TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Similar documents
Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

VENTED CYLINDER RANGE

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

TORRENT ECO INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

Torrent GreenHeat. Design, Installation & Servicing Instructions. Open vented thermal store providing heating and mains pressure hot water

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

TORRENT ECO INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Amptec. Electric flow boiler

THERMflow Thermal Store Cylinders

THERMAL STORE MAINS PRESSURE SYSTEM

Torrent Stainless. Design, Installation & Servicing Instructions. Open vented stainless steel thermal providing both heating and hot water

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Efficiency Maximiser for Solid Fuel Central Heating

THERMAL STORE MAINS PRESSURE SYSTEM

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

ADVANCE ECB ELECTRIC COMBINATION BOILER

Kills bills. How Vaillant technologies reduce home heating bills

CUBEflow Thermal Store Tank

Risk Assessment and Control Measures for Household Hot Water Systems

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

ROTEX Sanicube: Combination of Hot water storage tank and Instantaneous heater. ROTEX Sanicube - The hygienic hot water storage tank. The heating!

2015 PRODUCT RANGE GUIDE

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

INTERCYL. INTERNAL EXPANSION EXCELLENCE

ADVANCE ELECTRIC THERMAL STORE

Exceeding the Standard

the electric heating company ELECTRIC BOILER HANDBOOK

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

EFFICIENCY THERMAL STORAGE SYSTEMS

EFG ENERGY OPTIMISING SYSTEMS

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

A Hot water revolution

BOILERMATE A CLASS OV

Link-Up. Solid Fuel Association Guide to Central Heating.

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

The Ultimate Solution for Electric Central Heating. Fusion. Comet

BOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers

For latest prices and delivery to your door visit MyTub Ltd

CPC-150-ABIAB. Important Installation Notes.

Exceeding the Standard

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

SOLAR HEATING SYSTEMS

JASPI GTV & Oval thermal storage

A new age in HEATING. Storage tank. ROTEX Sanicube The natural way to save energy! The complete heating system

Cistern-fed water heating

water solar heating SOLAR

Combined electric boiler and domestic hot water store

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

systemate 2000 fully integrated thermal store

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

PULSACOIL A CLASS USER GUIDE. TEL:

Total Hot Water Solutions

Electronic Dual Cylinder Thermostat User Instructions

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

High Output Boiler Systems

BOILERMATE A CLASS SP

Performance on demand

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Samsung EHS Heat Pump Test

Jaspi GTV and Jaspi Oval. Jaspi Oval thermal storage tanks

Combi Konverter Solar System

Multipoint Technical Data

PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS

Torrent MultiFuelStore HP

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Appendix T: Improvement measures for Energy Performance Certificates

Compact HRE Boiler Range. The smart choice for heating and hot water

Appendix T: Improvement measures

AN ENERGY SAVING ADDITIVE FOR CENTRAL HEATING SYSTEMS

StainlessLite HP. Design, Installation & Servicing Instructions. Unvented cylinders specifically designed to work with a heat pump

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

PULSACOIL 2000 USER GUIDE. TEL:

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Saving energy comes naturally to us.

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Section 7 F/602/2884 Understand and apply domestic hot water system installation and maintenance techniques

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

Gas Condensing Boilers

Where gas is not an option,

A HOT WATER REVOLUTION

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Transcription:

TORRENT ECO OPEN VENTED THERMAL STORE PROVIDING HEATING AND ONE NAME. EVERY SOLUTION. WWW.GLEDHILL.NET

WHAT IS A THERMAL STORE? A THERMAL STORE IS THE PERFECT SOLUTION FOR A HOME S HEATING AND REQUIREMENTS. TORRENT OFFERS MORE OPTIONS THAN ANY OTHER STORE OR CYLINDER, AND IS DESIGNED TO REDUCE HEATING COSTS BY OFFERING COMPLETE FLEXIBILITY FOR HOUSEHOLDERS TO USE MULTIPLE ENERGY SOURCES. The hot water within the store circulates around the heating system to heat the property, while mains cold water is instantaneously heated through a plate heat exchanger, to provide hot water. All our Torrent models are open vented, enabling uncontrolled heat sources such as woodburning stoves to be used. BENEFITS OF THERMAL STORES PROVIDE USE FOR BOTH HEATING AND NO ANNUAL MAINTENANCE OR SAFETY CHECK REQUIREMENT NO DISCHARGE PIPEWORK NO RISK OF LEGIONELLA NO G QUALIFICATION REQUIREMENT CONTENTS 0. WHAT IS A THERMAL STORE? 0. TORRENT ECO 0. WHICH PRODUCT DO I NEED? 0. TORRENT ECO OV 08. TORRENT ECO SP. TORRENT ECO SOL.. 0 0

TORRENT ECO THE TORRENT ECO IS MANUFACTURED FROM COPPER, BY OUR TRAINED COPPERSMITHS, WITHIN GLEDHILL S EIGHT NATIONWIDE MANUFACTURING DEPOTS. This provides the flexibility for homeowners to select the thermal store which best suits their requirements, allowing them to maximise the available heat sources, whether they are traditional boilers, electric immersions, or increasingly popular alternative energy fuel sources. The cylinder is open vented, enabling uncontrolled heat sources such as woodburning stoves to be used. WHICH PRODUCT DO I NEED? OUR SELECTION CHART BELOW WILL HELP YOU IDENTIFY THE MOST SUITABLE TORRENT ECO MODEL FOR YOUR INSTALLATION. To use the chart, identify the available heat sources for your cylinder in each section, and follow the lines to identify the model required. The option to add solid fuel tappings to utilise wood burning stoves or biomass boilers is available on the full range of Torrent ECO products. DOES THE SITE HAVE: ELECTRIC HEAT SOURCE? GAS/OIL BOILER? SOLAR THERMAL? HEAT PUMP? TORRENT ECO OV SOL FLOW SENSOR PROVIDES A FAST RESPONSE TIME FOR SUPPLY INTEGRATED PCB AND SOFTWARE HIGH STORE TEMPERATURES CAN BE UTILISED, PROVIDING GREATER BENEFIT FROM SOLID FUEL INPUTS ENERGY SAVING WITH A HIGH EFFICIENCY PUMP START HERE TORRENT ECO SP (SEALED PRIMARY BOILER) TORRENT ECO OV (OPEN VENTED BOILER) TORRENT ECO OV SOL (OPTIONAL SP COIL) TORRENT ECO OV TORRENT ECO OV SOL TORRENT ECO SP (SEALED PRIMARY BOILER) TORRENT ECO OV (OPEN VENTED BOILER) TORRENT ECO OV SOL (OPTIONAL SP COIL) Underfloor tappings optional through the full range. All models come complete with back up immersion. Where a Torrent ECO SP is used, heating should be provided directly by the boiler as the store will only provide auxiliary heating. 0 0

TORRENT ECO OV 0 0 0 LITRES TORRENT ECO OV SHOWING HOW THE CENTRAL HEATING SUPPLIED FROM STORE 1 Utilises open vented boiler to heat the store directly kw immersion heater for emergency back-up Electric only versions available Optional solid fuel connections UNDERFLOOR HEATING SUPPLIED FROM STORE TORRENT ECO OV Description TEC0-OV TEC-OV TEC-OV TEC0-OV TEC0-OV ErP rating C C C C C Immersion heater Solid fuel flow (optional) Boiler flow OV Central heating flow Control thermostat 8 Immersion heater 9 Central heating Open vented boiler Domestic hot water Plate heat exchanger flow Hot supply Cold mains Cold feed 1 Solid fuel (optional) 1 Plate heat exchanger 18 Drain Heat loss watts 8 81 9 Capacity litres 1 01 9 Unit height mm 19 9 1 18 Unit diameter mm 8 8 Max. hot water flow rate litres/minute bath 1 1 shower room - 1 1 bed 1 - - - - - 9 8 0 1 18 1 Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. The standard open vented store relies on a feed and expansion tank suitably sited above the highest radiator point to provide sufficient head for the system. 0

TORRENT ECO SP 0 0 0 LITRES TORRENT ECO SP SHOWING HOW THE AUXILIARY CENTRAL HEATING SUPPLIED FROM STORE LIMITED TO HEAT INPUT PROVIDED BY AUXILIARY HEAT SOURCE 1 Utilises a sealed primary boiler to heat the store indirectly via an internal coil Auxiliary or underfloor heating available directly from the store (subject to heat input) kw immersion heater for emergency back-up UNDERFLOOR HEATING SUPPLIED FROM STORE CENTRAL HEATING SUPPLIED BY BOILER Optional solid fuel connections SEALED SYSTEM KIT TORRENT ECO SP Description TEC0-SP TEC-SP TEC-SP TEC0-SP TEC0-SP Solid fuel flow (optional) Central heating flow (optional) Immersion heater Control thermostat Sealed primary boiler flow 8 Sealed primary boiler 9 Central heating (optional) Domestic hot water Plate heat exchanger flow Hot supply Cold mains Cold feed Solid fuel (optional) 1 Plate heat exchanger 1 Drain ErP rating C C C C C Heat loss watts 8 81 9 Capacity litres 1 01 9 Unit height mm 19 9 1 18 Unit diameter mm 8 8 Max. hot water flow rate litres/minute bath 1 1 shower room - 1 1 bed 1 - - - - - 9 8 1 1 08 Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. 09

TORRENT ECO SOL 0 0 LITRES 1 Specifically designed for use with solar thermal panels TORRENT ECO SOLAR SHOWING HOW THE IF USING AN SP BOILER, THE AUXILIARY CENTRAL HEATING SUPPLIED FROM THE STORE IS LIMITED TO THE HEAT INPUT PROVIDED BY THE AUXILIARY HEAT SOURCE Utilises open vented boiler to heat the store directly Optional sealed primary boiler connections UNDERFLOOR HEATING SUPPLIED FROM STORE 1 kw immersion heater for emergency back-up Optional solid fuel connections EITHER AN OPEN VENTED, SEALED PRIMARY OR A COMBINATION OF THE TWO BOILERS CAN BE USED SEALED BOILER SEALED SYSTEM KIT CENTRAL HEATING SUPPLIED BY BOILER TORRENT ECO SOL 8 9 1 0 18 19 Open vented boiler flow Central heating flow Sealed primary boiler flow (optional) Sealed primary boiler (optional) Central heating 8 Open vented boiler 9 Solid fuel (optional) Solar coil flow Solar sensor Solar coil Domestic hot water Plate heat exchanger flow Solar sensor 1 Solid fuel flow (optional) 1 Control thermostat 18 Hot supply 19 Cold mains 0 Immersion heater 1 Cold feed Solid fuel (optional) Plate heat exchanger Drain Description TEC -SOL TEC0-SOL TEC0-SOL ErP rating C C C Heat loss watts 81 9 Capacity litres 01 9 Unit height mm 1 18 Unit diameter mm 8 8 Dedicated solar volume litres 1 Max. solar collector area 1 m..91.0 Solar heat exch. surface area 1 m 0. 0. 0.0 Max. hot water flow rate litres/minute bath 1 1 shower room 1 bed - - - 1 1 To comply with the Building Regulations ADL1 Domestic Heating Compliance Guide. This can be adjusted at the time of specification. Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. The standard open vented store relies on a feed and expansion tank suitably sited above the highest radiator point to provide sufficient head for the system. As the domestic hot water is at mains pressure, the Torrent ECO Solar itself can be sited anywhere in the property. Provision is also made within the design for a sealed heating/boiler circuit with the heat exchanger provided which would then operate as a conventional cylinder. Although this would reduce the potential for utilising the solar energy in the HEATING CIRCUIT, it would mean that both the Torrent and the feed and expansion tank can then be sited anywhere in the property, as the feed and expansion is only being used to fill the store with water.

1 0 0 LITRES Specifically designed for use with either air source or ground source heat pumps Heating provided directly from the store Optional solid fuel connections kw immersion heaters for boost and emergency back-up for both heating and hot water SHOWING HOW THE CENTRAL HEATING SUPPLIED FROM STORE Description TEC-HP TEC-HP TEC0-HP TEC0-HP ErP rating C C C C 1 1 Solid fuel flow (optional) Heat pump cylinder sensor Control thermostat Heat pump flow Central heating flow 8 Central heating immersion 9 Central heating Heat pump sensor Heat pump Domestic hot water Plate heat exchanger flow Hot supply Cold mains 1 Domestic hot water immersion heater 1 Heat pump flow sensor 18 Cold feed 19 Solid fuel (optional) 0 Plate heat exchanger 1 Drain Heat loss watts 8 81 9 Capacity litres 1 01 9 Unit height mm 9 1 18 Unit diameter mm 8 8 Max. hot water flow rate litres/minute bath 1 1 shower room 1 1 bed - - - - 8 18 9 19 0 1 The suggested model sizes in the selection chart are based on a store temperature of C. If the intention is that the heat pump will be used to provide the majority of the hot water with minimum boost from another heat source then consideration should be given to choosing a larger model of Torrent ECO HP appliance. See the design installation and servicing instructions for equivalent volumes at different charge temperatures. If the immersion heater is to be used as the hot water boost a suitable control system should be installed to ensure that the heat pump has fully charged the appliance before the boost immersion heater is allowed to operate. This will ensure the most efficient and cost effective use of the system.

1 0 0 LITRES Specifically designed to combine solar thermal and heat pump technology SHOWING HOW THE Heating provided directly from the store Optional solid fuel connections to provide the ultimate alternative energy cylinder CENTRAL HEATING SUPPLIED FROM STORE kw immersion heaters for boost and emergency back-up for both heating and hot water 8 9 18 1 1 1 0 19 Solid fuel flow (optional) Heat pump cylinder sensor Control thermostat Heat pump flow Central heating flow 8 Central heating 9 Heat pump sensor Heat pump Solar coil flow Solar coil Domestic hot water Plate heat exchanger flow Solar sensor 1 Hot supply 1 Domestic hot water immersion heater 18 Heat pump flow sensor 19 Cold mains 0 Central heating immersion heater 1 Solid fuel (optional) Solar sensor Cold feed Solid fuel (optional) Plate heat exchanger Drain Description TEC-HPSOL TEC0-HPSOL TEC0-HPSOL ErP rating C C C Heat loss watts 81 9 Capacity litres 01 9 Unit height mm 1 18 Unit diameter mm 8 8 Dedicated solar volume litres 1 Max. solar collector area 1 m..91.0 Solar heat exch. surface area 1 m 0. 0. 0.0 Max. hot water flow rate litres/minute bath 1 1 shower room 1 1 bed - - - 1 To comply with the Building Regulations ADL1 Domestic Heating Compliance Guide This can be adjusted at the time of specification. The suggested model sizes in the selection chart are based on a store temperature of C. If the intention is that the heat pump will be used to provide the majority of the hot water with minimum boost from another heat source then consideration should be given to choosing a larger model of Torrent ECO HP SOL appliance. See table 1b in the design installation and servicing instructions for equivalent volumes at different charge temperatures. If the immersion heater is to be used as the hot water boost a suitable control system should be installed to ensure that the heat pump has fully charged the appliance before the boost immersion heater is allowed to operate. This will ensure the most efficient and cost effective use of the system.

SPARES Gledhill cylinders are manufactured to the highest quality standards. In the unlikely event that you require a spare part, you can contact Gledhill Spare Parts, on: 0 or visit www.gledhill-spares.net HERE TO HELP If you re looking for technical assistance while you re on the job, give our technical team a call. With many years experience, they re an invaluable resource to have at the end of the phone. FOR ADVICE PLEASE CALL 0 8 Gledhill Building Products Limited Sycamore Estate, Squires Gate, Blackpool FY RL T: 0 0 E: enquiries@gledhill.net GBP.1 WWW.GLEDHILL.NET Due to a programme of continuous improvement Gledhill Building Products reserves the right to modify products without prior notice. It is advisable to check the product technical detail by using the latest design and installation manuals available from our technical support team or on our website. It is an offence to copy or adapt this document without consent of the owner.