CP+ Gas & Oil Cabinet Heater Range

Similar documents
VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

PT Radiant Heater Range

Powrmatic PZN / PZN X Hot Water Heater

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

HEM Heat Exchange Modules

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

VPC Gas Cabinet Heater Range

NVxEA External Gas Unit Heater

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

NVx Suspended Gas Unit Heater

Powrmatic Control Systems Industrial & Commercial Heating Systems

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

CPx Gas & Oil Cabinet Heater Range

Destratification Fans Industrial & Commercial Heating Systems

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

BENSON.... Variante3 Fired Unit Heaters...

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

PREEVA air handling unit

Installation Instructions

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

BENSON VARIANTE 2 RANGE

Powrmatic PQ Electric Quartz Infrared Heaters - A Range

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Sirius FS. Working towards a cleaner future

BENSON VARIANTE 2 RANGE

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

CPx Gas or Oil Cabinet Heater Range

Flue & Flue Kits for NVx, VPC & NVS

NVx Suspended Gas Unit Heater Range

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

The NCA-G Range. Installation and Servicing Instructions WARNING: THIS APPLIANCE MUST BE EARTHED

Exhaust Duct Design Page 1 of (C)

CP Range. Users, Installation & Servicing Instructions Gas & Oil Fired Heaters TESTED

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

INSTALLATION & SERVICING MANUAL FOR HARRY TAYLOR VARIANTE² BI DIRECTIONAL NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Installation and Operating Manual Drying Cabinet

Gas heaters and convectors ROBUR

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

SB Range Universal Oil Heaters with Automatic Ignition

Gas-fired unit heaters for indoor installation

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

The NCE-AG and CPE-AG Ranges Range

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Warm Air Cabinet Heaters

CECx Destratification Fan

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Pressure Jet Boilers. Pressure Jet Range. Commercial Heating Solutions.

OUH Suspended Oil Unit Heater

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

HEC - High Efficiency Condensing Heaters. Warming the workplace. 12kw to 1000kw Efficiency of up to 109% Nett High/Low or Fully Modulating Heater

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

range W, Plus Condensing boilers kW Commercial & Industrial Boilers

BENSON HEATING INSTALLATION OPERATION AND SERVICING MANUAL

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

INSTALLATION & SERVICING MANUAL FOR BENSON PV TUBULAR CABINET HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

RHC GAS FIRED HEATING COILS

Condensing Boilers. Floor Mounted - Evomod, Imax Xtra & Imax Plus III. Commercial Heating Solutions.

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

BENSON LINEAR RADIANT TUBE

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

... UDSA - UDSBD Gas fired unit heaters...

CPx Gas & Oil Cabinet Heater Industrial & Commercial Heating Systems

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Cast Iron Boilers. G Series ( kW)

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Drying Cabinet Installation and Operating Manual

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Transcription:

CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS

CP+ Overview Designed without Compromise Six model options 366 kw - 1025 kw output Vertical or horizontal configurations Oil, natural gas, LPG and biodiesel (B10) fired External static pressure options up to 1000 Pa Stainless steel combustion chamber and heat exchanger as standard Galvanised and powder coated outer panels Penta Post aluminium frame construction Burners & Fuel Options Powrmatic CP+ heaters are matched to pressure jet oil and forced draught gas burners. Gas fired units are certified for use on Natural Gas, Group H -G20, Group L - G25 and Propane - G31. Oil fired units are supplied as standard for use with 35sec fuel and can be supplied for use with 28sec fuel as an option. In accordance with guidelines from our burner supplier,, the burners fitted to Powrmatic oil-fired heaters are suitable for fuels with a bio content of up to 10% only (B10). For fuels with a bio content of more than 10%, please consult our Technical Department. Caring For The Environment High efficiency models Biofuel options Peace Of Mind More than sixty years experience in warm air Two year parts and one year labour guarantee Ten year combustion chamber/heat exchanger warranty Application & Configuration Powrmatic CP+ cabinet heater range covers six models with outputs from 366 kw to 1025 kw. Heaters can be supplied in either upright or horizontal configuration and can be internally installed directly into the space to be heated or sited in plant rooms. In addition, the heater can be specified in CP+EA configuration. EA configured heaters are suitable for external locations and are weatherproofed to IP44 standard. Both oil and gas fired heaters have high/low burners as standard and modulating gas burners are available an extra cost option. Efficiencies Favourable levels of fuel usage and reduced emissions are a key element of CP+ heater design. Additionally, heaters have efficiencies which meet or exceed the requirements of current UK Part L Building Regulations. Efficiencies can be further enhanced with the selection of modulating burners. Cabinet To ease transportation and installation, the heater comprises of separate fan and heat exchanger sections. Each section is of frame and panel construction. Heat exchanger section panels are fully insulated being filled with high density mineral wool. All heaters have the benefit of a galvanised skid base frame. Internal heaters have the benefit of stove hardened epoxy powder coat paint finished to our standard RAL 6027 colour whilst external CP+EA units have the benefit of enhanced weather resistance by the application of a full polyester spruce green coating to BS 12-B-25. Combustion Chamber The drum type chamber is fabricated from AISI430 stainless steel coupled to a tubular heat exchanger also manufactured from stainless steel. Air Movement Via dynamically balanced centrifugal fan sets with belt driven motors offering a choice of 300, 600 or 1000 Pa external static pressures. As standard, internal CP+ heaters are arranged for ducted applications and are provided with an outlet spigot for the onward connection of ductwork. Unless otherwise specified return air is via louvred intake panels. External heaters are also provided with a duct outlet spigot and louvred intake panels. All heaters can be specified with alternative return air spigots, dampers and filter boxes. Freeblowing internal heaters are optional, details on request from our sales office. Controls Heaters are supplied ready for automatic operation and are complete with safety and comfort controls. As standard heaters will be provided with the optimised entry code protected control MC200V3 (required for high/low and modulating applications) which includes a digital time switch, electronic day thermostat and frost protection thermostats. Remote temperature sensor option available. Alternatively heaters may be specified with our Powrtol control, which has a digital time switch, mechanical day temperature and night set-back thermostats. Internal upright heater controls are factory fitted whilst horizontal and all external heaters are supplied with a remote console (inter-connecting wiring by others). It is recommended that all external heaters installed where the ambient temperature is likely to be below -5 C are specified with the optional low temperature kit which provides additional protection for the burner and control components. All heaters have the ability to provide fan only summer air movement. Approvals All Powrmatic heaters are type tested to meet the stringent requirements of the Gas Directive and are CE approved. 2

Duties CP+ Output kw 366 440 586 732 879 1025 Input kw 395.7 475.7 633.5 791.4 950.3 1108.1 Design Efficiency % 92.5 Temperature Rise C C 45 Air Volume m 3 /s 6.49 7.88 10.5 13.1 15.75 18.37 m 3 /h 23364 28368 37800 47160 56700 66132 Option 1 Pa 300 Airside Performance Ducted Units Fan Static Option 2 Pa 600 Option 3 Pa 1000 Supply V/ph/Hz 400/3/50 Option 1 300 Pa Motor kw 11 11 15 15 18.5 30 Electrics Option 2 600 Pa Motor kw 15 15 18.5 22 30 40 Option 3 1000 Pa Motor kw 18.5 22 30 30 40 55 Burner Burner Burner High - Low Gas (Standard - Gas Fired) Modulating Gas (Optional) High - Low Oil (Standard - Oil Fired) RS44 RS44/M RL44 RS50 RS50M RL50 RS70 RS70M RL70 RS100 RS100M RL70 RS100 RS100M RL100 RS100 RS100M RL100 Connection Oil V/Rc ⅜ ½ Gas BSP/Rc 1½ 2 Minimum Nat Gas mbar 17.5 Fuel Inlet Pressure LPG mbar 37.0 Consumption Oil kg/h 33.4 40.1 53.4 66.7 80.1 93.4 Standard Nat Gas m 3 /h 41.90 50.3 67 83.7 100.6 117.3 Outputs LPG m 3 /h 16.2 19.5 25.9 32.4 38.9 45.3 Height mm 3050 3200 3500 3750 4000 4250 Overall Dimensions UD Upright Ducted Width mm 1150 1400 1700 1800 Depth mm 1950 2200 2750 3000 3600 4000 Front mm 1950 2200 2750 3000 3600 4000 Installation Clearances UD Upright Ducted Side mm 1000 1000 1000 1000 1000 1000 Rear mm 1000 1000 1000 1000 1000 1000 Flue Diameter mm ø 250 300 300 350 400 Notes - Fuel consumption and output figures based upon nett calorific values as follows - Class D light distillate fuel oil nett CV 36.28 MJ/l - Natural gas (G20) nett CV 34.02 MJ/m³ - LPG Propane (G31) nett CV 95.65 MJ/m³ Alternative or more specific fan static pressures available, please contact the sales office for further details Air handling data is assessed at room ambient conditions. Dimensions and clearances in table above refer to upright heaters only - for horizontal heater dimensions refer to dimensions page and for clearances refer to the relevant O&M manual Noise levels measured 3m from appliance and in free field conditions Installer guidance notes on rear page Overall dimensions in the above table do not include burner dimensions 3

Dimensions CP+ Internal Heater - Upright (All measurements are in mm) Length A 1950 2200 2750 3000 3600 4000 Width B 1150 1400 1700 1800 Overall Height C 3050 3200 3500 3750 4000 4250 Flue Diameter D 250 300 350 400 Fan Section E 900 1000 1300 1500 Exchanger F Section 1600 1950 1950 2200 2250 2500 Burner Length G - Gas 580 840 Burner Length G - Oil 468 680 4

Dimensions CP+ Internal Heater - Horizontal (All measurements are in mm) Width A 1950 2200 2750 3000 3600 4000 Height B 1350 1600 1900 2000 Overall Length C 2800 3250 3550 4000 4050 4400 Flue Diameter D 250 300 350 400 Fan Section E 1200 1300 1600 1800 1800 1900 Exchanger F Section 1600 1950 1950 2200 2250 2500 Burner Length G - Gas 580 840 Burner Length G - Oil 468 680 5

Dimensions CP+ External Heater - Upright (All measurements are in mm) Length A 1950 2200 2750 3000 3600 4000 Width B 1150 1400 1700 1800 Overall Height C 3050 3200 3500 3750 4000 4250 Flue Diameter D 250 300 350 400 Fan Section E 900 1000 1300 1500 Exchanger F Section 1600 1950 1950 2200 2250 2500 Burner Enclosure G - Gas 700 1000 Burner Enclosure G - Oil 600 800 Overall H - Gas 2650 2900 3750 4000 4600 5000 Overall H - Oil 2550 2800 3550 3800 4400 4800 6

Duties CP+ External Heater - Horizontal (All measurements are in mm) Width A 1950 2200 2750 3000 3600 4000 Height B 1350 1600 1900 2000 Overall Length C 2800 3250 3550 4000 4080 4400 Flue Diameter D 250 300 350 400 Fan Section E 1600 1300 1300 1800 1800 1900 Exchanger F Section 1600 1950 1950 2200 2250 2500 Burner Enclosure G - Gas 700 1000 Burner Enclosure G - Oil 600 800 Overall Width H - Gas 2650 2900 3750 4000 4600 5000 Overall Width H - Oil 2550 2800 3550 3800 4400 4800 7

Your Installer Guide General The following notes are provided as a guide, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. For copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Standards All Powrmatic CP+ and CPEA+ heaters must be installed, commissioned and operated with due regard to appropriate regulations including but not limited to BS 6230, BS5410 1998, relevant Codes of Practice, the possible requirements of Local Authorities, Fire Officers and insurers as well as Powrmatic s installation manual. Position & Location Heaters should be installed on a level non-combustible base. Horizontal heaters can be mounted directly on their skid base-frame or on a supporting structure. It is important that all supporting structures have due regard to the relevant weight loadings. To assist installation, the heaters are generally supplied with separate fan and heat exchanger sections in which case on-site assembly will be required. Consideration should however be given to the means of moving the component parts within the site and necessary mechanical handling for assembly. External heaters are specifically designed for outside locations and should not be installed within partially enclosed areas or under canopies which may restrict the operation of the heater or evacuation of flue gases. If an external heater is to be located in any area which is partially or fully enclosed then it is recommended that you consult our technical department. Consideration should also be given to flue routes and points of exit, gas, oil, electrical and, where applicable, control connections, issues of public access and in the instance of remote temperature sensors the position need to be representative of the zone temperature to which they refer. Heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn into the combustion air or main fan circuits Areas where special consideration or advice may be required could include but is not limited to Where de-greasing solvents are present, even in minute concentrations Where paint spraying is carried out Where styrenes or other laminating products are used Where airborne silicone is present Where petrol engined vehicles are stored or maintained Where dust is present (i.e. wood working or joinery shops) Where high levels of extract persist Installation in such areas may be possible under specific conditions. Please consult our technical department for further information. Installation Clearances Particular clearances may be necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. Powrmatic Limited Hort Bridge Ilminster Somerset TA19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk Plant Room or Enclosure Locations Specific requirements exist where heaters are to be installed within plant rooms or enclosures. Such requirements cover the provision of positive ductwork connections as well as ventilation for combustion air and general plant room or enclosure ventilation. It is recommended that you consult with our technical department or the installation manual prior to installation. Combustion Air & General Ventilation Within the United Kingdom mandatory regulations apply concerning the provision of combustion air and general heater ventilation for all internally located heaters. Where a heater is installed within the heated space and where that heated space has a natural ventilation rate greater than 0.5 air changes per hour, then combustion air and general heater ventilation is probably not required. If the heated space has a natural ventilation rate of less than 0.5 air changes per hour then either natural ventilator openings or mechanical ventilation will be required. Please consult the installation manual for further details. External heaters located in unrestricted outside areas will generally source combustion air from the surroundings and as such no additional requirements should be necessary. Flue For internally located heaters each heater requires a separate flue system of the appropriate size. The flue should essentially be installed in the vertical plane and the number of bends kept to a minimum. The flue must be adequately supported and terminated with a suitable cowl, with due regard to the point of exit and it s proximity to any windows, doors or ventilation intakes etc. External heaters are supplied complete with a primary flue section and cowl which provides the direct discharge of flue gases directly to atmosphere. Care should be taken to ensure that the flue discharge is not in anyway restricted or the exit point could result in flue gases entering the building. If the application requires, it may be possible to extend the flue to enable the point of discharge to be repositioned. However, should this be necessary then the diameter of flue must not be less than stated in the data sections of this brochure. Pipework Care should be taken when sizing pipework to ensure that minimum gas and maximum oil inlet pressures are not compromised under dynamic load conditions. Isolating valves and service unions should be provided for each heater and pipework installed with due regard for relevant standards and Codes of Practice. Guarantee Powrmatic CP+ heaters are provided with a comprehensive guarantee covering both the heater and the heat exchanger. For United Kingdom sales the heater has the benefit of a two year parts and one year labour guarantee whilst the heat exchanger assembly has a ten year time related warranty. All guarantees are subject to terms and conditions. Powrmatic Ireland 45 Broomhill Close Tallaght Dublin 24 tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. Issue 5.2 September 2015