C554A Cadmium Sulfide Flame Detector

Similar documents
T4398A,B High Performance Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats

The T6140A,B Remote Bulb Temperature Controller

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

T7079A,B Solid State Remote Temperature Controllers

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

CR7075 Two-Stage Lighting Controller

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Commercial/Industrial Combustion Control Level Three Announcement

C6097A,B Pressure Switches

F25F Media Air Cleaner

T6984F,G Electronic Floating Control Thermostats

F150E Media Air Cleaner

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

RA889A Switching Relay

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

C7004B Flame Rod Holder

C7232A,B Sensor and Controller

F200E Charged-Media Air Cleaner

L8151A Triple Aquastat Relay

T7984 A,B,C Electronic Modulating Control Thermostats

H1008A,D Automatic Humidity Controls

T834C Heating-Cooling Thermostat

Instructions For A and Flame Simulators

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

Q382A,B Pilot Burners

T4398A,B Precision Electric Heating Thermostat

T8011R Programmable Heat Pump Thermostat

T6984 A,D,E Electronic Floating Control Thermostats

C7005A,B Gas Pilot and Flame Rod Assemblies

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

M6063A Compact Rotary Mixing Valve Actuator

C7915A Infrared Flame Detector

RA890G Protectorelay Primary Control

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

T874 Multistage Thermostat and Q674 Subbase

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

F59A Console 3-Speed Electronic Air Cleaner

D896 Automatic Vent Damper

HE365A,B Powered Flow-Through Humidifier

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

T8524 Deluxe Electronic Thermostat

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

T8411R Electronic Heat Pump Thermostat

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

IS Series Pressure Sensing Switches

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7823/RM7823 Relay Module

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE

7800 SERIES RM7888A Relay Module

Electronic Thermostat

Home and Building Control Home and Building Control Helping You Control Your World

HE360 Powered Flow-Through Humidifier

T8112 Programmable Thermostat

RA889A Switching Relay

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

UV100E Ultraviolet Air Treatment System

P7810A-D Pressuretrol Controller

T8034C Heating/Cooling Thermostats

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

7800 SERIES 22-Terminal Universal Subbase

AQ255 and AQ257 Series Expansion Zoning Panels

CT500 Electronic Thermostat

HE360A,B Powered Flow-Through Humidifier

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion

T7100D Microelectronic Conventional Thermostat

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

CT1500, CT1501, CT1502, CT1503

Q7800H Integrated Burner Control Subpanel

Deluxe Programmable Thermostats

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

HE420A Steam Power Humidifier

7800 SERIES RM7840E,G,L,M Relay Module

HE360 Humidifier Installation Kit

SIL3. C7961E,F Dynamic Self-Check Ultraviolet Flame Detector. Capable APPLICATION FEATURES PRODUCT DATA. Contents

Honeywell Th8320u1008 Guide

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

CT2700 An Electronic Round Programmable Thermostat

7800 SERIES RM7888A Relay Module

RM7838A 7800 SERIES Relay Modules

HE120, HE160 Humidifier Installation Kit

Transcription:

C554A Cadmium Sulfide Flame Detector FEATURES PRODUCT DATA Cadmium sulfide sensing element provides faster response than bimetal sensors. On flame failure, the cad cell causes the oil primary control to shut down the main burner. Mounting brackets available to fit all applications. Entire cell is hermetically sealed (glass to metal) to reduce cell deterioration by humidity, soot, or oil fumes. APPLICATION The C554A Cadmium Sulfide Flame Detector (cad cell) is a photoconductive flame detector used with oil primary controls such as R4166, R4184, R8182, R8184, R8185, R8404 and R8991. Plug-in cell for easy replacement. Recessed cell provides more accurate flame sighting and prevents accumulation of dirt and soot on cell face. Contents Application... 1 Features... 1 Specifications... 2 Ordering Information... 2 Installation... 3 Operation... 5 Checkout... 5 Service and Replacement... 5 U.S. Registered Trademark Copyright 1996 Honeywell Inc. All Rights Reserved X-XX UL 60-2148-4

SPECIFICATIONS Important The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit might not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Models: C554A Cadmium Sulfide Flame Detector two-wire, two-piece plug-in cell for use with oil primary controls such as R4166, R4184, R8182, R8184, R8185, R8404 and R8991. The TRADELINE Advantage: SUPER TRADELINE and TRADELINE models offer features not available on standard models and are designed to replace a wide range of controls. SUPER TRADELINE and TRADELINE model specifications are the same as standard models except as noted. SUPER TRADELINE Features: 60 in. (1520 mm) leadwires. Interchangeable type A,B,E,J,P brackets. Oil line adapter bracket. SUPER TRADELINE pack and special installation instructions. Electrical: Maximum voltage 60 Vdc or 60 Vac peak. Ambient Temperature: 140 F (60 C) at the cell. Dimensions: See Fig. 1. Mounting (see Fig. 1): SUPER TRADELINE : Interchangeable A,B,E,J,P brackets. TRADELINE : Type E bracket. Standard: Available in all bracket types; specify when ordering. Leadwire: Yellow, single-molded, dual-cord, number 18 stranded wire. NEC Class 1. Varied lengths available on request. Certifications: Underwriters Laboratories Inc. Listed: File Number MP268, Guide Number MCCZ. Canadian Standards Association Component Listed: File Number LR1620, Guide Number 300-1-0.2. Replacement Part: 130367 Replacement Cad Cell. TRADELINE Features: 60 in. (1520 mm) leadwires. Type E mounting bracket. Oil line adapter bracket. TRADELINE pack and special installation instructions. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number, SUPER TRADELINE or TRADELINE if desired. 1. Model number 2. Type of mounting bracket on standard models (Fig. 1). 3. Leadwire length on standard models. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 60-2148 4 2

1/2 (13) 1/4 (6) 1/4 (6) 1 5/16 (33) 5/8 (16) 15/16 (24) 3/16 (5) 1-5/16 (33) 1-5/32 (29) 1 (25) 1/4 (6) 9/16 (14) 1 (25) 11/32 (9) 1 1 TYPE A TYPE B TYPE E 29/32 (23) 1 (25) 5/8 (16) 50 17/32 (13) 5/16 (8) 3/4 (19) 1 1 1 TYPE G TYPE J TYPE K 1-5/8 (41) 1/8 (3) 1-1/4 (32) 17 1-1/16 (27) 11/16 (18) 1 1 1 TYPE P TYPE R TYPE S 1 SOCKET DIMENSIONS AND PLACEMENT OF HOLES ARE THE SAME AS FOR TYPE A EXCEPT WHERE NOTED. M7864 Fig. 1. Mounting bracket dimensions in in. (mm). INSTALLATION When Installing this Product... 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. CAUTION Disconnect power supply before beginning installation to prevent electrical shock or equipment damage. Ambient temperature at the cell location is below 140 F (60 C). Movement, shielding, or radiation of metal surfaces located near the cell do not affect cell operation. IGNITION ELECTRODE NOZZLE CAD CELL AIR TUBE IGNITION TRANSFORMER Location The burner manufacturer determines the cad cell location (see Fig. 2). If an alternate location must be used, make sure that: The cell has a clear view of the flame. Ambient light does not reach the cell. Fig. 2. Cad cell location. M7857 3 60-2148 4

Mounting Direct Replacement for Standard Models Mount the C554A at the rear of the burner. The mounting bracket can be bent to fit, if necessary. Direct Replacement for SUPER TRADELINE and TRADELINE Models Select the mounting bracket that most closely matches the existing mounting bracket (SUPER TRADELINE ) or use the bracket provided (TRADELINE ). Remove the cell from the socket. Insert the mounting bracket into the socket slot (Fig. 3) as far as it will go. NOTE: Bend the mounting bracket to fit, if necessary. While holding the mounting bracket in the slot, insert the screwdriver in the other end of the slot (Fig. 3). Bend the screwdriver, first to the left and then to the right, to crimp the end of the mounting bracket and hold it in position. Remove the screwdriver and replace the cell. Mount the new cell and bracket assembly in the location of the old assembly. Oil Line Mounting for SUPER TRADELINE and TRADELINE Models If desired, mount the C554A on the oil line using the oil line adapter bracket and the mounting bracket that give the C554A the best view of the flame (SUPER TRADELINE ) or use the mounting bracket provided (TRADELINE ). SLOT LEADWIRE SOCKET M7853 Fig. 3. Insert mounting bracket into socket slot. Remove the cell from the socket. Insert the mounting bracket into the slot on the socket (Fig. 4) as far as it will go. NOTE: Bend the mounting bracket to fit, if necessary. SOCKET SCREWDRIVER SOCKET LEADWIRE INSERT SCREWDRIVER AND MOVE IN DIRECTION SHOWN BY ARROWS TO SECURE IN SOCKET SLOT SCREWDRIVER M7855 Fig. 4. Insert screwdriver to secure bracket in socket. 60-2148 4 4

While holding the mounting bracket in the slot, insert the screwdriver in the other end of the slot (Fig. 4). Bend the screwdriver, first to the left and then to the right, to crimp the end of the mounting bracket and hold it in position. OIL LINE MOUNTING SCREW OIL LINE ADAPTER TO NOZZLE OPERATION The C554A Cadmium Sulfide Flame Detector consists of a plug-in, light-sensitive cell and a socket with leadwire. The photocell is a ceramic disk, coated with cadmium sulfide and overlaid with a conductive grid. The entire cell is hermetically sealed (glass to metal) to prevent cell deterioration. Electrodes attached to the ceramic disk transmit an electrical signal to the primary control, which operates the main burner. In darkness, cadmium sulfide has a very high resistance to the passage of electrical current. In visible light, its resistance is very low and current is allowed to pass to the primary control. Flame failure causes the cell to stop conducting electricity, resulting in the primary control shutting off the burner. Fig. 7 shows the sensitivity range of the cad cell. LEADWIRE SOCKET PLUG-IN CELL M7856 RESISTANCE (OHMS) CADMIUM SULFIDE RESISTANCE RANGE Fig. 5. Use oil line adapter bracket to mount C554A on to oil line. Remove the screwdriver and replace the cell. Slide the mounting bracket into the sleeve on the oil line adapter bracket. Push firmly to lock the cell and the bracket assembly in position. Mount the oil line adapter bracket on the oil line using the screw and nut provided (Fig. 5). OIL BURNER RELAY 300,000 200,000 100.000 60,000 30,000 10,000 6,000 THERMOSTAT (24V) T 3,000 C554A CADMIUM SULFIDE FLAME DETECTOR T F F 1,000 600 300 Fig. 6. Typical hookup for C554A to oil burner primary control. M7858 100.02.04.08.02 0.4 0.8 2 4 8.03.06.10 0.3 0.6 1.0 3 6 10 ILLUMINATION (FT CANDLES) M7865 Fig. 7. Light response tolerance for C554A cad cell. Wiring Disconnect power supply before beginning wiring to prevent electrical shock or equipment damage. All wiring must comply with local electrical codes and ordinances. See Fig. 6 for a typical C554A hookup to the oil burner primary control. 5 60-2148 4

CHECKOUT To check cad cell operation, use the following procedure: Disconnect the cad cell leadwires; then start the burner. Shortly after the burner starts, place a temporary jumper between terminals F-F. Connect an ohmmeter across cad cell leadwires; resistance should be less than 1600 ohms. Stop the burner and remove the temporary jumper. With the burner off, check the dark cell resistance across cad cell leadwires. Resistance should be greater than 20,000 ohms. NOTE: If cell resistances are different than specified, recheck the wiring and the location of the cell. If necessary, replace the plug-in part of cell, Honeywell part no. 130367 Replacement Cad Cell. Reconnect cad cell leadwires. Check the Protectorelay Burner Sequencing Relay control according to the instructions packed with the control. SERVICE AND REPLACEMENT In normal operating conditions, the C554A does not require cleaning. If a badly adjusted burner causes heavy accumulation of dirt and soot on the cell surface, carefully wipe the cell surface to restore full view of the oil flame. If the C554A is damaged, replace the plug-in part of the cell. Order Honeywell part no. 130367 Replacement Cad Cell. 60-2148 4 6

7 60-2148 4

Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 2C9 Helping You Control Your World 60-2148 4 J.S. Rev. 2-96 Printed in U.S.A. 8 www.honeywell.com/yourhome