Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

Similar documents
esense CO2 Transmitter and Alarm

Installation Manual KS8-LCP 0-10 C0 2 TRANSMITTER. Instructions for :- KS8-LCP0-10 C02 Sensor

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

C7232A,B Sensor and Controller

Product Catalogue. Air and Gas Sensors. Save Life and Energy

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Warranty Registration

INSTALLATION AND OPERATING INSTRUCTIONS

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

RE-PR3-E-27 3-Phase Panel Mount 27kW

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Accuracy by Design Products for the HVAC Professional

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

Duct and Rough Service Carbon Monoxide Sensor

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

DMFPM-2R MULTIFUNCTIONAL

Datasheet: K-22 LO Sensor

Snifter ATEX22 VERSION. User Manual. Distributor

QPM21 Series Duct CO 2 and Air Quality Sensors

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Visit us at

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

RSMFM-2R MULTIFUNCTIONAL

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

KANE-ALERT-CO 2 Monitor with Temperature

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

WRF04 CO 2 RS485 Modbus

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Analog Room Pressure Monitor RPC Series

WIO200 Water In Oil measuring instrument

! WARNING. Before using product, read and understand instructions.

EC3-X33 Stand-alone Superheat Controller Technical Data

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Two-Channel Gas Controller

0-10 V Wall & Duct Humidistat Installation Instructions

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

M3050 Detector Operator s Manual

CMF, CMX & CMA series

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

CD-Px Series Duct Mount CO 2 Transmitters

Duct Air Quality Sensors

Beck. The differential pressure transmitter for air

General Specifications

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Forced draught gas burner

Carbon Monoxide Transmitter

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Alfa Laval Potentiometric Level Transmitter

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

KR Series Air Defrost Unit Coolers Operating and Installation Manual

EC3-X33 Stand-alone Superheat Controller

Bravo. Troubleshooting Guide

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

XgardIQ Duct Mounting Kit

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

ELECTRONIC HUMIDISTAT: H270

PA ma Loop Powered Level Preamplifier

A99B Series Temperature Sensors

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

RS Pro Infrared Temperature Sensor

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

TER Active Room Temperature Sensor (Controller),

Room Air Quality Sensors

Duct Temperature Sensors

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

! WARNING. Before using product, read and understand instructions.

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

gas monitoring system

HVAC Sensors Catalogue

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER

IGD.CO.UK

Transcription:

Gas and Air Sensors Installation Manual esense Duct (Disp) General Figure 1 The esense Duct with and without display The IAQ-sensor product esense Duct (for mounting in ventilation ducts) is designed to measure carbon dioxide (CO 2 ). Option - TR is prepared for temperature measurements by the resistive temperature probe mounted by the user. Option -Disp displays the measured CO 2 value in ppm (parts-per-million) on the LCD. The units are designed for connecting to Direct Digital Control (DDC) with 0-10V or 2-10V signal inputs. The two parallel signal outputs Out(1) (0-10V) and Out(2) (2-10V or 4-20 ma) give linear signal voltages or currents corresponding to the measuring range. The output Out(2) also indicates the status by setting the output voltage to 1V or the output current to 2 ma when the sensor self-diagnostics detects any error. 1 (8)

2 1 1 2 3 4 5 6 9 1 Sampling probe 6 O-ring 29,2x3,53 2 Sealing gasket PCB (Factory supplied mounted in box) 3 Largest locking nob 8 Snap-in lid 4 2 washers (Not included) 9 Cable entry bushing 5 2 screws (Not included) Figure 2 Parts of the esense for duct mounting 8 2 (8)

Mounting of esense on to the duct. 10 10 Hole with 25 mm diameter Figure 3 Mounting of the sensor to the ventilation duct Mounting Instruction Since there might be a substantial pressure difference in duct mounting applications, it is essential to avoid ambient air from suction into the duct mounting box. For correct function it is indispensable that the sealing of the box cover, the cable entry bushings, the cable feed through and the duct entrance are absolutely tight. The duct entrance may need extra sealing paste in order to prevent leakage. The PCB must be handed carefully and protected from electrostatic discharge. 1) Place the O-ring around the hole at the back of the box. See figure 2. 2) Electrical cable entry: The box has a factory mounted cable entry bushing. Never feed more than one cable through each cable entry bushing, or else gas might leak through! 3) Mounting the tube: Drill a hole (10) with 25 mm diameter (or 1 inch) for the sampling probe and two holes with 4 mm diameter for the screws (5) into the air duct and mount the tube (1) with the gasket (2). The sampling probe should be mounted with the largest locking knob on top. The unit can be mounted with the air coming from the left or right. 4) Attaching the sensor box is made to the sampling probe by a snap-in bayonet fitting. Orient the box onto the sampling probe so that the box upside is on the same side as the largest locking knob (3). When the probe is fitted into the notches of the box, then turn the box clockwise until stop (see Figure 2). Position 1 indicates open where the box can be removed from the sampling probe. In position 2 the box is locked to the probe. 3 (8)

Electrical connections The power supply has to be connected to and. is considered as system ground. The same ground reference has to be used for the esense unit and for the DDC/signal receiver. + PLEASE NOTE! The same ground reference has to be used for the esense unit and for the control system! Terminal Function Electrical data Remarks Standard settings + Power (+) 24 VAC/DC+ (+- 20%), 2W Remarks Settings of this sensor Out(1) Power ground (-) Analogue output 1 (+) 24 VAC/DC- System voltage reference 0-10 VDC or 0-2000 ppm CO 2 According to label Out(2) Analogue output 2 (+) 2,0 10,0 VDC or 4,0 20,0 ma or According to label 0-2000 ppm CO 2 0,9 1,6 VDC or 1.5 to 2,5 ma Status = ERROR 0 VDC or 0mA Status = NOT READY Table I. Connections of the main terminal of esense 4 (8)

+ Option display Figure 4 PCB with jumper to configure OUT2 for current output 4-20mA or voltage output 2-10VDC + Figure 5 Enlarged picture of the PCB with the jumper set to current output (left position) + Figure 6 Enlarged picture of the PCB with the jumper set to voltage output (right position) Self-diagnostics The system contains a complete self-diagnostic procedure that is executed automatically when the sensor is in operation. Sensors with display show a wrench if an error is found. The wrench is shown during the first seconds after power up and if the measuring range is exceeded. The output Out(2) indicates the same information by setting the output voltage to 1V or 2 ma. 5 (8)

Maintenance The esense is basically maintenance free in normal environments thanks to the built-in self-correcting ABC algorithm. Discuss your application with SenseAir in order to get advice for a proper calibration strategy. PLEASE NOTE! The sensor accuracy is defined at continuous operation (at least 3 weeks after installation) PLEASE NOTE! Electronic products should be disposed of via a suitable recycling centre. 6 (8)

Dimensions Figure The dimensions of the sensor in mm and (inches) (8)

This product is in accordance with the EMC 2004/108/EC, 92/31/EEG including amendments by the CE-marking Directive 93/68/EEC The product fulfils the following demands: EN 61000-4-2 level 2, EN 61000-4-3 level 2, EN 61000-4-4 level 4, EN 61000-4-6, EN 61000-4-8 level 4, EN 55022 class B SenseAir AB (headquarter) Stationsgatan 12 Phone: +46-(0)653-1 0 Box 96 E-mail: info@senseair.com 820 60 Delsbo SWEDEN Web site: www.senseair.com 8 (8)