Sentinel KalGUARD. Product Facts. Water Treatment Equipment to Manage Hard Water Limescale. Features & Benefits. Overview

Similar documents
The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel

Commercial product range

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Powerflow Unvented water heater

Product Guide Immersion Heaters & Accessories

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

For commercial & industrial systems. Large volume dirt collection capacity

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

Product Guide Immersion Heaters & Accessories

9.0 Systems For Domestic Water Installations

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018

Hotflo. Unvented point of use hot water

PRODUCT GUIDE A WATER HE ATER S ULTIMATE DEFENSE 12 YEAR WARRANTY ION POLARIZATION SCALE REDUCTION SYSTEM

PRODUCT GUIDE A WATER HEATER S ULTIMATE DEFENSE 12 YEAR WARRANTY ION POLARIZATION SCALE REDUCTION SYSTEM

marine horticulture recycling

Technical and Installation manual All Models

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Balba. Technologies Limited. An Introduction to Side Stream Filtration And the Balba Viking Product Range

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

LEAKSTOPPER RANGE Multizone water leak detection systems

THE NON-ELECTRIC MINIMAX M2 BLOCK SALT SOFTENER. Powerful, Reliable, Efficient. >>>

Eliminator TotalGuard Installation Manual

UNVENTED WATER HEATERS. Water Heater Display Stand

Please take time to carefully read through these guidelines before using your Kamco pump.

Please take time to carefully read through these guidelines before using your Kamco pump.

INSTALLATION INSTRUCTION

Please take time to carefully read through these guidelines before using your Kamco pump.

ß ß ß ß ß ß ß. Group application electronic temperature controller. Suitable for multiple shower and washing applications

Unvented Electric Water Heater 10/15 litre Undersink

Emission Monitoring System

Cistern-fed water heating

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Bath Shower Mixer

BWT WS Range Water Softener

THERMOSTATIC SHOWER CONCEALED VALVE - TWIN WITH DIVERTER & TRIPLE WITH DIVERTER

Product Catalog and Technical Specifications for DCW-Units

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Owners Manual For The Rainmaster Water Recycling System

Powerstock Storage Tank

CITY OPEN - CITY BOX from 25 to 35 kw

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)

1 VICTRIX ZEUS Superior kw I features

LEAKSTOPPER 1 Single zone water leak detection system

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Installation Information User Manual

Herz York Direct Heat Interface Unit

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

HYBRID ADIABATIC Cooling System

Broag Pressurisation equipment

ECONOBOOST EB II & EB III Compact Water Booster

6800 Design Envelope Booster. Technical overview

IC-45AV Vertical Clean Centrifuge

Direct reading flowmeters type RM

High Pressure Conductivity Monitor

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

CORREX MP Anode with external voltage source. Installation & Operation Manual

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

CT range. of shower, bathroom and whole house pumps

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Miscellaneous. TMV3 Mixing Valves. TMV3 Thermostatic Mixing Valves. Specifications. Temperature Readout. Features include:

Taps, Shower & Flush Valve Range

Installer & User Guide Effective February 2013

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Water Detection Controllers

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

BOILER HOUSE PRODUCTS GMS

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Installation & Technical Guide. Domestic & Commercial.

2020c WATER SOFTENER INSTALLATION INSTRUCTIONS. visit

SAN JUAN FRESH WATER COOLING SYSTEMS

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Installer & User Guide Effective January 2017

WASHROOM. Solutions Super fast, super efficient... UK market leaders in washroom solutions for over 45 years.

Vacuum generators VADM/VADMI

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

Water Softener Installation Guide Effective for all Softeners from our Range

NOT EVERYTHING IN LIFE IS COMPLICATED.

ADVANCE ECB ELECTRIC COMBINATION BOILER

TOSHIBA AIR CONDITIONING

SERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55

Optimal work climate with open doors. Industrial air curtains Model IndAC

Transcription:

Sentinel KalGUARD Water Treatment Equipment to Manage Hard Water Limescale Features & Benefits Provides whole system protection: Provides protection to water heaters Taps, showers and valves free of lime scale means fewer sites for hidden bacteria Heating systems are free of lime scale, reducing energy bills Safe to be included in drinking water, no need for complex plumbing to divert KalGUARD away from drinking water streams - meaning less complex installation Can be fitted to rising main, which is often smaller bore than the hot water distribution system, with resultant cost savings Metering system controls the operating parameters of the KalGUARD meaning it delivers the right amount of zinc for the intended application: Maximises life expectancy of the KalGUARD anode Provides the correct amount of protection for the intended system Complies with Part L Building Services Compliance Guide. WRAS approved. Overview Sentinel KalGUARD is an electrolytic scale inhibitor package for commercial hot water systems, an independently-proven, lowmaintenance way to protect a property against the damaging and expensive impact of limescale. Where a Sentinel KalGUARD replaces a brine water softener, a return on investment can be delivered usually within 12 months. The system is effective in all mains hard water areas found in the UK. KalGUARD is an environmentally friendly and non-polluting means of permanent water treatment. The anode is designed to be replaced after a 5-8 year service period on continuous dosing applications but can last up to 10-12 years with intermittent usage. It will protect complete H&C systems by eliminating the formation of limescale encrustation, thereby ensuring continued maximum thermal efficiency and long major equipment life. This will also assist towards compliance with carbon emission regulations. The KalGUARD system does not use any chemicals or salt, nor any temporary electrical or electronic effects. Each system kit consists of the following components: Anode Unit the zinc alloy electrode unit Controller provides low voltage DC output to the anode (< 9 V DC) Flow Meter supplies water flow data to the controller Water filters and a pulse splitter unit are also available as optional accessories to the basic kit (see details below). Page 1 of 5

Schematic System Diagram The basic elements of the KalGUARD system are illustrated below (Fig.1). Anode Unit The KalGUARD anode is plumbed directly into the main water supply to the building. It is constructed from a copper body with solid brass fittings and is therefore very robust - a bright plated finish also ensures long lasting protection. The sizing is based on individual site requirements and KalGUARD kits are available in sizes 22, 28, 35, 42, 54, 67, 76 and 108 mm, providing complete coverage. Dimensions, flow rates and other technical data can be found below in the Specification Table. Important Note: The use of delayed action ball valves, or other similar water level control systems, is strongly recommended in order to avoid trickle flow conditions which can potentially compromise the efficacy of a KalGUARD installation. Controllers Mk 1 Mk 2 Alternative controllers are supplied with the KalGUARD system, depending on the anode sizing. The Mk 1 and Mk 2 controllers both have BMS connection capability and the facility to identify / alert regarding any potential faults with the installation. The Mk 2 unit is supplied with the smaller KalGUARDs from 22 through to 54 mm, whilst the original Mk 1 controller is supplied with KalGUARDs 67, 76 and 108 mm. Page 2 of 5

The units are both mains powered (240 VAC 50 Hz Single Phase) and designed to be wall mounted near to the KalGUARD system. A special anode connection cable and full instructions are supplied with each unit. Refer to the Specification Table for details of dimensions and other technical data. Water Meter Each KalGUARD kit is supplied with a water flow meter, providing a digital signal designed to regulate the output of the KalGUARD controller. The water flow meters feature a dry dial design and are constructed with brass bodies. Dimensions, flow rates and other technical data can be found below in the Specification Table. Filter Filters are recommended in instances where there is a risk of debris entering the water supply, which is a common problem on new build installations. Manual disc filters are supplied by Sentinel as accessories to the standard KalGUARD kits. The filters are available in a range of sizes to suit the installation. All units are manufactured from robust engineering plastics to ensure that they remain corrosion free. Durable disc filter elements are used across the range - they are easily cleaned and can be immediately reinstalled after cleaning. Dimensions, weights and other technical data can be found below in the Specification Table. KalGUARD Pulse Splitter The KalGUARD Pulse Splitter is an optional accessory to the Sentinel KalGUARD system. It is designed to take an electrical feed from the KalGUARD water meter and split the signal into two separate, isolated outputs. One of the outputs is fed into the KalGUARD controller and the second to supply a separate Building Management System (BMS) in order to monitor water flow rate or water usage. It can be used with any size of KalGUARD anode and either version of controller. The Pulse Splitter can be directly mounted on standard DIN rail. See Specification Table for further details. Page 3 of 5

Anode Units Product Code KalGUARD Specification Table Diameter (Main Body) Weight (kg) Flow (l/m) Flow Connection KALG22 375 42 2.5 37 2.22 3/4" BSP Female 0.15 KALG28 450 54 3.1 64 3.84 1" BSP Female 0.13 KALG35 484 67 4.6 96 5.76 1 1 / 4" BSP Female 0.23 KALG42 505 67 4.9 142 8.52 1 1 / 2" BSP Female 0.26 KALG54 525 76 6.4 255 15.3 2" BSP Female 0.26 KALG67 650 108 16.8 423 25.38 2 1 / 2" 8 bolt DIN/ANSI Flange 0.20 KALG76 650 134 30.0 523 31.38 3" 8 bolt DIN/ANSI Flange 0.23 KALG108 650 160 37.0 1099 65.94 4" 8 bolt DIN/ANSI Flange 0.20 Flow Water Meters KG Size Water Meters (in) mm Width Height Weight (kg) Connections Qmax Qn Qmin (l/h) Max Pres. (bar) 22 3/4" 190 99 107 1.7 3/4" BSP Male 5 2.5 50 16 1 0.20 28 1" 160-260 104 115 2.6 1" BSP Male 7 3.5 70 16 1 0.35 35 1 1 / 4" 160-260 104 120 3.1 1 1 / 4" BSP Male 12 6 100 16 1 0.38 42 1 1 / 2" 200-300 125 148 5.2 1 1 / 2" BSP Male 20 10 200 16 1 0.20 54 2" 300 125 173 8.5 2" BSP Male 30 15 450 16 1 0.23 67 2 1 / 2" 200 65 200 10.1 PN16 Flanges 50 25 750 16 10 0.06 76 3 200 80 270 13.8 PN16 Flanges 80 40 1200 16 10 0.03 108 4 250 100 270 18.2 PN16 Flanges 120 60 1800 16 10 0.05 K Value (litre) Qn Qmax = Qn = Max flow (short period) nominal flow Filters For Width Height Weight (kg) Connection Diam. Average Flow (m3/h) @ 55u 1" Short 22 mm KG 158 130.0 233 1.1 25 3.15 0.11 1" Super 28 mm KG 158 130.0 340 1.42 25 4.2 0.05 1 1/2" Super 0.12 35 mm KG 200 130.0 350 1.5 40 6.3 2" Leader 42 & 54 mm KG 230 215.0 425 3.2 50 11 0.28 3" Leader 67 mm KG 742 228.0 320 6.3 90 22 0.17 4" Leader 76 mm KG 1188 319.0 445 28.8 110 42 0.05 6" Leader 108 mm KG 1188 319.0 415 30.4 160 49 0.06 Flow Page 4 of 5

Controllers Version For Width Height Depth Display Power Supply BMS Connectivity IP Rating Mk 1 67, 76, 108 mm KG 193 180 103 LCD 240 V AC Fault Alert, Optional Pulse Splitter 65 Mk 2 22, 28, 35, 42 & 54 mm KG 259 213 66 OLED 240 V AC Fault Alert, Remote Switching (on/off), Optional Pulse Splitter 65 Page 5 of 5