CIRCO 6 Solar Circulation Unit

Similar documents
Commissioning a Solar Thermal Installation

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

ECOplus Solar Cylinder

Solar Controller SUNGO SL

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

TERMO Combi Cylinder TECHNICAL INFORMATION

Solar station DKP 6-8 / DKP Installation and Service Manual C

Installation and instruction manual SOLAR STATION

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology

Manual SLM50HE.

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

HeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL

Operating Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

Installation, Operating and Servicing Instructions

Installation Instructions

General System Layout Sketch

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER

Problem-solvers The Radiator Solution Range

INSTALLATION INSTRUCTIONS

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

Model: 1100 Float-Controlled Condensate Trap, PN 25

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

UV I UNIT030W / UV I UNIT055W

Installation instructions

Installation Instructions

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

Manual. Above-counter dispenser for hot drinks OTHG /12

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Installation, Operating and Servicing Instructions

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

INSTALLATION INSTRUCTIONS

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

INDIVIDUAL HEATING. Installation Manual e Skirting Heating Classic. Skirting Heating Delta. HEATING. COOLING. COMFORT.

Viking Installation Guide

HKF 8180 Operating instructions

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Technical information for installation and operation

Pump assembly Instruction manual

DISHWASHER INSTALLATION INSTRUCTIONS

ROTEX RMX Heating circuit distributor

CONNECT SOLAR MR - 7,5m

INSTALLATION GUIDELINES

Crown Boiler Company

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

D O M E S T I C Solar Thermal

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

User Manual FANG 18 C. Company information: Original instructions 80188EU (1)

TTV 4500 / TTV 4500 HP / TTV 7000

Enzo Concealed Shower Mixing Valve

WZS series. Hot water circulation systems for energy storage tanks

C B SOLARTHERMAL. Solar thermal systems

Moisture inside the drum is due to final testing.

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

WOLF VENTILATION SYSTEM PRICE LIST

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Micro/Ultra Filtration System StamoClean CAT 430

General System Layout Sketch

infranomic INFRARED HEATING PANELS Operating and Installation Instructions Wolff+Meier GmbH & Co. KG Glaswerke Am Wingert Langgöns Germany

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Solar heating systems

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Read these instructions before using and keep them available at all times!

Solar Thermal Energy

Grohtherm Wireless! Installation Instructions Pumped High Pressure

Commercial Fan Heater

Domestic Hot Water Tank

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Installation guide PRO7-VAQ E. Before installing read this guide first

Thermostatic valves with radiator connection systems

Grohtherm Wireless! Installation Instructions Pumped

L A signature series TA T N E RE O, A L L A T S IN

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Installation Manual. Models 99168, 99169, 99170

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Installation Instructions

Cooler Manual XRC-3012-WA 3000 Watt water to air cooler

INSTALLATION INSTRUCTIONS

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

Storage tank size Rated volume [l] Actual volume [l]

Brawa-Mix Thermostatic mixing valves

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Transcription:

TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a solar installation Fast Installation thanks to pre-assembled parts and compression fittings for the connection to the solar circuit Safe Deaeration by integrated air bleeder Operation Monitoring via flow-meter and integrated thermometer Controlled Heat Flow by two temperature resistant non-return ball valves Low Heat Loss made possible by all-around heat insulation made from close fitting hard foam shell Figure 1 CIRCO Solar Circulation Unit with integrated controller (not included in delivery). Solar Thermal / Solar Circuit EN-XXX_CIRCO-_MA-10011-111Y00 1

1. General Safety Guidelines Qualification of the Installer Setting up, installation and commissioning of the CIRCO solar circulation unit must be carried out by a qualified installer. Please note that in case of a fault report the guarantee benefits can only be claimed if the correct commissioning has been certified by a qualified person in the commissioning report. The warranty period for the station is years. Use and Application Function The CIRCO solar circulation unit is suitable for solar hot water systems and solar heating support systems in connection with antifreeze solar liquid as recommended. Limitations of Use Applications are limited to the hydraulic layout of the schematics supplied by Wagner and Co. Some solar installations for space heating and the application of vacuum tube collectors do require special provisions for overheating protection, like the installation of a heat dissipation vessel or alternative positioning of the safety components (See document Solar Thermal Systems - Setup, Startup and Maintenance ). The solar circulation unit can be wall-mounted or directly installed to the storage cylinder using the cylinder mounting kits for the ECO, TERMO and RATIO line solar cylinders The CIRCO solar circulation unit must not be installed outdoors. DANGER of personal injury Electrical installation of the device can lead to potentially fatal electric shocks, scalds, contusions as well as other health hazards. Therefore please ensure to observe all information in the guidelines marked with this symbol. CAUTION against property damage This symbol indicates dangers that can result in damage to the components or significantly degrade the functionality of the solar heating system. Please ensure to carry out the installation steps described in these guidelines in the correct order. NOTE for additional information This symbol indicates practical advice which will be useful for installing and operating the device. Norms and Directives EC conformity declaration The CIRCO solar circulation unit has been designed and constructed in accordance with EU regulations. Please regard national and EU regulations and guidelines for installation work. Especially observe EN 1 and ENV 1: Thermal solar systems and components. Standards and Codes The effective standards, codes and regulations at the installation location must be observed. In Germany especially: Electrical installations and device connections must be carried out according to VDE 0100 und DIN 11 Setting up potential equalization must follow VDE 010 DIN must be observed for installation, start up and maintenance of system for domestic hot water preparation and process water heating. DIN EN V 1: Thermal solar systems and components. EN-XXX_CIRCO-_MA-10011-111Y00

. Technical Information Scope of Delivery The CIRCO solar circulation unit is supplied pre-assembled. SUNGO control and CIRCO expansion kit are not part of the unit. Additional accessories are shown on the last page. Table 1 Maximum Number of Collectors to be Installed 1 Coll.-type EURO C0 HTF/AR, C HTF/AR Serial-/parallel connection Serial connection 1 Ø Ø Ø 1 Ø Ø Ø x x x EURO L0 AR x x x 1 Simple pipe length of solar circuit up to 0 m, heat transfer medium: antifreezes/water 0/0 Vol % = l/m². Connections and connection pipes of collectors are accounted for. No. of fields with collectors connected in series each Table Volume of Expansion Vessel 1 Sys.- Coll.- Volume (l) for system height (m) vol. (l) area. (m²).. 10 1. 1 1 1 1 1 1 1 1 0. 1 1 1 1 1 10 1. 1 0 0 0 0 1 These values only apply for collecor volumes of approx. 0. l/m² Table CIRCO Solar Circulation Unit Part no. 10 01 1 Insulation EPP two parts Max. operation pressure bar Max. operation temperature 10 (during start-up phase temporarily up to 10 ) Circulation pump Wattage Max. pump head Max. flow rate Return flow stoppers Temperature display Sockets for temperature sensors Flow meter Safety group Filling unit Connection expansion vessel Connection bleeder pipe Connection solar circuit Axial pipe distance for solar circuit Installation type Dimensions (HxBxT), mm ST - (0 V, 0 Hz) -levels, //1 Watt m. m³/h x, can be disabled dial thermometers In supply and return leg one each for sensors of max. mm Ø -1 l/min Safety valve bar ½", pressure meter filling valves with cap ¾" M ¾" F Weight, kg. Slot for solar controller compression fittings, mm 100 mm Wall inst. / inst. at cylinder (with optional kit) x 0 x 1 mm Prepared for integration of SUNGO S / SL / SXL Pressure loss p [mbar] Pressure loss p [Pascal] 10³ 10 v 0 0, 1,0 1,,0 [m/s] H [m] III 10² 10 I 1 0 0 1,0,0,0 [m /h] Figure Pump characteristics curves CIRCO 10 10³ 10² 10³ Flow volume V [l/h] Figure Pressure loss diagram CIRCO EN-XXX_CIRCO-_MA-10011-111Y00

. Installation 11 1 10 1 1 1 Figure 1 Pump; Safety group; Connection (¾") for expansion vessel-set (available as accessory); Filling valve; Rear insulation shell; Front insulation shell with opening for controller; Cover (when controller not installed); Wall brackets; Bleeder; 10 Flow meter; 11 Controller mounting block; 1 Dry wall anchors; 1 Controller SUNGO; 1 Fixing screw 0 G1 G1 10 G¾ Rp¾ G1 G1 Figure Dimensions in mm 100 EN-XXX_CIRCO-_MA-10011-111Y00

.1 Installation Preparations The entire layout of flow and return pipes should be clear before installing the CIRCO solar circulation unit (100 mm centres). The location of the installation also must take into account sufficient space for the expansion vessel! If the solar system is installed for heating or if vacuum tubes are used you must pay attention to the technical documentation Overheat Protection. For the required tools see figure. Wall Installation Remove front insulation shell (). Make two drilling holes with mm vertical distance for the two wall brackets () (figure ). Screw on solar circulation unit. Connect safety group () to the included ¾" gasket to the return leg. Secure nuts by applying counter force with nd wrench while tightening the connections. Otherwise parts of seals might come of or the connections could be damaged. Affix wall bracket for expansion vessel next to the station. Take length of the flexible connection tube into account. Connect expansion vessel to safety group via the connection tube. Don t forget the seals/gaskets! Maintenance can be made easier by installing an additional capped valve between flexible tube and vessel. Connect venting pipe to safety valve and place an empty canister underneath to collect possible spills of solar fluid. Figure Tools for CIRCO installation The solar circuit pipes are connected via compression fittings 1 mm or mm. Cut and burr pipes and push into fittings as far as possible, then tighten nuts. To avoid damage, secure nuts by applying counter force with nd wrench while tightening. Rinse solar pump station and solar circuit and check for leaks. For this purpose filler valves are fitted to the safety unit and to the flow meter. Install electrical wiring, switching and sensor lines. The cables must not touch on hot pipe legs. Always disconnect mains when working with electrical equipment. The controllers SUNGO S, SL and SXL can be integrated into the solar circulation unit. For this purpose screw the included drywall anchors (1) into the drillings of the controller installation slot. Then set on controller (1) with lower side. Screw controller into the installation slot with the fixing screws (1 + 1). During wiring use wire straps at appropriate place for pull relief of the controller terminals. Re-attach front insulation shell (). EN-XXX_CIRCO-_MA-10011-111Y00

1 0. Installation at Cylinder The adjustable installation kits can be used with all Wagner solar cylinders with 1¼" flat sealing connections at the heat exchanger, with a vertical distance between 0 and 0 mm. To prevent later obstructions of the pipe work in the area of the cylinder, it is recommended to make proper lay- out plans before commencing installation. 0 0 0 0 0 0 0 0 0 0 Connect pipes to cylinder using supplied gaskets, tighten hand-screwed. Cut off longer return pipe until both pipes are reaching the same level and have an axial distance of 100 mm. Then screw tight adjustable pipe. Trim off the insulation of the cut-off return pipe and place circulation unit on top of the two pipes. 100 D = for compression fitting Return pipe Level the unit, affix to cylinder and tighten cylinder connections. 0 mm Continue with piping behind the solar circulation unit. 1¼ union nut Insulation In order to prevent forces to the cylinder fixing because of weight load from the station, pipe fixtures should be installed near the unit at the wall or at the ceiling. The expansion vessel must not be freely suspended from the pump station. Apply wall or floor installation, depending on type of vessel. Applicable for 0 to 0 mm Filling valve Figure Cylinder installation kit (option) consisting of: 1 return pipe with integrated filling valve, incl. insulation; connections: 1¼" swivel nut mm pipe socket for compression fitting, 1 supply pipe incl. insulation; connections: 1¼" swivel nut mm pipe socket for compression fitting. EN-XXX_CIRCO-_MA-10011-111Y00

. Operating Advice The Flow Meter The flow meter indicates flow in l/min during pump operation. The adjustment screw can be used to cut off the flow. For operation the adjustment screw must be turned fully counterclockwise (max. flow). The adjustment of the volume flow should only be done via the pump settings. Return Flow Stoppers They are integrated into the ball valve components and prevent unwanted heat distribution in the solar circuit when the pump is turned off. They only open in the flow direction under pump pressure. The stopper in the feed leg can be turned off with the ball valve handle, the one in the return leg with a slotted screw (figure and 10). Flow open Return flow stopper in operation Operational position L/MIN 1 1 Index line Flow metering Flow open Return flow stopper off Flow closed Return flow stopper without function Figure Flow meter of CIRCO Setting Up the Pump Setting up the pump is carried out when the solar installation is filled and vented and the pump is operating. First set pump to lowest level. Then switch on pump via controller menu manual operation, so that speed control is disabled. The recommended volume flow in the solar circuit is 0 l/m² collector area and hour. Values between 0 and 0 l/m² h are acceptable. Higher volumes result in increased power uptake of the pump. Choose next higher pump level if the recommended volume flow is not reached. Example: Collector area 1 m² > recommended volume flow = 1 m² x 0 l/m²h = 0 l/h = l/min. After setting up the pump assure its automatic operation. Figure Functions of ball valve and return flow stoppers in supply leg (left pipe) Return flow stopper adjustable via ball valve! Flow open Return flow stopper in operation (slot horizontal) Operational position Flow open Return flow stopper off (slot vertical) Flow closed Return flow stopper without function Figure 10 Functions of the ball valve and the return flow stopper in the return leg (right pipe) Return flow stopper adjustable via slotted screw! EN-XXX_CIRCO-_MA-10011-111Y00

. Accessoires Table Accessories Description Part no. Compression fitting for pipe connection Accessory set solar circuit Air venting kit (not normally required because of included bleeder pipe) CIRCO-expansion vessel set Capped valve for expansion vessel Acessory / spare part: for 1 mm copper pipe for mm copper pipe Accessory parts for solar circuit piping: filling valves and grounding clamps for potential equalization Automatic air venting kit consisting of automatic air venting valves and heat resistant ball valves (up to 00 ), connection /" 10 01 10 01 10 10 10 10 11 Manual air release set consisting of manual air release valves /" and key 10 10 10 Expansion vessel for solar circulation unit, allowed positive operating pressure 10 bar, stainless steel corrugated tube for connecting with CIRCO solar circulation unit, thread connection ¾" female flat sealing 1 l-volume, incl. wall bracket, pre-pressurized: 1. bar 1 l-volume, incl. wall bracket, pre-pressurized: 1. bar l-volume, incl. wall bracket, pre-pressurized: 1. bar l-volume, with brackets for wall and floor fixing, pre-pressurized:. bar 0 l-volume, with brackets for wall and floor fixing, pre-pressurized:. bar Check valve ¾" with filler and drain valve and with cap against operation mistakes. Suitable for maintenance purposes. 10 0 10 10 0 11 10 0 1 10 0 1 10 0 1 ¾" - version 1" - version 1 00 1 00 Cylinder mounting kit for CIRCO und E Cylinder piping 1¼" M with flat seals, insulated; return pipe for cylinder connections with 0 to 0 mm vertical distance (can be cut to size), with mm sleeves to connect to compression fittings of CIRCO and E. 10 0 01 Subject to modifications, errors excepted Wagner & Co, 010 www.wagner-solar.com WAGNER & CO Zimmermannstraße 1 D-01 Cölbe/Marburg % + (0) 1 0 0-0 Fax 0 0-