Life Safety Code Potpourri

Similar documents
UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Established /10/2015. Doran Pruisner Dan Wood

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

rpsa FIRE PROTECTION ENGINEERS

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

2017 Accreditation Updates

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time.

Are there any policies regarding outlets that contain USB ports?

FIRE ALARM PRE-INSPECTION CHECKLIST 1. REFER TO CHAPTER 10 OF CURRENT STATE ADOPTED NFPA 72, FOR INSPECTION, TESTING AND MAINTENANCE PROCEDURES.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

EC 5.10 FIRE PREVENTION MANAGEMENT

HIGH-RISE RETROFIT ORDINANCES - NO and NO

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Chapter 4: Fire Protection Systems

B. The Facility Emergency Planners and Alternate Planners will successfully complete the in-house DJJ Fire Prevention course.

NFPA 101 Life Safety Code Culture change 2012

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

Agency for Health Care Administration

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

Date Issued: December 14, 2017 Revision: 2.1

Narrative Reports As Regulated by 780 CMR, Section 903.0

Changes in NFPA

Heathcare Interpretations Task Force

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6

Unified Fire Authority - Fire Prevention Bureau

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

Agency for Health Care Administration

May 27, Mayor Thomas M. Roach Members of the Common Council City of White Plains 255 Main Street White Plains, New York 10601

Impairments to Fire Protection Equipment

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

DEALING WITH FIRE SAFETY

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

May 27, Mayor Joanne D. Yepsen Saratoga Springs Commissioners City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Fire Safety Plan FOR. Business/Property Name: Address: Phone Number: Occupancy Classification. Approved by Fire Inspector: Date:

INITIAL FIRE ASSESSMENT REPORT (FAR)

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC

CMS Regulatory Update & Survey Trends: Life Safety Code

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

Winnipeg Fire Department Fire Prevention Branch

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

FIRE PREVENTION AND PROTECTION*

Southaven Fire Department Fire Marshal s Office 8710 Northwest Drive Southaven, Mississippi Phone: Fax:

Fire & Life Safety Practices

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

VERIFICATION OF FIRE ALARM SYSTEMS

K SURVEY FOR DATE OF PLAN APPROVAL SURVEY UNDER

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Fire Alarm System Fundamentals

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

INSPECTION AND TESTING FORM

HLS Checklist Explanation and Examples

NFPA Changes

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

Baseline Data Required for AS

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

Agency for Health Care Administration

Review of Revisions to NFPA 1, 2015 Edition

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

System Test Report CLEAN AGENT

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

LIFE SAFETY CODE MAINTENANCE MANUAL

Full Service Central Station Fire Alarm Listing Evaluation

Life Safety Code Comparison

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Procedure DESCRIPTION/OVERVIEW

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Florida Building Code 2010

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Circulation Report for SIG-TMS Comments Document # 72

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

4/9/2014. Life Safety Code. Nursing Facility Life Safety Code Today and Tomorrow. Kenneth Daily, LNHA.

FIRE SAFETY AND PREVENTION POLICY

2018 NICET Code Transition Changes

Sheetz Inc. Fire Protection Service Guidelines

EXCELSIOR FIRE DISTRICT

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

The Healthcare Environment Update

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Transcription:

Life Safety Code Potpourri

JAMES P. LOVELAND P.E. MINNESOTA DEPARTMENT OF HEALTH Engineering Services Section

FEDERAL MONITORING SURVEYS 2007 2008 2009 No. of FMSs 20 20 20 No. of Deficiencies 332 252 173 Defs/Survey 16.6 12.6 8.65 % Drop ---- 24% 33%

FEDERAL MONITORING And the winner is.. SURVEYS K144: GenSet inspection and testing (3 rd year at #1 or #2) Runner up.. K052: Fire alarm testing (3 rd year at #1 or #2)

K144 GENERATOR INSTALLATION, TESTING, AND MAINTENANCE Type I and Type II EESs must use a Level I generator in accordance with NFPA 110 Level 1 generators must be inspected weekly and tested under load monthly

K144 GENERATOR INSTALLATION, TESTING, AND MAINTENANCE (cont.) Weekly inspections As specified by the manufacturer If manufacturer weekly inspection requirements are unknown, the maintenance schedule in NFPA 110, Appendix A, can be used

K144 GENERATOR INSTALLATION, TESTING, AND MAINTENANCE (cont.) Weekly inspections and monthly tests must be completely documented Monthly yload testing must meet one of the following minimum requirements for 30 minutes

K144 GENERATOR INSTALLATION, TESTING, AND MAINTENANCE (cont.) At not less than 30% of nameplate rating With a load that t maintains i the minimum i exhaust temperature as recommended by the manufacturer

K144 COMMON PROBLEMS Generator lacks a remote annunciator panel This requirement has been in existence in a less comprehensive form since the 1960s

K144 COMMON PROBLEMS (cont.) Older installations need a minimum panel Audible trouble indicator Visual indicators for trouble and generator operation Storage in generator enclosures Indoor generators lack battery-powered task illumination

K144 COMMON PROBLEMS (cont.) Natural gas fueled generator lacks proof that the fuel source is reliable (cited at K146) Test documentation problems Visual inspections are not described

K144 COMMON PROBLEMS (cont.) Must be itemized each week Must be a document that shows all weekly visual inspections that can be referenced during tests and documentation review

K144 COMMON PROBLEMS (cont.) Monthly load tests not completely documented Measurements taken from one leg only on a 3-phase generator Comment that test was more than 30% of nameplate rating with no supporting documentation

K146 LETTER OF RELIABILITY Reliability of natural gas fuel source can be proven with a letter from natural gas vendor that contains the following A statement that the fuel source is reasonably reliable

K146 LETTER OF RELIABILITY (cont.) Description supporting the reasonable reliability assertion A t t t f th l lik lih d f A statement of the low likelihood of an interruption

K146 LETTER OF RELIABILITY (cont.) Description supporting the low interruption assertion Signature of technical personnel An S&C Bulletin has been drafted by CMSCO addressing this issue

K146 LETTER OF RELIABILITY (cont.) This S&C Bulletin includes the elements detailed in the previous slide The intent of the S&C Bulletin is to assure uniform enforcement of these requirements across the United States

K052 FIRE ALARM SYSTEM TESTING AND MAINTENANCE Testing and maintenance of the fire alarm system must be conducted at the proper frequency in accordance with NFPA 72, Tables 7-3.1 and 7-3.2 Different components have different test and inspection i frequencies

K052 FIRE ALARM SYSTEM TESTING AND MAINTENANCE (cont.) Test frequencies for all systems Quarterly l testing of the off-premises transmission equipment Annual test of the entire fire alarm system

K052 FIRE ALARM SYSTEM TESTING AND MAINTENANCE (cont.) Quarterly testing Off-premises i transmission i equipment This test can be done as part of the fire drills if receipt of the fire alarm signal is verified and documented

K052 FIRE ALARM SYSTEM TESTING AND MAINTENANCE (cont.) Annual testing Must be conducted in accordance with NFPA 72, Chapter 7 and documented in accordance with NFPA 72, Figure 7-5.2.2

K052 FIRE ALARM SYSTEM TESTING AND MAINTENANCE (cont.) Vendors are not required to use NFPA form, however; all information in the NFPA form must be included in the vendor created form Items that are not applicable must be marked as such (N/A) and not omitted from the form

ISSUES DISCUSSED AT LIFE SAFETY CODE MANAGERS MEETING IN CHICAGO (April 14 15, 2010)

ADOPTION OF A MORE CURRENT EDITION OF NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARD 101 (LIFE SAFETY CODE) CMS staff indicated d that t they are considering i adoption of the 2012 edition of the Life Safety Code Adoption would occur in 2014 or later

INTERIOR FINISHES NFPA TIA (Temporary Interim Amendment) 00-2 amends Section 10.2 of National Fire Protection Association (NFPA) Standard 101 (Life Safety Code, 2000 edition) Exception No. 2 has been added to 10.2.1

INTERIOR FINISHES (cont.) The exception reads: Approved existing installations i of materials applied directly to the surface of walls and ceilings in a total thickness of less than 1/28 in. (0.9 mm) shall be permitted to remain in use and the provisions i of f1022 10.2.2 through h102353 10.2.3.5.3 shall not apply. Effective March 24, 2010

WHAT DOES THIS MEAN TO US? CMS staff indicated that it would take approximately 30 months to adopt this new TIA If you have a SINGLE LAYER of wall paper installed with no documentation, o and you want to maintain this wall paper, it is recommended that you determine e e the thickness of the wall paper (use a micrometer)

WHAT DOES THIS MEAN TO US? A waiver for K014 and/or K015 may be possible with proof of thickness (pending adoption of the TIA)

FIRE WATCH POLICY Reference NFPA 101 (00), 9.6.1.8 and 9.7.6.1 It is expected that a facility will implement a fire watch if the automatic fire alarm system or automatic sprinkler system is out of service for more than four (4)hours

FIRE WATCH POLICY (cont.) The written policy must indicate that the fire watch be continuous A written policy is required to address either of these systems being out of service

FIRE WATCH POLICY (cont.) It was verified that continuous means that the fire watch person(s) are not permitted to perform any other duties while they are assigned fire watch duties A detailed explanation of the fire watch policy is included din the Life Safety Code Documentation Project

GAS-FIRED FIREPLACES Reference NFPA 101 (00), 18/19.5.2.2 Nothing new on this issue although MDH and SFMD have anecdotal indication that CMS may be willing to view this equipment as a heating device

GAS-FIRED FIREPLACES (cont.) Good article in the January/February 2010 edition of the NFPA Journal A strong effort is being made to revise the 2012 edition of the Life Safety Code to allow for a more caring and comfortable living environment (commonly referred to as culture change )

GAS-FIRED FIREPLACES (cont.) Gas-fired fireplaces are mentioned in the referenced article

SPRINKLER PROTECTION OF ELEVATOR SHAFTS, HOISTWAYS AND PITS ALL certified nursing homes must be fully sprinkled in accordance with NFPA Standard 13 by Tuesday, August 13, 2013 A facility in Minnesota has proposed using the exception to LSC 18/19.3.5.1 to eliminate sprinklers in the elevator machine room

SPRINKLER PROTECTION OF ELEVATOR SHAFTS, HOISTWAYS AND PITS (cont.) Exceptions to NFPA Standard d 13, 5-13.6, provide a means to eliminate the sprinklers required din the hoistway and pit CMS made it quite clear that alternative protection measures means (to them) an alternate extinguishing method

SPRINKLER PROTECTION OF CLOSETS In discussing the sprinkler mandate, CMS staff reiterated the requirements regarding sprinkler protection of closets (reference S&C-05-38) We all know that at least one sprinkler head is required inside a closet

SPRINKLER PROTECTION OF CLOSETS (cont.) Of particular interest was a statement regarding evaluation of the location of the sprinkler heads relative to the face of the permanently affixedwardrobe Please assure that you know the radius of the coverage pattern for the sprinkler heads protecting the permanently affixed wardrobes

SPRINKLER PROTECTION OF CLOSETS (cont.) If the radius of coverage does not include the entire face of the permanently affixed wardrobe (side to side and top to bottom), the facility may be determined d to be partially sprinkled

HOW ARE WE DOING?? Of the 385 SNFNF and NF facilities, 72 are partially sprinkled and 13 have no sprinkler protection 300, or 78% of Minnesota s certified nursing homes and boarding care homes are fully sprinkled

PROCEDURE IN CASE OF FIRE Reference NFPA 101 (00), 18/19.7.2.2 CMS staff discussed the requirements for a complying health care occupancy fire safety plan Good examples of this plan are included in the Good examples of this plan are included in the Life Safety Code Documentation Project

SO THAT S WHAT THEY LOOK FOR CMS staff prepared a good PowerPoint presentation that is really an inside look into Form CMS-2786R MDH has requested an electronic copy of the presentation so that the Minnesota Health Care Engineers Association, Care Providers of Minnesota, and Aging Services of Minnesota can post the presentation on their respective web sites