Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

Similar documents
actoolsupply.com YOUR SINGLE SOURCE FOR INDUSTRIAL ELECTRICAL PROTECTION actoolsupply.com

PROTECTING AGAINST ARC FLASH HAZARDS

Safety Meeting Topic #37 NFPA 70E What is it?

ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009.

SALISBURY ASSESSMENT SOLUTIONS

SALISBURY. Y o u r s i n g l e s o u r c e f o r p e r s o n a l e l e c t r i c a l - s a f e t y p r o t e c t i o n

NFPA 70E Electrical Safety in the Workplace

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

The Basics Arc Flash Protection

Brian McCauley December 2017

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

ENERGY - TRANSMISSION & DISTRIBUTION - SAFETY IDENTITY OF SAFETY

NFPA 70E Electrical Safety & Arc Flash Training

Personal Protective Equipment. Shawn Appling Associate Extension Agent, Culpeper County Office Serving Culpeper, Madison, and Orange

Applying the 2012 NFPA 70E. Arc Flash Standard

NECA. Standard for Electrical Safety in the Workplace

Electrical Safety for Facility Managers and Building Owners

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

NECA S System Approach to Electrical Safety for NFPA 70E

2014 National Electrical Code & NFPA 70E/Arc Flash

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle

Electrical Safety Compliance: NFPA 70E

PREPARING YOUR ORGANIZATION FOR NFPA 70E 2015

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

NECA S System Approach to Electrical Safety for NFPA 70E

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Webinar November 12, 2014

OBERON USER GUIDE Arc Flash Suit Care & Use

Honeywell Salisbury PrismShield Colors within Sight, Safety on Site

6/23/ National Electrical Contractors Association and Intec, Inc.

NFPA 70E Elevates Safety. with Heightened Risk Awareness

MACHINERY & EQUIPMENT INDUSTRY-SPECIFIC PROTECTION SOLUTIONS QUICK REFERENCE GUIDE

Electrical Hazards and NFPA-70E: Protecting Your Employees

HOW TO CHOOSE THE RIGHT PROTECTION FOR FIRES, FLASH FIRES & ARC FLASHES

26 th January 2016 SESSION TWO TECHNICAL REQUIREMENTS

ELECTRICAL SAFETY GUIDELINE

TFCA Best Practices: Ch.11. ROFR Section: PERSONAL PROTECTIVE EQUIPMENT PROTECTIVE CLOTHING. Effective: 3/2013.

Honeywell Safety Products

INTERNATIONAL STANDARD

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

NFPA 70E Edition Update

SAFETY PRODUCTS CATALOG

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

PPE HAZARD ASSESSMENT CERTIFICATION FORM

NFPA 70E Update: Key Changes You Need to Know to Assure Compliance

Centennial Energized Electrical Work Permit Instructions

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

The safe way to verify the absence of voltage.

Arc Flash Protection Training - NFPA 70e Electrical Safety

PAPA SAFETY COMMITTEE

2009 NFPA 70E Clearing Up Confusion

HI-VIS WORKWEAR & RAINWEAR. Medium. Large. X-Large. 3X-Large. 2X-Large. Small. 4X-Large

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

WORKPLACE EVALUATION CHECKLIST & REPORT

FIRE SUPPRESSION TECHNICIAN

Electrical Preventive Maintenance (EPM) Program

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

DON T GET BURNED BY THE CONFUSION:

Generic and Sector Specific PPE Standards

SEL Arc-Flash Solutions

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Power Isolation Solutions. Arc Flash Prevention Starts Here

Why Buy Certified? Understanding Standards NFPA 2112 and ASTM F1506 and Why Certification Matters When Selecting FR PPE

Polk County Fire Rescue Turnout Gear and Ensemble Elements


CELLGUARD SYSTEM-ELS+ ELECTROLYTE LEVEL MONITORING SYSTEM. user GUIDE

Flame retardant. Protectivewear fabrics by Klopman International

Fire ground electrocution

SEI Certification Program Manual

Machine Guarding. 1 Copyright 2014, Rev by PEC Safety Management, Inc. PPT-SM-MG 2014, Rev

Using Height Access Poles for Safe Testing Of Fire Detection Systems

This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords).

Care and Cleaning Recommendations for Mount Vernon FR Flame Resistant Fabrics

SEL Arc-Flash Solutions

Protective Apparel English

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

This page intentionally left blank

DUAL MIRROR ALUMINIZED FABRICS. Protection You Can Count On. Value You Can t Beat.

Wagner Meters has been an industry leader for over 40 years, creating innovative top-of-theline moisture measurement equipment.

Flame Resistant Clothing: Statistics, Standards and Safety

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

4.1 Need For Ironing / Pressing

Lead them to safety. Honeywell Safety Products. Honeywell can help you build an enduring culture of safety.

DuPont NFPA Certified Attire

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022

PROTEK PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR

Electrical Safety Program.

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

7 SAFETY ESSENTIALS YOU SHOULD KNOW ABOUT. graybar.com/safety

8/2017. Firefighter protective clothing ANACONDA. 3rd category of Personal Protective Clothing

Employee Health Protection

NECA & Salisbury Assessment Solutions Partnership

Transcription:

Be Smart. Be Safe. Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards. ISO 9001:2000 Registered SALISBURY 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax arcsafety.com 866.824.4922 e-mail info@whsalisbury.com www.arcsafety.com 1

SALISBURY Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards. The following information will give you a better understanding of the NFPA 70E standard, why it s important and what is needed to meet its requirements. It will also provide you with the pertinent questions needed to ask when selecting the appropriate equipment needed to meet the NFPA 70E standard. Salisbury is your complete safety solution to meet the NFPA 70E standard. When speaking with a potential customer... 1. Do you know what NFPA is? NFPA stands for National Fire Protection Association. Codes and standards to reduce worldwide burden of fire and other hazards on the quality of life. 2. Are you familiar with the NFPA 70E standard? The NFPA 70E Standard for Electrical Safety in the Workplace is designed to establish an electrical safety program and address arc flash and electric shock. The program covers protection to the employee from electrical hazards such as shock, arc flash. 3. Do you work on energized equipment over 50 volts? Lock-out Tag-out Voltage Testing Trouble Shooting NOTE: All these tasks require the appropriate PPE (Personal Protective Equipment). 4. Do you have an electrical safety program in place? NFPA 70E can provide you with a guideline to implement an electrical safety work program. You must establish a program that protects against shock and arc flash per OSHA 1910.132. Before you can establish your electrical safety work program you must determine how much hazard protection you need depending on the work you do. This hazard assessment is determined by one of the three following methods. Method 1 Use the formulas in NFPA 70E 2004 to determine your hazard assessment. Refer to NFPA 70E 130.3(a) or NFPA 70E table 130.7(c)(9)(a). Method 2 Use an industry accepted software to determine your hazard assessment. Method 3 Use a consultant firm to determine your hazard assessment. Once your hazard assessment is complete you will know your Hazard Risk Category (HRC) which is given in a number ranging from 0-4. Then the proper protective apparel for the job can be determined by utilizing this HRC number. Please refer to NFPA 70E 2004 Table 130.7(C)(10) and Table 130.7(C)(11) for this information. 2 e-mail info@whsalisbury.com www.arcsafety.com

The Salisbury Solution: Providing customers with a complete line of protective clothing and equipment to meet all your safety requirements. The Arc Protection System PPE (Personal Protective Equipment) Use your assessed HRC or appropriate ATPV (Arc Thermal Protective Value) PPE protection when purchasing these protective garments. Refer to NFPA 70E 2004 Table 130.7(c)(ii) to determine your minimum ATPV for your assessed HRC. Face, Head and Eyes The face and head are protected with faceshields, hard hats, protective inner lining hoods, external protective hood, safety glasses and full coverage hoods with built in shields ranging from 8 cal/cm² - 100 cal/cm² protection. AS1000HAT TS56005B JSHV1BL AFHOOD FH31RB Body Protection The upper body is protected by flash jackets, coats, and coveralls. The clothing ranges in protection from 8 cal/cm² - 100 cal/cm². The lower body and legs are protected by bib overalls and coveralls ranging in protection from 8 cal/cm² - 100 cal/cm². ACC3132RB ACCA11BL ACB4030GY ACAIR102 Additional Comfort Salisbury offers the compact PRO-AIR belt mounted POWERED AIR SYSTEM for additional comfort while wearing Salisbury PRO-WEAR Arc Flash Protective Clothing. This system is designed to provide purified forced ambient air through filters/ cartridges that remove contaminants, providing clean air and comfort to the user. Use this unit with Salisbury PRO-HOODs. e-mail info@whsalisbury.com www.arcsafety.com 3

5. Do you have protection against electric shock? rubber insulating gloves rubber insulated matting insulated tools NOTE: All these items protect against potential electric shock. 6. Do you have rubber insulating gloves? Hand Protection Rubber insulating gloves worn with leather protectors protect workers when there is danger of electric shock. Rubber Insulating Gloves shall be worn at all times while working on energized equipment 50 volts or higher. The solution to electrical safety always begins with rubber insulating gloves. Rubber Gloves are the most important piece of equipment for electrical worker s safety. Salisbury offers a wide range of high voltage (7,500V - 36,000V) and low voltage (500V - 1,000V) rubber insulating gloves. Salisbury s Type II low voltage gloves are available in blue. Contrasting colors makes inspecting for cuts and tears easier. Type I low voltage and high voltage gloves come in a wide variety of colors and styles. Salisbury also offers glove liners which increase the comfort of wearing rubber gloves in all seasons. Rubber insulating gloves are available in six ASTM defined voltage classes. The chart on page 8 identifies the class, proof test voltage and maximum allowable exposure voltage. low voltage gloves high voltage gloves Type I - natural (non-ozone resistant) rubber Type II SALCOR - synthetic rubber (resistant to ozone) Both provide electrical workers with the highest level of electrical insulating protection. However, in order to maintain this level of protection and ensure long life, it is essential that rubber goods are properly cared for. Before each use, rubber goods should be visually inspected for holes, embedded wires, rips or tears, ozone cutting, UV checking and signs of chemical deterioration. For additional information, refer to ASTM F1236, standard guide for visual inspection of electrical protective rubber products. 4 e-mail info@whsalisbury.com www.arcsafety.com

Leather Protector Gloves should always be worn over Rubber Insulating Gloves to provide the needed mechanical protection against cuts, abrasions and punctures. All Salisbury protectors are ergonomically designed to ensure a proper fit over Rubber Gloves. PROTECTOR SELECTION CHART Clearance Table Glove Min. Distance Between Class Tops of Protectors and Rubber Gloves in. mm 0, 00 1/2 13 1 1 25 2 2 51 3 3 76 4 4 102 Proper storage extends the service life of rubber insulating gloves. Folds and creases may strain rubber and cause it to crack from ozone prematurely. By storing rubber gloves in the right size bag, and never forcing more than one pair into each bag, equipment will last longer. 6a. If you have rubber insulating gloves... Are you inspecting your insulating equipment before each use? OSHA 1910.137(b)(2)(ii) states Insulating equipment shall be inspected before each day s use and immediately following any incident that can reasonably be suspected of having caused damage. Insulating gloves shall be given an air test, along with the inspection. Salisbury offers glove inflators to easily inflate your gloves for inspection. Are you electrically testing your insulating gloves every six months per OSHA 1910.268(f)(2)? Issued gloves need to be electrically tested every six months per ASTM F496-02 In-Service Care for Insulating Gloves and Mittens specifications. 7. Do you have dielectric footwear? Foot Protection Dielectric footwear is available as additional protection for the worker. Salisbury G-99 Glove Inflator provides an excellent tool to inspect gloves. 21406 21405 e-mail info@whsalisbury.com www.arcsafety.com 5

Additional PPE (Personal Protective Equipment) 8. Do you have insulated tools? Salisbury offers PRO-TOOL Insulated Tools & Tool Kits. These tools are all tested to 10,000 VAC for use up to 1,000 VAC and meet or exceed ASTM F1505-01 and IEC 900 Standards for Insulated Hand Tools. This product is necessary to be compliant with OSHA 1910.333 (c)(2), and NFPA 70E 2004. The insulating material used is impact resistant and flame retardant. Two-color insulation makes inspection easier which adds to the overall safety. 9. What other types of equipment protect a worker from phase to phase or phase to ground contact? Salisbury offers many other protective equipment options such as insulating blankets, low voltage insulating blankets, slotted blankets, insulated matting, roll blankets and clear PVC roll blankets. roll blanket slotted blanket low voltage blanket Grounding Equipment Grounding equipment is essential to the electrical worker s safety while working on a de-energized equipment or lines. Salisbury offers a full line of grounding equipment available for industrial applications. Salisbury products are manufactured to the highest industry standards to meet your needs and ASTM Requirements. visit www.whsalisbury.com/configurator/index.php to determine which grounding components you will need to meet your systems requirements. 6 e-mail info@whsalisbury.com www.arcsafety.com

Insulated Rescue Hook The Insulated Rescue Hook is an invaluable tool for any workplace. It s used to withdraw an injured worker out of a hazardous area. Confined spaces, in vaults, or just near electrical cabinets and switch gear are some of the places where this tool is a must. 24401 Voltage Detectors Self-Testing Voltage Detectors allow testing to be continuous and automatic. An intermittent flash and beep confirms the detector is functioning properly. Self- Testing Voltage Detectors are used to verify live or de-energized conductors. These testers may be used with rubber insulating gloves or hot sticks 4556 using the splined universal end fitting. NOTE: Always test prior to work. Static Discharge Stick Some equipment will retain or store energy that needs to be removed. The Static Discharge Stick is designed to safely remove the static charge after de-energizing. 20817 22629 e-mail info@whsalisbury.com www.arcsafety.com 7

ASTM Chart Rubber and SALCOR Protective Equipment Rubber insulating gloves are available in six ASTM defined voltage classes. Rubber insulating sleeves are available in Class 0 through 4. The chart below identifies the class, proof test voltage and maximum allowable exposure voltage. ASTM Labeling Chart for Salisbury Linemen s Natural Rubber and SALCOR Rubber Protective Equipment Proof Test Max. Use Rubber Class Voltage Voltage Molded Glove Label Rubber Dipped Color AC / DC AC / DC* Products Sleeve Label Label 00 Beige 2500 / 10,000 500 / 750* 0 Red 5,000 / 20,000 1,000 / 1,500* 1 White 10,000 / 40,000 7,500 / 11,250* 2 Yellow 20,000 / 50,000 17,000 / 25,500* 3 Green 30,000 / 60,000 26,500 / 39,750* 4 Orange 40,000 / 70,000 36,000 / 54,000* *Maximum use DC voltage is not part of any ASTM specification. Maximum use DC voltages are valid in reference to IEC 903 only. Gloves and Sleeves must have a color coded label. Suitable for live working. IEC60903:2002 & IEC60417 fig. 5216 8 e-mail info@whsalisbury.com www.arcsafety.com