Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Similar documents
Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

TECHNICAL SPECIFICATIONS

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

FG7T (C and L Series)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Multi-Position Gas Furnaces

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

TECHNICAL SPECIFICATIONS

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Comfort, Quality and Efficiency.

Ruud Achiever Plus Series Multi-position Gas Furnaces

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

MULTI POSITION GAS FURNACE

GMS9/GCS9 SERIES 93% AFUE

RG7D 1-Stage Heat Series

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

13 GEP A L P - 1 A

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

MERIT SERIES Downflow

MULTI POSITION GAS FURNACE

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

Rheem Classic Series Multi-position Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

RGE 13 A T - 1 A

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

Ruud Achiever Series Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Cooling Capacity CFM in. w.c. (125 Pa)

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Rheem Classic Plus Series Multi position Gas Furnaces

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Transcription:

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace TDD-D- XB 80 TUEA00A92A, TUEA060A92A, TUEA060A936A TUEB060A936A, TUEB080A936A, TUEB080A98A TUEB00A936A, TUEC00A98A, TUEC00A960A TUEDA960A, TUED0A960A Single-Stage Fan Assisted Combustion System PUB. NO. 22-666-07

General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. BURNERS burners will give years of quiet and efficient service. All models can be converted to L.P. gas. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. AIR DELIVERY The -speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING Heavy gauge steel and wrap-around cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Alternate bottom, left or right side return air connection provision capability. FEATURES AND GENERAL OPERATION The XB 80 High Efficiency Gas Furnaces employs an system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. Trane 09 2 Pub.. 22-666-07

Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUEA00A92A TUEA060A92A TUEA060A936A TUEB060A936A TUEB080A936A TUEB080A98A TUEB00A936A TUEC00A98A TUEC00A960A TUEDA960A TUED0A960A Performance Data Electrical Data Field Wiring Dimensions 2 6 9 7 Pub.. 22-666-07 3

Features and Benefits XB 80 STANDARD EQUIPMENT Convertible to horizontal left or right Power supply Single speed venter Hot surface igniter Integrated system control Attractive color accents Heavy gauge aluminized steel heat exchanger drive -speed motor Blower door safety switch Multiport In-shot burners Complete front service access Alternate bottom/left/right return air in vertical position Slide out blower assembly Common vent capability Heavy gauge reinforced wrap-around steel cabinet Super quiet performance Optional L.P. conversion kit Left/right gas connection Pub.. 22-666-07

Features and Benefits ACCESSORIES FOR XB 80 OPTIONAL EQUIPMENT (Check mark [ ] indicates accessories included). For Comfort Controls, See price book pages... [ ] CleanEffects TM Whole House Air Cleaner (-" Wide, Upflow / Side Return Furnace)... TFD5ALFR000A [ ] CleanEffects TM Whole House Air Cleaner (7-" Wide, Upflow / Side Return Furnace)... TFD75ALFR000A [ ] CleanEffects TM Whole House Air Cleaner (2" Wide, Upflow / Side Return Furnace)... TFD20ALFR000A [ ] CleanEffects TM Whole House Air Cleaner (2-" Wide, Upflow / Side Return Furnace)... TFD25ALFR000A [ ] CleanEffects TM Whole House Air Cleaner (-" Wide, Downflow Furnace)... TFDDALFR000A [ ] CleanEffects TM Whole House Air Cleaner (7-" Wide, Downflow Furnace)... TFD7DALFR000A [ ] CleanEffects TM Whole House Air Cleaner (2" Wide, Downflow Furnace)... TFD2DALFR000A [ ] CleanEffects TM Whole House Air Cleaner (2-" Wide, Downflow Furnace)... TFD2DALFR000A [ ] Electronic Air Filter, Perfect Fit Super Efficiency (-" Wide Gas Furnace)... TFE5A9FR0 [ ] Electronic Air Filter, Perfect Fit Super Efficiency (7-" Wide Gas Furnace)... TFE75A9FR0 [ ] Electronic Air Filter, Perfect Fit Super Efficiency (2" Wide Gas Furnace)... TFE20A9FR0 [ ] Electronic Air Filter, Perfect Fit Super Efficiency (2-" Wide Gas Furnace)... TFE25A9FR0 [ ] Air Filter, Perfect Fit High Efficiency (-" Wide Gas Furnace)... TFM5A9FR0 [ ] Air Filter, Perfect Fit High Efficiency (7-" Wide Gas Furnace)... TFM75A9FR0 [ ] Air Filter, Perfect Fit High Efficiency (2" Wide Gas Furnace)... TFM20A9FR0 [ ] Air Filter, Perfect Fit High Efficiency (2-" Wide Gas Furnace)... TFM25A9FR0 [ ] Air Filter, Perfect Fit Standard Efficiency (-" Wide Gas Furnace)... TFP5A9FR0 [ ] Air Filter, Perfect Fit Standard Efficiency (7-" Wide Gas Furnace)... TFP75A9FR0 [ ] Air Filter, Perfect Fit Standard Efficiency (2" Wide Gas Furnace)... TFP20A9FR0 [ ] Air Filter, Perfect Fit Standard Efficiency (2-" Wide Gas Furnace)... TFP25A9FR0 [ ] Coil Enclosure (-" Wide Cabinets)... BAYCLEA22A [ ] Coil Enclosure (7-" Wide Cabinets)... BAYCLE7A722A [ ] Coil Enclosure (2" Wide Cabinets)... BAYCLE2A230A [ ] Coil Enclosure (2-" Wide Cabinets)... BAYCLE2A230A [ ] High Altitude Switch... BAYHALT28 [ ] Downflow Subbase... BAYBASE5 [ ] Propane Conversion Kit... BAYLPKT20B [ ] Propane Conversion Kit (With Stainless Steel burners)... BAYLPSS20B [ ] Masonry Chimney Vent Kit... BAYVENT800B [ ] Filter Accessory Kit Upflow (.5" & 7.5" Wide Cabiniets)... BAYFLTR37 [ ] Filter Accessory Kit Upflow (2" Wide Cabiniets)... BAYFLTR32 [ ] Filter Accessory Kit Upflow (2.5" Wide Cabiniets)... BAYFLTR32 [ ] Pub.. 22-666-07 5

General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) TUEA00A92A 0,000 3,000 30-60 0 x 6 /5 080-6x25 - in. Round - 2 5 2 56 2 5. 5-3/ x 6- x 30-9 / 0 TUEA060A92A 60,000 7,000 35-65 0 x 6 /5 080-7x25 - in. Round 3 5 3 56 3 5. 5-3/ x 6- x 30-2 / 5 TUEA060A936A 60,000 7,000 30-60 0 x 6 /3 075-6x25 - in. Round 3 5 3 56 3 9.0 5-3/ x 6- x 30-27 / 8 TUEB060A936A 60,000 7,000 30-60 0 x 7 /3 075-6x25 - in. Round 3 5 3 56 3 9.0 5-3/ x 9- x 30-37 / 27 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub.. 22-666-07

General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) TUEB080A936A 80,000 63,000 30-60 0 x 7 /3 075-7x25 - in. Round 5 56 9.0 5-3/ x 9- x 30-2 / 32 TUEB080A98A 80,000 6,000 30-60 0 x 8 /3 075-7x25 - in. Round 5 56 9.8 5-3/ x 9- x 30-2 / 32 TUEB00A936A 00,000 79,000 0-70 0 x 7 /3 075-7x25 - in. Round 5 5 5 56 5 9.0 5-3/ x 9- x 30-5 / TUEC00A98A 00,000 79,000 35-65 0 x 8 075 - x25 - in. Round 5 5 5 56 5.6 5-3/ x 23 x 30-62 / 5 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub.. 22-666-07 7

General Data PRODUCT SPECIFICATIONS MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) TUEC00A960A 00,000 79,000 30-60 x 0 075 - x25 - in. Round 5 5 5 56 5 3. 5-3/ x 23 x 30-62 / 5 TUEDA960A,000 96,000 30-60 x 0 075-2x25 - in. Round 6 5 6 56 6 3. -3/ x 26- x 30-86 / 7 TUED0A960A 0,000,000 0-70 DIRECT x 0 3/ 075-2x25 - in. Round 7 5 7 56 7 3.8-3/ x 26- x 30-93 / 8 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 8 Pub.. 22-666-07

Performance Data MODEL TUEA00A92A TUEA060A92A TUEA060A936A TUEB060A936A TUEB080A936A TUEB00A936A TUEB080A98A TUEC00A98A TUEC00A960A TUEDA960A TUED0A960A FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) SPEED TAP SPEED TAP - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black 0.0 0. 0.30 0.0 0.50 0.60 0.70 0.80 0.90 08 87 76 67 03 835 72 6 26 23 02 900 588 329 090 89 393 20 06 900 76 29 0 873 839 323 092 788 880 662 28 8 28 908 62 3 235 906 66 23 262 228 755 50 00 832 70 599 997 82 702 596 389 225 039 903 55 38 090 90 38 9 052 903 6 257 06 887 82 325 090 783 86 635 2 25 23 888 609 9 20 88 632 5 7 22 76 6 982 809 678 575 973 800 683 573 35 97 027 895 57 299 093 90 36 98 07 895 252 058 890 796 329 09 780 799 598 02 20 20 868 597 395 66 856 67 07 235 96 736 2 950 779 68 5 9 77 655 53 298 60 005 877 68 268 076 89 335 77 033 888 08 23 050 883 756 39 083 768 70 55 370 93 53 83 582 38 36 87 596 39 228 5 79 27 90 72 60 507 90 73 67 505 236 3 973 88 2 228 052 88 296 7 008 869 363 3 028 86 70 308 076 758 669 93 326 6 0 800 567 367 05 777 575 375 226 702 860 697 585 63 852 689 57 59 7 057 93 809 35 86 028 860 27 07 973 82 307 58 990 83 6 275 059 737 595 2 269 2 929 75 533 335 923 72 535 338 23 99 656 383 802 6 52 3 796 636 56 06 099 99 879 760 278 35 978 828 89 058 928 808 2 0 936 79 573 26 00 79 89 35 99 073 856 690 98 302 80 67 9 300 69 887 609 35 763 585 52 357 73 575 52 35 0 96 87 700 0 072 97 777 999 873 766 63 030 866 72 80 005 67 38 256 7 009 766 63 38 256 750 602 27 26 989 797 56 298 660 57 38 29 659 506 379 277 93 83 75 629 02 988 836 638 02 930 808 77 07 96 780 680 392 65 970 630 260 57 022 935 676 572 377 9 659 533 360 92 908 706 58 2 From D330672 Rev. 6 Pub.. 22-666-07 9

Performance Data CFM VS. TEMPERATURE RISE MODEL CFM (CUBIC FEET PER MINUTE) 500 600 700 800 900 000 00 0 300 00 500 600 700 800 900 00 200 20 2300 0 *UEA00*92** 5 9 2 37 33 30 *UEA060*92** 63 56 9 *UEA060*936** 56 9 0 37 3 32 *UEB060*936** 56 9 0 37 3 32 *UEB080*936** 59 5 9 6 2 *UEB00*936** 58 52 9 6 2 0 37 35 33 *UEB080*98** 67 62 57 53 9 *UEC00*98** 67 62 57 53 9 6 39 37 *UEC00*960** 62 57 53 9 6 39 37 35 3 32 3 *UED*960** 59 56 52 9 7 2 0 *UED0*960** 69 65 6 58 55 52 9 7 5 From C30782 Sh. Rev.7 0 Pub.. 22-666-07

Field Wiring WIRING DIAGRAM FOR TUE GAS FURNACES Pub.. 22-666-07 From Dwg. D32777P0 Rev 0

Field Wiring SCHEMATIC DIAGRAMS FOR GAS FURNACES From Dwg. D32777P0 Rev 0 2 Pub.. 22-666-07

Field Wiring FIELD WIRING DIAGRAM FOR HEATING ONLY FIELD WIRING DIAGRAM FOR STAGE FURNACE STAGE HEATING USING A STAGE HEATING THERMOSTAT NO COOLING FURNACE SEE NOTE 6 B/C SEE NOTE 5 B/C TO 5 V PH., 60 HZ., POWER SUPPLY PER LOCAL CODES From drawing B326 Rv 0 FIELD WIRING DIAGRAM FOR HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIAGRAM FOR STAGE FURNACE STAGE HEATING, STAGE COOLING USING A STAGE HEATING, STAGE COOLING THERMOSTAT (OUTDOOR SECTION WITHOUT TRANSFORMER) FURNACE OUTDOOR UNIT (NO TRANSFORMER) B/C SEE NOTE 5 B/C TO 5 V PH., 60 HZ., POWER SUPPLY PER LOCAL CODES From drawing B323 Rv 0 Pub.. 22-666-07 3

Dimensions TUE OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) MODEL A B C D TUEA00A92A TUEA060A92A -" 9-5/8" 3-/" 3" TUEA060A936A TUEB060A936A TUEB080A936A TUEB080A98A TUEB00A936A 7-" 9-5/8" 6-/" 6" TUEC00A98A TUEC00A960A TUEDA960A TUED0A960A 2" 3-/6" 9-3/" 9-" 2-" 5-5/6" 23-/" 23" From Dwg. 2C3078 Rev. 3 Pub.. 22-666-07

tes Pub.. 22-666-07 5

Trane 60 Troup Highway Tyler, TX 75707 File. PL-UN-FURN-TDD-D- 3/98 0/09 Supersedes TDD-D- 8/95 Since Trane has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.