TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

Similar documents
Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

INTERNATIONAL STANDARD

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

Photobiological safety of lamps and lamp systems

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

AS/NZS IEC :2014

This document is a preview generated by EVS

Test Report issued under the responsibility of:

Amendment to Test Report

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

American National Standard for Safe Use of Lasers

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

G4 Pulsed Fiber Laser

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Important Safety Notice

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

Contains Nonbinding Recommendations. Draft Not for Implementation

*For inquiries and questions about lasers, see the Yellow-Page.

North Dakota State University Laser Safety

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

G4 Pulsed Fiber Laser

Policy Redesign Project. Laser safety. Table of Contents

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

American National Standard

w w w. p r o l i g h t. c o. u k USER MANUAL Order code: EQLA15

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

LASER SAFETY PROGRAM

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

Lasers and Laser Safety

Model No.: VS806-6N ( ) V~ 50/60Hz LED 6x4W

Rice University Laser Safety Manual

order code: EQLA08 user manual

Laser Safety Program

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

NEED FOR LASER SAFETY

Inspection Detail. General Questions for Laser Labs

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

Laser Safety Self-Audit Checklist

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

ANSI Z136.1-CDV Status on Updates for Next Revision & Work by TSC-4 Committee on Control Measures and Training

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

OWNERS MANUAL OPERATION GUIDE

Laser Safety Management

Provläsningsexemplar / Preview TECHNICAL REPORT. Safety of laser products. Part 8: Guidelines for the safe use of medical laser equipment

Rutgers Environmental Health and Safety (REHS)

LASER SAFETY BARRIER

TEST REPORT IEC MEDICAL ELECTRICAL EQUIPMENT

Laser Safety Products. Edition 20

Copy of marking plate:

3kW 6kW, QUBE Fiber Lasers

TECHNICAL REPORT. Safety of laser products. Part 10: Application guidelines and explanatory notes to IEC Sécurité des appareils à laser

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

CATALOGUE LASER POINTERS

Basic Laser Safety Training

Recommended Work Area Controls

University of North Florida Laser Safety Manual. Environmental Health and Safety Department

IECEE OPERATIONAL DOCUMENT

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Order code: EQLA21 user manual

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

LASER DIODE NX7637BF-AA

Test Report Iec En Household And Similar

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

Laser Safety for Laboratory Users

This is a preview - click here to buy the full publication

INTERNATIONAL STANDARD

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

64 Max IR Thermometer

Laser & Ultraviolet Light Sources Safety

Safety requirements for the projectors with laser device as light source

AS/NZS IEC :2013

Annex A to joint CELMA / ELC Guide on LED related standards: Photobiological safety of LED lamps and lamp systems

Laser Use Registration & Application (L.U.R.)

Laser Safety Citations

AS/NZS :2016

THE UNIVERSITY OF TEXAS RIO GRANDE VALLEY LASER SAFETY MANUAL. August 2016

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

AS 500. Instructions for Use. Version 1.0. December

Laser Safety Manual. Environmental Health & Safety Office 500 Summit Avenue Box Arlington, TX Phone Fax

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Light Detection and Ranging LiDAR and the FAA FAA Review and Reclassification of LiDAR systems

SYRACUSE UNIVERSITY S LASER SAFETY PROGRAM

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Transcription:

Test Report issued under the responsibility of: TEST REORT IEC 60825-1, 2 nd Edition art 1: Equipment classification and requirements Report Reference No....: EFSH15041135-IE-01-L01 Date of issue...: May 28, 2015 Total number of pages... 13 page Testing Laboratory...: Address... : Applicant s name...: Address... : Eurofins roduct Testing Service(Shanghai) Co.,Ltd No. 395 West Jiangchang Road, Zhabei District, Shanghai, China SHENZHEN BECEN OTOELECTRONICS SCITECH CO., LTD 6RD FLOOR 1 BUILDING, HUAFENG TECHNOLOGY ARK, FENGTANG ROAD, FUYONG, BAOAN, SHENZHEN, CHINA Test specification: Standard... : Test procedure... : Non-standard test method..: EN 60825-1 : 2007 (2nd Edition) Test Report Test Report Form No.... : Test Report Form(s) Originator... : IEC60825_1D Intertek Semko AB Master TRF... : Dated 2007-06 Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. Test item description... : Trade Mark...: Manufacturer...: Model/Type reference...: Ratings... : LASER OINTER BECEN Same as applicant BC-L# # CAN BE 01-29, 01-09 RED, 10-19 URLE, 20-29 GREEN DC 1.5*2 by battery

Testing procedure and testing location: Testing Laboratory: Testing location/ address...: Associated CB Laboratory: age 2 of 13 Report No. EFSH15041135-IE-01-L01 Eurofins roduct Testing Service (Shanghai) Co., Ltd No. 395 West Jiangchang Road, Zhabei District, Shanghai, China Testing location/ address... : Tested by (name + signature)... : Approved by (+ signature)... : Keith Wei Jerry Hu Testing procedure: TM Tested by (name + signature)...: Approved by (+ signature)...: Testing location/ address...: Testing procedure: WMT Tested by (name + signature)...: Witnessed by (+ signature)...: Approved by (+ signature)...: Testing location/ address...: Testing procedure: SMT Tested by (name + signature)...: Approved by (+ signature)...: Supervised by (+ signature)...: Testing location/ address... : Testing procedure: RMT Tested by (name + signature)...: Approved by (+ signature)...: Supervised by (+ signature)...: Testing location/ address...:

age 3 of 13 Report No. EFSH15041135-IE-01-L01 Copy of marking plate Summary of testing: Tests performed (name of test and test clause): 4. Engineering specifications 5. Labeling 6. Other informational requirements 7. Additional requirements for specific laser products 8. Classification 9. Determination of the accessible emission level Testing location: Eurofins roduct Testing Service(Shanghai) Co.,Ltd No. 395 West Jiangchang Road, Zhabei District, Shanghai, China Summary of compliance with National Differences: Group difference (there is no difference). Test item particulars:

age 4 of 13 Report No. EFSH15041135-IE-01-L01 Classification of installation and use... : Red light and green light is classified as Class 3R urple light is classified as Class 3B Supply Connection... : Battery... :... : ossible test case verdicts: - test case does not apply to the test object...: - test object does meet the requirement...: (ass) - test object does not meet the requirement...: F (Fail) Testing...: Date of receipt of test item...: April 24, 2015 Date (s) of performance of tests...: April 24, 2015 to May 28, 2015 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. General product information: The products covered in this test report are laser pointers for indoor only. All models are same appliances except different model name and different laser color. BC-L# # CAN BE 01-29, 01-09 RED, 10-19 URLE, 20-29 GREEN

age 5 of 13 Report No. EFSH15041135-IE-01-L01 4 ENGINEERING SECIFICATIONS 4.1 General remarks Modification 4.2 rotective housing 4.2.1 General 4.2.2 Service 4.2.3 Removable laser system 4.3 Access panels and safety interlocks 4.3.1 Access panels of protective housing roduct Class... : Accessible emission during removal of access panel... : The removal of the panel gives access to laser radiation levels designated by X in the table Accessible emissions after removal... : 4.3.2 Deliberate override mechanism 4.4 Remote interlock connector 4.5 Manual reset 4.6 Key control 4.7 Laser radiation emission warning 4.7.1 Class 3R (λ<400 nm; λ>700 nm), 3B and 4 4.7.2 Audible or visible warning 4.7.3 Operational control and laser aperture 4.7.4 Laser emission distributed through more than one output 4.8 Beam stop or attenuation 4.9 Controls 4.10 Viewing optics a) Human access to laser radiation in excess of Class 1M prevented when the shutter is opened or attenuation varied b) Opening of the shutter or variation of the attenuation prevented when exposure to laser radiation in excess of Class 1M is possible 4.11 Scanning safeguard 4.12 Walk-in access

age 6 of 13 Report No. EFSH15041135-IE-01-L01 a) Means provided so that any person inside the housing can prevent activation of a Class 3B or 4 laser hazard b) A warning device provides adequate warning of emission to any person within the housing c) Where walk-in access during operation is intended or reasonably foreseeable, emission of laser radiation that is equivalent to Class 3B or Class 4 while someone is present inside the enclosure of Class 1, Class 2 or Class 3R product shall be prevented by engineering means 4.13 Environmental conditions - climatic conditions - vibration and shock 4.14 rotection against other hazards 4.14.1 Non-optical hazards (product safety standard) - electrical hazards; - excessive temperature; - spread of fire from the equipment; - sound and ultrasonic; - harmful substances; - explosion; 4.14.2 Collateral radiation 5 LABELLING 5.1 General LASER RODUCT CLASS... : Class 3 Labelling location (roduct / User instruction / ackage) Warning label Hazard symbol (Figure 1) Explanatory label (Figure 2) roduct 5.2-5.6 Text on explanatory label... : LASER RADIATION AVOID DIRECT EYE EXOSURE CLASS 3R LASER RODUCT for purple light LASER RADIATION AVOID EXOSURE TO BEAM CLASS 3B LASER RODUCT for red and green light 5.7 Aperture label

age 7 of 13 Report No. EFSH15041135-IE-01-L01 5.8 Radiation output and standards information Max output of laser radiation... : ulse duration... : Emitted wavelength(s)... : The name and publication date of the standard... : Green light: 534.7nm Red light: 658.6nm urple light: 404.6nm 5.9 Labels for access panels 5.9.1 a) f) Warning wording used... : CAUTION CLASS 3 LASER LIGHT WHEN OEN DO NOT STARE INTO THE BEAM 5.9.2 Labels for safety interlocked panels Warning wording used... : 5.10 Warning for invisible laser radiation... : 5.11 Warning for visible laser radiation... : 6 OTHER INFORMATIONAL REQUIREMENTS 6.1 Information for the user a) adequate instructions for proper assembly, maintenance and safe use and description of the classification limitations, if appropriate b) warning for Class 1M and 2M c) laser beam parameters for radiation above the AEL of Class 1 Wavelength... : Beam divergence... : ulse duration... : Maximum power or energy output... : d) embedded laser products and other incorporated laser products e) ME and NOHD for Class 3B and Class 4 laser products For collimated beam Class 1M and 2M lasers the extended NOHD (ENOHD) f) information for the selection of eye protection g) reproduction of labels h) location of laser apertures i) listing of controls, adjustment of procedures and warning statement

j) information about laser energy source if not incorporated in the manual age 8 of 13 Report No. EFSH15041135-IE-01-L01 6.2 urchasing and service information a) safety classification of each laser product stated in descriptive material b) adequate instructions for servicing available 7 ADDITIONAL REQUIREMENTS FOR SECIFIC LASER RODUCTS 7.1 Applicable other parts of the standard series IEC/EN 60825 IEC 60825-2 (Safety of optical communication systems) IEC 60825-4 (Laser guards) IEC 60825-12 (Safety of free space optical communication systems used for transmission of information) Further information may be found in: IEC/TR 60825-3 (Guidance for laser displays and shows) IEC/TR 60825-5 (Manufacturer s checklist for IEC 60825-1) IEC/TR 60825-8 (Guidelines for the safe use of laser beams on humans) IEC/TR 60825-9 (Compilation of maximum permissible exposure to incoherent optical radiation) IEC/TR 60825-10 (Application guidelines and explanatory notes to IEC 60825-1) IEC/TR 60825-13 (Measurements for classification of laser products) IEC/TR 60825-14 (A user s guide) IEC 62471 (CIE S 009) (hotobiological safety of lamps and lamp system) 7.2 Medical laser products Class 3B and Class 4 medical laser products comply with IEC 60601-2-22 7.3 Laser processing machines Comply with IEC/ISO 11553-1 7.4 Electric toys Comply with IEC 62115 7.5 Consumer electronic products Complying with IEC 60950 or IEC 60065

age 9 of 13 Report No. EFSH15041135-IE-01-L01 8 CLASSIFICATION 8.2 Classification responsibilities 8.3 Classification rules 8.3a Radiation of a single wavelength Single wavelength 8.3b Radiation of multiple wavelengths 1) Laser product emission two or more wavelengths in spectral regions shown as additive in Table 5.. : 2) Laser product emission two or more wavelengths in spectral regions not shown as additive in Table 5... : 8.3c Radiation from extended sources... : Value of angular subtense (mrad)... : 8.3d Non-uniform retinal image radiance profile, noncircular and multiple sources 8.3e Time basis 1) 0.25s Class 3B 2) 100s Class 3R 3) 30000s 8.3f Repetitively pulsed or modulated lasers 1) Exposure from any single pulse not exceeding the AEL for a single pulse 2) Average power for a pulse train 3a) Constant pulse energy and pulse duration 3b) Varying pulse widths or varying pulse durations 9 DETERMINATION OF ACCESSIBLE EMISSION LEVELS 9.1 Tests Single fault eliminated Housing material withstanding degradation Fault detection 9.2 Measurement conditions... : 20-30 C Measured laser radiation... : See table measured laser radiation, calculations and comparison with AEL limits 9.3 Measurement geometry 9.3.1 General, evaluation scheme a) Simplified (default) method

age 10 of 13 Report No. EFSH15041135-IE-01-L01 b) Increased AEL by parameter C 6 9.3.2 Default (simplified) evaluation Condition applied... : Condition 2, Condition 3 Aperture stop diameter (mm)... : 7mm Measurement distance (mm)... : 70mm, 100mm 9.3.3 Extended sources C 6... : 1 9.3.3a Aperture diameters Condition applied... : Condition 2, Condition 3 Aperture stop diameter (mm)... : 7mm Angular subtense of the apparent source... : Green light: <1.5mrad Red light: <1.5mrad urple light: <1.5mrad 9.3.3b Angle of acceptance Condition applied... : Condition 2, Condition 3 1) hotochemical retinal limits... : 1.5mrad Angel of acceptance... : 1.5mrad 2) All other retinal limits... : Angel of acceptance... :

Measured laser radiation, calculations and comparison with AEL limits: age 11 of 13 Report No. EFSH15041135-IE-01-L01 1. Measuring condition - The radiant power is measured under normal and fault condition. - Measurement condition 1 is not measured, because it is obviously less severe than measurement condition 2 and condition 3. 2. Measured Results - Measured angular subtense: <1.5mrad Model Wavelength Normal condition Fault condition Using 7mm apertures stop at 70mm from source Green light 534.7nm 3.12mW - Red light 658.6nm 1.4mW - urple light 404.6nm 21.8mW - 3. AEL (Accessible Emission Limit) Every single AEL Emission duration Wavelength Radiant power AEL Class 100s 534.7nm 3.12mW 5.0 10-3 C6W = 5 10-3 W = 5mW 3R 100s 658.6nm 1.4mW 5.0 10-3 C6W = 5 10-3 W = 5mW 3R 0.25s 404.6nm 21.8mW 500mW 3B Remarked: <1.5mrad,C6=1 4. Classification green light and red light are is classified as Class 3R,urple light is classified as class 3B 5. Measuring Instrument Name Maker Model Serial No. Date expired Laser power meter Detector Newport Newport 1930-C 918-UV A0705478 A0705479 2016-04-23 Laser spectrum analyzer Newport OSM-400-UV-NIR A0705480 2016-04-27

Group difference age 12 of 13 Report No. EFSH15041135-IE-01-L01 National Differences for (country name) There is no special requirement

hoto: age 13 of 13 Report No. EFSH15041135-IE-01-L01 hoto 1 Overall view hoto 2 Internal view --------------------------------End of report--------------------------------