VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

Similar documents
Power Generation. ASD 535 Application Report

Intelligent Earliest Warning Aspirating Fire Detector

GE Security. air sampling pipe networks installation and design manual

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

FireNET Vapor. Pipe Network Design Guide. June 2013 Document: 25845_00 Part Number: HA

Data Centers. ASD 535 Application Report

CAPILLARY SAMPLING INTRODUCTION. Page 1 CAPILLARY SAMPLING

HART XL High Sensitivity Smoke Detection

Why Hart XL Aspirating Smoke Detection?

Aspirated Smoke Detectors

VESDA. White paper. Using air sampling smoke detection to protect mission-critical facilities from fire. Overview

Buys Time. Aspirating Smoke Detection

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

LaserFOCUS VLF-250 Engineering Specification

METHODOLOGY FOR SMOKE DETECTION IN GRAIN AND HATCHERY APPLICATIONS Dave Boyack

Buys Time. Aspirating Smoke Detection

Aspirating Smoke Detection for Duct Monitoring

The World's No. 1 Brand of Air-sampling Smoke Detector

INTRODUCTION TO SOLAR THERMAL POWER STATIONS We shall look at some of the different methods of supplying solar energy to the power stations.

4 August Islington Fire Protection Transpower NZ Limited

HART XL High Sensitivity Smoke Detection

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

Explosion Protection Engineering Principles

Refrigerated Storage Design Guide

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Aspirating Smoke Detection (ASD) Systems Fire Detection

Better Air Dispersion for. Underfloor. Plenums

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Aspirating Systems Design and Application Guide

Flexible Air-sampling Smoke Detection

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

GreenPark. GreenJet Throw Performance

Fire protection for emergency power supply

AUTOMATIC FIRE SUPPRESSION SYSTEMS

The World's No. 1 Brand of Aspirating Smoke Detector

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

FIRE PROTECTION REGULATION AND EXPERIENCE FIRE PROTECTION IN INDONESIA. Agus Waluyo Indonesian Nuclear Energy Regulatory Agency

Cerberus FIT conventional system

Aspirating Smoke Detection for Large Area Coverage Applications

Early Warning Fire Detection Engineering

2015 Building Condition Survey Summary Mosaic Associates Architects 02/19/16

Aspir A ation spir P R O D U C T S

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

NEW Restek Electronic Leak Detector

The World s No. 1 Brand of Aspirating Smoke Detection

2012 International Mechanical Code Significant Changes. About the Significant Changes

DOCUMENT TABLE OF CONTENTS

FIREFLY PELLET SOLUTIONS PDF- VERSION ADJUSTED FROM THE BROCHURE HOW TO PROTECT BIOENERGY PROCESSES AGAINST FIRE AND DUST EXPLOSIONS

Brivis Touch Controller. Installer Manual

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Building Emergency Response Scenario

LM80031 Issue H. Installer s Handbook

Company Directive STANDARD TECHNIQUE : SP1N

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

Development of Performance Equivalency Methodology for Detection and Suppression System Integration

WHITE PAPER.

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

Airflex Radial & ISO Thermal pipe

DCSS (ACB) Data Center Fire Suppression Procedures

tççç= ÜÉ~íáåÖ çéíáçåë

Soot Mitigation Strategies

Vision Air Conditioning Range Condenser-less Air Conditioner

Technical Information

Environmental Health and Safety Biological Safety Program Guidance Document

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

A Comparison of Aspirated Smoke Detectors

VESDA VLQ. Product Guide VLQ-100. October 2014 Document: 26104_06 Part Number: 30320

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Todd Jekel, Assistant Director, IRC Feb. 8, Standard Definition. What is a machinery room?

Computing Services Center

Your computer system is the lifeblood of your business. Cyber threats are. what you hear most about today. Hacks, viruses and spyware get constant

Series Internal Detector

Monitoring of Electrical Equipment Failure Indicators and Alarming

POWER UP WITH TP ELECTRIC, INC.

Aspirating smoke detection

Exhaust Duct Design Page 1 of (C)

Aspirating Smoke Detection

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Type UB-2502A and UB-3002A Forced-Air Heater

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

2015 MECHANICAL CODE REQUIREMENTS

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

High-precision aspirating smoke detectors for every requirement.

Installation, Operation and

TRANSMISSION AND DISTRIBUTION SUBSTATIONS

Rapid Response Series (RR e & RR i) OPERATING MANUAL

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Arc Fault Protection System D1000

STEPHEN W. COLLINGS, MSEE, PE, Post Office Box CFEI, CVFI, CESCP Franklin, TN Telephone: (615)

Smoke detection in hazardous areas:

APC APPLICATION NOTE #109

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

DISTRIBUTION OPERATIONS AND MAINTENANCE

InvisiFence User Manual

Transcription:

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

Industry Guide - Substations The transmission and distribution of electricity is integral to the entire power generation and supply cycle. The role of the Substation is two-fold: Acts as a switching interface to convert the generated power to the voltage required for transmission. Transforms the transmission voltage to the correct distribution voltage for industrial, commercial and domestic use.

Industry Guide - Substations The risk of fire in a substation can be reduced by installing early warning smoke detection. The threat of transmission/distribution downtime, power outage within the system and loss of revenue is also prevented. The consequential impact of fire at a substation site necessitates the installation of early warning smoke detection.

Design Considerations The following design aspects should be considered when specifying an aspirating (air sampling) smoke detection system: Local Fire Codes & Standards; Power Generation & Transmission Industry Codes of Practice; Fire risks in key operational areas; Airflow characteristics & stratification levels; Manning levels & remote sites.

Operational Areas - Substations Substations contain key areas with specific equipment, operating processes and environmental characteristics that exhibit varied levels of fire risk. The design of a smoke detection system should address the level of identified risk and also comply with local fire codes and standards. VESDA s early warning smoke detection technology provides optimum protection from the threat of fire.

Operational Areas - Substations Operational areas of a substation in which VESDA can be used. Areas Essential Recommended Switch Rooms - Room Sampling - In-Cabinet Sampling Control Rooms - Room Sampling - In-Cabinet Sampling - Under Floor Sampling Cabinets - In-Cabinet Sampling Cable Trenches - Area/Space Sampling Battery Rooms - Room Sampling

Operational Areas - Substations Control Room Battery Room Cables to High Voltage Switching Towers Cabinets Switch/Relay Room Underground Cable Trenches

Performance-based design (PBD) Smoke testing determines: a) The optimal location for sampling pipework. b) Airflow levels, fire loading, ventilation, ignition sources and physical/environmental conditions that determine the level of fire risk. VESDA complements the PBD approach by providing a proactive and early warning sequence of responses.

Challenges to Smoke Detection Substations contain unique operational areas that can impede the detection capability of conventional smoke detection systems. Example: The underground location, limited access and confined space of Cable Trenches can affect the identification of smoke by a conventional smoke detector.

Key Fire Risks High voltage cable networks, high and low voltage switchgear and control equipment. Overheating electrical control equipment (usually cabinet-enclosed). Large banks of high capacity batteries for the uninterrupted power supply (UPS). Arcing and static electrical charge.

Pipe Design for Smoke Detection Standard Room Sampling: Sample pipework is installed in a grid format as per local code specification (sampling holes typically correspond with the location of a point detector).

Purpose: Operational Area - Switch Room Contains cabinet-enclosed electronic equipment and automated switchgear to maintain the substation s primary functions. Accommodates a large quantity of metering and logging equipment. The cost and critical nature of the switch room equipment, and the requirement of continuous operation necessitates early warning smoke detection.

Challenges: Operational Area - Switch Room The electrical demand of the in-cabinet equipment is a major fire risk and the primary cause of a fire. Low thermal energy of an in-cabinet fire can effect the external detection of smoke during the incipient stage. High levels of airflow (ventilation) required by the cabinet-enclosed equipment to maintain a suitable operating temperature. Forced air ventilation increasing the incidence of smoke dilution and impeding detection by conventional systems.

Operational Area - Switch Room Recommendation: Ceiling Mounted & Cabinet Sampling. Ceiling Mounted: Sampling points are located as per the layout and configuration of the room and in accordance with local codes and standards. Cabinet Sampling: See Operational Area - Cabinet Protection

Operational Area - Office/Control Room Purpose: The main command centre of the substation that monitors and manages the entire site operation. The layout configuration can range from a small, nonventilated room, to a large, high airflow space with multiple operators and consoles. The consequential impact of downtime necessitates early warning smoke detection.

Operational Area - Office/Control Room Challenges: Cabinet-enclosed computer and control equipment. Smoke dilution can affect a conventional detector s ability to identify smoke at the crucial (incipient) stage of a fire.

Operational Area - Office/Control Room Recommendation: Ceiling Mounted & Floor Void Sampling. Locating sampling pipework on the ceiling and in the floor void provides the earliest detection at the crucial (incipient) stage. Additionally, the presence of cabinet enclosed equipment and consoles may necessitate direct in-cabinet sampling.

Operational Area - Office/Control Room Sampling Recommendation: Ceiling Mounted and Floor Void Sampling. Ceiling Mounted Sampling Floor Void Sampling

Purpose: Operational Area - Cabinet Protection Electrical, relay and communication equipment is typically located in enclosed cabinets. The cabinets are usually fully enclosed, or have a ventilation system. The ventilation system may either be via a top vented grille or as forced ventilation with fans or grilles located within the cabinet.

Challenges: Operational Area - Cabinet Protection The incidence of overheating is the main fire risk of cabinet-enclosed equipment and wiring. External detection of smoke by conventional systems may not register until a fire has progressed to an advanced stage and caused a significant amount of damage. Low thermal energy, poor ventilation, or forced incabinet ventilation can also affect the detection capability of conventional systems.

Operational Area - Cabinet Protection Recommendation: In-Cabinet & Above-Cabinet Sampling. In-Cabinet Sampling: Capillary tubes or drop pipes are inserted from either the top (Top Mounted) or bottom (Floor Void) of the cabinet. 1) Top Mounted - Sampling pipe is positioned over the cabinet and capillary tubes/drop pipes attached to the sampling pipe. The capillary tube/drop pipe should penetrate the cabinet to a recommended depth of 25-50mm (1-2 )*. * Unless specified otherwise.

Operational Area - Cabinet Protection Recommendation: In-Cabinet & Above-Cabinet Sampling. 2) Floor Void - Sampling pipe is located in the floor void with capillary tubes/riser pipes attached. Holes are drilled in the floor and base of the cabinet and the tubes/pipes are run through the cabinet and supported at top by a mounting clip. The sampling hole should face downwards and be located between 25-50mm (1-2 )* below the interior of the cabinet top. * Unless specified otherwise.

Operational Area - Cabinet Protection Recommendation: In-Cabinet & Above-Cabinet Sampling. Above-Cabinet Sampling: Sampling pipe is located directly over the ventilation grille of the cabinet and stand-off posts are used to mount the sampling pipe 25-200mm (1-8 )* above the grille. It is imperative that a minimum of one sampling hole is positioned in the direct airflow of the cabinet. * Depending on air movement.

Operational Area - Cabinet Protection Sampling Recommendation: In-Cabinet and Above-Cabinet Sampling. Capillary Sampling Above Cabinet Sampling Airflow

Purpose: Operational Area - Battery Rooms The substation s Uninterrupted Power Supply (UPS) is maintained in the Battery Room. The UPS is both a back-up power source and is also used to re-power the site in the event of a major outage. The size and configuration of a Battery Room is dependent on the power required by the UPS to operate the site.

Challenges: Operational Area - Battery Rooms Overheating cells and links, and failures in high current cables and bus bars expose the area to risk. The build up of hydrogen gas increases the risk of explosion.

Operational Area - Battery Rooms Recommendation: Ceiling Mounted & Exhaust Air Sampling Ceiling Mounted Sampling: Pipework is mounted 25-100mm (1-4 ) below the ceiling. The spacing, sample hole diameter and end cap vent size is determined using ASPIRE. Exhaust Air Sampling - Exhaust Air Grille: Pipework is positioned across the air grille of the exhaust ventilation system.

Operational Area - Battery Rooms Recommendations: Ceiling Mounted & Exhaust Air Sampling Exhaust Air Sampling - In-Duct: Sampling pipe ( probe ) is located across the width of the duct, and its centre line. Sampling holes are drilled into the probe and positioned 20-40º above or below the centre line. The in-take probe should be diagonally offset 300mm (1ft) to avoid air disturbances from the inflow of air.

Sampling Operational Area - Battery Rooms Recommendations: Exhaust Air Grille Sampling

Operational Area - Battery Rooms Sampling Recommendations: In-Duct Sampling Note 1: The entry and exit points of the probe must be sealed and airtight. Note 2: Separate detectors are required for Room and In-Duct Sampling. Probe Sampling Pipe Airflow

Purpose: Operational Area - Cable Trenches Cable Trenches house the communication, control and power cables that connect the operational areas of Control Room, Switching Room and Battery Room. Located underneath the substation, typically beneath the Switch/Relay Room, the cables connect the site s operational areas and transport power to the external high voltage switching towers.

Challenges: Operational Area - Cable Trenches Concentrated voltage that constantly travels along the cables. Classified as a hostile, confined space, the area exhibits an increased level of ambient pollution. Access difficulties are a primary consideration for general service/maintenance, and in the incidence of an emergency, the response to, and containment of fire.

Sampling Operational Area - Cable Trenches Recommendation: It is recommended that the pipework is positioned in the top 10% of the trench height. 10% of Trench Height

VESDA - the smart solution for optimum fire protection in Substations.