TDS Conductivity Probe In-Line conductivity measurement

Similar documents
BC3250. Blowdown Controller

Electronic steam boiler controls

1 of 127. Unicron Engineering ULTRASONIC TRAP TESTER UTT 100 CONDENSATE DRAIN VALVES CDV 32

INDUSTRIAL RANGE ACCESSORIES AND COMPONENTS

Adca Training. Part 2

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

Inductive Conductivity

Using the Model 1500 Portable Chilled Mirror Hygrometer

Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design)

Introduction to Flow Switch

Sitron s CF Line of Flow Switch Monitors

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

LC1350 Level Controller

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

STEAM VALVE SUPPLY & SYSTEM DESIGN

STEAM - WATER MIXERS ADCAMIX MX20

Concise catalogue Water-Industry

SECTION Pipeline Ancillaries

SECTION Boiler Controls & Waste Heat Recovery

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Rinse connection adapter CPR 40

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Installation & Operating Instructions

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

COMPACT FLAME CONTROLLER CFC 100

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Steam sterilizer AHS-75-DRY

Hydrazine Analyzer Series 2171 Specifications

Using the DewTrak II Dew Point/ Humidity Transmitter

STEAM TRAPS

HYGROPHIL H process hygrometer

Figure 1 DirectLine DL423 Sensor. Description, continued

Mobrey electronic probes

Immersion Temperature Controller

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Conductivity Electrode LRG Original Installation Instructions English

Figure 1 DirectLine DL423 Sensor. Description, continued

Condensate Monitoring OM0232

Analytical Testing for Growers. Test crucial parameters in hydroponics and greenhouse applications. hannainst.com/groline

Eclipse 90 UV Scanner Model A Version 1

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

Level gauges Series LS Level indicator, switch and transmitter for liquids

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Oxygen Sensing Solutions

The next generation thermometer from the global leader

Snifter ATEX22 VERSION. User Manual. Distributor

BOILER HOUSE PRODUCTS GMS

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.

Monitored Pneumatic Valves On Series Ported Manifold

LZT High efficiency air to water heat pumps with E.V.I. compressors

RS Pro Infrared Temperature Sensor

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Commercial Semi-Instantaneous Water Heaters

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

The A-series Eletta Flow Monitor with local indication and analog output

NEOTeCHA Reactor Sampling Type PV

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

Electro Optical Components, Inc.

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation

High Pressure Conductivity Monitor

Condensate Recovery and Return System SDR A

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

TA-Compact-P. Giving you MORE by giving you LESS

Product overview. the optimum components for every application

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

icountms Range Fluid Condition Monitoring Moisture Sensors

ECL Comfort 300 / V a.c. and 24 V a.c.

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

½ Monitored Pneumatic Valve Patented Technology

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

Danfoss gas detection units

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Danfoss gas detection unit Type GD Heavy Duty

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Constant climate chambers

SIHI Dry GD S Sizes S450, S650

Pump-Up Controller MODEL 4062

UV - flame detector dual fuel burners for intermittent burner operations

02/11/2015

Dual Pressure Controls

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Transcription:

TDS Conductivity Probe In-Line conductivity measurement (Two-pole cells with ATC Pt 100) SPS-20 DESCRIPTION The TROL SPS-20 conductivity probe is used to measure the conductivity (TDS) of the superheated water of boilers or condensate. The probe is used in conjunction with the TROL BCS controller and VPC valve series. Two-pole cells for conductivity measurement of water in steam generators or boilers. It is provided with Pt100 sensor for ATC temperature compensation in order to obtain an accurate reading of conductivity while operating with controllers provided with ATC input such as BCS-210 series. The water contains impurities in form of dissolved solids and solid in suspension whose concentration increases when it is vaporized. Water treatment can reduce impurities to a certain level but it does not eliminate them completely and in certain conditions it might even increase them. As steam starts to be produced, the concentration of total solid in suspension (TDS) increases in the boiler s water. In case the TDS concentration is too high, dissolved salts concentration will be increased. This effect can contaminate the steam and cause damage to the system due to corrosion and salts incrustation of on thermal transference surfaces, (among other problems). This high concentration is harmful and it is not acceptable in applications where steam is used for treatment of food, drinks and sterilization processes. In order to limit the concentration of TDS to a suitable level a certain amount of the water of the boiler must be periodically eliminated (purge action) and replace by treated water. SPS-20 probe together with BCS controller has been developed to purge all types of steam generators based on the measurement of TDS in the water of boiler. It activates the purge valve with a controlled cadence to avoid that an excess of purges generate energy losses and high consumption of treated water. MAIN FEATURES Cell constant K=2 Range 100 µs/cm-1 to 10000 µs/cm-1 Two-pole electrodes in SS316L Body in SS316 and PFA (PEEK in option) Pressure 25 BAR (max. 32 bar) Temperature 200 o C (max. 240 o C) Temperature compensation (ATC) by Pt100 (optional Pt1000) Calibration by buffers in the controller Compact design for piping installation Process connection DIN 43650 (IEC 4440) Resistance to vibrations:... max. 5 G RMS Protected against aggressive environments

abcde OPTIONS: Flanged or threaded probe chambers LIMITING CONDITIONS USE: AVAILABLE MODELS: SIZES: CONNECTIONS: Superheated boiler water and condensate SPS-20 DN 3/8 and DN ½ Female screwed ISO 7/1 RP (BS21) ANSI B1.20.1 (NPT) Maximum boiler pressure Maximum temperature Maximum ambient temperature Minimum distance from boiler tubes Maximum cable length (from probe to controller) Minimum conductivity Protection rating 32 bar 240 ºC 80 ºC 20 mm 20 to 30 m 100 us IP65 INSTALLATION: Horizontal or vertical installation MATERIALS DESIGNATION MATERIAL ORDER REQUIREMENTS : SPS-20 probe for TDS with Pt100 sensor for measurements up to 10000 µs/cm-1, process connection 1/2" GAS or 1/2" NPT. Body EC electrodes Insulation AISI 316L / 1.4404 AISI 316L / 1.4404 FPA (PEEK on request) WEIGHT: 0,12 Kg WEIGHT: 0,16 Kg INSTALLATION: Can be fit into a T connection or into our standard chamber providing that the probe is always in contact with the water. Any metallic parts near the probe must be at a minimum of 20mm from the central end pole. VALSTEAM

abcde FLANGED SENSOR CHAMBER (SANDWICHED DESIGN) THREADED SENSOR CHAMBER 1 Sensor chamber 2 SPS-20 Conductivy probe 3 Compression fitting for sample collection (optional) VALSTEAM

www.valsteam.com Body DN/PN Fluid Press.bar Temp.C - Temp. C + abcde FIRETUBE BOILER AND PNEUMATIC ACTUATED VALVE The VPC blowdown valve is programmed to open periodically in order to purge a certain amount of water. The BCS controller will then measure the electrical conductivity of boiler water (closed related to the TDS) and compare it with the set point selected in the controller.it close the valve after the purge if the measured value is lower, or it will keep the valve open until the measured value stay below the set point, if it is higher. To avoid energy waste due to boiler stand-by or low load, it is recommended to relate the system operation to the burner firing. It is also recommended to install a heat recovery system (flash vessel, heat exchanger, etc) before connecting the wasted water to the BEX. FIRETUBE BOILER AND ELECTRIC ACTUATED VALVE 1 Adcatrol SPS-20 TDS probe with chamber 2 Adcatrol BSC-210 TDS controller 3 Adcatrol VPC-32 Blowdown valve 4 Adca SC32SS Sample cooler 5 Adca NV-400 Needle valve 6 GV32B Bronze globe valve 7 Adca VF Bellow sealed globe valve WIRING DIAGRAM EXAMPLE OF CONNECTION CONTROLLER BCS-210 Connector DIN 43650 SPS... Pin 1 Pin 3 Pin 2 GND Output Pt100 Output Pt100 Output Pole of EC Output Pole of EC Note: Sensor chamber is rotated 90º for catalogue only. 1 ----- Power supply 85 265 V ac/dc 2 ----- optional: 12 or 24 V ac/dc 3 + 4 - RS-485 Modbus RTU communication 5 + Auxiliary power supply 24 Vdc 40 ma 6 - Common to 24 Vdc and AO1 - AO2 outputs (option) 7 + AO1 Analog output 4-20 ma of Conduct. (option) 8 + AO2 Analog output 4-20 ma of Temp. (option) 9 DO1 Blow-down output of TDS. SPST Relay 10 Common 11 DO2 Hi and Lo Limit output of EC. SPST Relay 12 13 14 ATC by Pt100 input (Pt1000 in option) 15 Without Performing input for sensors of: Polarity 16 2-poles Conductivity EC probes VALSTEAM

A D C A T RO L A DC A TR OL abcde WATER TUBE COIL BOILER PROBE INSTALLED IN THE CONDENSATE RETURN LINE The BCS controller (2) is programmed to continuously measure (1) the electrical conductivity of boiler return condensate (closed related to the TDS) and, compare it with the set point selected in the controller, it will invert the flow of the three way valve (4) from B to C if the measured value is higher, or keep the valve flow from A to B until the measured value exceed the set point. The chamber (3) guaranties that the probe (1) is always in contact with the measured medium (condensate). It is recommended to install a heat recovery system (flash vessel, heat exchanger, etc) before connecting the wasted condensate (C) to the BEX. WATER TUBE COIL BOILER PROBE INSTALLED IN THE RECIRCULATING PIPE (Condensate return) (Condensate) 20 SPS-20 Conductivity probe 21 BCS-210 TDS Controller 22 Probe chamber 23 Adcatrol PV253 3 way control valve 24 SC32 Sample cooler system Complete description: ADADGV.06.3676 VALSTEAM Pump (Please check NPSH) (TO BEX, see ADBEX.01.2839) Similar to the previous one but in this case the pump (10) is recirculating the make-up water across the probe (22).