STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Similar documents
OPERATION INSTRUCTION

IONIZING AIR BLOWER INSTRUCTION MANUAL

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

Ionizer (Static Remover) STABLO-EX Instruction Manual

3M Overhead Ionizing Blower 991A

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

3 963/963E Benchtop Air Ionizer Instructions

Bench Top Ionizer Installation, Operation and Maintenance

ELIMINOSTAT DC-ESR-CL-S2

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

Eagle 2500 TM OWNER S MANUAL. Electronic Air Purification 110 and 220 volt Systems. EcoQuest International. Application.

3M Benchtop Air Ionizer 963E. User s Guide

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

CA3500, BA3500, CH3500 New Comfort

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Electrostatic Air Purifier

Bar Fridge USER MANUAL MB46W

Int 937. Soldering Station. Instruction Manual. Correct Disposal of this product

IMPORTANT INSTRUCTIONS READ & SAVE

Thank you for buying this refrigerator-freezer. To ensure that you get the best

AdvancedPureAir.com

Wine Cellar. Instruction Booklet. Model: WC-2038

Critical Environment Ionizing Blower. Model 5810i. User s Manual

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

Instruction Manual STATIC ERASER TOP FAN. Table of Contents

Refrigerator Freezer HD-368RWEW

Instruction Manual. Chest Freezer Model: CF.142L

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Comefresh CF-8608 Air Purifier

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

Clean Air Optima Plasma Ionizer Air Purifier CA-267

Operating Instructions

Ozone Generator Air Purifier HE-500/O3

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS

IMpORTANT SAFETy INSTRUcTIONS

AirInstinct Air Purifier

Ionic Breeze QUADRA Silent Air Purifier. SI637 SI697 Instructions

CRITICAL ENVIRONMENT (C/E) SERIES OVERHEAD IONIZER OWNER S MANUAL

IMPORTANT INSTRUCTIONS OPERATING MANUAL

FATG OM 0604 OWNERS MANUAL. Anywhere. Everywhere. Fresh Air... To Go.

Gallery Electric Fireplaces

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

FR-1020ARW FR-1020ARS

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

FOR THE FOLLOWING MODELS : EE-7588R EE-7588W EE-7588O EE-7588B EE-7588M

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Chargebuster Ion Gun Installation, Operation and Maintenance

IMPORTANT INSTRUCTIONS READ & SAVE

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

WHD-125FW1 //WHD-125FB1/WHD-125FSS1

CERAMIC FAN HEATER URBAN

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

PARAFFIN/DIESEL HEATER

WARM & COOL MIST Ultrasonic Cool Mist Humidifier

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

SAVE THESE INSTRUCTIONS

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

Living Air Electronic Air-Purification Systems

Refrigerator - Freezer

DIESEL/PARAFFIN HEATERS

Adjustable Standing Patio Heater 2000w

Dehumidifier. Instruction Manual. Model DH-320/A

WINIX AIR PURIFIER. User Manual. Tower XQ

PERSONAL 1500W CERAMIC HEATER Instruction Manual

MeacoClean CA-HEPA 119x5 Air Purifier

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

CERAMIC HEATER MODEL # EE If you have any questions about the operation of your ceramic heater, please contact Crane Customer Care.

YOUR PORTABLE AIR PURIFIER

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

ADORABLE Ultrasonic Cool Mist Humidifier

Model LA-2SP. Air Purification Unit. User Guide. Bring Freshness Indoors

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

Dual Zone Wine Cellar

GDDEM10 DEHUMIDIFIER

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

Chargebuster Ion Gun Installation, Operation and Maintenance

Inverter Split-type Room Air Conditioner

User Manual / Installation Instructions

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

Transcription:

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Thank you for purchasing a Static Eliminator. It is designed to eliminate the static charge from a charged object. Please read this manual before operating the static eliminator. Keep this manual readily accessible for reference. The static eliminator can be mounted on the arm of optional moveable fixture to provide a wider range of angles and positions from which to approach the charged body.! WARNING Precautions Page12 Arm stand *Specifications and design subject will be changed without notice. Warnings and cautions are placed at critical points in this manual to direct the operator s attention to significant items. They are defined as follows:! WARNING Failure to comply with a WARNING may result in serious injury or death.! CAUTION Failure to comply with a CAUTION may result in injury to the operator, or damage to the items involved. High voltages are produced inside the static eliminator main unit. Observe the following warning to avoid the danger of electric shock. * Do not touch the electrodes while the power is ON. * Do not put metal parts or other foreign objects into the panel. * Carry on daily inspection and regular maintenance procedures. This unit is not explosion proof. Do not use this unit near combustible gases or organic solvents.! CAUTION To prevent accidents and failures, be sure to observe the following precautions: Do not use the unit near flammable materials. Turn off the power after using.

When changing parts of the unit, only use genuine replacement parts. Do not wet the unit or use it with wet hands. Remove power cord by holding the plug, not the cord. Section 1 Summary Page1 Thank you for purchasing this static eliminator. It is important to read this instruction before operating and installing. It helps to installation, use and maintenance. Fail to do so could result in serious personal injury and/ or damage to the equipment. The blower is designed to purify air in room and eliminate static charge for sensitive electronic components. It can be applied in inspection, testing, assembly and laboratory environments. The blower can also be used where static charge causes problems such as: dust attached on product, misalignment of small parts due to electrostatic jumping, and undesirable adhesion of plastic films due to static charge. This blower is portable ionized air blower, plastic enclosure, legerity and insulation. It uses a small fan to produce large airflow. The volume of airflow is controlled by variable speed knob which provides a wide range of airflow settings. The ionizer uses a transformer which produces low current and high voltage. This transformer is inherently current limited for safety. The transformer output also contains current limiting resistor which provides redundant safety and enhances the ionization stability. The high voltage is applied to a row of tungsten steel ion emitters which produce positive and negative ions, and the ions will be output with airflow. It is this intense electric field that injects alternating polarity ions into the airflow. The shaped airflow exiting the Blower carries these ions over a broad area for static elimination. Directing the airflow on an object that has a static electricity charge will neutralize the charge. If the object has a positive static charge, it will draw negative ions from the airflow. If the object has a negative static charge, it will draw positive ions from the airflow. The ions are attracted to the oppositely charged object and neutralize the charge on the object. Section 10 Trouble shooting Page2! WARNING To avoid shock, always, unplug the power cord before inspecting the unit or changing parts. 1. The unit will not operate when the power switch is turn on. Check 1:Is the fuse broken? Action: Replace the fuse Check 2:Is the power cord plugged in? Action: Plug it in. Note: * There is a spare fuse in the fuse holder. * Be sure to replace it with a fuse of the same specification. 2. The air is airflow but the static is not eliminated. Check 1: Is dust or other foreign matter collected on the electrodes? Action: Clean the electrodes. Check 2: Is the filter dirty? Action: Clean or change the filter. For any problems other than those listed above, contact our company or our sales agents in your area. Section 11 Optional /Replacement parts The filtration sponge is a replacement part, if you need, you can order. When cleaning the filtration sponge, rinse the sponge in plain water and gently

squeezing. If the dust is stubborn, wash the sponge in mild soap then rinse. * Check if it is grounded correctly. be read with the static meter. Turn on the BLOWER and set the fan speed to high. Hold the plastic 30cm from the ionized air outlet for about 5 seconds. Remove the plastic from the ionized air Page11 stream and measure the static charge. The plastic should be neutralized. If no instrument is available, the unit s operation can be verified with the following procedure. Tear off about a 25cm length of transparent tape. You will note that the tape is charged and will be easily attracted to a nearby surface when the tape is held vertically approximately 30mm from it. Make the tape pass through the ionized air stream approximately 30cm from the unit and 5 seconds later, approach the non-adhesive side of the tape with your free hand. If the charge has been neutralized, it will not attract. Do not try to verify operation of the unit by drawing a spark from an ion emitter point. The design of the balancing circuit makes the spark test inconclusive. Sustained grounding of the ion emitters may damage the balancing circuit. Note: When performing this procedure, do not use a plastic surface such as Plexiglas as the surface, since itself maybe charged and attract the tape. A safe surface would be a metal leg or drawer front on a workbench. Note: If the ion balance deflection is too much, please contact agent or our company. Section 2 Features 1. Compact design, light weight, Page10 portable and adjustable angle. 2. Rapidly neutralizes static charges. 3. Ion balance and stability is very good. 4. Wide ion air area. 5. Variable speed fan with wide range of airflow. 6. Plastic enclosure and good insulation. 7. Filter is installed with magnet, convenient to clean. Section 3 Specifications Ion balance: less than ± 5V when regulating in the company, determined as association standard ANSI/ESD-S20.20-1999 Output voltage: ±5000VDC Ozone Production: less than 0.01 PPM Measured 15cm from the unit. Efficiency range of ionizing air area: 40cm 150cm 1. Daily inspection * Make sure no abnormal odor, smoke, or abnormal noises are emitted from the unit while it is running. * If any abnormal odor, smoke, or abnormal noises is observed, stop using immediately. Turn the switch off and unplug the power cord from the socket. Contact agent.

ambient environment. Environment Temperature: 0 --50 Housing material: steel Weight: 1.25Kg (without power cord) Dimension 13.5cm(W) 19.0cm(H) 7.5cm(D) Audible Noise: Fan Speed Low High Page3 40dB 45dB Measured 1m from the unit. Eliminating static time (s): Fan Speed High 30cm 60cm 90cm 120cm 1.4 2.5 5.4 8.8 15cm 1.1 2.7 6 9.2 Center Line 1.4 2.5 5.4 8.8 15cm 1. Ion balance and neutralizing time is measured according to American Standard ESD-STM 3.1-2000 and ANSI/EOS/ESD-S3.1-1991 using CPM374 charged plate monitor. 2. Neutralizing times from 1000 volts to 100 volts are measured as the above show. 3. Above testing value will vary with difference temperature, humidity and! WARNING Section 9 Maintenance Do not neglect to perform the maintenance and daily inspection described as follows. Dust collected on high voltage areas may lead to a fire hazard. 2. Clean the electrodes Turn the power switch off and unplug the power cord. Take out the fixture behind the unit, clean the electrode and its white fixture socket with the attached cotton swabs dipped with alcohol.! CAUTION: Make sure fibers from the cotton swabs don t stick the electrodes. 3. Clean filter Page4 Turn the power switch off and unplug the power cord. Take out the fixture from the rear of the unit and separate the shield from sponge. Rinse the filter with clean water. If filtration sponge is used, wash and squeeze it gently. If

the dirt is stubborn, wash the filter in mild soap. After wiping up the plastic shield with paper or clean towels and allowing the sponge become dry, reinstall the fixture again. Note: If the filter is used, regular clean should be performed. A clean filter is vital for the operation of this unit, clean regularly. 4. Ion output check CMP374 (Charge plate monitor) can be used to test the neutralizing time and ion balance. If a charged plate monitor is not available, but a handheld electrostatic field-meter is available, ion output may be checked with the following procedure. Take a piece of plastic and rub it with cloth until static charge can 2. Turn on and off power switch Page9 The power switch is on the power socket behind the unit. Turn the power switch on, the Blower works and produce the ion air. Turn the power switch off, the Blower stops working. 6. Shut down After using, turn the power switch off and unplug the power cord from the socket.! CAUTION If any abnormal odor or abnormal noise is observed, stop using immediately. Turn the power switch off and unplug the power cord from the socket. Contact agent or our company. Section 4 Picture Page8 3. Adjusting air volume In accordance with work requirement, adjust the airflow adjusting knob to select the appropriate airflow. Turn it clockwise to increase the airflow and turn it anticlockwise to decrease the airflow. 4. Adjusting angle Loose the angle adjusting knob. Direct the unit toward the charged body. Adjust the position and the angel of the unit, then tighten the adjusting knob. 5. Eliminate static electricity As the ionized air meets with the charged body, it begins to neutralize the static charge.

Section 5 Safety Please read the instruction manual completely before operating the device. This machine is equipped with a 3-wires grounding plug and must be plugged into a 3-terminal grounded socket. Do not modify plug or use an ungrounded power socket. If an extension cord is necessary, use only a 3-wire extension cord that provides grounding. To prevent accidents and failures, be sure to observe the following precautions: 1) Read this manual carefully before operating and installing. 2) Make sure the voltage accord with rated voltage on the nameplate behind the unit. 3) This machine should be equipped Page5 with a 3-wires grounding plug and must be plugged into a 3-terminal grounded socket. 4) Do not insert any object through intake or outlet grille. 5) Do not operate the device under inflammable or explosive atmospheres. 6) Maintenance and inspection inside the unit should be carried out by qualified professional. 7) Don t touch the ion emitter when working. Section 6 Installation 1.The Blower is designed for portable or permanent operation. Its base stand can be placed at workbench or installed on flat surface. If the base stand is installed on the wall or ceiling using 4 diameter screws, the blower can be used on moveable fixture. (Moveable fixture is optional.) 2. Under the unclean environment, you can install the filtration sponge. Take out the fixture and separate it. Place sponge in the shield 1 and cover it with the shield 2, press down the edge of the shield 2, so that it will be locked in. The fixture is fixed with magnet, place or take out it directly. shield 1 Filter sponge Shield 2 3.The Blower should be placed approximately 300mm to 900mm from the critical work area or objects to be neutralized. The closer the unit is to the charged body, the higher the static Page6 eliminating effect will be. It should be positioned to cover as much of the area as possible with the ionized air stream. The air stream can be directed upward or downward by tilting the unit in its stand. Loosen the angle adjusting knob. Direct the unit toward the charged body from which you wish to eliminate static electricity. Adjust the position and the angle of the unit and tighten the adjusting knob. 4. Operate the Blower with right power voltage, the frequency is 50/60Hz. For safety, this unit is equipped with a 3-wires grounding plug and must be plugged into a 3-terminal grounded socket. Do not modifying plug or using an ungrounded power socket. Section 7 Inspection before using 1. Clean the ion emitter. 2. Check the grounding. 3. Check the device is good or not. 4. Check humidity and other pollutant.

5. Check whether the used voltage accord with the voltage on the nameplate. Section 8 Operation 1. Switch on power Affirm whether the used voltage accord with the voltage on the nameplate. Insert the power plug into power socket behind the unit and 3-terminal grounded socket. Page7