ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

Similar documents
D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

RESIDENTIAL GAS WATER HEATERS

PROPANE CONVERSION INSTRUCTIONS. Applies to: Gas-Fired, Tubular Radiant, Low-Intensity Infrared Heater

GV Series 4 Section Assembly

Service Parts, Kits and Accessories

TECHNICAL INSTRUCTIONS

Installation Instructions

Installation Instructions

NAURAL GAS HIGH ALTITUDE CONVERSION INSTRUCTIONS

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

TECHNICAL INSTRUCTIONS

NATURAL GAS CONVERSION KIT

Installation Instructions

MOUNTING INSTRUCTIONS

FLAME DETECTOR ADAPTERS 8832 through 8839 and Series R Bulletin 8832

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

TECHNICAL INSTRUCTIONS

P10KW / P15KW Air Dryer Installation Guide

gas Understanding Gas Appliance Conversions READ ALL INSTRUCTIONS

Heat Exchanger Block Replacement Instructions

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

TECHNICAL INSTRUCTIONS

MODEL 4246 MIXER-GRINDER

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

Camaro A/C Install Instructions

Heater with Air Conditioning. E-Series Ford Aeromaster

English, French & Spanish No Color

PURGE STANDARD IPC AIR DRYER LABEL

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Installation Instructions

Single-Control Bathroom Sink Faucet

INSTALLATION GUIDE Dual Fuel Ranges

Single-Control Lavatory Faucet

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

TEMPERATURE CONTROLLERS

Installation Manual PS-200 & PS-201

CORALAIS BODYSPA BATH AND SHOWER FAUCET

TECHNICAL INSTRUCTIONS

Ultra Boiler Series 1 & 2 Jacket Parts

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

FIREPLACE INSTALLATION

Installation Manual PS-225 & PS-275

AJ-44 Rack Conveyor Dishmachine Maintenance Instructions. Changing Conveyor Direction

SIDEBURNER WARRANTY REPAIR KIT FOR OUTDOOR USE ONLY Repair kit For use with Char-Broil RED Series Grills Only.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

CABS/BLADES/ SPREADERS/ACCESSORIES

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Saunier Duval Clima, S.A.

INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

LGB Gas fired boiler

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Water Distiller Service Manual

INSTALLATION INSTRUCTIONS

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Altra Series Dampener

*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above sea level.

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

SAN JUAN FRESH WATER COOLING SYSTEMS

Platen Heater Pad Replacement

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

an ISO 9001:2015 Registered Company

TECHNICAL INSTRUCTIONS

30 & 36 FLUSH-MOUNT GAS COOKTOPS

569, 570, 571, 572 Series

Using it in an enclosed space can kill you.

569, 570, 571, 572 Series

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

Owner s Manual and Instructions

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

Product Support Bulletin

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SuperKlean Washdown Products

Basin Set INSTALLATION INSTRUCTIONS

Installation Instructions

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

Evergreen Liquid Propane Conversion

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

High-Density Industrial

WSK300 Multifunction Wall Control

SuperKlean Washdown Products

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Manual. P36D Gas Log Fireplace. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Models: P36D-NG2 P36D-LPG2

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Dishwasher installation guide

LNB 1000 Series Low Nox Burner

MILLENIUM MEMBRANE REPLACEMENT. Tools and Materials Required. Initial Preparation

Service Bulletin Trucks Date Number Page

Effective october 14, 2014

HEARTH PRODUCTS KITS AND ACCESSORIES. KIT CONTENTS (See Figure 1) TOOLS NEEDED

Repair Parts List DRYER MODEL NUMBER MDG30MNAWW. When requesting service or ordering parts, always provide the following information:

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

TC MODULE (FFD) (with Gas Hob)

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

LOW PROFILE SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS SPK-26 PILOT KITS

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Transcription:

ASSEMBLY and INSTALLATION INSTRUCTIONS Gas Conversion Kit Tube Heaters View these instructions online at www.lbwhite.com Kit Contents: DESCRIPTION QTY. Instructions 1 Burner orifi ce 1 Manifold pipe 1 Burner inlet plate 1 Air inlet plate 1 Conversion documentation label 1 Honeywell conversion kit to Natural Gas 1 Pipe thread compound 1 Burner vane (Sentinel 125 & 150 ONLY) 1 Copper tube (Sentinel 125 & 150 ONLY) 1 ¼ Clamp (Sentinel 125 & 150 ONLY) 1 Gasket (Sentinel 125 & 150 ONLY) 1 Pressure switch orifi ce 1 Tools required: Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key Materials required: 2- Gas pressure gauges capable of reading up to 35 in. W.C. (may also be ordered from L.B. White, part number 00764) 2-1/8 NPT hose barb fi tting General Purpose silicone sealant Requirements: You must read and understand these instructions before beginning the conversion. You must be properly trained and have suffi cient experience to install the gas conversion kit and test the heater for proper operation. Ensure the installation s gas type and pressure conform to the gas type and pressure requirements given on the conversion documentation label within the conversion kit. Ensure piping is of appropriate size for natural gas fl ow capacity. Discussion: The following instructions are common for use when converting fuel gas for single stage and two stage tube heaters. Where appropriate, specifi c instructions pertaining only to two stage heaters will be identifi ed. These instruction pertain to only B design Oval 80 and C design Sentinel tube heaters. Refer to the dataplate on the burner box to determine design sequence (design sequence is the FIRST letter in the confi guration number). If unsure, call L.B. White Company. Some components might not be used in conversion. General Instructions: Close the main gas supply valve to the heater, and disconnect the heater s electrical supply. For reassembly, reverse the respective service procedure. Use pipe thread compound at all threaded connections. Ensure all threaded connections are tightened securely. WORLD PROVIDER - INNOVATIVE HEATING SOLUTIONS 411 Mason Street, Onalaska, WI 54650 800-345-7200 608-783-5691 608-783-6115 (fax) www.lbwhite.com

2 Gas Conversion Kit - Tube Heaters Section A: Changing Burner Inlet Plate / Orifice 1. Remove the ignitor mounting screws and igniter. See Fig. 1. Do not force or bend ignitor during removal process. FIG. 1 Screws 2. Remove the pressure switch tube from copper burner tube and remove burner mounting nuts. See Fig. 2. FIG. 2 Tube www.lbwhite.com (4) Mounting Nuts

Gas Conversion Kit - Tube Heaters 3 3. Slide the burner casting off its mounting studs and pull the burner casting from the burner tube, pivot burner casting as necessary. See Fig. 3. Do not force or bend vanes on burner vane plate during removal process. FIG. 3 Burner Vane 4. Remove orifi ce and burner inlet plate See Fig. 4. FIG. 4 Burner Inlet Plate Orifi ce

4 Gas Conversion Kit - Tube Heaters If manifold pipe is of type 1, continue to step 5. If manifold pipe is of type 2, skip to step 7. Manifold pipe type 1 Manifold pipe type 2 Orifi ce holder 5. Remove manifold pipe. 6. Replace with manifold pipe from kit. Ensure rubber grommet in center partition panel does not fall out. See grommet location in picture of type 2 of manifold pipe. 7. Install orifi ce and burner inlet plate from conversion kit. Sentinel 100 and Oval 80 Reinstall original burner casting using mounting nuts removed earlier. Sentinel 100 skip to section B Oval 80 skip to section C Sentinel 125 and Sentinel 150 ONLY If burner assembly is of type A, continue to step 8. If burner assembly is of type B, skip to step 9. Grommet Burner assembly type A Burner assembly type B www.lbwhite.com

Gas Conversion Kit - Tube Heaters 5 8. Remove bracket bolt. See Fig. 5. FIG. 5 Bracket bolt 9. Remove 9/64 Allen head screws, burner screens, and spacers from burner casting. See Fig. 6. FIG. 6 10. Remove burner vane from burner casting and discard it along with bracket and original copper tube. 11. Remove all sealant from burner head. 12. Place burner gasket from conversion kit onto burner casting head. See Fig. 7.

6 Gas Conversion Kit - Tube Heaters FIG. 7 Gasket 13. Install burner vane from conversion kit along with spacer and burner screens, using screws removed earlier. Securely tighten screws. Ensure the straight edges of the burner screens and the burner vane ignitor opening align with each other. See Fig. 8. FIG. 8 Burner screens straight edges Burner vane ignitor opening www.lbwhite.com 14. Insert copper tube from conversion kit through the burner vane. Install ¼ clamp from conversion kit onto copper tube. See Fig. 9.

Gas Conversion Kit - Tube Heaters 7 FIG. 9 1/4 Clamp 15. Remove clear tube from pressure switch and inspect pressure port for blue orifi ce. If the pressure switch does not have a blue orifi ce, fully insert the blue orifi ce from the conversion kit. See Fig. 10. If the pressure switch does have a blue orifi ce installed, leave as is. FIG. 10 No blue pressure switch orifi ce Blue pressure switch orifi ce, fully inserted 16. Firmly push the clear tube onto the pressure switch port with the blue orifi ce.

8 Gas Conversion Kit - Tube Heaters 17. Install burner casting assembly back onto mounting studs using mounting nuts removed earlier. Ensure ignitor opening of burner vane is directed down toward ignitor mounting screw holes. See Fig. 11. Do not force or bend vanes on burner vane plate during installation. FIG. 11 Ignitor opening of burner vane Ignitor mounting screw holes 19. Firmly push the other end of the clear tube onto the copper tube. 20. Install the ignitor. Pivot ignitor as necessary to ensure ignitor is properly inserted into position. Secure with screws removed earlier. Do not force or bend ignitor during installation process. Section B: Changing Air Inlet Plate 1. Remove supply air fl ex tube from heater. 2. Remove the screws securing the air inlet plate. See Fig. 12. FIG. 12 www.lbwhite.com Screws 3. Remove the air inlet plate. Air inlet plate

Gas Conversion Kit - Tube Heaters 9 Plate is adhered with silicone to Burner Box. 4. Install new air inlet plate from the kit. 5. Reseal around outside of air inlet plate with silicone. (Not Supplied) Section C: Converting the Gas Control Valve 1. Remove the screws securing the valve to the burner box. See Fig 13. FIG. 13 Sentinel Oval 80 Screws (4) Screws (2) 2. Rotate gas control valve for access to regulator cap screw(s). Fig. 14. FIG. 14 Single Stage Valve Regulator cap screw Two Stage Valve Regulator cap screws

10 Gas Conversion Kit - Tube Heaters Single Stage Gas Valve Conversion (Fig. 15.) 1. Remove the regulator cap screw and pressure regulating adjusting screw. 2. Remove the existing spring (red) from the gas control valve. 3. Install the spring (silver) and pressure regulating adjusting screw from the Honeywell conversion kit. 4. Ensuring the pressure regulating adjusting screw is fl ush with the regulator top; turn the adjusting screw clockwise 10 complete turns. 5. Continue to Section D FIG. 15 www.lbwhite.com

Gas Conversion Kit - Tube Heaters 11 Two Stage Gas Valve Conversion (Fig. 16.) 1. Remove pressure regulator cover screws. 2. Remove pressure regulator cover. 3. Removed the existing spring (black) from the gas control valve. Install the spring (white) from the Honeywell conversion kit. 4. Install pressure regulator cover onto valve. Tighten regulator cover screws securely. FIG. 16

12 Gas Conversion Kit - Tube Heaters Section D: Setting Gas Pressures 1. Using the 3/16 Allen key, remove the pressure tap plug from the outlet and inlet of the gas control valve. 2. Securely connect pressure barb fi ttings to the gas control valve. See Fig. 17. FIG. 17 Single Stage Valve Outlet pressure barb fi tting Inlet pressure barb fi tting Two Stage Valve Outlet pressure barb fi tting Inlet pressure barb fi tting www.lbwhite.com

Gas Conversion Kit - Tube Heaters 13 3. Route gauge tubing through burner box air inlet to gas control valve. See Fig. 18. FIG. 18 Outlet gauge tube Inlet gauge tube Single stage valve shown for representation of gauge tubing connection. 4. Install gauge tubes onto pressure barb fi ttings. 5. Trace the connected tubing back to the respective pressure gauge to determine which pressure gauge will measure inlet pressure or burner manifold pressure. 6. Close and latch the burner box panel. Open the fuel supply valves to the heater. 7. Reconnect the heater s electrical supply, and start the heater.

14 Gas Conversion Kit - Tube Heaters Section E: Setting Gas Pressures General Instruction The pressure read at the inlet of the gas control is Inlet Pressure. The pressure read at the outlet of the gas control valve is burner manifold pressure. Refer to the Gas Conversion Documentation Label suppled with the conversion kit. Ensure pressures are set according to required specifi cations given on Gas Conversion Documentation Label. Verify proper inlet pressure. If the inlet pressure to the gas control does not agree with the Conversion Documentation Label, then the regulator controlling gas pressure to the heater requires adjustment. Proceed after proper inlet pressure has been established. Verify proper burner manifold pressure. If the pressure is less or greater than what is specifi ed on the Conversion Documentation Label, adjustment of the burner manifold pressure is required. The burner box panel must be closed and latched for ignition to occur. The gas pressures setting process may require several adjustments of the burner manifold pressure. Therefore, several openings and closings of the burner box panel may be necessary. Single Stage Gas Valve 1. Turn the regulator adjusting screw clockwise (CW) to increase or counterclockwise (CCW) to decrease the burner manifold pressure. Adjust pressure as needed. See Fig. 19 Single Stage. With the heater operating, the pressure gauges must read the pressures specifi ed on the natural gas conversion documentation label. 2. Once pressure has been set close the heater gas supply valve and disconnect from its electrical supply. 3. Proceed to Section F for completion. FIG. 19 Regulator adjusting screw www.lbwhite.com

Gas Conversion Kit - Tube Heaters 15 Two Stage Gas Valve 1. Start the heater to operate on high heat 2. Remove the pressure regulator adjustment cap. 3. Use the 3/32 Allen key to adjust the high pressure regulator to match the Conversion Documentation Label. 4. Turn the inner adjustment screw for HI pressure clockwise (CW) to increase or counterclockwise (CCW) to decrease the gas pressure. After high manifold pressure has been checked, set heater to operate on low heat. 5. Adjust the low pressure regulator to match the Conversion Documentation Label. 6. Turn the inner adjustment screw for LO pressure clockwise (CW) to increase or counterclockwise (CCW) to decrease the gas pressure. See Fig. 20. With the heater operating, the pressure gauges must read the pressures specifi ed on the natural gas conversion documentation label. 7. Once pressure has been set close the heater gas supply valve and disconnect from its electrical supply. FIG. 20 LO adjustment screw HI adjustment screw Section F: Completion For either Single or Two Stage Gas Valve: 1. Remove gauges tubes and pressure barb fi ttings from inlet and outlet of gas control valve. 2. Install the pressure tap plugs, tightening securely.

16 Gas Conversion Kit - Tube Heaters Single Stage Gas Valve Install the O-ring into the groove on the silver regulator cap screw, as supplied in the Honeywell conversion kit. See Fig.21. Install silver cap screw onto the gas control valve. FIG. 21 Two Stage Valve Install pressure regulator adjustment cap onto the pressure regulator cover. See Fig. 22. FIG. 22 Pressure regulator adjustment cap www.lbwhite.com 3. Rotate gas control valve back to original position and secure with screws removed earlier. 4. Apply the Yellow ATTENTION label, as supplied in Honeywell conversion kit, to gas control valve. See Fig. 23.

Gas Conversion Kit - Tube Heaters 17 FIG. 23 Single Stage Valve Yellow attention label Two Stage Valve Yellow attention label 5. Using a pen, enter information as required on the conversion documentation label from the kit. 6. Apply Conversion Documentation Label from kit next to burner viewing window on burner box panel. See Fig. 24.

18 Gas Conversion Kit - Tube Heaters FIG. 24 7. Close and latch the burner box panel. 8. Open the heater s main gas supply valve. 9. Attach supply air fl ex tube onto heater. 10. Start the heater, and check for proper operation. 11. Set thermostat to desired temperature. www.lbwhite.com

Gas Conversion Kit - Tube Heaters 19 Notes

Service Contact your local L.B. White dealer for replacement parts and service. You may also call the L.B. White Co., Inc. at 1-800-345-7200, for assistance, or email us at customerservice@lbwhite.com. Be sure that you have your heater model number and confi guration number when calling. WORLD PROVIDER - INNOVATIVE HEATING SOLUTIONS 411 Mason Street, Onalaska, WI 54650 800-345-7200 608-783-5691 608-783-6115 (fax) www.lbwhite.com 150-30472 REV.A