NVx Suspended Gas Unit Heater

Similar documents
HEM Heat Exchange Modules

NVxEA External Gas Unit Heater

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

Destratification Fans Industrial & Commercial Heating Systems

Powrmatic Control Systems Industrial & Commercial Heating Systems

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

CP+ Gas & Oil Cabinet Heater Range

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

Powrmatic PQ Electric Quartz Infrared Heaters - A Range

NVS Condensing Gas Suspended Unit Heater

CPx Gas & Oil Cabinet Heater Industrial & Commercial Heating Systems

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

PSO Gas & Oil Cabinet Heater Range

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

PRODUCT BROCHURE. SHOP-FLOOR CMMs Designed With the Shop-floor in Mind

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

Powrmatic PZN / PZN X Hot Water Heater

PT Radiant Heater Range

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

The Powrmatic Vision Range

YOUR HOME. PVC-U WINDOWS DoorS CONSERVATORIES

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

NVx Suspended Gas Unit Heater Range

Powrmatic Air Conditioning Product Catalogue. Air Conditioning

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

BENSON.... Variante3 Fired Unit Heaters...

Tallinna Lennujaam Communiaction Guidelines

Installation Instructions

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

... UDSA - UDSBD Gas fired unit heaters...

Gas-fired unit heaters for indoor installation

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

PREEVA air handling unit

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Flue & Flue Kits for NVx, VPC & NVS

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Users, Installation and Servicing Instructions

Heat Exchanger models

Exhaust Duct Design Page 1 of (C)

CPx Gas & Oil Cabinet Heater Range

Title Brief description of project Retail

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

CECx Destratification Fan

BENSON VARIANTE 2 RANGE

AMBIRAD.... Vision Radiant Tube Heating Systems...

RHC & RHCE gas fired heating coils

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

BENSON VARIANTE 2 RANGE

BENSON LINEAR RADIANT TUBE

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

A winning concept for circuit protection and connection technology. Circuit Protection you can trust

BENSON GAS UNIT HEATERS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

OUH Suspended Oil Unit Heater

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Senior Living. Security and Access Solutions. ASSA ABLOY Hospitality

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Education. Security and Access Solutions. ASSA ABLOY Hospitality

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Recessed. Air Curtain. Fig 1. Recessed air curtain

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Dear Brokis partner,

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

SCHOOL OF ENGINEERING. BSc(HONS) IN QUANTITY SURVEYING & COMMERCIAL MANAGEMENT SEMESTER 1 EXAMINATION 2015/2016 RISK AND VALUE MANAGEMENT

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

RHC GAS FIRED HEATING COILS

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Workforce. Security and Access Solutions. ASSA ABLOY Hospitality

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Gas heaters and convectors ROBUR

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

SMOKE CONTROL - NEW DIRECTIONS

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Návrh informačného a navigačného systém pre centrum mesta Bratislava, zóna Námestie SNP a Kamenné námestie a okolie

Multi-family. Security and Access Solutions. ASSA ABLOY Hospitality

Transcription:

NVx Suspended as Unit Heater Industrial & Commercial Heating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk rp RADY 2018 POWRATIC PRODUCT

INDUSTRIAL & CORCIAL & CORCIAL WAR HATIN AIR HATIN SOLUTIONS Powrmatic CPx The NVx range of gas fired warm air suspended unit heaters from Powrmatic provide efficient and cost effective Lorem The ipsum range dolor comprises sit amet, of 11 consectetur models with adipiscing outputs elit, from sed 15 do to eiusmod 140kW with tempor heaters incididunt typically ut configured labore et dolore for free magna aliqua. discharge Ut enim and ad installed minim veniam, directly quis into nostrud the space exercitation to be heated. ullamco Heaters laboris can nisi also ut aliquip be specified ex ea commodo for ducted consequat. or plant Duis room aute applications. irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. xcepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum nergy efficiency is a key consideration and to comply with the stringent requirements of rp legislation heaters as standard are arranged with high/low heat outputs with modulation an option. AS Powrmatic NVx heating solutions for a wide variety of industrial, commercial and retail buildings. 20 - ROUP H / 25 ROUP L AS NATURAL AS (20) OIL 35 SC FUL (STANDARD) 28 SC FUL (OPTIONAL) LP PROPAN (31) LP PROPAN 31 rp RADY 2018 POWRATIC PRODUCT fficiency and rp Compliance From 1st January 2018 all warm air heaters used to provide comfort for the occupants of a heated space are required to meet minimum standards of seasonal efficiency as determined by the codesign regulation (U) 2015/1188, Directive 2009/125/C - Lot 21 Tier 1. Compliance to the standard is mandatory. The calculation for seasonal efficiency takes into account air flow, temperature rise across the heat exchanger, electrical power consumption as well as the usual thermal efficiencies. NVx gas fired suspended unit heaters placed on the market after 1st January 2018 comply with the requirements of the standard. Installers and customers will note that in pursuit of increased efficiency when rp legislation is implemented NVx heaters will no longer be available in on/off configuration other than for non-personnel heating applications. For most space heating applications high/low heat output will be standard with modulation as an option. odels Available NVx F - Axial Fan Crossflow Units NVx C - Centrifugal Close Coupled Fan Units NVx V - Axial Fan Downflow Units NVx Duo - Axial Fan Bi-Directional Units NVx D - Ducted Heat odule (no fan) Lorem ipsum dolor sit amet Installation Benefits Compact in size Horizontal wall exit flue discharge option (no roof work) Suitable for either room sealed or flue only applications Interchangeable top or rear flue/combustion air spigot positions Standard models require a single phase electrical supply Peace Of ind ore than sixty years experience in warm air Two year parts and one year labour guarantee Ten-year time related heat exchanger warranty Full technical support Working With The HVAC Trade Powrmatic philosophy is to work in partnership with our customers establishing a long-term commitment to a relationship based on understanding the expectations of customers and a dedicated common goal. By working with our customers we can deliver solutions that enable them to meet technical and regulatory challenges they face, fulfil their clients needs effectively and economically, and gain a competitive edge. Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. 2

TYPICAL APPLICATIONS TYPICAL APPLICATIONS Warehouses Factories arage Workshops Distribution / Logistic Centres Centres Horticultural & arden Centres Aircraft Hangers Showrooms Retail Outlets Construction The heater is of unitary construction and provided with a separate burner compartment with a full width hinged and lift-off door giving easy access to heater function controls, gas valve and burner. The cabinet is finished with durable epoxy powder coat stove baked paint. Heat xchanger Four pass tubular assembly manufactured from aluminised steel formed, swaged and expanded without recourse to stress inducing welding. 409 and 316 grade stainless steel options available. Burners ulti in-shot burners matched to each tube assembly and manifolded to a common gas valve and ignition system, itself complete with flame monitoring and safety controls and supplied ready for use with natural gas (20). Alternative LP propane (31) firing available to order. Air ovement Axial fan heaters are (dependent on model) fitted with either single or twin fan sets and discharge warmed air directly into the heated space via adjustable horizontal louvres. Vertical louvres are available as an option where lateral air discharge is a requirement. The NVx Duo discharges air in two directions, significantly enhancing the effective coverage of the heater, often a problem in modern well insulated buildings, offering a potential saving on both capital and installation costs. Controls As standard NVx heaters are supplied with approved safety controls including high limit protection, flame monitoring and multiple try ignition. For comfort and fuel efficiency connection terminals are provided for independent time, temperature and fan only control. Alternatively we recommend that heaters be connected to compatible Powrmatic digital control systems - C200 (control of single units) C300 ulti (control of multiple units) Note: Interconnecting wiring for all controls is the responsibility of the installer. Approvals NVx heaters are type tested and C approved. In addition heaters placed on the market subsequent to 1st January 2018 meet the seasonal efficiency requirements of rp Lot 21 Tier 1. Centrifugal fan models benefit from a close coupled fan which discharges warmed air via a duct outlet spigot suitable for the onward connection of ductwork. A comprehensive range of accessories are available. CUSTOR BNFITS CUSTOR BNFITS nergy efficient Range of sizes and configurations Lcon sectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore Space et saving dolore off-floor magna location aliqua. Duis aute irure dolor in reprehenderit in voluptate Colour velit (RAL) esse options cillum Lorem ipsum dolor sit amet, anufactured consectetur in the United adipiscing Kingdom elit, Lcon APPROVD sectetur PRODUCTadipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. 3

Technical Specification odel 15 20 25 30 40 50 60 75 90 120 140 Output (nominal) High Fire (ax) kw 15 20 25 30 40 50 60 75 90 120 140 Low Fire (in) kw 11 14 18 21 28 35 42 53 63 84 98 NVx F / C / V m 3 /s 0.42 0.56 0.78 1.06 1.18 1.51 1.86 2.56 2.81 3.56 3.75 Airflow Volume Airflow Throw Fan Static Supply Duo m 3 /s N/A N/A N/A N/A N/A N/A N/A N/A 2.34 3.12 3.64 in m 3 /s 0.42 0.56 0.78 1.06 1.18 1.51 1.86 2.56 2.81 3.56 3.75 NVx D ax m 3 /s 0.46 0.62 0.86 1.16 1.30 1.67 2.02 2.81 3.09 3.91 4.13 NVx F m 10.0 14.0 20.0 24.0 28.0 30.0 30.0 32.0 34.0 36.0 38.0 NVx Duo m N/A N/A N/A N/A N/A N/A N/A N/A 60.0 60.0 64.0 NVx C Pa 220 320 220 220 150 250 250 250 180 290 250 Standard V/ph/Hz 230/1/50 Optional V/ph/Hz 400/3/50 (Centrifugal Unit Only) 3ph units shown in brackets ( ) lectrics NVx F Run Current amp 0.50 0.53 0.56 1.0 1.0 1.7 2.6 2.6 3.40 5.2 5.2 NVx C Start Current amp 5.0 8.5 13.3 13.3 18.0 26.3 29 (16.5) (18.0) 31.0 40 (14.9) 44 (16.8) Run Current amp 2.0 3.1 4.2 4.3 5.8 7.6 10 (4.8) (5.3) 12.8 17(4.6) 20 (4.9) Connection BSP/Rc ¾ Fuel ounting Height Overall Dims Install Clearance inimum Inlet Pressure Consumption NVx F/Duo Crossflow NVx V Downflow NVx F NVx F Nat as mbar 20.0 LP mbar 37.0 Nat as m 3 /h 1.75 2.33 2.91 3.49 4.66 5.71 6.93 8.52 10.32 13.60 15.77 LP m 3 /h 0.65 0.90 1.13 1.33 1.78 2.21 2.68 3.33 4.01 5.44 6.20 in m 2.5 3.00 ax m 3.0 5.00 in m 3.00 4.00 4.00 5.00 6.00 6.00 ax m 3.00 6.00 7.00 8.00 10.00 12.00 Height mm 540 540 540 760 760 912 760 912 831 975 1140 Width mm 1000 1000 1000 1000 1000 1000 1325 1325 1950 1950 1950 Depth mm 892 925 925 925 905 925 941 941 925 941 941 Top mm 200 LH Side mm 200 RH Side mm 1000 Rear mm 400 Diameter mm Ø 80 80 80 100 100 100 130 130 130 130 130 Flue ax Length Flue Only m 12 Room Sealed m 6 Combustion Air Spigot mm Ø 80 80 80 100 100 100 130 130 130 130 130 Noise Levels Nett Weight NVx F db(a) 54 52 53 54 58 61 62 62 66 67 67 NVx V db(a) 64 62 63 64 68 71 72 72 76 77 77 NVx F kg 71.5 71.5 72.5 75.5 115 133.5 135.5 157 202 238 286 NVx C kg 106.5 120.5 126.5 166.5 168.5 183 213 234 329 363.5 430 Notes: Fuel Consumption and output figures based upon nett calorific values as follows: - Natural as (20) nett CV 34.02 J/m 3 - LP Propane (31) nett CV 88.00 J/m 3 NVx heaters have efficiency levels which comply with the requirements of United Kingdom Part L Building Regulations and the seasonal efficiency requirements of the codesign regulation (U) 2015/1188, Directive 2009/125/C Lot 21 Tier 1 (Known as rp and mandatory as from 1st January 2018) Air handling data is assessed at room ambient conditions Throw figures provide the distance to the point where the terminal velocity degrades to 0.25m/s The NVx Duo throw dimension is the effective combined throw measurement. Dimensions and clearance data in the table above refer to NVxF units only - for all other model data refer to the dimensions page and/or the installation, operation and maintenance manual. Noise levels are applicable to standard NVx F models and are measured 5m from appliance in a typical installation situation. otor, run and start amps apply to standard electrical supply as stated. For optional data contact sales office. Where NVxD heaters are to be applied installers should be aware of both the minimum and maximum airflows as well as a need for fan over-run facilities to protect the heater. It is recommended that you consult with Powrmatic Technical Support prior to product selection and installation. For extended combustion duct lengths measurement please contact Powrmatic Technical Support For Installer guidance notes see page 11. 4

Dimensions NVx F - Axial Fan Crossflow NVx 40F NVx 90F L ØD C F P A FRONT VIW 35 B Q N AS NTRY POINT LC NTRY R/H SID VIW RAR VIW SUSPNSION POINTS 10 K J H K J J H PLAN FOR NVx F 15-75 PLAN FOR NVx F 90-140 odel 15 20 25 30 40 50 60 75 90 120 140 A mm 1000 1000 1000 1000 1000 1000 1325 1325 1950 1950 1950 B mm 700 700 700 700 700 700 700 700 700 700 700 C mm 540 540 540 760 760 912 760 912 831 975 1140 DØ mm 80 80 80 100 100 100 130 130 130 130 130 mm 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 F mm 308 308 308 492 492 644 416 568 487 631 796 mm 120 120 120 142 142 142 220 220 220 220 220 H mm 317 317 317 317 317 317 347 347 347 347 347 J mm 450 450 450 450 450 450 700 700 2 x 662.5 2 x 662.5 2 x 662.5 K mm 218 232.5 232.5 232.5 232.5 232.5 278 278 278 278 278 L mm 892 925 925 925 925 922 939 985 922 941 941 mm 216 216 216 206 206 206 236 236 246 246 246 N mm 114 114 114 114 114 114 145 145 88 88 88 P mm 194 194 225.5 297 297 374 297 374 326 398 481 Q mm 157 190 190 190 170 190 204 250 188 207 207 5

Dimensions NVx Duo - Axial Fan Bi-Directional Units NVx 90 Duo L C A FRONT VIW B R/H SID VIW Q SUSPNSION POINTS 10 F P PLAN N AS NTRY POINT LC NTRY RAR VIW K J J H odel 90 120 140 A mm 1950 1950 1950 B mm 700 700 700 C mm 831 975 1140 DØ mm 130 130 130 mm 235.5 235.5 235.5 F mm 487 631 798 mm 220 220 220 H mm 347 347 347 J mm 2x662.5 2x662.5 2x662.5 K mm 278 278 278 L mm 1287 1350 1350 mm 246 246 246 N mm 88 88 88 P mm 326 398 481 Q mm 188 207 207 6

PLAN FOR NVx F 15-75 PLAN FOR NVx F 90-140 Dimensions NVx V - Axial Fan Downflow Units NVx 60V ØD L B+70mm 1325 FRONT C R/H SID VIW A RAR K J J H N DROP ROD SUSPNSION POINTS 10 LC NTRY K J J J H N LC NTRY P F P F C+30mm AS NTRY POINT C+30mm AS NTRY POINT PLAN FOR NVx D 10-75 PLAN FOR NVx D 90-140 odel 15 20 25 30 40 50 60 75 90 120 140 A mm 1000 1000 1000 1000 1000 1000 1325 1325 1950 1950 1950 B mm 700 700 700 700 700 700 700 700 700 700 700 C mm 540 540 540 760 760 912 760 912 831 975 1140 DØ mm 80 80 80 100 100 100 130 130 130 130 130 mm 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 F mm 308 308 308 492 492 644 416 568 487 631 796 mm 120 120 120 142 142 142 220 220 220 220 220 H mm 283 283 304 283 283 283 312 312 319 319 319 J mm 260 260 260 260 260 260 385 385 460 460 460 K mm 197 197 197 197 197 197 243 243 251 251 251 L mm 892 925 925 925 905 925 939 985 986 986 986 mm 216 216 216 206 206 206 236 236 246 246 246 N mm 114 114 114 114 114 114 145 145 88 88 88 P mm 194 194 225.5 297 297 374 297 374 326 398 481 7

Dimensions NVx C - Centrifugal Close Coupled Fan Units NVx 50C (Front) NVx 50C (Rear) ØD C T F P S A B 35 L N AS NTRY POINT LC NTRY FRONT VIW R/H SID VIW RAR VIW SUSPNSION POINTS 10 PLAN K J H PLAN FOR NVx F 15-75 K J J H PLAN FOR NVx C 90-140 odel 15 20 25 30 40 50 60 75 90 120 140 A mm 1000 1000 1000 1000 1000 1000 1325 1325 1950 1950 1950 B mm 700 700 700 700 700 700 700 700 700 700 700 C mm 540 540 540 760 760 912 760 912 831 975 1140 DØ mm 80 80 80 100 100 100 130 130 130 130 130 mm 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 F mm 308 308 308 492 492 644 416 568 487 631 796 mm 120 120 120 142 142 142 220 220 220 220 220 H mm 317 317 317 317 317 317 347 347 347 347 347 J mm 450 450 450 450 450 450 700 700 2x662.5 2x662.5 2x662.5 K mm 218 232.5 232.5 232.5 232.5 232.5 278 278 278 278 278 L mm 1317 1356 1356 1430 1430 1430 1505 1505 1430 1505 1505 mm 216 216 216 206 206 206 236 236 246 246 246 N mm 114 114 114 114 114 114 145 145 88 88 88 P mm 194 194 225.5 297 297 374 297 374 326 398 481 S mm 637 637 637 637 637 637 932 932 1557 1557 1557 T mm 492 492 492 712 712 864 712 ØD 864 783 927 1092 8

PLAN FOR NVx F 15-75 PLAN FOR NVx C 90-140 Dimensions NVx D - Ducted Heat odule NVx 50D (Front) NVx 50D (Rear) L ØD C T T F P S A FRONT VIW 35 B R/H SID VIW 35 N S AS NTRY POINT LC NTRY RAR VIW SUSPNSION POINTS 10 K J H PLAN FOR NVx D 15-75 K J J H PLAN FOR NVx D 90-140 odel 15 20 25 30 40 50 60 75 90 120 140 A mm 1000 1000 1000 1000 1000 1000 1325 1325 1950 1950 1950 B mm 700 700 700 700 700 700 700 700 700 700 700 C mm 540 540 540 760 760 912 760 912 831 975 1140 DØ mm 80 80 80 100 100 100 130 130 130 130 130 mm 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 F mm 308 308 308 492 492 644 416 568 487 631 796 mm 120 120 120 142 142 142 220 220 220 220 220 H mm 317 317 317 317 317 317 347 347 347 347 347 J mm 450 450 450 450 450 450 700 700 2x662.5 2x662.5 2x662.5 K mm 218 232.5 232.5 232.5 232.5 232.5 278 278 278 278 278 L mm 835 835 835 835 835 835 835 835 835 835 835 mm 216 216 216 206 206 206 236 236 246 246 246 N mm 114 114 114 114 114 114 145 145 88 88 88 P mm 194 194 225.5 297 297 374 297 374 326 398 481 S mm 637 637 637 637 637 637 932 932 1557 1557 1557 T mm 492 492 492 712 712 864 712 864 783 927 1092 9

Flue Arrangements Room Sealed & Flue Only Flue Systems Room Sealed - Horizontal Flue System Flue Only- Horizontal Flue System Combustion air entry (fitted with inlet grille) Flue socket Lengths Single to twin adaptor Terminal Flue socket Adjustable length Lengths Terminal Combustion air duct Combustion air entry (fitted with inlet grille) Adjustable length Combustion air socket 6m maximum 12m maximum Room Sealed - Vertical Flue System Flue Only- Vertical Flue System Terminal Terminal Flashing Flashing 12m maximum Single to twin adaptor 6m maximum Lengths Adjustable length Lengths Adjustable lengths Combustion air entry (fitted with inlet grille) Condensate drain length Condensate drain length Flue socket Combustion air socket Flue socket Combustion air entry (fitted with inlet grille) Notes: The following notes are for guidance purposes. Installers should refer to the Installation, Operation and aintenance manual prior to commencing installation Where heaters are installed in room sealed mode the maximum flue run is 6 metres. For flue only installations the maximum flue run is 12 metres. 45 bends may be used if required. For each bend the maximum flue length is reduced by 0.5 metres per bend 90 bends should be avoided if possible. Where bends are used the maximum flue length is reduced by 1.0 metres per bend Where NVx heaters are installed in clean environments and where the combustion air ventilation requirements allow it is possible to take combustion air directly from the installed space. In such cases the combustion air entry grille must be fitted. Where NVx heaters are installed with a vertical flue it is recommended to install a condensate drain length 10

Your Installer uide eneral The following notes are provided as a guide, however installers and users should fully acquaint themselves with the more detailed guidance provided in the relevant Installation, Operation and aintenance anual. For copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Standards NVx heaters must be installed, commissioned and operated with due regard to appropriate regulations including but not limited to BS6230:2011, relevant Codes of Practice, the possible requirements of Local Authorities, Fire Officers and insurers as the relevant Installation, Operation and aintenance anual. Position & Location Powrmatic NVx heaters can be drop rod suspended via purpose designed 10 suspension fixing points, attached to our optional wall support brackets or positioned on a level non-combustible base. In all cases it is important that all supporting structures have due regard to the relevant weight loadings. Consideration should also be given to flue routes and points of exit, gas, electrical and control connections, the throw characteristics of the heater, issues of public access and the siting of environmental control stations and/or remote temperature sensors where the position needs to be representative of the zone temperature to which they refer. Heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn into the combustion air or main fan circuits. Areas where special consideration or advice may be required could include but is not limited to - Where de-greasing solvents are present, even in minute concentrations Where paint spraying is carried out Where styrenes or other laminating products are used Where airborne silicone is present Where petrol engined vehicles are stored or maintained Where dust is present (i.e. wood working or joinery shops) Where high levels of extract persist Installation in such areas may be possible under specific conditions. Please consult our technical department or your local sales manager for further information. Plant Room or nclosure Locations Specific requirements exist where heaters are to be installed in a plant room or enclosure. Such requirements include the provision of positive ductwork connections as well as ventilation for combustion air and general ventilation. It is recommended that you consult with our technical department or your local area sales manager for further guidance. Installation Clearances Particular clearances may be necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant Installation, Operation and aintenance anual. Combustion Air & eneral Ventilation Within the United Kingdom mandatory regulations apply concerning the provision of combustion air and general heater ventilation. Where a heater is installed in room sealed mode (i.e. where both the flue exit and combustion air are positively connected to atmosphere) then there is no specific requirement for combustion air ventilation. However, depending upon location, provision for general ventilation may still be a necessity. If the heater is installed in flue only mode and directly within the heated space and where that heated space has a natural ventilation rate greater than 0.5 air changes per hour then combustion air and general heater ventilation is probably not required. If the heated space has a natural ventilation rate of less than 0.5 air changes per hour then either natural ventilator openings or mechanical ventilation will be required. Please consult the Installation, Operation and aintenance anual for further details. Flue NVx heaters can be installed in either room sealed or flue only mode. ach heater requires a separate flue and/or combustion air intake syst em of the appropriate size and type. Installers are reminded that type approval has been granted for these appliances on the basis that they are fitted with Powrmatic NVx flue systems. aximum lengths apply and should be strictly observed. Systems may be installed in either the horizontal or vertical plane. In either case the number of bends kept to a minimum and regard must be given to the reduction in permissible length with the addition of each bend. The flue must be adequately supported and terminated with the approved terminal assembly, with due regard to the point of exit and it s proximity to any windows, doors or ventilation intakes. Pipework Care should be taken when sizing pipe work to ensure that minimum gas inlet pressures are not compromised under dynamic load conditions. Isolating valves and service unions should be provided for each heater and pipe work installed with due regard for relevant standards and Codes of Practice. Ductwork NVx heaters can be fitted with distribution ductwork and/or inlet or return air duct connections. In such circumstances the NVx C centrifugal fan model should be selected and installers must ensure that the combined duct resistances, including grilles, filters, dampers or other ductwork components are balanced to closely match the static pressure as shown on page 4 of this brochure. Insufficient or excessive duct resistance will compromise the performance of the heater. Please consult or technical department or your local area sales manager for further guidance. uarantee Powrmatic NVx heaters are provided with a comprehensive guarantee covering both the heater and the heat exchanger. For United Kingdom sales the heater has the benefit of a two year parts and one year labour guarantee whilst the heat exchanger assembly has a ten year time related warranty. All guarantees are subject to terms and conditions. 2 YAR PARTS WARRANTY 1 YAR LABOUR WARRANTY 11 10 YAR TI RLATD HAT XCHANR WARRANTY

Powrmatic are a leading British manufacturer of industrial and commercial heating equipment. With over 60 years of experience in the HVAC industry, our products are built with integrity, and characterised by high quality and energy-saving designs, delivering exceptional performance and facilitating compliance with energy and emission regulations. Powrmatic are also a specialist British manufacturer of natural, powered and smoke ventilation products working closely with a wide range of architects and consultants whilst also a supplier of a range of air conditioning and evaporative cooling equipment. We provide a full product application advice service for architects, mechanical engineers, installers and end users to ensure the best products are selected to meet the required budget, design and regulatory requirements. Our heating and ventilation engineers are also supported by distribution partners and a network of installers who are knowledgeable in the supply, installation and maintenance of all of our equipment. et in touch United Kingdom Office Powrmatic Limited Hort Bridge Ilminster Somerset TA19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk Ireland Office Powrmatic Ireland 45 Broomhill Close Tallaght Dublin 24 tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie FOR TH LATST NWS, CAS STUDIS, AND TCHNICAL SUPPORT FOLLOW US ON #keepingthenationwarm ICO nergy Association URO-AIR QUALITY Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. Issue 6.1 rp 2018