STAT X - SPECIAL HAZARD FIRE PROTECTION

Similar documents
Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

BOC FS125 The Fire Extinguishing Solution

An Overview of Extinguishing Systems for Computer Equipment

FIRE SUPPRESSION SYSTEM

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

Safe, Effective, Environment-friendly

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

PRODUCT CATALOG.

PRODUCT CATALOG.

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Superior by Design The Kidde ADS TM FM-200 System

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

ORDER GUIDE Authorised Reseller

WATER MIST CONVENTION AND EXHIBITION

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

Water Mist Fire Suppression

Creating a safer world!

CO2 COCO GAS FLOODING SYSTEM

The S tat-x F irs t R esponder. A new innovation in fire suppression

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

How can I protect invaluable assets and the environment from the effects of a fire?

Fire Suppression Systems

ODS & SGG Alternatives for the Fire Protection Industry 2018

KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Aerosol Type Fire Extinguisher Aerosol Type Fire Extinguisher

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

7 Fire Protection Systems Synopsis

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

SECTION FM-200 FIRE SUPPRESSION SYSTEM

How can you minimize consequential damages in case of a fire?

Fire suppression systems for server rooms and data centres

Agent Tanks PCL PCL PCL PCL - 600

3M Novec Fire Protection Fluid

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Rick Seidel Fike Corporation Regional Sales Manager

SPECIFICATION: ARGONITE Engineered Fire Suppression System

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

Sprinkler Solutions for Storage Applications

TOP AND CONSOLE PARTS

Portable Fire Extinguishers

EXTINGUISHING SYSTEM DETECTION AND CONTROL

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

CHAPTER THREE SPRINKLER SYSTEM AND FM-200 AGENT SYSTEM

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

DSPA-5 Manual. Product Information, Usage, Preperation and Deployment guidelines for users of the DSPA -5

SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Hospitals and Major Medical Centers

Fire Prevention Plan

SUPPRESSION SALES I INSTALLATION I SERVICE

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

Inert Gas Fire Extinguishing System

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Sprinkler System Installer Level 2

GX-20/FM-200 Fire Extinguishing System

C L E AN A G ENT FIRE SUPPR E SSIO N S Y S T E M S

CLEAN AGENTS Updates to the NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems 2015 Edition

Fire Protection in the Mining Industry. Garry Kwok Board Member

CONTENTS. bawa-speci, Ver Maintenance. 1. INTRODUCTION: 1.1 bawa-speci Version 01

OPERATING MANUAL AGS-15 FOR THE FIRE EXTINGUISHING AEROSOL GENERATORS OF OPERATIONAL USE ПЕРЕНОСНОЙ. JSC «NPG Granit-Salamandra»

Fire Prevention Plan

Refrigeration dryers DW 2-504

Badger Universal Control Head

CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection

The Sensible Solution to a global dilemma

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

SAFETY THE BEST FOR YOUR EQUIPMENT

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

THE EXCLUSIVE MAINTENANCE RESOURCE FOR THE TRANSIT AND MOTORCOACH INDUSTRY

Safety Manual Section 7 Fire/Life Safety

Fire Prevention Plan Program

FirePro INSTALLATION AND USE MANUAL VERSION 1.0, REV. 2 MANUAL NO. EX 6960 JUNE 2011 CONDENSED AEROSOL FIRE EXTINGUISHING SYSTEMS

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Fire protection for buildings

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

THE WORLD LEADER. in special hazard fire suppression solutions

FM-200 In-Cabinet Series

Protecting Critical Facilities Against Explosions

Transcription:

FIRE & SECURITY TECHNOLOGIES STAT X - SPECIAL HAZARD FIRE PROTECTION FIRE & SECURITY TECHNOLOGY Singapore +65 6757 7045 Indonesia +62 21 8778 2069 www.fast.expert / sales@fast.expert 1

Low Cost of Ownership NFPA standards and manufacturer guidelines all require regular system maintenance. This is essential to help ensure your suppression system is ready to respond in a fire emergency. But maintenace costs can be signficant over the life of a system and must be considered early on. Because Stat X fire suppression has no distribution pricing or presurized agent vessels, maintenace activity is minimal. this dramatically decreases the cost of ownership compared to other systems. Traditional Special Hazard Fire Protection Centers Around Two Technologies Water deluge and chemical agent fxed systems protect high value assets and processes not possible with sprinkler-based fre protection. But this technology remains basically unchanged over the years; a supply of agent is stored under pressure, released through a piping distribution network, foods the space, an suppresses the fire. Traditional piped systems require costly installation adaptations like: * Extra space for agent containers and piping * Robust fxtures to handle weight and discharge * System isn t easily reconfgured if space changes * Extensive and frequent maintenance burden * Special measures for recharging at remote sites Fire Professionals Are Switching to Stat-X! The number of required maintenance tasks, their complexity and frequency determine costs over time. Tasks shown above are taken from UL-listed design, installation, operation and maintenance manuals from various manufacturers. By comparison, Stat-X system inspection and maintenance has fewer tasks, saving both time and labor. Fire safety professionals who do cost-to-beneft risk analysis quickly realize Stat-X fre suppression is the most economical system, offering the most effective fre protection, for many special hazard applications The inherent fexibility of design combined with equipment and labor savings allows them to enhance coverage for currently protected assets and add coverage to previously neglected areas. What Our Customers Are Saying Stat-X protecting one of our CNC machines discharged due to fire, suppressing it. The area was unmanned and the automatic system stopped the fire from spreading. We were up and running again fast! - Manufacturer, Geneva, IL Traditional Special Hazard Fire Protection An Effective and Economical Alternative For safety professionals who need effective and economical special hazard fre protection, Stat-X aerosol technology delivers up to 35% savings in equipment and lifecycle costs compared to traditional systems. This is due to lower initial expense plus minimal ongoing service costs. Stat-X aerosol technology is different: * NO distribution piping, manifold, or nozzles * NO foor space requirement or shoring up for weight * NO special handling for compressed gas cylinders * NO venting or ceiling tile clips for discharge forces * NO solenoid actuators, control heads, or hoses * NO water drains or pipe freeze protection * NO system pressurization or room integrity tests It works wonders. One Stat-X First Responder knocked down the fire. They are life savers. - Firefighter, Deer Park, NY After researching available special hazard systems for the very best protection as well as compliance with safety and environmental issues we found Stat-X technology as the product leader. Engineer, Leicestershire, UK 2 3

FIRE & SECURITY TECHNOLOGY How it Works FIRE & SECURITY TECHNOLOGY Wide Range of Solutions Stat-X devices are termed condensed aerosol agent generators because they generate an ultra-fne suspension of highly ionized potassium fire-fghting particles upon actuation By Size and Activation Type Electrical Series The key elements in the generation process are: * Device is sealed and stable until actuated * Actuator at top energizes proprietary compound, creating aerosol agent by exothermic oxidation * Build-up of ultra-fne particles and nitrogen gas breaks membrane seal and exits through ports * Discharge fills protected area with a soft suspension of Stat-X agent without super-pressurizing space * Potassium ions combine with fragments of combustion, inhibiting the fire chain reaction * Agent particles also absorb heat from the fire and form inert gases upon decomposition * Minute Stat-X agent particles (<2 Um) remain in suspension afterwards, helping check re-ignition * Post-fire area is easily vented and cleaned, with no harmful byproducts generated Thermal Series The superior effectiveness of condensed aerosols is due to a unique set of characteristics unmatched by other special hazard agents This is why it is by far the most effcient fire suppression agent by weight. * Most efficient fire suppression by weight * Effective on A, B & C Class fires * Negligible residue, minimal clean-up Manual Series * Non-toxic, EPA listed halon substitute Key Approvals Worldwide Aerosol fire suppression technology is well-known throughout Europe and Asia In the past few years, more fire protection engineers in the Americas are recognizing its worth for protecting special hazards. Stat-X First Responder Norms such as NFPA 2010: Standard for Fixed Aerosol Fire Extinguishing Systems and UL 2775: Fixed Aerosol Extinguishing Systems Units now govern its use in a wide variety of applications. Stat-X technology is also listed by the USA Environmental Protection Agency as a Halon alternative under its Signifcant New Alternatives Policy (SNAP) program It has no Ozone Depletion Potential (ODP) and zero effective Global Warming Potential (GWP) meaning Stat-X agent is not prone to future bans like many halocarbon agents. Compatible With Popular Control Panels Stat-X aerosol generators use the same actuation methods as other special hazard fire systems: * Simple manual release, * Automatic thermal release, or * Sophisticated electronic detection and control 4 Compatabilty with many manufactuers UL listed agent release panels means Stat-X fire suppression can integrate into networks for central reporting or to mass notification systems per NFPA 72 National Fire Alarm and Signaling Code. 5

Thermal/Manual Operation Stat-X Aerosol Generators Manual/Thermal Actuation Heads Part #15300 30 T Stat-X Generator Part #15311 60 T Long Stat-X generator Part #15410 100 T Stat-X Generator Part #15510 250 T Stat-X generator Part #15511 250 MT Stat-X Generator Part #15610 500 T Stat-X generator Part #15711 1000 MT Stat-X Generator 6 7

Manual Only Actuation Heads Thermal Operation Stat-X Aerosol Generator Mounting Brackets Thermal Switches Part #18001 Mounting Bracket Part #18005 Mounting Bracket SS Fits 30 T/E & 60 T/E Stat-X generators Part #18010 Mounting Bracket Fits 100 E/T & 250 ME/MT Stat-X generators The thermal switches we offer are meant to be used with thermal operation Stat-X aerosol E- model aerosol generators to provide a dry contact interface point for shutting down process equipment and/or HVAC equipment in a protected area or to monitor a Stat-X aerosol generator for notification that it has discharged. The thermal switches are one time use devices that should be attached to the discharge port end of a Stat-X generator, when the generator discharges the heat of the aerosol agent and the generator will activate the switch. Fits 250 T/E, 500 T/E, 1000 ME/MT Stat-X generatorss Part #18006 Heavy duty bracket for 100 T/E and 250 MT/ME Stat-X generators Part #18011: Heavy duty bracket for 250 T/E, 500 T/E, and 1000 MT/ME Stat-X generators 8 9

Stat-X Cable Pull Rope Assemblies Cable pull polycarbonate cover box include clear cover. Intended for bulkhead surface mount and includes vertical and horizontal hinges for snap-on cover. Cover is lockable or fitted with breakable tamper seal (not supplied). T-handle cables have removable knobs and bulkhead fittings for penetration mounting. Stainless oval sleeve crimp 300 F rated bowden cable pull rope with red T-handle & extender cable rope Recessed stainless steel open cup (Part #14698) can be used with black T-handle cable pull for use with consoles 200 F rated bowden cable pull rope with black T-handle Cable tee pulley (Part #14663) will accept a T-handle cable pull rope as input and two extender cables as outputs. This permits one T-handle to pull the cotter pins of 2 thermal/manual head activators. Tiered use of multiple tee pulleys is possible. Cable tee pulley (Part #14663) will accept a T-handle cable pull rope as input and two extender cables as outputs. This permits one T-handle to pull the cotter pins of 2 thermal/manual head activators. Tiered use of multiple tee pulleys is possible. 10 11

Stat-X Fire Suppression System Signs Electrical Operation Stat-X Aerosol Generators Part #16050 Exit Sign Part #16051 Entry Warning Sign Part #15100 30 E Stat-X generator Part #15110 60 E Stat-X generator Part #15111 60 E Long Stat-X generator Part #16052 Isolate Switch Sign Part #16053 Manual Pull Station Sign Part #15120 100 E Stat-X generator Part #15130 250 E Stat-X generator Part #15530 250 ME E Stat-X generator Part #15140 500 E Stat-X generator Part #15150 1000 E Stat-X generator Part #15550 1000 ME Stat-X generator Part #16054 Manual Cable Pull Station Sign Part #15160 1500 E Stat-X generator Part #15170 2500 E Stat-X generator 12 13

Electrical Operation Stat-X Aerosol Generator Mounting Brackets Penetrator Bracket Assembly Part #18275 - Penetrator bracket assembly for 1000 E, 1500 E, and 2500 E Stat-X generators only This bracket is used to mount Stat-X generators in a sidewall of the protected space so that they are outside the area. Part #18001 Mounting Bracket Part #18005 Mounting Bracket SS Part #18010 Mounting Bracket Fits 30 T/E & 60 T/E Stat-X generators Part #18015 Mounting Bracket SS Fits 100 T/E & 250 ME/ Fits 250 T/E, 500 T/E, MT Stat-X generators and 1000 ME/MT Stat-X Part #18006 Heavy duty bracket for 100 T/E and 250 MT/ME Stat-X generators Fits 1000 E, 1500 E, 2500 E Stat-X generators Part #18011- Heavy duty bracket for 250 T/E, 500 T/E, and 1000 MT/ME Stat-X generators Part #18016- Heavy duty bracket for 1000 E, 1500 E, and 2500 E Stat-X generators 14 15

Cable Adapter Stat-X First Responder The cable adapter (Part #14640) can be used for connecting releasing circuit wiring from a junction box to the 3/4 threaded coupling on electric operation Stat-X aerosol generators. It has a cable gland that will tighten around releasing circuit wiring. Stat-X Aerosol Generator Protective Disks The protective disks we offer are optional devices that can be installed on the discharge port end of Stat-X aerosol generators to provide additional protection when they are going to be installed in harsh environments. 16 17

FIRE & SECURITY TECHNOLOGIES FIRE & SECURITY TECHNOLOGY Singapore AMK Tech 1, BLK 3 #05-04, Ang Mo Kio Industrial Park 2A Singapore, 568050 PH: + 65 6757 7045 Email: sales@fast.expert Indonesia Gd. Nariba Dua Floor.2 No.206 Jl.TB.Simatupang No.49 Jakarta Timur 13760 PH: +62 21 8778 2069 Email: sales@fast.expert Singapore +65 6757 7045 Indonesia +62 21 8778 2069 www.fast.expert / sales@fast.expert 18