return Piping 24B 4 151 Pressure Gauge Oil Valve 24C 4 187 Water Features Tankless Coil 36A 4 195 Combination High Limit/Low Limit Operating Control and Circulator Relay 36B 4 29 Steam Features 36C 4 234 Low Water Cutoff Operating Control Safety Valve Water Gauge 48A 5 24 Pressure Control Compound Gauge 48B 5 26 Optional Equipment Two-Stage Fuel Unit Tankheater Coil 48C 5 27 Dual Tankless Coil Jacket Extension 43 E CHERRY RD, QUAKERTOWN PA 18951 (215) 536-478 FAX: (215) 536-896 VISIT OUR WEB SITE AT WWW. DYNATHERMBOILER.COM

FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement Burner Model Control Nozzle or Gas Orifice Size Air Turbulator or Head setting Pump or Manifold Pressure Flange Insertion depth FP 24 Oil EZ-1HP 62 1/1.75 X 45 o B.65.75 14(psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 Oil EZ-1HP 62 1/1 1.1 X 45 o B 1.1.85/1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.75 X 45 o B.75.75 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12.85 X 45 o B.75.85/1. 14(psig) 2.75 to flange FP 24 DV EZ-1HP 62 15/12 1.1 X 45 o B 1.6 1.1/1.25 14(psig) 2.75 to flange FP 18 99FRD 48245.65 X 45Q 15%. (psig) 3. to flange FP 18 99FRD 48245.85 X 45Q 25% 1. (psig) 3. to flange FP 18 99FRD 48245 1. X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD 48245.85 X 45Q 25% 1. (psig) 3. to flange FP 24 99FRD 48245 1. X 45Q 3% 2. (psig) 3. to flange FP 24 99FRD 48245 1.25 X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD 48245 1.25 X 45Q 5% 2. (psig) 3. to flange FP 36 99FRD 48245 1.35 X 45Q 55% 2. (psig) 3. to flange FP 36 99FRD 48245 1.5 X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD 48245 1.5 X 45Q 7% 2. (psig) 3. to flange FP 42 99FRD 48245 1.65 X 45Q 75% 3. (psig) 3. to flange FP 42 99FRD 48245 1.75 X 45Q 8% 3. (psig) 3. to flange A) All B oil burner nozzles listed in above setup chart for EZ-1 Oil burner are Hago or Delavan B) All Q oil burner nozzles listed in above setup chart for 99FRD Oil burner are Steinen C) All Air tubes for above burners are 5 in length Manufacturing 43 E Cherry Road Quakertown PA 18951 (215) 536-478 Fax: (215) 536-896

DYNATHERM FP Series s CARLIN OEM GAS BURNER CONFIGURATION Appliance Venting arrangement Burner Model Control Pre/Post Purge Natural Gas orifice Natural Gas Air Propane Orifice Propane Air FP 18 Gas EZ-GAS 91 MBH 13/64 15% 9/64 12% FP 18 Gas EZ-GAS 15 MBH #3 (.213 ) 22% 9/64 23% FP 18 Gas EZ-GAS 119 MBH 15/64 32% 11/64 33% FP 18 DV EZ-GAS 91 MBH DV 13/64 5% 9/64 6% FP 18 DV EZ-GAS 15 MBH DV #3 (.213 ) 8% #21 (.159) 8% FP 18 DV EZ-GAS 119 MBH DV 15/64 11% 11/64 12% FP 24 Gas EZ-GAS 119 MBH 15/64 41% 11/64 42% FP 24 Gas EZ-GAS 14 MBH 17/64 6% 13/64 6% FP 24 Gas EZ-GAS 175 MBH 5/16 9% B (.238 ) 9% FP 24 DV EZ-GAS 119 MBH DV 15/64 8% 11/64 11% FP 24 DV EZ-GAS 15 MBH DV 17/64 18% 13/64 18% FP 24 DV EZ-GAS 119 MBH DV 5/16 37% B (.238 ) 28% FP 36 Gas EZ-GAS 175 MBH 5/16 5% B (.238 ) 4% FP 36 Gas EZ-GAS 189 MBH Q (.332 ) 6% F (.257 ) 53% FP 36 Gas EZ-GAS 21 MBH 3/8 83% J (.277 ) 67% FP 36 DV EZ-GAS 175 MBH DV 5/16 37% B (.238 ) 32% FP 36 DV EZ-GAS 189 MBH DV Q (.332 ) 43% F (.257 ) 42% FP 36 DV EZ-GAS 21 MBH DV 3/8 75% J (.277 ) 85% FP 48 Gas 21 Gas 259 MBH 3/8 @ 3.3 WC 4% 5/16 @ 3.5 WC 4% FP 48 Gas 21 Gas 28 MBH 3/8 @ 3.7 WC 5% Let O @3.2 WC 5% FP 48 Gas 21 Gas 3 MBH 25/64 @ 3.2 WC 75% Let O @3.5 WC 75% A) 3 ½ Water Column Manifold Pressure FP 18, 24, 36 B) 4 long orificed nipple used, orifice toward gas valve DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA 18951 (215) 536-478 Fax: (215) 536-896 www.dynathermboiler.com

DYNATHERM FP Series s CARLIN OEM OIL BURNER CONFIGURATION Appliance Venting arrangement Pump or Flange Control Nozzle Size Air Band/ Manifold Insertion Burner Model Head Bar Pre/Post Purge Air Boot Pressure depth FP 18 Oil EZ-1 PRO 622 1/1.55 X 45 o B.6.5 15(psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.65 X 45 o B.65.6/.65 15(psig) 3. to flange FP 18 Oil EZ-1 PRO 622 1/1.75 X 45 o B.75.75 15(psig) 3. to flange FP 18 DV EZ-1 PRO 622 15/12.55 X 45 o B.45.6/.65 15(psig) 3. to flange FP 18 DV EZ-1 PRO 622 15/12.65 X 45 o B.55.75 15(psig) 3. to flange FP 18 DV EZ-1 PRO 622 15/12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.75 X 45 o B.75.75 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1.85 X 45 o B.85.85/ 1. 15(psig) 3. to flange FP 24 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B 1.1 1.1/ 1.25 15(psig) 3. to flange FP 24 DV EZ-1 PRO 622 15/12.75 X 45 o B.65.85/ 1. 15(psig) 3. to flange FP 24 DV EZ-1 PRO 622 15/12.85 X 45 o B.85 1.1/ 1.25 15(psig) 3. to flange FP 24 DV EZ-1 PRO 622 15/12 1.1 X 45 o B 1.15 1.35/ 1.5 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1. X 45 o B 1.15.85/ 1. 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1.1 X 45 o B 1.15 1.1/ 1.25 15(psig) 3. to flange FP 36 OIL EZ-1 PRO 622 1/1 1.25 X 45 o B 1.2 1.35/ 1.5 15(psig) 3. to flange FP 36 DV EZ-1 PRO 622 15/12 1. X 45 o B 1.2 1.1/ 1.25 15(psig) 3. to flange FP 36 DV EZ-1 PRO 622 15/12 1.1 X 45 o B 1.2 1.35/ 1.5 15(psig) 3. to flange FP 36 DV EZ-1 PRO 622 15/12 1.25 X 45 o B 1.6 1.65 15(psig) 3. to flange FP 48 OIL EZ-66 622 3/3 1.5 x 3ºB 8% 6-8 set @ 7 15(psig) 3. to flange FP 48 OIL EZ-66 622 3/3 1.65 x 3ºB % 6-8 set @ 7 15(psig) 3. to flange A) All B oil burner nozzles listed above for EZ Oil burner are Hago or Delavan B) Air tubes for FP 18,24,36 burners are 7 in length C) Air Tube for FP48 Burner is 11 in length DYNATHERM Manufacturing 43 E Cherry Road Quakertown PA 18951 (215) 536-478 Fax: (215) 536-896 www.dynathermboiler.com