MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

Similar documents
MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NEWGATE TECHNOLOGIES, INC.

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

SECTION AIR COMPRESSORS AND ACCESSORIES

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact:

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Owners Manual Refrigerated Air Dryer MHT SERIES

INSTRUCTION AND MAINTENANCE MANUAL

CHILLER. Operator s & Installation Manual

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

PDF Created with deskpdf PDF Writer - Trial ::

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

T-Series Air Conditioner T53 Model

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

T-Series Air Conditioner T15 Model

User s Information and Installation Instructions

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

MODEL MW200 MODEL MW600 AIR DRYER

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

MODULAR AUTOMATIC GRANULAR ICE FLAKER

RNP SERIES 33 F 39 F 1 C 4 C OFF OPERATOR MANUAL

AUTOMATIC MODULAR ICE FLAKER

Refrigerated & Desiccant Compressed Air Dryer Product Selector

CHILLER. Model CH3000. Operator s & Installation Manual

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

T-Series Air Conditioner T20 Model

OPERATION & MAINTENANCE MANUAL RHS680

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Installation, Operation, and Maintenance Information

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

AQUAMAC MODELS

VSA Series Air Dryer. User s Guide

OPERATORS MANUAL. Direct expansion compressed air dryers CONTENTS. Models DFLO 130 DFLO 170 DFLO 220 DFLO 270 DFLO 360 DFLO 420 DFLO 530 DFLO 600

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Operation and Maintenance Manual

Sullair Drains for Compressed Air Systems Zero Air Loss and Timed Solenoid

AUTOMATIC GRANULAR ICE FLAKER

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Refrigerated Compressed Air Dryers Models DRD 200, 250, 300, 400, 500, 600, 750 Instruction Manual

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

User s Information and Installation Instructions

User s Information and Installation Instructions

AUTOMATIC MODULAR ICE-CUBE MAKER

DRYMAX DRYMAX DRYMAX DRYMAX

Refrigerated Air Dryers

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

Energy-Saving Industrial Water Chillers

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

CAMAIR THE LEADER IN DRY AIR TECHNOLOGY

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Freestanding Wine Cooler Instruction Manual

CH250 AND CH251 CHILLERS

Refrigerated Compressed Air Dryers

OPERATING INSTRUCTIONS

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Refrigerated Compressed Air Dryers 5-6,000 scfm

10/2017. Mod: WR-FP600-X. Production code: AGBS-600RI /

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Installation Instructions

Refrigeration Dryers WDRD

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

AUTOMATIC ICE-CUBE MAKER

Air Dryers & After Coolers Dry Land

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

Transcription:

MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap Operation & Maintenance Manual MDX MODELS 18 THRU 250 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY 2 1.0 GENERAL INFORMATION 2 1.1 Standard equipment 1.2 Description 1.3 Use 1.4 Safety instructions 2.0 MACHINE UNPACKING AND HANDLING 3 2.1 Unpacking and handling 2.2 Package disposal 3.0 SET UP 4 3.1 Machine positioning 3.2 Installation 3.3 Start-up 3.4 Decommissioning 3.5 Control panel 4.0 INTELLIDRAIN ZERO LOSS DRAIN TRAP 6 4.1 Operation 4.2 Controls 4.3 Maintenance 5.0 MAINTENANCE 6 5.1 Each week 5.2 Each month 5.3 Each 6 months 6.0 TROUBLESHOOTING 7 7.0 TECHNICAL FEATURES 8 7.1 Data sheet 7.2 Wiring diagrams 7.2 Refrigeration diagrams 8.0 INSTALLATION LAYOUT 16 1/16 Cod. 710.063.01.00 Rev.04 02.05.02

HOW TO USE THIS MANUAL All features of this equipment, all information on safety, installation, operation, adjusting and maintenance are described in this manual. This manual is integral part of this equipment, and should absolutely be read and understood by any person operating and maintaining this machine. Should this machine be sold again, this manual should be given to the new machine owner. Should this manual be lost, please ask for a new copy to your authorized dealer. SYMBOLS The symbols below refer to safety instructions to be followed during installation, operation and maintenance. Other symbols refer to machine features and are either on the dryer or in this document. Air inlet Condensate drain Air outlet Direction of rotation of fan motor Danger! Electrical Hazard WARRANTY This product has been factory tested before shipment. It is guaranteed to be free from defects in material and/or workmanship for a period of 12 months from the date of shipment. This warranty applies provided the machine has been installed and used in accordance with the instructions detailed in this manual. The manufacturer agrees, at its discretion, to repair or replace all defective parts free of charge. Further, the manufacturer agrees to cover charges associated with field labor required to make authorized warranty repairs, provided the Motivair warranty policy is followed and an S.I.R. authorization is issued by Motivair. Labor coverage shall be limited to maximum rates as published in the latest price list. All field repairs may only be performed by a factory authorized service technician. This warranty is limited to defects associated with operation and manufacture only. All parts subject to wear due to their normal operation are not covered by this warranty. All transportation costs associated with factory repair of equipment are the sole responsibility of the owner. 1.0 GENERAL 1.1 standard equipment Instruction and maintenance manual. Wiring diagram. Condensate drain unit (where not already fitted). 1.2 description These dryers have been designed to eliminate moisture contained in compressed air by lowering its temperature to 33-39 F. These dryers take advantage of a sealed refrigeration system. The air delivered by this dryer is free of all liquid condensate, which is first accumulated in the separator, then discharged from the dryer by an electronic zero-loss drain (Intellidrain). If the compressed air load (temperature and/or scfm flow) imposed on the dryer is more than the rated capacity, this will result in a higher dew point, but will not cause a safety issue. Make certain the dryer is not connected to a system pressure higher than the rated maximum. ATTENTION: This dryer is supplied with a power disconnect switch (S1). The authorized electrical contractor is responsible for the correct power supply, in accordance with local and national electrical codes. A start/stop switch (ON/OFF) allows the dryer to be turned on and allows normal operation. This dryer is equipped with a refrigeration circuit safety device to prevent damage. A high-pressure switch opens the compressor s contacts at a preset pressure and remains in this position until the reset button is activated. The reset button remains enabled until the line pressure returns to the factory-set safe level. A Klixon protection device on the compressor prevents damage to the compressor from electrical or thermal overload. This is an automatic re-setting device. 2/16 Cod. 710.063.01.00 Rev.04 02.05.02

1.3 use - The use of a dryer is recommended for the treatment of compressed air when a low moisture level is required for general manufacturing processes. 1.4 general safety instruction - Read this manual carefully before performing any installation, or maintenance operation. This machine has been designed and to be used as described below. Any other use is not advised. Specialized personnel must perform any maintenance or cleaning operation. The Suppier is not responsible for any use other than the intended use, or any use not in compliance with the instructions in this manual. WHAT SHOULD BE DONE: Be familiar with all controls. Before performing any maintenance make sure that the dryer is not connected to the compressed air system (inlet & outlet isolation valves closed) and the dryer is fully depressurized. Before removing the outer panels unplug the dryer and allow 15 minutes for it to cool down. Before removing the cooling fan protection guard make sure the dryer is electrically isolated. Make sure that all protection panels are properly fitted while the machine is working and after any maintenance operation. Make sure that the intake air is free from flammable fumes or vapors that might cause either explosion or fire risk. WHAT SHOULD NEVER BE DONE: Never place flammable objects near the dryer. Never use the dryer if the power cable is faulty or the connection is not safe. Never allow anyone to operate the dryer without giving him or her proper instructions. Never tamper with safety devices. Never hit refrigerant pipes with heavy or sharp objects. They contain refrigerant gas under pressure. Never touch any part of the cooling circuit when the machine is running. They are very hot! Never drain the condensate directly into the sewer system. This equipment has been designed to comply with all current safety regulations. All installation, use and maintenance operations should therefore be performed according to the instructions in this manual. Qualified and specialized personnel only, fully familiar with safety precautions to be taken should perform any cleaning/maintenance operation on the dryer. 2.0 MACHINE UNPACKING AND HANDLING 2.1 unpacking and handling The dryer is supplied in a cardboard crate and should always be handled in an upright position, using a suitable and safe lifting device. (see technical data). After cutting straps (always wear safety gloves & glasses and cut them either with scissors or cutting snips), take the dryer out. Remove the package from the top, remove the wooden pallet and place the dryer in the designated location. 2.2 package disposal - We recommend the package is stored so that it can be used again in case the dryer should ever be moved. Keep it at least for the warranty period. If needed, it will be easier and safer to pack the dryer and send it to a service center. If the package is not stored, it should be disposed of in a responsible manner. 3/16 Cod. 710.063.01.00 Rev.04 02.05.02

3.0 SET-UP 3.1 Dryer Positioning - The dryer should be placed in a suitable equipment room with the following features: Completely level floor; protected against weather conditions and direct sunlight; Properly ventilated, to maintain the room temperature within 41 F and 104 F even when the dryer is running. Allow at least 3 feet around the dryer for proper air circulation. Note the dryer adds heats to the room when operating. 3.2 Installation - Before installation check that the piping to be connected to the dryer is clean inside and does not contain any dirt or installation debris. Install the machine as follows: Connect the dryer to the air compressed line in compliance with one of the diagrams shown in fig. 6 and the instructions on the adhesive labels described on page 1. A 3-valve by-pass line is recommended. This will enable the dryer to be isolated from the compressed air system for repairs or maintenance, without interrupting the flow of compressed air to the factory or process. Connect the condensate drain tube in compliance with local regulations. The condensate from a lubricated compressor cannot be drained directly into the sewer system since it is a pollutant. A water-oil separator of suitable capacity is therefore recommended. Consult your local Motivair distributor for more information. Make sure the electrical power supply is in compliance with electrical data on the dryer nameplate, as well as local and national electrical codes. Always fit a fused disconnect in the power supply to the dryer. It is the responsibility of the installing electrical contractor to insure the correct wire and fuse sizing. A particulate pre-filter is always recommended to avoid the possibility of installation debris, rust, dirt or other particulates from blocking the heat exchangers in the dryer. Consult your local Motivair distributor for details. A coalescing oil removing filter is always recommended for lubricated compressors. Used compressor oil is not suitable for other compressed air operated machinery, and can cause product spoilage. Consult your local Motivair distributor for details. Position the dryer so that all controls can be easily read and all maintenance operations easily performed. 3.3 Start-Up Make sure the inlet & outlet isolation valves are closed. Turn the power switch (S1) on position 1, to activate the dryer. Push and hold the (ON/OFF) button on the control panel for 3 seconds. Wait for at least 15 minutes until the dryer has stabilized. Open the outlet isolation valve and then open the inlet valve. Finally, slowly close the by-pass valve. In this way, the plant is gradually pressurized. If the compressed air load to the dryer (temperature, scfm flow or both) exceeds the rated capacity of the dryer, the dew point will be higher, but this will not effect the safety or integrity of the dry r.(see technical data). 3.4 Decommissioning - In the event there is a need to move the dryer, proceed as follows: 1. Isolate the unit from the compressed air line in the reverse order described in start-up above. 2. Completely depressurize the dryer s air circuit by using the condensate drain (TEST button); 3. Disconnect and lock out the electrical power supply to the dryer. Packing and transport of faulty machines - Repack the dryer in its original box or with a similar one of the same dimensions. The dryer must be kept vertically and packed as supplied from the manufacturer. Make sure the dryer is securely banded to a wood pallet, and marked FRAGILE. Do not transport the dryer without the correct packing. It may be damaged irreparably, and this would be the customer s responsibility. MATERIALS RETURNED WITHOUT CORRECT PACKAGINGING AND COMPLETE DOCUMENTATION WILL NOT BE ACCEPTED. 4/16 Cod. 710.063.01.00 Rev.04 02.05.02

3.5 Control Panel - These dryers are equipped with an electronic controller that controls the basic operating parameters. WARNING FOR USER: IT IS FORBIDDEN TO MODIFY THE OTHER SETTING PARAMETERS OF THE ELECTRONIC CONTROLLER WITHOUT THE MANUFACTURER S AUTHORIZATION. ANY VARIATION TO THE CONFIGURATION PARAMETERS CAN CAUSE FAILURE. The control panel consists of 5 buttons (ON/OFF, TEST, SET, DOWN and UP) and a three-digit display with three warning LED s shown as DP1, DP2, DP3. Mod.18-30-40-60-75-100 Warning LED DP1 On = N/A DP2 On = Condensate drain energized DP3 On = Compressor energized Mod.150-250 Warning LED DP1 On = Compressor energized DP2 On = Condensate drain energized DP3 On = Refrigerant solenoid valve energized Digital display Message (not flashing) Numeric Value Description Dew Point Temperature Fault displays The controller is able to recognize particular types of faults in the drying circuit. When this occurs, the display shows a flashing alarm message alternating with the dew point. Message (flashing) HtA LtA PF1 Cause High temperature alarm Low temperature alarm Faulty temperature probe All the alarm messages immediately disappear when the fault which has caused them clears, except for the PF1, which requires the unit to be switched off and then re-started (main power switch). PF1 has a priority over all other messages. 5/16 Cod. 710.063.01.00 Rev.04 02.05.02

4.0 INTELLIDRAIN ZERO LOSS DRAIN TRAP 4.1 Operation The Intellidrain is designed to remove condensate from any compressed air application without air loss. It is completely automatic, and requires no external settings or adjustments. A two-stage condensate level sensor installed in the trap s internal cavity signals both the beginning and the end of the discharge cycle so the trap discharges only liquid and no air is wasted regardless of load. At start-up, purge any air from the trap s inlet connection by pushing the TEST button several times. The factory-installed inlet filter should be examined and cleaned daily for the first week of operation, and monthly thereafter. 4.2 Controls Green LED: Red LED: Pushbutton: Electrical Power ON Discharge Solenoid Energized (valve open) Discharge TEST (Open Valve Manually) 4.3 Maintenance Close the ball valve located on the filter/stop installed at the drain trap inlet. Depressurize the trap by pushing the TEST button. Unscrew the plug in the end of the filter/stop to access the filter screen. Clean the filter screen with a compressed air jet. Reassemble and open filter/stop valve. 5.0 MAINTENANCE 5.1 Weekly - Check visually if the condensate is properly drained. 5.2 Monthly Check and replace pre-filter element if necessary. 5.3 Every 6 months Disconnect the dryer and lock out the power supply before performing the following: Depending on the room temperature, quality of the ambient air, and at the beginning of summer, remove the side panel. Clean the condenser coil with compressed air to remove possible dust or deposits that could impair the condenser performance. Take care not to damage or crush the aluminum fins. Check the compressor power consumption with reference to the nameplate or the data sheet on this manual (see chapter 7.1). 6/16 Cod. 710.063.01.00 Rev.04 02.05.02

6.0 TROUBLESHOOTING SYMPTOM POSSIBLE ORIGIN SOLUTION Temperature shown in display is higher than preset value High compressed air inlet temperature High compressed air flow High ambient air temperature Fouled refrigerant condenser Low refrigerant charge Faulty refrigerant compressor Faulty refrigerant solenoid valve Faulty fan thermostat Faulty control relay Refrigerant high pressure switch open Reduce air temperature to within design limits Reduce air flow to within design limits Increase ventilation rate of installation area Clean condenser Locate & repair leak & re-charge Repair or replace Repair or replace Repair or replace Repair or replace Eliminate cause & reset switch Excessive air pressure drop across dryer Inlet/outlet piping reversed Thermostat sensor out of well Faulty thermostat Ambient temperature below freezing Obstruction in air circuit Connect properly Re-install Repair or replace Install dryer in heated space Locate & remove blockage Water present in air downstream of dryer Air by-pass valve open Condensate drain strainer fouled Faulty condensate drain High dew point temperature Close valve Clean strainer Repair or replace See Symptom #1 above Fan doesn't start and/or stop. Faulty fan pressure switch Low refrigerant charge Low load with low ambient temperature Repair or replace Locate & repair leak & re-charge Install dryer in heated space 7.0 TECHNICAL FEATURES 7.1 Data sheet Model UNITS MDX 18 MDX 30 MDX 50 MDX 75 MDX 100 MDX 120 MDX 150 MDX 200 MDX 250 MDX 250 Air flow rate SCFM 18 30 50 75 100 120 150 200 250 250 Compressor Power HP 1/6 1/4 1/3 3/4 1 1-1/2 1-1/2 1-1/2 2 2 Nominal Current* A 1.1 2.7 5.2 6.8 8.1 9.2 7.5 6.8 9.6 3.8 Full Load Current A 2 4.6 6.9 10 13 11 10.5 9 26 5.3 Locked Rotor Current A 21 35 28 33 46 46 38 49.3 73 19.5 Power supply V/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 230/1/60 230/1/60 230/1/60 460/3/60 Air connections NPT 1/2 1/2 3/4 3/4 1-1/2 1-1/2 1-1/2 R-134a 1-1/2 1-1/2 Refrigerant type R134a R134a R134a R134a R134a R134a R134a 1-1/2 R134a R134a Weight lbs. 64 66 88 104 185 210 210 232 219 219 Maximum Ambient F 104 104 104 104 104 104 104 104 104 104 Maximum Air Inlet F 113 113 113 113 113 113 113 113 113 113 Maximum Pressure psig 232 232 232 232 232 232 232 232 232 232 @ Rating conditions of: 100 F & 100 psig air inlet, 100 F ambient, 33-39 F dew point 7/16 Cod. 710.063.01.00 Rev.04 02.05.02

MDX 18-30 MDX 50 75 100 MDX 120 150 200 250 8/16 Cod. 710.063.01.00 Rev.04 02.05.02

7.2 Wiring diagrams MDX 18 30 (115/1/60) Cod. 714.016.03.00 - Rev. 01 10.01.01 MDX 50 75 (115/1/60) Cod. 714.016.01.00 - Rev. 02 29.04.2002 9/16 Cod. 710.063.01.00 Rev.04 02.05.02

MDX 100 (115/1/60) Cod. 714.014.01.00 - Rev. 02 29.04.02 MDX 120 (115/1/60) Cod. 714.014.03.00 - Rev. 00 29.04.02 10/16 Cod. 710.063.01.00 Rev.04 02.05.02

MDX 150 (230/1/60) Cod. 714.019.01.00 - Rev. 02 10.01.01 MDX 200-250 (230/1/60) ELECTRIC WIRING DIAGRAM - Cod. 714.020.01.00 - Rev. 02 29.04.02 11/16 Cod. 710.063.01.00 Rev.04 02.05.02

MDX 200-250 (230/1/60) TERMINAL BLOCK DIAGRAM - Cod. 714.020.01.00 - Rev. 02 29.04.02 MDX 200-250 (230/1/60) COMPONENTS LAYOUT - Cod. 714.020.01.00 - Rev. 02 29.04.02 MDX 250 (460/3/60) POWER WIRING DIAGRAM - Cod. 714.021.01.00 - Rev. 03 29.04.02 12/16 Cod. 710.063.01.00 Rev.04 02.05.02

MDX 250 (460/3/60) CONTROL WIRING DIAGRAM - Cod. 714.021.01.00 - Rev. 03 02.05.02 MDX 250 (460/3/60) TERMINAL BLOCK DIAGRAM - Cod. 714.021.01.00 - Rev. 03 02.05.02 13/16 Cod. 710.063.01.00 Rev.04 02.05.02

MDX 250 (460/3/60) COMPONENTS LAYOUT - Cod. 714.021.01.00 - Rev. 03 02.05.02 MDX 250 (460/3/60) PARTS LIST - Cod. 714.021.01.00 - Rev. 03 02.05.02 14/16 Cod. 710.063.01.00 Rev.04 02.05.02

7.3 Refrigerant circuit diagram 1 Refrigerant compressor 2 Refrigerant condenser 3 Condenser fan 4 Air/Air Pre-cooler Re-heater 5 Refrigerant evaporator 6 Condensate drain trap 7 Expansion device 8 Refrigerant filter/dryer 9 Hot-gas solenoid valve 10 Fan pressure switch 11 High pressure safety switch 12 Condensate separator 13 Isolation valve with strainer 14 Liquid separator MDX 18 30 - Cod. 713.006.02.00 Rev.00 MDX 50 75 - Cod. 713.007.02.00 - Rev. 00 MDX 100 - Cod. 713.007.03.00 - Rev. 01 MDX 120-150 - Cod. 713.008.03.00 - Rev. 00 MDX 200-250 - Cod. 713.008.02.00 - Rev. 00 15/16 Cod. 710.063.01.00 Rev.04 02.05.02

8.0 INSTALLATION LAYOUT Fig. 6 INSTALLATION LAYOUT 1 Compressor 7 Dryer 2 Aftercooler 8 Drain Solenoid Valve 3 Condensate Separator 9 Coalescing oil filter (.1 microns) 4 Tank 10 Coalescing oil filter (0.01 microns) 5 Automatic Condensate Drain 11 Activated Carbon Filter 6 Particulate Pre-filter 12 Water/Oil Condensate Separator 16/16 Cod. 710.063.01.00 Rev.04 02.05.02