Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Similar documents
Industrial Explosion Suppression Technology

A Global Leader in Explosion Protection

Protecting Critical Facilities Against Explosions

There are always options in the management of explosion risks!

Dust Explosions. health & environmental sciences failure analysis & prevention

With CV Technology products and care, you ll be better protected from dust explosions.

Protecting Facilities Against Explosions. Since 1956

GEAPS Great Lakes Regional Conference 2017 Explosion Protection Overview & Market Drivers. April 6, 2017

Advances in Explosion Protection Technology. Dr. John E. Going Fike Corporation Blue Springs, MO

Industrial Dust Explosions Causes & Case Studies. Presented by Geof Brazier at Expocorma, Concepcion, Chile 10th November 2017

Guide - Basic Information

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Property risk solutions

Dust Explosion Hazard Overview

Combustible Dust Hazards- Awareness

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

Combustible Dust Booklet

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Managing Combustible Dust

Industrial Explosion Protection. Every human being has the right to live in a safe environment, free of needless risks.

Safe installations are also cost effective installations

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

Aluminum Dust Management in a Metallizing Facility

Combustible Dust Issues

Explosion Protection. Process Safety. Quality Solutions.

WHITE PAPER Dust Hazard Analysis for Simple Dust Collection Systems

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

EXPLOSION PROTECTION MAES SAFETY PRODUCTS & SERVICES

Leading Trends in Chemical Processing

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

COMBUSTIBLE DUST HAZARD MITIGATION

OUTDOOR INSTALL NO RETURN AIR SINGLE MODULE COLLECTORS OUTDOOR INSTALL WITH RETURN AIR SINGLE MODULE COLLECTORS

Dust Explosions. by Clive de Salis. Telephone: +44 (0)

Combustible Dust Awareness. David McEwan Business Line Manager Configured Products

Jason Reason. NFPA Technical Committees

2012 International Symposium on Safety Science and Technology Advances in dust explosion protection techniques: flameless venting

AUTOMATIC FIRE SUPPRESSION SYSTEMS

EXPLOSION PROTECTION INTEGRATED COMPONENTS EXPLOSION PROTECTION SOLUTIONS EXPLOSION PROTECTION INNOVATIVE, RELIABLE, PATENTED TECHNOLOGIES

THE PACESETTER IN EXPLOSION SAFETY INNOVATION EXPLOSION PROTECTION SOLUTIONS YOU CAN COUNT ON WORLDWIDE.

Dust Collection Tips to Keep Free-From Foods Safe from Cross-Contamination

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing

Managing explosive dust risk in sugar handling

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

// Explosion Isolation. No matter what happens - nothing happens. /

Smoke detection in hazardous areas:

Flameless Venting The New Technology for Safe Indoor Explosion Venting

White Paper EXPLOSION PROTECTION EXPLOSION PROTECTION SOLUTIONS FOR SANITARY HYGIENIC APPLICATIONS IN THE FOOD & PHARMACEUTICAL INDUSTRY

General Design Practices in Reducing Risk in Grain Handling Facilities

We ve all heard about catastrophic combustible

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

Q-Box-II LF- NFPA 654

Soot Mitigation Strategies

1. Delete in its entirety as follows:

COMBUSTIBLE DUST AN EXPLOSIVE ISSUE NFPA 654

ADDITIONS TO NFPA 61, STANDARD FOR THE PREVENTION OF FIRES AND DUST EXPLOSIONS IN THE AGRICULTURAL AND FOOD PROCESSING INDUSTRIES

Combustible Dust Resources OVERVIEW OF COMBUSTIBLE DUST. What is Combustible Dust? Where are Combustible Dusts found?

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

COMBUSTIBLE DUST SAFETY PROGRAM

This Second Correlating Revision effects correct usage. This also addresses one of the Affirmative Comments to Second Revision No. 28.

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

DUST COLLECTION TRAINING. Revision 2013

Wood Pellet Mills: Dust suppression, spark detection, and extinguishing systems equipment

3/20/2017. The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard. Jason Reason. Jason Reason

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

Progressive Safety Services LLC 1

SEF Presents: Common Questions for a Chemical Safety Program. Wednesday September 20, 2017

Dust Hazard Assessments

Combustible Dust 101: Understanding Combustible Dust Hazards

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:


Above Ground Fuel Tank Requirements

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Prevention of Fires and Dust Explosions within the Biomass Handling Process. PFI July 20, 2015

M E M O R A N D U M. The Technical Correlating Committee on Boiler and Combustion Systems Hazards

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Public Input No. 3-NFPA [ Chapter 2 ]

Implementing a Combustible Dust Program. Presented by: Nick Miedema Amway EH&S For: Michigan Safety Conference

As long as ATEX has been providing Explosion. Protection Systems a truly passive System without many

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Max Fire Box Users Guide

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Where Process Safety meets Machine Safety

FlexFilter EX A state of the art filter system to meet your current and future needs

Sprinklers Modeling for Tunnel Road Fire Fighting

Pneumatic Vacuum Conveyors for the Highest Standards Transportation of bulk materials in the pharmaceutical and chemical industries

Preventing Fires And Explosions In Pilot Plants And Laboratory Units

Safety Considerations for Hydrogen Installations

Fire Protection Guidelines for Handling and Storing PRB Coal

DEFLAGRATION FIRE MARSHAL PMAX WOOD

Are Your Kitchen Hood Filters Compliant?

Transcription:

Explosion Protection System Selection Guide By Emre Ergun, MS, MBA New Product Development Manager, FENWAL Explosion Protection Systems A UTC Fire & Security Company 400 Main Street, Ashland MA 01721 Tel: 508-881-2000 emre.ergun@fs.utc.com, www.fenwalprotection.com Selecting the right explosion protection system for your combustible dust handling process can be a daunting task considering the availability of many explosion protection technologies. Over the past decade with the introduction of new suppressor and detection technologies with smarter features along with new passive protection products, the number of available explosion protection options has increased 1. Combined with increased emphasis on combustible dust hazards by OSHA 2 due to recent high profile combustible dust explosions 3,4, understanding the available explosion mitigation options has become even more important. Process owners, corporate risk managers and process engineers need to understand the available protection options and applicable regulations in order to address combustible dust hazards within their processes using the most applicable and cost effective mitigation technology. This paper provides a brief introduction to the explosion protection methods including suppression, isolation and venting. Other protection options such as pressure containment, combustible concentration reduction and inerting are also available, however not within the scope of this paper. Overview of Explosion Protection Options Before proceeding with the selection process, let s briefly look at the various explosion protection options: Explosion Venting. It is one of the most widely used techniques for mitigating dust explosions. It is based on the opening of a specifically designed weaker membrane installed on a vessel to open and direct the flame, burned/unburned material, overpressure and other combustion byproducts to a safe location during the incipient stages of an explosion. According to NFPA 68, section 8.8, in the case of dust deflagrations, the vented fireball size can be estimated using the following equation; D = K*[V/n] 1/3, where D is the axial fireball distance (m) from the vent, K is the flame length factor (8 for chemical or agri dusts, 10 for metal dusts), V is the volume of the enclosure (m 3 ), and n is the number of vents. Additionally the width of the fireball is estimated as one-half of D. For example for a vented enclosure with a volume of 1m 3 handling agricultural dust, and protected by a single vent, fireball dimension becomes approximately 8 meters with a width of 4 meters. Thus a safety distance in front of the vented vessel is required to protect against the ejecting fireball. Explosion relief vents are designed to ensure that the pressure rise due to explosion does not exceed the pressure shock resistance of the protected equipment. In the US, explosion relief vents are designed in accordance with the procedures given in NFPA 68 5. Picture 1 Various sizes and shapes of explosion relief panels Rev 110810 Page 1

Picture 2 Vented and isolated explosion Flameless Venting. This relatively new technology is finding niche applications in the process industries for protection of indoor process equipment against dust explosions. Flameless vents combine the proven explosion relief venting technology with flame arresting and controlled particle retention. Similar to explosion relief venting, its operation relies on the rupture of a weak membrane during a deflagration event where the overpressure, flame and particulate material discharges through a flame and particulate trap material, thus eliminating the flame and material discharge to surrounding areas. Only hot gas and pressure are discharged to ambient. For safety purposes, a safety perimeter around the flameless vent is required in order ensure employee safety. The ratio of the room volume to vented vessel volume has to be kept below the manufacturer s specifications for successful implementation of the flameless venting technology. Additionally, it is critical to regularly clean 6 the mesh layer in order to ensure that it is free of dust accumulation or dirt on its surface at all times, which otherwise may block the mesh openings and compromise the operation of the flameless vent. Low inertia, fire resistant fabric covers are available by some vent manufacturers to help keep flameless vents free of dirt. Picture 3 Flameless Vent According to NFPA 654, vented equipment needs to be isolated in order to prevent flame propagation between connected vessels. Further information on isolation methods is provided in the following sections of this paper. Rev 110810 Page 2

Picture 4 Flameless vent protecting an indoor receiver Explosion Suppression. As a well proven technology, explosion suppression systems have been employed in the industry since late 1950s. It is often used where it is not possible to vent the contents of process equipment to a safe place, and where the material being handled is toxic or is a harmful material to people and environment. Deflagration suppression requires that the incipient explosion be detected very soon after ignition, and a sufficient amount of suppressant is discharged into the developing fire ball in the enclosure at a fast enough rate to extinguish all flame before a destructive overpressure develops 7. Figure 1 below shows the basic steps in deflagration suppression. In the US, NFPA 69 8 governs the standards on explosion protection systems. Figure 1 Steps in explosion suppression 9 Rev 110810 Page 3

Picture 5 Explosion Suppressor Picture 6 Explosion protection (suppression and isolation) of an indoor dust collector Explosion Isolation. Very often process equipment handling particulate solids are connected to each other by ductwork, chutes and conveyors. A deflagration in a vessel can propagate through these connections to upstream or downstream equipment and cause subsequent explosions in the adjacent equipment. Explosion isolation systems are employed to mitigate the flame propagation and pressure piling between connected equipment. The objective of explosion isolation is to prevent dust explosions from spreading from the primary explosion site to other interconnected processes 10. According to NFPA 654 Section 7.1.4, where an explosion hazard exists, isolation devices shall be provided to prevent deflagration propagation between pieces of equipment connected by duct work 11. Some of the commonly used explosion isolation systems are: 1. Chemical isolation. It is achieved by rapid discharge of a chemical extinguishing agent (e.g. sodium bicarbonate) into interconnecting duct to mitigate flame propagation. Rev 110810 Page 4

Picture 7 Chemical isolation of a duct using a high rate discharge suppressor 2. Mechanical Isolation. High-speed gate valves and flow-actuated valves are some of the examples of mechanical isolation products. Active isolation devices such as high speed gate valves close in milliseconds upon detecting an explosion, and mitigate flame and pressure propagation inside ductwork by rapidly deploying a mechanical barrier 12. Passive isolation devices, such as flap or float type valves are self actuated by the air-flow created by deflagration event, thus require no detection or control components. Passive isolation devices are typically used to isolate nuisance dust handling equipment with relatively low dust loads. Picture 8A High-speed isolation gate valve Rev 110810 Page 5

Picture 8B Flap-type passive isolation valve (shown with maintenance hatch opened) Picture 9 Flap type valve isolating the inlet of a vented dust collector Explosion Protection System Selection 13 Considering the large number of explosion protection options available, we developed the following selection guide to illustrate the commonly employed explosion protection options for process owners. Throughout this paper it is assumed that the process owner has already performed a risk assessment, and determined that an explosion protection system is required as one of the means to mitigate combustible dust hazards. Thus our focus in this paper is limited to explosion venting, suppression and isolation. 1) Vented Dust Collector with Flap Type Passive Inlet Isolation This is one of the most cost effective protection options, utilizing a complete passive protection method. In this case, dust collector is located outside, and does not handle any toxic or other harmful materials. Due to valve s design limits, the K ST 14 of the dust is limited to maximum 300 bar.m/sec, the inlet duct diameter is maximum 22 inches, and the maximum reduced pressure 15 (P RED ) is limited to 7 psi. There will be flame and material release due to opening of the venting device during a deflagration event. The periodic maintenance of this system can be done by the system owner. This protection scheme meets NFPA 68, 69 and 654 requirements. Rev 110810 Page 6

2) Flameless Vented Dust Collector with Flap Type Passive Inlet Isolation In this case dust collector is located indoors, and it does not handle any toxic or other harmful materials. There is sufficient space around the vent area to allow 5 meters of safety perimeter. Due to flameless vent s design limits the maximum allowable K ST of the dust is 250 bar.m/sec. And due to flap valve s design limits, the inlet duct diameter is maximum 22 inches, and the maximum reduced pressure (P RED ) is limited to 7 psig. The isolation distance is up to 4 meters from the protected vessel. There will be no flame release however some hot-gas will release due to opening of the venting device during deflagration. The periodic maintenance of this system can be done by the system owner. This protection scheme meets NFPA 68, 69 and 654 requirements. 3) Vented Dust Collector with Chemical Inlet Isolation In this case, dust collector is located outdoors, and it does not handle any toxic or other harmful materials. There is no restriction on the size of inlet duct diameter. The maximum reduced pressure (P RED ) can be higher than 7 psi. The maximum allowable K ST for this system is 500 bar.m/sec. There will be flame and material release due to opening of the venting device during Rev 110810 Page 7

deflagration. The periodic maintenance of this system can be done by manufacturer or by manufacturer trained system owner. This protection scheme meets NFPA 68, 69 and 654 requirements. 4) Suppressed Dust Collector with Chemical Inlet Isolation In this case, dust collector can be located indoors or outdoors. There is no restriction on the type of material being handled. Also there is no restriction on the size of inlet duct diameter. The maximum reduced pressure (P RED ) of the vessel can be higher than 7 psi. The maximum allowable K ST for this system is 500 bar.m/sec. There will be no flame or material release after actuation of the system during a deflagration event. The periodic maintenance of this system can be done by the manufacturer or by manufacturer trained system owner. This protection scheme meets NFPA 69 and 654 requirements. 5) Suppressed Dust Collector with Chemical Inlet and Outlet Isolation In this case, dust collector can be located indoors or outdoors. However the clean-air exhaust is re-circulated back into the building. There is no restriction on the type of material being handled. There is no restriction on the size of inlet or outlet duct diameter. The maximum reduced pressure (P RED ) of the vessel can be higher than 7 psi. The maximum allowable K ST for this system is 500 bar.m/sec. There will be no flame or material release after actuation of the system during a deflagration event. The periodic maintenance of this system can be done by the manufacturer or by manufacturer trained system owner. This protection scheme meets NFPA 69 and 654 requirements. Rev 110810 Page 8

Returned to building 6) Suppressed Dust Collector with Chemical Inlet and Outlet Isolation for Hybrid Material Applications This is a case commonly seen in pharmaceutical or specialty chemical process applications. Dust collector can be located indoors or outdoors. There is no restriction on the type of material being handled. However the material is a mixture of flammable vapor/gas and combustible dust. There is no restriction on the size of inlet or outlet duct diameter. The maximum reduced pressure (P RED ) of the vessel can be higher than 7 psi. The maximum allowable K ST for this system is 500 bar.m/sec. There will be no flame or material release after actuation of the system during a deflagration event. The periodic maintenance of this system can be done by manufacturer or by manufacturer trained system owner. This protection scheme meets NFPA 69 and 654 requirements. Rev 110810 Page 9

Final Thoughts This paper provides a brief introduction to the commonly employed explosion protection technologies and illustrates the system selection process. Using the process provided in this paper, process engineer or risk manager can make informed decision on their explosion protection requirements. However it is important to note that selection of explosion protection system is application specific, and system design expertise is required to select and size the most appropriate system. The number and size of suppressors, their installation locations and explosion detector settings should only be determined by the application engineer of the system manufacturer using computer aided design methods specific to the system being considered. Thus contact your explosion suppression system supplier for more information on the products and system design criteria. REFERENCES 1 Ergun E., Advancements in Explosion Suppression System Product Safety, Reliability & Performance, American Institute of Chemical Engineers, 41st Annual Loss Prevention Symposium, April 8, 2008 2 OSHA Combustible Dust National Emphasis Program (Reissued), Directive No. CPL 03-00-008 3 U.S. CHEMICAL SAFETY AND HAZARD INVESTIGATION BOARD, COMBUSTIBLE DUST HAZARD STUDY, REPORT NO. 2006-H-1, November 2006 4 U.S. CHEMICAL SAFETY AND HAZARD INVESTIGATION BOARD, INVESTIGATION REPORT SUGAR DUST EXPLOSION AND FIRE, Report No. 2008-05-I-GA, September 2009 5 NFPA 68 Standard on Explosion Protection by Deflagration Venting, 2007 Edition 6 Explosion Protection using Flameless Venting A Review, Health & Safety Laboratory UK, Report No. HSL/2006/105 7 Guidelines for Safe Handling of Powders and Bulk Solids, 2005 Edition, AICHE CCPS 8 NFPA 69 Standard on Explosion Prevention Systems, 2008 Edition 9 http://www.incom-ag.ch/utcfs/ws-998/assets/explosion%20protection_e.pdf 10 Eckhoff, R. K., Status and Trends in Dust Explosion Prevention and Control, Fire & Safety Magazine, Spring 2008 11 NFPA 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Dusts, 2006 Edition. 12 Siwek, R., Explosion Protection Systems Classification and Design 13 A Tri-fold brochure illustrating the explosion protection options is available at www.fenwalprotection.com 14 K ST is the deflagration index of a dust, and is a measure of the relative explosivity of the material 15 P RED is the maximum pressure developed in a protected enclosure during a vented or suppressed deflagration. Rev 110810 Page 10