PQS performance specification

Similar documents
PQS performance specification

PQS performance specification

PQS performance specification

PQS Independent type-testing protocol

TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference:

PQS performance specification

PQS performance specification

PQS Independent type-testing protocol

PQS performance specification

PQS performance specification

PQS performance specification

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room:

No previous protocol.

PQS Independent type-testing protocol

` PQS Independent type-testing protocol

PQS Independent type-testing protocol

PQS Independent type-testing protocol

Record of Amendments. Version Date Amendment Section/page affected

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

PQS Independent type-testing protocol

E01: Cold rooms and freezer rooms

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

2. Safety instructions

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Installation Manual Premier Elite IXP-W

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Premier External TD. Installation Manual INS352-3

Achieve Success with European Medical Device Commercialization. By Russ King

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

Installation Manual. Premier IXP-W INS538

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Shipboard incinerators with capacities up to 4000 kw

WÄRTS1LÄ. EC-Declaration of Conformitv. In accordance with the Marine Equipment Directive 2014/90/EU

AUGUST 2016 CONTENTS:

INTERNATIONAL STANDARD

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

safety requirements are to comply with this compulsory specification twelve (12) months after the publication of this notice.

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

IECRE OPERATIONAL DOCUMENT

INTERNATIONAL STANDARD

CE marking & your legal obligations

Chain saws (electric mains powered and battery powered)

Owner & Operator s Manual. Table of Contents

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 054/02)

Test Report. Appliance EMF Testing

INTERNATIONAL STANDARD

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5

INTERNATIONAL STANDARD

On Electromagnetic Compatibility

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

TECHNICAL SPECIFICATION

Lawnmowers (pedestrian controlled, battery powered)

YOUR GUIDE TO UNDERSTANDING CPR

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

EMC Regulatory Requirements: What you need to know for the EU, EAEU & Australia. Dr Alex Martin

CE marking & your legal obligations

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

CONFORMITY ASSESSMENT GUIDELINES. Version 1.0

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 209/02)

INTERNATIONAL STANDARD

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Garden blowers, vacuums and blower/vacuums (electric mains powered)

CE Marking and Technical Standardisation

BLUE ANGEL The German Ecolabel Stationary air conditioners DE-UZ 204 Basic Award Criteria Edition August 2016 Version 1

Robotic Mowers (battery powered and charging station connected to electric mains or low voltage supply)

INTERNATIONAL STANDARD

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

Lawnmowers (pedestrian controlled electric mains-powered)

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

Gas meters - Conversion devices - Part 1: Volume conversion

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

IMAS nd Edition Director, United Nations Mine Action Service (UNMAS), DC2 0650, United Nations, New York, NY 10017, USA

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Official Journal of the European Union

EL765. Fire Extinguishers [EL /2/ ]

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Medical electrical equipment

INTERNATIONAL STANDARD

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

Government of India Ministry of Environment and Forests

Infrared Thermometer

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS OF APPROVAL AND RECIPROCAL RECOGNITION OF APPROVAL FOR MOTOR VEHICLE EQUIPMENT AND PARTS

ISO/TS TECHNICAL SPECIFICATION

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

INTERNATIONAL STANDARD

IQ/OQ Protocol Installation Qualification/ Operation Qualification

AMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION

IECEE OPERATIONAL DOCUMENT

Guidance Note No 19/1. CE Marking windows and doorsets


GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

Transcription:

PQS performance specification WHO/PQS/E06/TR04.1 Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Specification reference: E06/TR04.1 Product verification protocol: E06/TR04.VP.1 Date of origin: 30 November 2006 Date of last revision: Replaces PIS specification E6/TR1 rev. 01.01.1998 Contents: 1. Scope:... 2 2. Normative references:... 2 3. Terms and definitions:... 2 4. Requirements:... 2 4.1 General:... 2 4.2 Performance:... 3 4.2.1 Operating temperature range:... 3 4.2.2 Accuracy:... 3 4.2.3 Resolution:... 3 4.2.4 Temperature sensors:... 3 4.2.5 Alarm contacts and door-open sensor:... 3 4.2.6 Unit of measurement:... 3 4.2.7 Calibration:... 3 4.2.8 Casing:... 3 4.2.9 IP rating:... 3 4.2.10 Chart type:... 3 4.2.11 Pen type:... 3 4.2.12 Longevity of temperature trace:... 3 4.2.13 Recording period:... 3 4.2.14 Power source:... 3 4.2.15 Power lead:... 3 4.2.16 Digital display:... 3 4.2.17 Electromagnetic compatibility:... 3 4.3 Environmental requirements:... 4 4.3.1 Ambient temperature range during transport and storage:... 4 4.3.2 Ambient humidity range during transport, storage and use:... 4 4.3.3 Resistance to electrical storms:... 4 4.4 Physical characteristics:... 4 4.4.1 Overall dimensions:... 4 4.4.2 Weight:... 4 4.5 Interface requirements:... 4 4.6 Human factors:... 4 4.7 Materials:... 4 4.7.1 Ozone depleting chemicals:... 4 4.7.2 Other restricted materials:... 4 4.8 Warranty:... 4 4.9 Servicing provision:... 5 4.10 Disposal and recycling:... 5 4.11 Instructions:... 5 WHO/PQS/E06/TR04.1 1 of 7 30 November 2006

4.12 Training:... 5 4.13 Spare parts:... 5 4.14 Verification:... 5 5. Packaging:... 5 6. On-site installation:... 5 7. Product dossier:... 5 8. On-site maintenance:... 6 9. Change notification:... 6 10. Defect reporting:... 6 1. Scope: This specification describes the performance requirements for wall-mounted pen recording thermometers to be used to record the storage temperature in primary and intermediate cold rooms and freezer rooms containing vaccine stocks in situations where electronic logger systems are inappropriate 1. 2. Normative references: EMAS: European Union Eco-Management and Audit Scheme. European Union Directive 2002/96/EC: Waste Electrical and Electronic Equipment. IEC 60529: Consolidated Edition 2.1 (incl. am1): Degrees of protection provided by enclosures (IP Code). ISO 9001: 2000: Quality Management Systems Requirements. ISO 14001: 2004: Environmental management systems - Requirements with guidance for use. ISO/IEC 17025: 2005: General requirements for the competence of testing and calibration laboratories. 3. Terms and definitions: In writing: means communication by letter, fax or email. Legal Manufacturer: The natural or legal person with responsibility for the design, manufacture, packaging and labeling of a product or device before it is placed on the market under his own name, regardless of whether these operations are carried out by that person himself or on his behalf by a third party. Montreal Protocol: Montreal Protocol on Substances that Deplete the Ozone Layer. NIST: United States National Institute of Standards and Technology. Reseller: A commercial entity, licensed to act on behalf of a Legal Manufacturer, and which carries product liability and warranty responsibilities no less onerous than those carried by the Legal Manufacturer. 4. Requirements: 4.1 General: Wall-mounted pen recording thermometers to be used to record the storage temperature in primary and intermediate cold rooms and freezer rooms 1 Inappropriate locations for electronic systems includes store sites where technical support is weak and/or the electricity supply is unreliable. WHO/PQS/E06/TR04.1 2 of 7 30 November 2006

containing vaccine stocks in situations where electronic logger systems are inappropriate. 4.2 Performance: 4.2.1 Operating temperature range: Upper limit: +50 C. Lower limit: -30 C with under-range protection as clause 4.3.1. 4.2.2 Accuracy: ±1.0 C or better within the range -30 C to +20 C 4.2.3 Resolution: ±0.5 C or better within the range -30 C to +20 C 4.2.4 Temperature sensors: Temperature sensor(s): One or two remote electronic, or gas/vapour pressure temperature sensors to be located in the refrigerated chamber. Lead length: up to 15 metres. 4.2.5 Alarm contacts and door-open sensor: Alarm contacts: Adjustable, break on rise and fall, with 2 contacts. It must be possible to set contacts to trigger below +2 C and above +8 C for cold rooms and above -15 C for freezer rooms. A minimum contact for freezers and freezer rooms is not essential. Door open sensor: A door open sensor will be required in some applications. 4.2.6 Unit of measurement: Temperatures must be displayed in degrees Centigrade only. 4.2.7 Calibration: Each instrument is to be supplied with a calibration certificate issued by an ISO/IEC 17025 accredited testing laboratory or by NIST. The certificate must be accompanied by a copy of the reference instrument calibration certificate. 4.2.8 Casing: Non-corrodible plastics or metal case. 4.2.9 IP rating: Protection of the product not less than IEC 60529: IP54. 4.2.10 Chart type: Replaceable paper disc or replaceable fanfold paper strip. 4.2.11 Pen type: Refillable or inkless pen. Fibre pens are not acceptable. Thermal trace models are acceptable provided the requirements of clause 4.2.12 are satisfied. 4.2.12 Longevity of temperature trace: The chart and pen combination is to be capable of retaining a legible trace for a period of not less than three years when the used chart is stored in the dark at ambient temperatures up to 43 C. 4.2.13 Recording period: The minimum acceptable recording period between chart changes is to be seven days. 4.2.14 Power source: 110/240 volt 50/60 Hz mains operated with rechargeable battery backup with a minimum 48 hr charge capacity. The battery is to be replaceable. 4.2.15 Power lead: The device is to be supplied with a power lead for wiring directly into an electrical outlet. Plugs are unacceptable as they can be removed by the user. 4.2.16 Digital display: Products may include a digital temperature displaying the current temperature at the sensor head(s). The display must be in degrees Centigrade. 4.2.17 Electromagnetic compatibility: Operation of the device must be unaffected in the normal electromagnetic compatibility environment in which it is intended to work, taking into account disturbance generated by adjacent apparatus which is compliant with relevant ISO, EN, or other internationally recognized WHO/PQS/E06/TR04.1 3 of 7 30 November 2006

standards. Information required to ensure uninterrupted use of the device must be contained in the user instructions. 4.3 Environmental requirements: 4.3.1 Ambient temperature range during transport and storage: -30 C to +55 C with device inactivated. 4.3.2 Ambient humidity range during transport, storage and use: 0 to 95% RH. 4.3.3 Resistance to electrical storms: The functionality of the device must not be affected by intense electrical storm activity. 4.4 Physical characteristics: 4.4.1 Overall dimensions: Not critical provided chart trace is fully legible. 4.4.2 Weight: Not critical. 4.5 Interface requirements: Alarm contacts as clause 4.2.4 to interface to a battery or mains operated alarm sounder as specified in PQS specification E06/AL.01. 4.6 Human factors: 4.6.1 Temperature charts: Temperature charts are to be pre-printed with a high legibility circular centigrade scale capable of being read by a person with normal vision (with or without glasses) both in bright sunlight and in tungsten/fluorescent lighting at 100 lux on the working plane: Below zero temperature range indicated with a minus sign. Above zero temperature range indicated with a plus sign. Safe zones for ranges of +2 C to +8 C and -15 C to -25 C (depending upon application) to be printed on the chart in the form of clearly identified lines or applied tone. Numeral size: 2 mm high minimum. Reading angle: between 80 and 100 to the plane of the support plate. Colour of markings: dark blue or black on a white background. 4.6.2 Digital display: Digital readout, where included, must be capable of being read by a person with normal vision (with or without glasses) both in bright sunlight and in tungsten/fluorescent lighting at 100 lux on the working plane. 4.6.3 Mounting device: The product is to be mounted on a vertical surface. Fixings suitable for attachment to a sectional cold room/freezer room or to a masonry wall are to be supplied. 4.7 Materials: 4.7.1 Ozone depleting chemicals: During manufacture and assembly of the printed circuit boards and final assembly of the product do not use any substance included in Annex A, B or C of the Montreal Protocol. 4.7.2 Other restricted materials: The product and its constituent components, including batteries, must not contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated biphenyl ethers (PBDE). 4.8 Warranty: The product is to be covered by a three year replacement warranty in the event of any component failure. WHO/PQS/E06/TR04.1 4 of 7 30 November 2006

4.9 Servicing provision: The product is to be maintenance-free apart from routine re-calibration and the replacement of charts, pens and rechargeable batteries. 4.10 Disposal and recycling: The manufacturer is to provide information to the buyer on the hazardous materials contained within the system and suggestions for resource recovery/recycling and/or environmentally safe disposal. For the European Union WEEE compliance in accordance with European Union Directive 2002/96/EC is mandatory. 4.11 Instructions: Detailed fixing, commissioning and end user instructions are to be supplied with every instrument, in Arabic, English, French, Mandarin Chinese, Russian and Spanish. 4.12 Training: No requirement. 4.13 Spare parts: Blank charts and ink refills (where relevant) are to be supplied with every instrument, sufficient for 5 years normal operation. 4.14 Verification: In accordance with PQS Verification Protocol E06/TH03.VP.1 5. Packaging: Materials used for packaging the finished product are to be free of ozonedepleting compounds as defined in the Montreal Protocol. 6. On-site installation: Not applicable. 7. Product dossier: The legal manufacturer or reseller is to provide WHO with a pre-qualification dossier containing the following: Dossier examination fee in US dollars. General information about the legal manufacturer, including name and address. Unique identification reference for the product type. Full specifications of the product being offered, covering all the requirements set out in this document, including details of product marking and traceability. Certified photocopy of calibration certificate issued by an ISO/IEC 17025 accredited testing laboratory or by NIST. Certified photocopies of all type-approvals obtained for the product, including CE marking and the like. Certified photocopies of the legal manufacturer s ISO 9001 2000 quality system certification. Where relevant, certified photocopies of the legal manufacturer s ISO 14001 certification, EMAS registration or registration with an equivalent environmental audit scheme. Conformity with an environmental audit scheme is not mandatory; however preference will be given to manufacturers who are able to demonstrate compliance with good environmental practice. WHO/PQS/E06/TR04.1 5 of 7 30 November 2006

Where available, laboratory test report(s) proving conformity with the product specifications. One sample of the product complete with sensor lead(s), paper chart and pen(s). [The sample will be returned following evaluation provided the manufacturer pays the return carriage charge.] Indicative cost of the product per unit, per 10 units and per 100 units EXW (Incoterms 2000). 8. On-site maintenance: Not applicable. 9. Change notification: The legal manufacturer or reseller is to advise WHO in writing of any changes which adversely affect the performance of the product after PQS prequalification has taken place. 10. Defect reporting: The legal manufacturer or reseller is to advise WHO and the UN purchasing agencies in writing in the event of safety-related product recalls, component defects and other similar events. WHO/PQS/E06/TR04.1 6 of 7 30 November 2006

Revision history: Date Change summary Reason for change Approved 14 Mar 06 Specification redrafted. Normative references, definitions and additional clauses added. To achieve conformity with PQS documentation standards UK 21 Sep 06 Footnote 1 amended. 4.2.15: changed to fixed wiring. 4.2.17: clause added. 4.3.1: Lower limit changed to -30 C, upper limit changed to +55 C, storage and with device inactivated added. 4.3.2: storage added. New clause 4.7.2. 4.7.3 and 4.7.4 deleted. 5: CFC changed to ozone-depleting. Corrections. Consistency with other specifications during final review. EU RoHS Directive material restrictions incorporated. UK (30 November 2006 - PQS secretariat) WHO/PQS/E06/TR04.1 7 of 7 30 November 2006