Installation Operation Maintenance Instructions

Similar documents
Installation, Operation and Maintenance Manual

Fan Motor. user manual INSTALLATION - OPERATION - MAINTENANCE

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Installation, Operation and Maintenance Manual

Copy Right By: Thomas T.S. Wan

CORTEC. CORTEC

Belt Driven Mixed Flow Fans

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

p Permanent magnet water cooled motors Additional manual

cooling tower downtime instructions

XC-18. NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard.

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

Installation Instructions U-RAD-LT Electric Radiant Heaters

WHEELED STORED PRESSURE

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

Annual Tune-Up Procedure

Downtime Instructions

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

Evaporative Cooling products

LC Series - Light Commercial Pump Station Installation and Operation Manual

www. ElectricalPartManuals. com INSTRUCTIONS DRY TYPE TRANSFORMERS OPERATION AND MAINTENANCE OF

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS

SECTION AIR HANDLING UNIT

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

Care and maintenance instructions for products supplied by VEKSØ A/S

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

THERMAL SYSTEMS, INC. Installation and Operation Manual

Register at

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Solid Door Top Mount Reach-In Freezer

Unpacking Your Fan 2.

Pot Belly Black. Overview. Suitable Surfaces

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

ELECTRIC HEDGE TRIMMER

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Enviro KES INSTALLATON MANUAL

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Dual Function SMART VENT. Superior Flood Protection and Natural Air Ventilation SMART VENT - Model:

WALLPAPER STEAMER. Model ASSEMBLY AND OPERATING INSTRUCTIONS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

WINTERIZATION DRIP IRRIGATION SYSTEM

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Cavitator Ultrasonic Cleaners

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Electric Cruise Line Single Broiler w/ Cabinet Base CLB V CLB V

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

OPERATOR S MANUAL. For BURLY ATTACHMENTS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

DC Motor Blower Kit Frames DC180ATZ and C180ATZ thru C400ATZ Installation & Operating Manual

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

SLS Etch Primer. 300g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

Panel Fan Series Operators Manual (Galvanized and Polymer)

Glass Door Merchandiser Refrigerator and Freezer

Cavitator Ultrasonic Cleaner Instruction Manual

Heat Transfer. the new standard in. Heat Exchangers. Storage, Installation, Operation and Maintenance

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

English BT3600

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

AXPR Wall Mounted Axial Panel Fans

KCC Centrifugal Fan Air Cooled Condensers

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

SECTION STEAM CONDENSATE PUMPS

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

Operating / User Manual

Installation, Operation and Maintenance Manual for B&G U Series Heat Exchangers Removable Bundle Design BELL & GOSSETT.

SECTION XXXXX POSITIVE DISPLACEMENT BLOWER WITH SOUNDSEAL COMPACT ENCLOSURE

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

It is critical to maintain the Beech Oven and associated equipment on a regular basis, to avoid the possibility of a serious fire or malfunction.

Installation and assembly instructions. for standard configuration radial blowers

Easy-Lam School Budget Roll Laminator

PORTABLE HAND POWER THREADER 1/2-2

Installation & Maintenance Instructions

Induction K heater

Metal, ceramic, plastic package products

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

IMpORTANT SAFETy INSTRUcTIONS

Transcription:

Installation Operation Maintenance Instructions Storage Recommendations Induction Motors Integral Horsepower

TABLE OF CONTENTS INTRODUCTION............................. 3 SAFETY PROCEDURE......................... 3 INDOOR STORAGE Wholly Controlled Atmosphere Requirements.............................. 4 Preparation................................ 4 Maintenance.............................. 4 Partially Controlled Atmosphere Preparation................................ 4 Maintenance.............................. 5 OUTDOOR STORAGE Inland Dry Climate Preparation................................. 6 Maintenance............................... 7 Inland Humid Climate Preparation................................ 8 Maintenance.............................. 9 Salty and Industrial Atmosphere Preparation................................. 9 Maintenance.............................. 10 PREPARATION FOR SERVICE Cleaning.................................. 11 Meggering................................ 11 The information contained within is intended to assist operating personnel by providing information on the general characteristics of the purchased equipment It does not relieve the user of the responsibility of using accepted engineering practices in the installation. operation and maintenance of this equipment. Should a conflict arise between the general information in this manual and the contents of the drawings and supplementary material, the latter shall take precedence. The illustrations in this book show typical motors. Special features will deviate from those pictured.

INTRODUCTION page 3 The purpose of this booklet is to offer some short, easy- tofollow recommendations to our customers, users, and distributors for the proper care of electric motors in storage. For practical purposes, such equipment is considered to be in storage not only when it is in the storeroom but also when: It has been delivered to the jobsite and is awaiting installation; or, it has been installed but regular operation is delayed pending completion of plant construction; or, there are long, idle periods between operating cycles; or, the plant or department is shut down. The recommendations given here apply to conditions commonly found in indoor storage. Personnel responsible for care of the equipment should use good discretion in adapting these recommendations to the particular situation. Common sense and sound safety rules need to be followed. Recommended brand products have shown good performance. Siemens, however, cannot assume responsibility or be liable for products other than those it warrants. Distributors of products listed are: Tectyl 502-C and 506: Valvoline Oil Co. Div. of Ashland Oil and Refining Co. 150 Fourth Avenue Freedom, Pennsylvania 1 5042 PD. George 11137: Insulation Manufacturers Corp. 123 Superior Avenue, N.E. Cleveland, Ohio 44114 SAFETY PROCEDURE WARNING Dangerous voltages are present in the motor components which can cause serious injury, electrocution and equipment damage. To avoid serious injury and/or equipment damage before any adjustments, servicing, wiring, parts replacement or any other act requiring physical contact with the electrical or mechanical working components of this equipment is performed, all equipment must be de-energized, disconnected and isolated to prevent accidental contact with live or rotating parts. The success and safe operation of motors is dependent upon proper handling, installation, operation and maintenance, as well as upon proper design and manufacture. Failure to follow certain fundamental installation and maintenance requirements may lead to personal injury and the failure and loss of the motor as well as damage to other property. Only qualified personnel should be involved in the inspection, maintenance and repair procedure and all plant safety procedures must be observed. A qualified person is one who is familiar with the installation, construction and operation of the equipment, and the hazards involved. In addition, he has the following qualifications: a. Is trained and authorized to energize, de-energize, clear, ground, and tag circuits and equipment in accordance with established safety practices. b. Is trained in the proper care and use of protective equipment such as rubber gloves, hard hat, safety glasses or face shields, flash clothing, etc., in accordance with established safety practices. c. Is trained in rendering first aid. Motor should be installed and grounded per local and national codes.

page 4 INDOOR STORAGE (Up to 5 Years) WHOLLY CONTROLLED ATMOSPHERE Conditions Required Uniform temperature (between 40 F and 140 F) throughout the room maintained at least 10 F above the dew point. Relative humidity of 50% or less. Dust accumulation to be little, no harmful fumes and little or no ambient vibration PREPARATION Units with these types of bearings are shipped without lubricating oil. A film of rust-inhibiting oil protects the bearings and shaft journals during shipment, but this protection does not last for extended periods of storage; therefore, before placing the unit in storage longer than one (1) month, fill the oil wells to running level, using a good grade of rustinhibiting lubricating turbine oil. Vertical Machines having these types of bearings, and operating at 1800 RPM or slower, are designed so that the oil completely covers the bearings when properly lubricated. Vertical machines for faster operation (3600 RPM) use an oil-mist lubrication system requiring the bearings to be located above the normal oil level. NO LUBRICATING OIL IS SHIPPED WITH ANY OF THESE UNITS; only a film of rustinhibiting oil is applied at the factory. To protect the bearings for storage, fill the oil wells to running level with a good grade of rust-inhibiting lubricating turbine oil; units with oilmist lubrication and Kingsbury type bearings need to be run at operating speed for two minutes every three (3) months so that the bearings receive a new film of protective oil; otherwise, the motors must be partially disassembled to reach the bearings and coat them with oil every three (3) months. Ball or roller bearing units are shipped from the factory with the bearings properly packed with grease and require no further preparation. Shaft Extensions and Exposed Machined Surfaces Surfaces should be coated with an easily removable rustpreventative, such as Tectyl No. 502-C. Rodents and other animals, like to house inside motors in search of warm surroundings or food. Some of them attack the insulating materials. Their access to the motor should be restricted. MAINTENANCE Once a month the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Every three (3) months the 3600 RPM Vertical, and all Kingsbury type machines should be run for two minutes to recoat the oil-mist lubricated bearings. If the unit cannot be run it must be partially disassembled to reach the bearings and coat them with oil, by hand. The oil itself need not be renewed. Vertical machines operating at 1800 RPM or slower, are designed so that the oil completely covers the bearings when properly lubricated. Every two (2) months the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Every two (2) months the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Bearings should be relubricated at two year intervals when in storage. Use the polyurea base grease of No. 2 or No. 3 consistency. (See instruction book for unit.) PARTIALLY CONTROLLED ATMOSPHERE Conditions Desirable The room selected should be as clean and dry as possible, with little or no ambient vibration. PREPARATION Motors stored in ambients below 40 F and above 140 F should be stored in an enclosed ventilated structure. Space heaters must be energized. The enclosing structure should be designed to protect the motor from flying debris or other damage from high winds. Disassemble main parts of motor and clean them thoroughly. Keep the lubricant where it belongs; do not remove or contaminate it. In open motors, coat the exposed machined surfaces of the rotor with a non- hardening protective film, such as Tectyl No. 502-C, which is easily removed with petroleum solvents during service preparation. Coat the rotor air-gap surfaces lightly.

page 5 Do not put Tectyl Film on the bearings. When storage may last over one year, repaint all surfaces previously painted before reassembling. Remove the condensation drain plugs from those units equipped with them, and insert silica-gel plugs into the openings. Insert one-half pound bags of silica-gel, or other desiccant material, into air inlets and outlets of drip-proof or splash-proof open motors. The bags must remain visible so that they will be noticed and removed when the unit is prepared for service. Cover the unit completely to exclude dirt, dust, moisture, and other foreign materials. At a bare minimum, a heavy water-proofed cover should be slipped over it. If the unit cannot be moved from its base, and more elaborate protection is desired, all the openings can be covered with an adhesive plastic cloth and the entire unit sprayed with a peelable plastic. Specifications for this material can be secured from the U.S. Government. If the motor can be moved, it is suggested that the entire motor be encased in a strong, transparent plastic bag. Before sealing this bag, a moisture indicator should be attached to the side of the motor, and several bags of silicagel desiccant put inside the bag, around the motor. When the moisture indicator shows that the desiccant has lost its effectiveness, as by a change in color, the bag should be opened and the desiccants replaced with fresh ones. Whenever a motor cannot be sealed and the relative humidity is greater than 50%, long storage calls for space heaters to be installed in the unit, to maintain equipment temperatures at least 10 F above the ambient air, to prevent the harmful effects of moisture condensation. If motors are not equipped with space heaters at time of manufacture, consult factory for proper size. Units with these types of bearings are shipped without lubricating oil. A film of rust-inhibiting oil protects the bearing and shaft journals during shipment, but this protection does not last for extended periods of storage; therefore, before placing the unit in storage longer than one month, fill the oil wells to running level. Use a good grade of rustinhibiting lubricating turbine oil. Vertical machines operating at 1800 RPM or slower, are designed so that the oil completely covers the bearings when properly lubricated. Vertical machines for faster operation (3600 RPM) use an oil-mist lubrication system requiring the bearings to be located above the normal oil level. NO LUBRICATING OIL IS SHIPPED WITH ANY OF THESE UNITS; only a film of rust-inhibiting oil is applied at the factory to protect the bearings during shipment. To prepare the bearings for storage, fill the oil wells to running level with a good grade of rust-inhibiting lubricating turbine oil. Ball or roller bearing units are shipped from the factory with the bearings properly packed with grease and require no further preparation. Shaft Extensions and Exposed Machined Surfaces or Flanges Coat these surfaces with an easily removable rust-preventative, such as Tectyl No. 502-C. MAINTENANCE Rodents and other animals like to house inside motors in search of warm surroundings or food. Some of them attack the insulating materials. Their access to the motors should be restricted. Once a month the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Every three months the 3600 RPM machines and all Kingsbury type, should be run for two minutes to recoat the oil-mist lubricated bearings. If it cannot be run it must be partially disassembled and the bearings coated with oil, by hand. The oil itself need not be renewed. Vertical machines operating at 1800 RPM or slower, are designed so that the oil completely covers the bearings when properly lubricated and do not need to be disassembled. Every three (3) months the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds.

page 6 Every three months the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Bearings should be relubricated at two year intervals when in storage. Use a polyurea base grease of No.2 or No.3 consistency. (Consult instruction book for your unit.) Shaft Extensions and Exposed Machined Surfaces, or Flanges For very long storage, check the protective life of the rust inhibitor used, and recoat as recommended by the manufacturer. Tectyl No. 502-C, for example, heavily applied may last about 2 years. Desiccant plugs and bags must be checked periodically, even weekly, if the moisture is high (above 50%) and the temperature drops often. When no desiccant is being used, the correct setting of the space heaters becomes important. Make certain they function properly. Space heaters should be sized to keep the motor 10 F above the ambient temperature. OUTDOOR STORAGE (Up to 5 Years) INLAND DRY CLIMATE Conditions Usually Encountered Dust, sand, heat from the sun, and occasional rain or snow. Motors stored in ambients below 40 F and above 140 F should be stored in an enclosed ventilated structure. Space heaters must be energized. The enclosing structure should be designed to protect the motor from flying debris or other damage from high winds. Vertical machines of 3600 RPM and all Kingsbury type oillubricating bearings are shipped from the factory WITHOUT lubricating oil in the bearings. A film of rust- inhibiting oil protects the bearing during shipment. This film does not offer sufficient protection for outdoor storage; therefore, before placing in storage, fill the oil wells to running level and run the machine at operating speed for two minutes. If the motor cannot be run, disassemble to reach the bearings and coat them with the rust-inhibiting oil. Otherwise, this motor must not be stored outdoors. Slower vertical machines will have the bearings completely covered by the corrosion inhibiting lubricant when it is added to running level. Ball or roller bearing units are shipped from the factory with the bearings properly packed with grease and require no further preparation. Shaft Extensions and Exposed Machined Surfaces, or Flanges Coat these surfaces with a removable rust-preventative, such as Tectyl No. 506. For storing longer than six months, notice should be given to Siemens Factory so that an extra protective coating can be specified for the internal parts of the unit. Otherwise, it is necessary to take the following precautions. Disassemble motor and clean thoroughly. Do not contaminate the lubricant. In open motors, coat all the exposed machined surfaces of the rotor with a non-hardening protective film, such as Tectyl No. 506. This material can be removed with petroleum solvents. Coat the rotor air-gap surfaces lightly. Do not Apply Tectyl Film to the bearings. PREPARATION Sleeve bearing units are shipped WITHOUT lubricating oil in the bearings. A film of rust-inhibiting oil protects the bearings and shaft journals during shipment. This film does not offer sufficient protection for outdoor storage; therefore, before placing in storage, fill the oil wells to operating level with a good grade of rust-inhibiting turbine oil. Repaint all surfaces previously painted, before reassembling. For all periods of storage over one month use silica-gel plugs and half-pound bags. Remove the condensation drain plugs from those units equipped with them, and insert silica-gel plugs into the openings. Insert one-half pound bags of silica-gel, or other desiccant material, into air inlets and outlets of drip proof or splash-proof type motors.

page 7 The bags must remain visible so that they will be noticed and removed when the unit is prepared for service. Cover the unit completely to exclude dirt, dust, moisture and other foreign materials. At a bare minimum, a heavy water-proofed cover should be slipped over the motor, If the unit cannot be moved from its base, and more elaborate protection is desired, all the openings can be covered with an adhesive plastic cloth and the entire unit sprayed with a peelable plastic. Specifications for this material can be secured from the U.S. Government. After the unit is covered as explained in the above paragraph, a shed of some sort should be erected to protect it from direct rain, snow, and excessive direct sun heat. Proper wrapping will protect the unit from sandstorms. If the motor can be moved it is suggested that the entire motor be encased in a strong, transparent plastic bag. Before sealing the bag, a moisture indicator should be attached to the side of the motor, and several bags of silica-gel desiccant distributed inside the bag and around the motor. When the moisture indicator shows that the desiccant has lost its effectiveness, as by a change in color, the bag should be opened and the desiccant replaced by fresh ones. If the motor cannot be sealed, either install space heaters to keep it at least 10 F above the ambient temperature to prevent moisture condensation; or install silica-gel (bags or plugs) in all openings and replace them at least every six months. If motors are not equipped with space heaters at time of manufacture, consult factory for proper size. It must be remembered, that dust and sand will remain hazardous as long as proper cover is not supplied. Rodents and other animals like to house inside motors in search of warm surroundings or food. Some of them attack the insulating materials. Their access to the motor should be restricted. Oil Lubricated, Antifriction Bearings Except for Kingsbury type, vertical machines of 1800 RPM or slower need no oil maintenance after initial care except that once a month the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Vertical machines of 3600 RPM and all Kingsbury oil-lubricated bearings should be run at operating speed every month; if these motors cannot be run, disassemble to reach the bearings and coat them with the rust-inhibiting oil. Otherwise, these motors must not be stored outdoors. Grease-Lubricated, Antifriction Bearings The shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Bearings should be relubricated at two (2) year intervals. Use a polyurea base grease of No. 3 consistency. (Consult instruction book for your unit.) Shaft Extensions Machined Surfaces, or Flanges For very long storage, check the protective life of the rust inhibitor used, and recoat as recommended by the manufacturer. Outdoor life of Tectyl 506 for example, is about two years. Check the condition of the desiccant plugs and bags, preferably weekly. When no desiccant is being used, the correct setting of the space heaters becomes imperative. Make certain they function properly. Space heaters should be sized to keep the motor 10 F above the ambient temperature. Whenever a motor cannot be sealed in a bag and the relative humidity is greater than 50%, long storage calls for space heaters to be installed in the unit, to maintain equipment temperatures at least 10 F above the ambient air, and thus prevent the harmful effects of moisture condensation. If motors are not equipped with space heaters at time of manufacture, consult factory for proper size. INLAND HUMID CLIMATE; (NOT INDUSTRIAL AREA) Conditions Usually Encountered Dust, rain and snow, organic (fungus) growth. MAINTENANCE Once a week the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Motors stored in ambients below 40 F and above 140 F should be stored in an enclosed ventilated structure. Space heaters must be energized. The enclosing structure should be designed to protect the motor from flying debris or other damage from high winds.

page 8 PREPARATION Sleeve bearing units are shipped WITHOUT lubricating oil in the sleeve bearings. A film of rust-inhibiting oil protects the bearings and shaft journals during shipment. This film does not offer sufficient protection for outdoor storage; therefore, before placing in storage, fill the oil wells to operating level with a good grade of rust- inhibiting turbine oil. Oil Lubricated, Antifriction Bearings Vertical machines of 3600 RPM and all Kingsbury oil- lubricated bearings are shipped from the factory WITHOUT lubricating oil in the bearings. A film of rust- inhibiting oil protects the bearing during shipment. This film does not offer sufficient protection for outdoor storage, therefore, before placing in storage, fill the oil wells to running level. Run the machine at operating speed if there are facilities to connect the motor. If the motor cannot be run, facilities must exist to disassemble the motor and the bearings must be coated with rust- inhibiting oil, OTHERWISE THIS MOTOR MUST NOT BE STORED OUTDOORS. Slower vertical machines 1800 RPM and less will have the bearings completely covered by the rust-inhibiting lubricant after oil is added to running level. Ball or roller bearing units are shipped from the factory with the bearings properly packed with grease and require no further preparation. Shaft Extensions and Exposed Machined Surfaces, or Flanges Coat these surfaces with an easily removable rust- preventative, such as Tectyl No. 506. FOR STORAGE OVER ONE MONTH, notice should be given to factory so that an extra protective coating can be specified for the internal parts of the motor. Otherwise, it is necessary to take the following precautions: Disassemble and thoroughly clean units. (For periods over six months storage, repaint all previously painted surfaces, internal as well as external.) Do not contaminate lubricant. In open motors, coat all the exposed machined surfaces of the rotor with a non-hardening protective film, such as Tectyl No. 506. Before reassembly, spray all internal surfaces of the stator (winding and iron) with one coat of an anti-fungus varnish, such as PD. George No. 11137 protective sealer. Reassemble Unit. Remove the condensation drain plugs from those units equipped with them, and insert silica-gel plugs into the openings. Insert one-half pound bags of silica-gel (or other desiccant material) into air inlets and outlets of drip- proof or splash-proof type motors. The bags must remain visible so that they will be noticed and removed when the unit is prepared for service. Cover the unit completely to exclude dirt, dust, moisture, and other foreign materials. At a bare minimum slip a heavy water-proof cover over the motor. If the unit cannot be moved from its base, and more elaborate protection is desired, all the openings can be covered with an adhesive plastic cloth and the entire unit sprayed with a peelable plastic. Specifications for this material can be secured from the U.S. Government. After the unit is covered as explained above, a shed of some sort should be erected to protect it from direct rain, snow, and excessive direct sun heat. Proper wrapping will protect the unit from sandstorms. If the motor can be moved, it is suggested that the entire motor be encased in a strong, transparent plastic bag. Before sealing this bag, a moisture indicator should be attached to the side of the motor and several bags of silicagel desiccant put inside the bag, around the motor. When the moisture indicator shows that the desiccant has lost its effectiveness, as by a change in color, the bag should be opened and the desiccants replaced with fresh ones. Whenever motors cannot be sealed, either space heaters must be installed to keep them at least 100F above the ambient temperature, or a roof and plenty of desiccant material must be provided; otherwise, the unit must be stored indoors. If motors are not equipped with space heaters at time of manufacture, consult factory for proper size. Do not apply Tectyl to the bearings. Rodents and other animals like to house inside motors in search of warm surroundings or food. Some of them attack the insulating materials. Their access to the motor should be restricted.

page 9 MAINTENANCE Once a week the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Oil Lubricated, Antifriction Bearings Vertical machines of 1800 RPM or slower need no oil maintenance after initial care except that once a month the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Vertical machines of 3600 RPM and all Kingsbury oil lubricated bearings should be run at operating speed every month. If motor cannot be run, disassemble unit to reach the bearings and coat them with the rust-inhibiting oil. OTHERWISE, THIS MOTOR MUST NOT BE STORED OUT- DOORS. Grease Lubricated, Antifriction Bearings Once a month the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Bearings should be relubricated at two year intervals. Most Siemens motor bearings use a polyurea base grease of No. 2 consistency; some large horizontal motors and many vertical ones use a No. 3 grease. (Consult your motor instruction book) Shaft Extensions Exposed Machined Surfaces, and Flanges For very long storage check the protective life of the rust inhibitor used and recoat as recommended by the manufacturer. Outdoor life of heavily applied Tectyl 506 for example, is about 2 years. Each week check the condition of the desiccant plugs and bags. Replace them when needed. When no desiccant is being used the correct setting of the space heaters becomes imperative. Make sure they are always functioning properly. Space heaters should be sized to keep the motor 10 F above the ambient temperature. Whenever a motor cannot be sealed and the relative humidity is greater than 5O%, long storage calls for space heaters to be installed in the unit, to maintain equipment temperatures at least 10 F above the ambient air, and thus prevent the harmful effects of moisture condensation. If motors are not equipped with space heaters at time of manufacture, consult factory for proper size. SALTY AND INDUSTRIAL ATMOSPHERES Conditions Usually Encountered Moisture impregnated with salts or other chemicals, salty dust, sand, rain or snow, fungus growth, fumes, coal and chemical dust soot. PREPARATION Motors stored in ambients below 40 F and above 140 F should be stored in an enclosed ventilated structure. Space heaters must be energized. The enclosing structure should be designed to protect the motor from flying debris or other damage from high winds. Sleeve Bearing Sleeve bearing units are shipped WITHOUT lubricating oil in the bearings. A film of rust-inhibiting oil protects the bearings and shaft journals during shipment. This film does not offer sufficient protection for outdoor storage; therefore, before placing in storage, fill the oil wells to operating level with a good grade of rust inhibiting turbine oil. Vertical machines of 3600 RPM and all Kingsbury oil- lubricated bearings are shipped from the factory WITHOUT lubricating oil in the bearings. A film of rust- inhibiting oil protects the bearing during shipment. This film does not offer sufficient protection for outdoor storage; therefore, before placing in storage, fill the oil wells to running level. Run the machine at operating speed for two minutes. If the motor cannot be run, facilities must exist to disassemble the motor and the bearings must be coated with rust-inhibiting oil. OTHERWISE, THIS MOTOR MUST NOT BE STORED OUT DOORS. Slower vertical machines (1800 RPM and less) will have the bearings completely covered by the rust-inhibiting oil after it is added to running level. Ball or roller bearing units are shipped from the factory with the bearings properly packed with grease and require no further preparation. Shaft Extensions; Exposed Machined Surfaces or Flanges Coat these surfaces with a removable rust-preventative, such as Tectyl No 506 FOR STORAGE OVER ONE MONTH, notice should be given to motor plant where manufactured so that an extra protective coating can be specified for the internal parts of the motor. Otherwise, it is necessary to take the following precautions:

page 10 Disassemble and thoroughly clean unit. (For periods of over six months storage, repaint all previously painted surfaces, internal as well as external.) In open motors, coat all the exposed machined surfaces of the rotor with a nonhardening protective film, such as Tectyl No. 506. This material can be removed with petroleum solvents. Coat the rotor air-gap surfaces lightly. Rodents and other animals like to house inside motors in search of warm surroundings or food. Some of them attack the insulating materials. Their access to the motor should be restricted. Do not apply Tectyl film to the bearings. MAINTENANCE Before reassembly, spray all internal surfaces of the stator (winding and iron) with one coat of an anti-fungus varnish, such as PD. George No. 11137 protective sealer. Reassemble Unit. In applying the following procedures, remember that life of rust preventatives decreases under salty and/or alkaline conditions. Remove the condensation drain plugs from those units equipped with them, and insert bags of silica-gel (or other desiccant material) into air inlets and outlets of drip- proof or splash-proof type motors. The bags must remain visible so that they will be noticed and removed when the unit is prepared for service. Cover the unit completely to exclude dirt, dust, moisture and other foreign materials. At a bare minimum, place heavy water-proof cover over the motor. If the unit cannot be moved from its base, and more elaborate protection is desired, all the openings can be covered with an adhesive plastic cloth and the entire unit sprayed with a peelable plastic. Specifications for this material can be secured from the U.S. Government. After the unit is covered as explained above, a shed of some sort should be erected to protect it from direct rain, snow, and excessive direct sun heat. Proper wrapping will protect equipment from sandstorms. If the motor can be moved, it is suggested that the entire motor be encased in a strong, transparent plastic bag. Before sealing the bag, a moisture indicator should be attached to the side of the motor, and several bags of silicagel desiccant put inside the bag, around the motor. When the moisture indicator shows that the desiccant has lost its effectiveness, as by a change in color, the bag should be opened and the desiccants replaced with fresh ones. Whenever the motor cannot be sealed, either space heaters must be installed to keep them at least 100F above the ambient temperature, or a roof and plenty of desiccant material must be provided; otherwise, the units must be stored indoors. If the motors are not equipped with space heaters at time of manufacture, consult factory for proper size. Once a week the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or, if power is available, the motor can be bumped for 5 seconds. Vertical machines of 1800 RPM or slower need no oil maintenance after initial care, except that once a month, the shaft should be rotated by hand at 30 revolutions per minute for 15 seconds or if power is available the motor can be bumped for five (5) seconds. Vertical machines of 3600 RPM having oil-lubricated bearings and all Kingsbury type, should be run at operating speed every month. If motor cannot be run, disassemble the unit to reach the bearings and coat them with rust-inhibiting oil. OTHERWISE, THIS MOTOR MUST NOT BE STORED OUTDOORS. Grease Lubricated, Antifriction Bearings Once a month the shaft should be rotated by hand at 30 revolutions per minute for 1 5 seconds or, if power is available, the motor can be bumped for 5 seconds. Bearings should be relubricated at two year intervals. Most Siemens motor bearings use a polyurea base grease of No. 2 consistency; some large horizontal motors and many vertical ones use a No.3 grease. (Consult your motor instruction book.) Shaft Extensions Exposed Machined Surfaces and Flanges For very long storage check the protective life of the rust inhibitor used and recoat as recommended by the manufacturer. Outdoor life of Tectyl 506 for example, is about two years. Each week check the condition of the desiccant plugs and bags. Replace them when needed.

page 11 PREPARATION FOR SERVICE Cleaning Both the interior and exterior of the motor should be free of spilled oil, water, dust and dirt. The exterior should be wiped and the interior blown out with compressed air at reduced pressure or with a small hand bellows. Wipe off removable rust preventatives with a clean cloth soaked in petroleum solvent. Make sure that the bearings and lubricant cavities are free of dust and dirt, and that the (oil) plugs are tight. Scratches, bruises, or rust on the shaft journals must be carefully removed. 75 C, measured at 500 Volts dc, after one minute should not be less than that given by the following formula: Insulation in Megohms = Rated Voltage of Machine + 1000 1000 If the insulation resistance is less than that recommended, the stator may be dried out by operating at reduced voltage, provided the insulation resistance does not drop below 1000 Ohms per nameplate volts during the drying- out period. Should the value of resistance fall below this figure, the stator should be baked in a forced hot air oven rather than in a radiant type oven. Relubricate Bearings (Refer to instruction book.) Replace Packing (Refer to instruction book.) Remove Desiccant Meggering Regardless of the method of storage, the windings of every motor should be meggered prior to placing in service. Standards of the American Institute of Electrical Engineers recommend the insulation resistance of stator windings at INSULATION DRYING TEMPERATURES* CLASS A CLASS B CLASS F CLASS H 167 F 200 F 245 F 275 F 75 C 94 C 118 C 135 C * Class F & H insulated units should be baked at 70% specified temperature (to avoid steam inside winding) for about 6 hours, before temperature is raised to drying temperature.

MOTOR SERVICE RECORD Serial No. Horsepower Type Speed Volts Amperes Phase Cycles Insulation Class Temperature Rise C Frame Size Connection Diagram - Rotor Stator Owner Order No. Item No. Date Purchased MACHINE TYPE Horizontal Weather-Protected BEARINGS Lubrication SHAFT EXTENSION Vertical Ball Roller Sleeve Length Open Drip-Proof Size: Diameter Totally-Enclosed Front Explosion-Proof Internal Thread Rear External Thread Date Installed Location Application Date Repaired Repaired Total or Replaced Repairs or Parts Replaced (1) Fault by Cost (1) Name of Part No. Per Machine Manufacturer s No. Date Quan. Repl. Cost Date Quan. Repl. Cost Date Quan. Repl. Cost Rotor Stator Coils Bearing, Front... Rear... Other...... Date Checked Bearings Lubrication Excess Heat Excess Noise Speed Voltage Amps Insulation Clean Alignment Vibration Temperature Siemens Energy & Automation, Inc. Industrial Products Division 14000 Dineen Drive Little Rock, Arkansas 72206 INSPECTION 2002 Siemens Energy & Automation, Inc. Bulletin NMIM-L1004 1E 4/02TI Printed in U.S.A.