Rotorua NOW Home: A collaborative project

Similar documents
Retrofit of a 1950s State House

Rotorua NOW Home Final Performance Monitoring

ENERGY ASSESSMENT REPORT For Mrs Right, Energy House Rightsborough, New Zealand

Homestar Home User Guide

Healthy Homes Standards

property report Josh s House Living Key: enhancing prosperity and quality of living

Riverdale NetZero Project Summary of Costs and Expected Performance

GBCSL Presentation, Colombo

THE BUSINESS OF ARCHITECTURE

TIPS FOR A WARMER, HEALTHIER HOME

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

- Murdoch University, Western Australia.

Design and siting guidelines

SOLAR PASSIVE DESIGN CASE STUDY K & D S HOME

At Hotondo Homes, we believe your home is your retreat

Adelaide Homes Design Guide 4 - Winter warming

3625 Westcliff Way SW

the STABLES Passive House Certifi cation Pending 3 bedrooms + offi ce / 4th bedroom 3 full bathrooms /- sq ft of living space

Energy Efficiency Rating

Hot water This guide will help you choose the right hot water system for your home and show you how to reduce your hot water costs.

Damp, Mould and condensation. The Facts About

Construction standards and qualities

Repairs: Frequently Asked Questions

Sustainable Systems Report

STUDY REPORT SR 287 (2013) New House Owners Satisfaction Survey MD Curtis

OPEN DAY 20 AUGUST 10am - 3pm

HEATING - the largest part p your home's energy bill

Condition Report Residential Tenancies Act 1997 CONDITION REPORT. Address 35 Sample Street, Tarneit Vic Tenant(s) Initials

Many cylinders maintain far more hot water in reserve than is usually required.

Deceptively minimalist

Have you chosen a building style? Pueblo, Territorial, or Northern New Mexico or a combination thereof?

Project Name: Ebico Trust Caseworker

Renovation Case Study From 1 to 7 Stars Making a home comfortable and efficient to run

FLORIDA HOUSING COALITION 24 th Annual Conference September 27, 2011

Condensation in your Property. A Homeowners guide to. A guide to the causes and how to remedy the problem

Your guide to condensation and how to reduce it. Come home to comfort

Waterwise Rainwater Saving Guide

Eco Retrofitting Your Home. don t panic!

Internal Fixtures & Features#

Energy Efficiency Rating

At Hotondo Homes, we believe your home is your oasis

UPGRADES. [Energy Efficiency] Base Points

Domestic Green Deal Advice Training

Rebates for New Houses. Solar Hot Water Systems (SHWs) & Small Generation Units (SGUs) Federal Government

HomeSmart Renovations

TOWNHOME STANDARD INCLUSIONS

Deluxe Inclusions. Harrington Homes reserves the right to change designs and inclusions without notice.

south-west the bourke H O M E S your home, your choice

Making Your Home HomeSmart a homeowner manual

Contents. General appliance information

Heating choices and costs for Christchurch

Date of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number:

Energy-saving tips. Energy-saving tips For your home. For your home. part of your home. save energy in every. and ideas to help you

Smart Growth Development Checklist


Homeowner s Guide: Being Energy Efficient

Condensation on Your Windows?

Fixing the Pretty Good House. Marc Rosenbaum, P.E. South Mountain Company West Tisbury, MA

Safe Heating in Sheltered and Social Housing

Residential Monitoring to Decrease Energy Use

Enlightened Fresh Air For a Healthy House

Controlling Condensation and Mould

SL-1 Passive Solar, Ventilation & Shading Design

Your comprehensive guide to: Condensation & Mould Growth

Energy Efficiency Rating

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

Energy and Water Conservation. Workshop for ELSA 3

Owners Manual For The Rainmaster Water Recycling System

Green Living Guide - Students

Building smart. communities.lendlease.com

Kills bills. How Vaillant technologies reduce home heating bills

your home: Damp, condensation & mould

PRODUCTS & SERVICES 2006

report prepared for 5 Bedroom Victorian House, Widcombe version BEDROOM VICTORIAN HOUSE, WIDCOMBE

SmartRad Planning Manual

NANO LIVING NANO TERRACE FINISHES SPECIFICATION

Chifley Passive House: Two years of performance data Harley Truong 1 and Andrew Garvie 2 November 2016

Stevenage Borough Council standard for letting empty homes (the Lettable standard)

10 smart ways to live sustainably

A 92 plus B C D E 39-54

Air conditioners are the biggest source of electric use in the summer. In many homes, it will account for more the ½ of your electric bill.

ENVIRONMENTAL STRATEGY FOR ROW HOUSE- CAPE TOWN

gaps between walls or ceilings and cornices fixed air conditioners and heaters construction joints between wall materials

COST EFFECTIVE PASSIVE SOLAR FOR NEW HOME CONSTRUCTION

GREEN TIPS SAVE MONEY, SAVE THE ENVIRONMENT

Ph: (907) Quality Homes

Pasture Road, Goole DN14 6EZ Offers over 180,000

17 Good Shepherd Court, Ayr, KA8 0RR

30 MAURICET LANE Wren Model at Craggy Park Lot 13

Energy consumption in properties

How to save energy around the home. Remember The cheapest energy is the energy you don t use

Meaco 10L small home dehumidifier Instructional Manual

SUNNY LANE TERRACE HOMES

A guide to. e Condensation. and how to reduce it

ENERGY PERFORMANCE SCORE

The Energy Center. Energy Efficiency. from the others.

Modern Exteriors Stylish Kitchens Designer Bathrooms Comtemporary Living Fixtures & Finishes Schedule Inclusions Brochure

House and Land Package Plus NEW CAR* $651,500

05/2017

SELF-CONTAINED STUDIO SPECIAL

Transcription:

Rotorua NOW Home: A collaborative project Lois Easton, Homes Research Team Leader

Outline of Presentation 1. Rotorua NOW Home research questions 2. Waitakere NOW Home vs Rotorua NOW Home design & construction 3. Key results from monitoring 4. So what does this tell us?

Rotorua NOW Home Research Questions Can we take what we have learned from the Waitakere NOW Home design & construction, and translate that so that a third party (HNZC) can achieve similar outcomes in a different climate? Have we got it right? Are the key features of the Waitakere NOW Home workable in other circumstances?

Rotorua vs Waitakere Design & Construction Process Waitakere NOW Home Rotorua NOW Home Climate Zone 1 Climate Zone 2 Designed to meet Beacon requirements Designed to meet HNZC requirements with NOW Home overlay Beacon team had control over design APR independent architect designed, with input from Beacon & HNZC On-site Beacon project manager APR project managed Built by GJ Gardner using a modified GJ Gardner specification Built by independent builder using APR generated specification

Similarities Between the Homes Aspect Size Floor Plan Thermal Mass Hot Water System Water System Rainwater reuse Waste Lighting Paints, adhesives & finishes Lifetime Design Landscape treatment Common Attribute Modest size (141-146m 2 ), 3 bdrm house, with single garage North oriented living spaces with optimum eave widths for passive solar gain North facing insulated concrete slab Solar hot water system sub optimal panel orientation Low flow taps and fittings Rainwater supplying laundry and toilet Strong focus on reduced construction waste and diversion from landfill with relatively good success Energy efficient bulbs used Environmental Choice certified products used wherever available Accessibility design principles used Vegetable garden, composting and outdoor clothes drying

Differences Between the Homes Aspect Waitakere NOW Home Rotorua NOW Home House form House Materials Floor Plan Simple form with pitched roof & conventional guttering system. Wooden weatherboard cladding, concrete tiled roof Bedrooms on eastern side 1 bathroom disabled access, laundry in garage No corridors bedrooms located off second living area More complex design, butterfly roof & internal gutter Shadowclad ply & Colorsteel cladding, Colorsteel roof Bedrooms on western side 2 bathrooms one disabled access, separate toilet, separate laundry Bedrooms separate from living areas down corridor which faced onto deck Draught lobby included at entrance. Main entry into living area Ventilation Openable windows & rangehood, mechanical bathroom ventilation & passive kitchen ventilation system added later Mechanical ventilation in kitchen and bathrooms, passive vents in living areas Heating No fixed heating system provided 10 kw pellet burner in family room Costs $220,000 + GST Budget $180,000 + GST

North

North

Differences Between the Homes Aspect Waitakere NOW Home Rotorua NOW Home Rainwater Tank Whiteware Lighting Above ground tank 13,500 litres with manual change-over to/from town supply. Rainwater also supplying hot water system Energy and water efficient whiteware supplied as part of tenancy Suspended lighting system, CFLs throughout Below ground rainwater tank, 4000 litres with automated controller to manage switch between town & tank supply Tenants supplied own whiteware older Combination suspended CFLs and halogen downlights, Tenants 4 person moderate income family 5 person low income family Monitoring Insulation Intensive monitoring system with every circuit and tap monitored High insulation levels specified and used throughout Cut down monitoring system High insulation levels specified however, lower spec insulation installed Thermal Mass Thermal mass contributed significantly Thermal mass covered by carpet and to keeping the home warm unable to contribute to retaining warmth in the home

Monitoring Results - Energy Used 6900 kwh in Year 1 and 6500 kwh in Year 2 Lower than Waitakere NOW Home and met HSS -2008 benchmark despite being a 5 person household Solar water heater was the largest electricity end use 41% of electricity, and was generally a poor performer with a COP of 1 Lighting was a high user in Year 1 but dropped back in Year 2 Water pump was a relatively high user 5%

Electricity End Uses 6900 kwh 6500 kwh 7000 ) h W (k e s U ity tric c le l E a u n A 6000 5000 4000 3000 2000 1000 3% 5% 12% 5% 21% Unassigned 29% 2% Jug (Y1) 5% Microwave (Y2) 3% 1% 1% 7% Pellet Burner Control 5% 2% TV 6% Fridge Water Pump 6% Range Lights 41% Solar Water Heating 42% 0 Year 1 Year 2

Monitoring Results - Water Rainwater system performed very well in Year 1 57 litres/pp/day average use lower than Waitakere NOW Home & HSS -2008 benchmark In Year 2 the Rainbank failed and all water was provided from town supply with average 200 litres/pp/day Occupancy dissatisfaction with flow rates of showers low low flow

Monitoring Results - IEQ Average evening living room temperature of 17.5 C, slightly below the 18 C HSS -2008 benchmark Overnight bedroom temperatures were still poor - average winter temperature in the master bedroom was 12.9 C, considerably cooler than the 16 C recommended in Beacon s HSS. RH levels were good in the living areas - evening winter humidity levels averaged 58% RH RH levels in bedrooms were higher- master bedroom overnight average of 69% RH & bedroom 3 overnight average of 72% RH

Performance of thermal envelope Heating required every day over winter and pellet burner even used a couple of days in December Didn t perform as well thermally as anticipated because of a combination of design, user behaviour and construction error In particular Below spec ceiling insulation installed HERS rating of 5.5 stars vs 6 for Waitakere NOW Home Concrete thermal mass covered by rugs

Performance of the heating system Pellet burner seen as a good way to manage heating costs for fixed low income household Was mainly used in afternoon and evening little morning and overnight use Size of pellet burner (10 kw) meant that whole house should have been able to be heated to healthy temperatures. However, distance to the bedrooms and lack of heat transfer meant that bedrooms were effectively unheated. Under-heating may also be a factor cost, user expectations

Pellet Burner Use 100 80 60 40 Pellet Burner Average Electrical Energy over Winter (W) 20 0 00:00 03:00 06:00 09:00 12:00 15:00 18:00 21:00 00:00 Time of day

Dampness and Condensation Dampness and condensation weren t problems in the home and cold temperatures were the cause of the elevated relative humidity in the bedrooms Cedar louvres assisted in lowering relative humidity levels in living areas Mechanical extract ventilation eliminated any moisture from wet areas

Performance of the Water System Total per person water use was relatively high (200 litres/pp/day cf 189 pp/day in Waitakere) Rotorua year-round rainfall meant a smaller tank (4000 litres) was able to supply most (72%) of household needs. This compares with 60% of water use provided by a 13,500 litre tank at Waitakere When working, the controller was effective at optimising water sources but had quite a high power demand (5% total electricity) Insufficient flow rate meant occupants had a poor level of service

So what does this tell us? Some of the outcomes were better and some were worse than the Waitakere NOW Home The biggest issues seem to have arisen as a result of the more complex design, insufficient regard for the colder climate, and occupancy behaviour Additional design criteria and specifications are required to ensure these issues don t occur in future homes. These include, for example: Alternative methods to achieve thermal mass Better specification around heating and the need for heat transfer

What next for New Homes? Design criteria and specifications developed for future HomeSmart Homes, taking into account learnings from both NOW Homes Support information Homeowner Manual, Best Practice Guide also developed Information will be published on the Beacon website as well as plans and specifications for the Waitakere NOW Home Aim to gain DBH building consent for national multiple-use of Waitakere NOW Home design so design can be easily used around NZ

Project Partners and Suppliers