Alarm Tone Generator Model AG17

Similar documents
Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Explosion Proof Line Powered Telephone Ringer

Hazardous Area Ringdown Telephone

Hazardous Area Telephone Model EP600

Merge/Isolate Zone Control System

Model SS2000C31 SmartSystem Load Management System

STATUS ALARM HISTORY ALARM RESET

Mark 25 Ultrapure Water Conductivity Analyzer

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

INSTALLATION AND INSTRUCTION MANUAL

Model SS2000SM Series ELECTRONIC SIREN/LIGHT CONTROL SYSTEM WITH SignalMaster DIRECTIONAL LIGHT (with Slide Switch Control Head)

Instruction Manual Model L2 RF Switch

Multi-Graphic MCPB & Series 115B, 2223R, & 2233R

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

6502B RF Distribution

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

4 & 8-POINT ANNUNCIATORS Instruction Manual

Intelligent Line Module

380 SERIES REMOTE SIREN ETSA380R

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Controllers. Instruction Manual WARNING

C2 Compact Range Installation & Programming Manual

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

SCORPION Z16040C, Z8040C and Z5120C

Bench Top Ionizer Installation, Operation and Maintenance

Pre-Installation Requirements:

Emergency/Help Point Analog Telephones & Correctional Analog Telephones

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

Version 1.03 January-2002 USER S MANUAL

INSTALLATION INSTRUCTIONS

Installation Instructions for W2H Series Signals

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

DNA-510. Add Emergency Mass Notification Messages and Alert Tones to your Existing Paging System. Features. Applications

Model 1062 Environment Monitor

Auto Dialer. Manual E-921APQ E-921GPQ

Typhoon Full Function C-4017

Instruction Manual WARNING

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

640 Series Advanced Remote Vehicle Security System

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model SS2000SS Series ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM (with Slide Switch Control Head)

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Series: MBC1-TC Mini Benchtop Temperature Controller

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Static Pressure Control

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

Solution 880 Operators Manual. Issue 1.00

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Emerald 3000 MK3 GJD010 Lighting Controller

Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Emergency, Correctional & Institutional

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

Installation & Operation Manual March 2017 Rev. 4.1

INSTRUCTIONS MANUAL. 1.8L Electric Kettle with Multi-Temp Feature SK-1800R (Red) SK-1800SS (Stainless Steel)

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

EVO192 v3.0 Fire and Burglary What s New

Instruction Manual Model Backup Switch, 1 for 8

Model RC-10 INSTRUCTION MANUAL

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

RELEASE DEVICE CONTROLS

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Installation and ZONES: Operation Manual. Model: ON STI-34108

MODEL B2 INSTALLATION MANUAL

Typhoon Full Function C-4017

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Global Water Instrumentation, Inc.

TECHNICAL DNA-510. Add Emergency Mass Notification Messages and Alert Tones to your Existing Paging System. Digital Mass Notification Announcer

ACCURATE ELECTRONICS INC

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

July 14, 1999 DF C-100.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

Panel Mounted Heat Exchangers by Dantherm, Inc.

TECHNICAL. Add Time Controlled Alert Tones and Emergency Tones to Your Paging System CTG-1. Clock Controlled Tone Generator

Automatic Phone-Out Home Monitoring Systems

SA SIREN AMPLIFIER

RangerNET Network Ready Constant Monitor Model CM2815

VAS12SUB / VAS15SUB VAS18SUB SHAKER SUBWOOFER SYSTEMS

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

TrueAlarm Fire Alarm Controls

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

INSTRUCTION MANUAL P Heating and 1 Cooling

Transcription:

Alarm Tone Generator Installation & Operation P005089 Rev. C 150930 9/30/2015 12:25 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com

Table of Contents Package Contents... 2 Overview... 3 AG17 Tone Generator Models... 3 Features... 3 Front Panel... 4 Rear Panel... 5 Installing the AG17... 7 Unit Operation... 8 Default Settings... 8 Alarm Logic Inputs... 8 Alarm Logic Outputs... 9 Override Audio / Logic Inputs... 10 Audio / Logic Outputs... 10 Input Volume Control... 10 Output Volume Control... 10 Clear / Reset Terminals... 10 Clear / Reset Switches (Front Panel) Local... 10 Clear / Reset Terminals (Rear Panel) Remote... 10 Relay Contacts (Optional)... 10 Programming the AG17... 11 Setting Input Channel Alarm Tones... 11 Setting Triggering and Attenuation... 12 Setting the Timer for Pulse-Triggered Logic Inputs... 13 Setting the All Clear Tone... 13 Interpreting the LED Display Pattern Table... 13 Displaying All Parameters Stored In Non-Volatile RAM... 14 Product Specifications... 15 Warranty... 17 Disclaimer... 17 Warning... 17 Service Telephone Number... 17 1-800-363-8010... 17 Feedback... 17 Guardian Product Return... 18 Table of Figures Figure 1 - Front Panel...4 Figure 2 - Rear Panel...5 Figure 3 - Typical Installation...6 One AG17 Tone Generator One Manual Package Contents Page 2

Overview Alarm Tone Generator The Guardian Telecom AG17 is a state-of-the-art signal generator with a ten-tone signal library designed to work with general alarm and public address systems. Alarm tone, priority, duration and triggering are programmable to meet specific operating and workplace conditions. Installation is simple. An audio override facility also allows voice-paging announcements. The AG17 Tone Generator is one component in Guardian Telecom's full line of paging system products, which include amplifiers and signal and switch conditioning equipment. Model P5970 AG17 AG17 Tone Generator Models Model P5960 AG17 with optional relay board. Features Programmable 10 tone alarm library user programmable microprocessor to customize tone priority, duration, triggering, muting and attenuation eight channels for output signal priority logic outputs that mirrors control input momentary or latching inputs LED alarm activation indicators output level control Compact fits on a standard 19" equipment rack, requiring only 2 rack units (2U) Audio Override for page/talk announcements Page 3

Front Panel LED Indicators, Clear and Reset Switches 1. Power LED Illuminates when the unit is on. 2. Alarm LEDs Illuminates when the alarm is active. 3. Clear Switch Activates the 3-Beep Clear tone. 4. Reset Switch Turns off the highest priority tone active. Figure 1 - Front Panel Page 4

Rear Panel The rear panel of the AG17 is where all the connections are made. 1. Clear/Reset Terminals Connect Clear and Reset switches. 2. Alarm Logic Outputs Trigger external devices. 3. Audio / Logic Output Connect external devices. 4. Output Volume Control Adjusts overall audio output level of the AG17. 5. Input Volume Control Adjusts input level of the Override Audio Signal. 6. Override Audio / Logic Input Overrides tones when the logic signal is present. 7. Programming Jack Connects a DTMF tone generating analog telephone for programming the AG17. 8. Alarm Logic Inputs Activate any of 8 available alarm tones. 9. Relay Contacts (Optional) Trigger external devices. 10. Fuse Fuse replacement with 1/2A, 3AG, 250V fast blow fuse only. 11. Power On/Off Switches unit on or off. POWER CLEAR RESET ALARM RELAY CONTACTS 1 2 3 4 5 6 7 8 RELAY CONTACTS A NORMALLY OPEN B COMMON C NORMALLY CLOSED A B C A B C A B C A B C A B C A B C A B C A B C OUTPUT VOLUME INPUT ALARM LOGIC OUT A L O/P I/P A L ALARM LOGIC IN INPUT / OUTPUT F U S E + - + - GUARDIAN TELECOM INC. CALGARY, ALBERTA, CANADA 1 2 3 4 5 6 7 8 C C + - + - + - + - 1 2 3 4 5 6 7 8 C C A L AUDIO LOGIC F US E FUSE 1/2A 120VAC Figure 2 - Rear Panel Page 5

AG-17 Alarm Tone Generator POWER CLEAR RESET + - + - GUARDIAN TELECOM INC. CALGARY, ALBERTA, CANADA 1 A B C ALARM LOGIC OUT OUTPUT A L 1 2 3 4 5 6 7 8 C C + - + - ALARM RELAY CONTACTS 2 3 4 5 6 A B C A B C A B C A VOLUME O/P I/P INPUT A L + - + - B C A B C 7 8 A B C A B C ALARM LOGIC IN 1 2 3 4 5 6 7 8 C C A B C RELAY CONTACTS NORMALLY OPEN COMMON NORMALLY CLOSED INPUT / OUTPUT A L AUDIO LOGIC F US E F U S E FUSE 1/2A 120VAC Audio Pair Logic Pair Alarm Activation Manual Push Button Fire & Gas Alarm System Push to Talk Button (Logic) Input Output Power Amplifier 70/100V Paging Line Power - Supply + Relay Paging Speakers Strobe Lights 120V AC Neu. Figure 3 - Typical Installation Page 6

Installing the AG17 Carefully plan input and output connections. Identify input and output devices. Tip: Familiarize yourself with unit capabilities and functions. See: Typical Installation drawing and Unit Operation details. Prioritize alarm inputs. Tip: Input #1 is the highest priority. Plan output connections to correspond with input priorities. Follow all appropriate electrical codes for the installation. Inspect the product for shipping damage. Tip: If the product is damaged, notify the carrier immediately. Do not open or attempt to open the AG17 unit. There are no user serviceable parts inside the unit. Choose a location on a standard 19" equipment rack with 2 rack units (2U) of available space. Have a standard touch-tone telephone available to program the AG17 after installation is complete. Secure the unit to the rack. Ensure all devices that will be connected to the AG17 are turned off. Plug the AG17 into the power source but do not apply power to the AG17 before connecting input and output devices. Tip: Unauthorized modifications void the product warranty. See: Programming, below. Use the following sequence when wiring connections: See: Unit Operation for more details. Alarm Logic Input Alarm Logic Output Clear/Reset (optional) Input Audio/Logic Output Audio/Logic Alarm Relay Contacts (optional) See: Unit Operation for wiring caution on Logic Output. Page 7

Refer to your individual input/output/priority plan and wire all required connections as follows: Remove quick disconnect connector (Phoenix Combi-Con). Wire the connector. Plug the connector back into the unit. When connections are complete, apply power to the AG17. The AG17 operates with default settings as soon as power is applied. If customized settings are required, program the AG17 using a touch-tone telephone. Apply power to all input devices. See: Unit Operation and Programming the AG17, below. Default Settings Pulse-Trigger Logic Input 60 db Attenuated Tones All Clear Tone Enabled Timer Reset Disabled Channel 1 - Beep, High Channel 2 - High / Low Channel 3 - Warble Channel 4 - Yelp, Fast Channel 5 - Whoop, Slow Channel 6 - Siren Channel 7 - Steady Channel 8 - Beep, Low Alarm Logic Inputs Unit Operation Logic Input Channels are used to connect devices (e.g., fire and gas detection systems) that activate alarm tones. The eight channels are arranged in priority as follows: Channel #1 is the highest priority. Channel #8 is the lowest priority. Each channel has an assigned default tone. See: Default Settings, above. Page 8

To assign a tone other than the default to any channel, program the unit. The input channel tone broadcasts when the channel is activated by a contact closure. If a higher priority input channel is already activated, the lower priority tone does not broadcast. Tip: There are 10 tones to choose from. See: Programming, Setting Input Channel Alarm Tones, below. To select either a level-triggering or positive edge pulse-triggering signal, program the unit. The AG17 is preset for a Pulse-Trigger Logic Input default. Lower priority triggered channels are suppressed until higher priority channels are released. Front panel LEDs indicate all activated channels. Tip: The type of triggering selected is applied to all input channels. See: Programming, Setting Triggering and Attenuation, below. The alarm tone associated with the activated, highest priority channel is generated until the Timer or the Reset Switch resets it. The unit is preset with the Timer Reset disabled so tones continue to sound until the reset switch is pressed. To enable the Timer, program the unit. Timer duration on the AG17 can be programmed for tones operating from 30 seconds to 30 minutes. Pressing the Reset switch clears the highest priority activated channel. Tip: The Timer determines the length of time the alarm sounds before it automatically resets. See: Programming, Setting the Timer for Pulse Triggered Logic Inputs, below... Alarm Logic Outputs Logic Outputs are used to connect devices (e.g., strobe lights, relays) that trigger when an alarm is activated. Each Logic Output Channel is associated with the corresponding Logic Input Channel number. Tip: Each Logic Output Channel is an isolated open-drain circuit. Wire Logic Outputs according to standard Open-drain / Open-collector procedures. Do not apply positive DC voltage to the source terminal or hook-up AC voltage across the logic terminals. Note: The maximum rating for each logic output is 300 ma at 40 V DC. Caution: Applying positive DC voltage to the source terminal or AC voltage across the source/drain terminals will damage the AG17. Page 9

Override Audio / Logic Inputs Override Audio / Logic Inputs have a higher priority than alarm tone signals. A contact closure on the Override Audio / Logic Input suppresses any existing alarm tone and broadcasts the signal on the Override Audio Input. The AG17 is preset for 60 db attenuated alarm tones. To select attenuation, program the unit. The AG17 can be programmed so that the alarm tone is completely muted by the Override or attenuated by 10dB, 20dB, or 60dB. Audio / Logic Outputs The Audio output connects to devices such as paging amplifiers or other signal conditioning equipment. The Logic output can enable activation of amplifiers that employ a sleep condition to eliminate noise in a no signal present application. Input Volume Control Input Volume controls the Override Audio level. Override Audio level can be adjusted to the same level as the tones generated by the AG17. Output Volume Control Output Volume controls the Audio output of the AG17. The Audio Output level can be adjusted according to the input requirements of the external device (e.g., amplifier) being connected. Clear / Reset Terminals Pulse triggered alarms are reset by the reset feature. Level triggered alarms are reset by the removal of the level activation logic signal. Clear / Reset Switches (Front Panel) Local The Clear switch on the front panel activates a three-tone Clear Signal. The Reset switch on the front panel turns off the highest priority active alarm tone. Clear / Reset Terminals (Rear Panel) Remote Clear / Reset terminals are used to connect remote clear and reset devices. Clear activates a three-tone Clear Signal. Reset turns off the highest priority active alarm tone. Relay Contacts (Optional) The optional relay board provides eight relay contacts. Each relay contact is associated with an Input Channel. When an Input Channel is activated by contact closure, the associated relay activates and remains active until the alarm is reset. See: Programming, Setting Triggering and Attenuation, below. Tip: The Reset switch operates when the AG17 is in the Pulse Trigger mode. Page 10

Programming the AG17 Connect a DTMF tone-generating analog telephone to the RJ11 jack on the rear panel. Lift the telephone handset off the hook. Check to ensure the Power LED is illuminated. Check to ensure the front panel LED's are not illuminated. If a value is entered beyond the acceptable range during programming, all front panel LEDs blink once to alert the programmer. At any time during programming, you can check parameters to confirm programming accuracy. Follow the Setting Tables below and use the touch-tone telephone keys to program the AG17. When programming is complete, disconnect the telephone from the AG17. See: Programming, Displaying All Parameters Stored in Non-Volatile RAM, below. Setting Input Channel Alarm Tones Press the # key, then the Channel Number (1-8), then the Alarm Tone Number (0-9). # Input Channel Number 1-8 Alarm Tone 0-9 # 1 = Channel 1 1 = Siren # 2 = Channel 2 2 = Warble # 3 = Channel 3 3 = Yelp, Slow # 4 = Channel 4 4 = Yelp, Fast # 5 = Channel 5 5 = Whoop, Slow # 6 = Channel 6 6 = Whoop, Fast # 7 = Channel 7 7 = High/Low # 8 = Channel 8 8 = Steady 9 = Beep, Low 0 = Beep, High Page 11

Setting Triggering and Attenuation Press the # key, then the number 0, then the Triggering and Attenuation Number (1-9). # 0 Triggering and Attenuation 1-9 # 0 1 = Level triggered inputs 10dB Tone attenuation # 0 2 = Level triggered inputs 20dB Tone attenuation # 0 3 = Level triggered inputs 60dB Tone attenuation # 0 4 = Level triggered inputs Tone totally muted. # 0 5 = Pulse triggered inputs 10dB Tone attenuation # 0 6 = Pulse triggered inputs 20dB Tone attenuation # 0 7 = Pulse triggered inputs 60dB Tone attenuation # 0 8 = Pulse triggered inputs Tone totally muted # 0 9 = Default Settings Pulse trigger Inputs 60dB attenuated tones Page 12

Setting the Timer for Pulse-Triggered Logic Inputs Press the * key, then the Timer Duration Number (1-9). * Timer Duration 1-9 * 1 = 30 seconds * 2 = 1 minute * 3 = 2 minutes * 4 = 5 minutes * 5 = 10 minutes * 6 = 15 minutes * 7 = 20 minutes * 8 = 30 minutes * 9 = Timer Disabled - all tones continue to sound until reset. Setting the All Clear Tone Press the # key, then the number 9, then the Enable or Disable Number (1-2). # 9 1 = Enable # 9 2 = Disable Interpreting the LED Display Pattern Table After pressing the * and then the 0, four distinct pattern sequences will be observed. The LEDs will flash in 0.5 second intervals. 1. The first sequence will be the flashing of LEDs 1 4. Count the number of flashes and refer to Section 1, LED Input Triggering Mode and Attenuation for the selected operation. 2. The second sequence will step through the eight LEDs. Count the number of flashes on each led and refer to section 2 for the alarm tone that is programmed for that channel. 3. The third sequence is for All Clear Tone and LEDs 1 4 will flash if it is disabled and 5 8 will flash if activated as Section 3 indicates. 4. The final sequence involves only LED #1 for Flash Timer Correlation. Count the number of flashes and refer to Section 4 for the selected timing. Page 13

Displaying All Parameters Stored In Non-Volatile RAM Press the * key, then the number 0. See: LED Display Pattern Table. LED Display Pattern Table SEQUENCE #1 1 2 3 4 5 6 7 8 Input Triggering Mode and Attenuation On = LED Flashing ON ON ON ON X X X X 1 Flash Level 10dB X = LED Not Flashing ON ON ON ON X X X X 2 Flashes Level 20 db ON ON ON ON X X X X 3 Flashes Level 60 db ON ON ON ON X X X X 4 Flashes Level Mute ON ON ON ON X X X X 5 Flashes Pulse 10 db ON ON ON ON X X X X 6 Flashes Pulse 20 db ON ON ON ON X X X X 7 Flashes Pulse 60 db ON ON ON ON X X X X 8 Flashes Pulse Mute SEQUENCE #2 1 2 3 4 5 6 7 8 Flash/Tone Correlation (See Flash=Tone) ON X X X X X X X Channel 1-1-10 Flashes X ON X X X X X X Channel 2-1-10 Flashes X X ON X X X X X Channel 3-1-10 Flashes X X X ON X X X X Channel 4-1-10 Flashes X X X X ON X X X Channel 5-1-10 Flashes X X X X X ON X X Channel 6-1-10 Flashes X X X X X X ON X Channel 7-1-10 Flashes X X X X X X X ON Channel 8-1-10 Flashes Flash = Tone 1 Flash = Siren 2 Flashes = Warble 3 Flashes = Yelp, Slow 4 Flashes = Yelp, Fast 5 Flashes = Whoop Slow 6 Flashes = Whoop, Fast 7 Flashes = High/Low 8 Flashes = Steady 9 Flashes = Beep, Low 10 Flashes = Beep, High SEQUENCE #3 ON ON ON ON X X X X All Clear Tone Enabled X X X X ON ON ON ON All Clear Tone Disabled SEQUENCE #4 ON X X X X X X X Flash/Timer Correlation ON X X X X X X X 1 Flash = 30 Seconds ON X X X X X X X 2 Flashes = 1 Minute ON X X X X X X X 3 Flashes = 2 Minutes ON X X X X X X X 4 Flashes = 5 Minutes ON X X X X X X X 5 Flashes = 10 Minutes ON X X X X X X X 6 Flashes = 15 Minutes ON X X X X X X X 7 Flashes = 20 Minutes ON X X X X X X X 8 Flashes = 30 Minutes ON X X X X X X X 9 Flashes = Timer Reset Disable Page 14

Product Specifications ELECTRICAL REQUIREMENTS INPUT VOLTAGE INPUT FREQUENCY MAXIMUM CURRENT CONSUMPTION FUSE ALARM LOGIC INPUTS (8) ACTIVATING DEVICE MINIMUM OPEN COLLECTOR/ OPEN DRAIN OUTPUT 120VAC OR 240VAC AVAILABLE WITH FACTORY ORDER 50/60HZ 12VA 1/2A; 3AGC, 250VOLT, FAST-BLOW DRY CONTACT RELAY 5V @ 1mA MIN. OVERRIDE AUDIO INPUT INPUT IMPEDANCE CONTROL 600 OHMS @ 750VRMS MAX. INPUT VOLUME CONTROL POT OVERRIDE LOGIC INPUT ACTIVATING DEVICE MINIMUM OPEN COLLECTOR/ OPEN DRAIN OUTPUT ALARM LOGIC OUTPUTS (8) MAXIMUM OPEN DRAIN OUTPUT DRY CONTACT RELAY 5V @ 1 ma MIN. 300 ma @ 40VDC MAX AUDIO OUTPUT OUTPUT IMPEDANCE CONTROL AUDIO SIGNALS 33 OHMS @ 1VRMS MAX OUTPUT VOLUME CONTROL POT ALARM TONES TONE 1: SIREN 400 HZ - 1000 HZ, 0.3 SECONDS TONE 2: WARBLE 400 HZ - 1000 HZ, 0.3 SECONDS TONE 3: YELP, SLOW 400 HZ - 1000 HZ, 4.2 SECONDS TONE 4: YELP, FAST 400 HZ - 1000 HZ, 1.6 SECONDS TONE 5: WHOOP, SLOW 400 HZ - 1000 HZ, 4.2 SECONDS TONE 6: WHOOP, FAST; 400 HZ - 1000 HZ, 1.6 SECONDS TONE 7: HIGH / LOW 560 HZ - 760 HZ, 1.2 SECONDS TONE 8: STEADY 1000 HZ TONE 9: BEEP, LOW; 120 HZ, 1.2 SECONDS TONE 10: BEEP, HIGH 1000 HZ, 1.2 SECONDS CLEAR: 3 BEEP ALARM TONES ATTENUATED 1000 HZ 10 db, 20 db, 60 db, MUTED Page 15

OPTIONAL ALARM RELAY 8 OUTPUTS IN FORM C CONTACTS MAXIMUM OUTPUT CONTACT CAPACITY PROGRAMMING JACK VAC: 120 VAC @ 1 A MAX., VDC: 30 VDC @ 2 A MAX. RJ11C MECHANICAL BODY CONSTRUCTION BODY DIMENSIONS NET WEIGHT CONNECTION AUDIO CONNECTION LOGIC CONNECTION POWER MOUNTING MILD STEEL POWDER COATED 419 X 207 X 77 MM (16.5 X 8.2 X 3.1 IN.) 3.2KG (7 LBS.) REMOVABLE CONNECTION PLUG REMOVABLE CONNECTION PLUG 120VAC U GROUND POWER CORD STANDARD RACK MOUNTING (2 UNITS) Page 16

Warranty Guardian Telecom warrants your product to be free of defects in material and workmanship for a period of one year. Guardian Telecom will repair or replace any defective unit that is under warranty free of charge. This warranty is null and void if any non-authorized modifications have been made to this product, or if it has been subjected to misuse, neglect, or accident. This warranty covers bench repairs only; such repairs must be made at Guardian Telecom or an authorized service depot. Guardian Telecom is not responsible for costs incurred for on-site service calls, freight, or brokerage. A return authorization must be obtained prior to warranty claims or repairs. Disclaimer The products covered by this manual are designed for use in Industrial Environments and/or Hazardous Locations. Due to the range of possible applications for these instruments the manufacturer will not be responsible for damages or losses of any kind suffered as a result of the use of this product, including consequential damages. Warning This device may be opened and reassembled by qualified personnel only, for the purposes of installing the product, making adjustments and replacing components, following the instructions in the product manual. Before opening this telephone disconnect the wiring at the demarcation block. High voltages may be present in this product when connected to telephone wiring. Service Telephone Number 1-800-363-8010 Guardian Telecom provides a customer service telephone number which is toll-free within North America. If you need assistance when installing or operating this product, please call the toll-free telephone number between regular business hours (8:00AM-5:00PM), Mountain Standard Time. If you are calling outside of regular business hours, please leave a detailed message, and a member of Guardian Telecom s Service Department will return your call as soon as possible. If your product requires service, Guardian personnel will supply you with an RMA (return materials authorization) number over the telephone or through our web site product return page. This number must be included with your return address and the name of the person to contact. Guardian Telecom Inc. Toll-free 1-800-363-8010 Ph. (403) 258-3100 Fax. (403) 253-4967 www.guardiantelecom.com Feedback Guardian Telecom continually strives to make reliable, durable, and easy to use products. If you, as an installer or user of our equipment, have any suggestions for improvements to this or any of our products or documents, including this manual, we would appreciate hearing from you. Page 17

Guardian Product Return Guardian products have been quality tested and are in full working order when shipped from the factory, given the rugged nature of these products shipping is not expected to damage a unit. In the unlikely event of a malfunction Guardian follows the three step procedure below. Step I - On-Site Correction The most common source of difficulties with a new product is improper installation in one of two ways: incorrect wiring connections or connection to an incorrect power source. Product wiring needs to be properly connected to the on-site wiring. Correct wiring instructions are shown in the user manual included with the product. Step II - Return Materials Authorization (RMA) When a product has been installed following user manual instructions, and the unit fails to operate, the user must contact Guardian Telecom to obtain authorization to return the product. After providing information on the product, the owner and the nature of the problem, Guardian will issue a RMA number, to be shown on documentation returned with the product. In addition to the RMA number, shipping documents should include name, address and telephone number of the owner along with contact information for the person responsible for the repair and/or the user who identified the malfunction. (Where a product is being returned for repair from outside of Canada, customs documentation must show the product s serial number, date of export [date of purchase], and a notation that the equipment is: Canadian goods returning. ) Step III - Factory Authorized Service Once received, each product is carefully inspected and tested. If the product is under warranty, repairs are completed and the product returned to the owner, generally within five working days of receipt by the factory. A product that has been subjected to misuse, neglect or accident or is beyond the warranty period will be evaluated. The service department will provide the owner s representative with a repair cost estimate. Once approved, repairs are completed and the product returned, generally within five working days. Page 18

Notes: Model No. Part No. Serial No. Date of Purchase Page 19

Toll-free 1-800-363-8010 Phone (403) 258-3100 Fax. (403) 253-4967 http://www.guardiantelecom.com E-mail: mailto:sales@guardiantelecom.com (Click to open message box) CONNECTED. PROTECTED. Guardian Telecom Inc. 2015