Circuit Breaker with Residual Current Protection (CBR)

Similar documents
Moulded case circuit brakers

Overload relays. General descriptions. Configuration of the front

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Residual Current Devices

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

VAMP 120 & 121. Arc flash detection units. Product picture

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

Three Phase Squirrel Cage Induction Motors

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Series G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Vacuum Interrupters. Outstanding vacuum-related manufacturing techniques of MEIDEN has

BA2702-P Linear Actuator

Control Panel Basics Volume 1

Innovators in Protection Technology Distribution Products including Instrumentation, Earth Leakage Protection & Power Factor Correction

DIGIHEAT IN LINE HEATERS

Welcome to Hager Presentation

Insulation fault evaluator EDS460-DG

Datasheet - MZM 100 B ST2-SD2PREM-A

* Consult factory on conditions for approval acceptability

Moulded Case Circuit breakers

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Datasheet - MZM 100 ST2-1P2PWREM-A

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Datasheet - MZM 100 ST-SD2PREM-A

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Instruction Manual. Immersible & Flange Type Transducer. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

AX51 with Munters Drive

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Vertical Type Electric Servo Drive Injection Molding Machine

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Beckhoff short profile

1.Application. 2.Main Technical Specifications B-10

MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Panel Mounted Fault Annunciator Series

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

Feed points. Optimize your material handling!

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Signal Tower. See More, Do More!

PROTECT SRB 200EXi-1A

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

RC Series Discharge Cones

Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

Operation and use. Functions and characteristics

ME 3011C / Alarm Indication / Quick Reference Guide

REA 105 Arc Protection Module. Operator s Manual

All Electric Servo Drive Injection Molding Machine

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

Molded Case Circuit Breakers, Bulletin 140G

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

AIR COOLED MINI CHILLER

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Arc Fault Protection System D1000

D1000 Arc-fault Protection System

CII FCAC-150 Series Relay

Ordering Key. Dielectric strength

Energy cost saving made easy!

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Dosing systems for dishwashing machines TWINDOSE SERIES

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

M15051) INSTRUCTION MANUAL

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

SB/ESB SERIES THERMAL PROTECTORS

RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers

Annunciator Unit SACO 16 D1. Product Guide

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Universal fault annunciator for panel mounting

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

I/A Series 716C 1/16 DIN Temperature Controller

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Transcription:

Circuit Breaker with Residual Current Protection (CBR) 3A-30mA-100mA-300mA-500mA-

Safety and protection are the prime purposes of Terasaki products. You care about safety and protection. The users of products you specify care about safety and protection. The new TemBreak2 CBR (Circuit Breaker with Residual current protection) provides protection from electric shock, overloads and short-circuits. Three types of protection are combined in a standard MCCB frame size. Read on to discover how to increase safety while saving space.

THE NEW TEMBREAK 2 CBR HOW DOES THE TEMBREAK2 CBR SAVE SPACE? 1. The TemBreak2 CBR has the same dimensions and fixings as the TemBreak2 MCCB. 2. The TemBreak2 CBR eliminates the need for either an external relay with current transformers or add-on block. FEATURES Voltage presence LED Trip Indicator: The yellow button pops up to indicate tripping due to residual current Type A: Tripping is ensured for residual sinusoidal AC in the presence of residual pulsating DC Test Button: Press the button to test the residual current detection and tripping system Adjustable residual current tripping thresholds. 30mA, 100mA, 300mA, 500mA, 1000mA and 3000mA Adjustable time delay for residual current protection. Settings include zero and non-trip (NT). Use NT setting with optional Residual Current Monitor (RCM) module. Dielectric test device. Remove the plug to allow dielectric testing with the CBR closed (ON) Adjustable overload protection. I r can be set between 63% and 100% of I n

OPERATING CHARACTERISTICS RESIDUAL CURRENT CHARACTERISTIC OVERLOAD CHARACTERISTIC SHORT-CIRCUIT CHARACTERISTIC I n is the adjustable tripping threshold for residual current (earth leakage) protection. It can be set between 30mA and 3A. Available settings are shown below: t (ms) is a time delay which is introduced to the residual current (earth leakage) protection characteristic. Available settings are shown below. It can also be set to 0 (max. actual tripping time is 40ms) or NT (No Trip - tripping time = ). The maximum breaking time at each setting is shown in brackets. Note that if I n is set at 30mA, t defaults to 0. I R is the adjustable tripping threshold for overload protection. It can be set between 0.63 and 1.0 times I n. Available I n ratings are shown below: I i is the tripping threshold for short-circuit protection. It is fixed at the values shown below: Model I n (A) t (ms) I n (A) I i ZE125, ZS125 0.03, 0.1, 0.3, 0.5, 1, 3 0 (40), 60 (195), 200 (365), 400 (620), 700 (950), NT ( ) ZE125, ZS125 0.03, 0.1, 0.3, 0.5, 1, 3 0 (40), 60 (195), 200 (365), 400 (620), 700 (950), NT ( ) ZE250, ZS250 0.03, 0.1, 0.3, 0.5, 1, 3 0 (40), 60 (195), 200 (365), 400 (620), 700 (950), NT ( ) ZE250, ZS250 0.03, 0.1, 0.3, 0.5, 1, 3 0 (40), 60 (195), 200 (365), 400 (620), 700 (950), NT ( ) 20, 32, 50, 63, 100 12 x I n (+/- 20%) 125 10 x I n (+/- 20%) 160 13 x I n (+/- 20%) 250 10 x I n (+/- 20%)

THE NEW TEMBREAK 2 CBR ACCESSORIES RESIDUAL CURRENT MONITOR AND REMOTE TRIP MODULE. *Normally open alarm contact (2A, 250V AC) closes on detection of residual current. Alarm threshold is adjustable *Green LED indicates voltage is present *Red LED provides visual indication of residual current *Can be configured to provide trip + alarm or alarm only *Remote trip terminals allow tripping by pushbutton *Can be configured to provide voltage drop protection A wire-sealing accessory is available to restrict access to the residual current protection settings The external accessories listed below are available for TemBreak2 CBRs. They are common to TemBreak2 MCCBs. For details and dimensions, refer to "TemBreak2, The Ultimate Safety Breaker, 07-I61EU". Terminal bars; cable clamps; rear connections; DIN rail mounting (ZE125 and ZS125 only); door-mounted handle; breaker-mounted handle; motor operator terminal covers for front connection; terminal covers for cable clamps; toggle lock. The internal accessories listed below are available for TemBreak2 CBRs. They are common to TemBreak2 MCCBs. For details, refer to "TemBreak2, The Ultimate Safety Breaker, 07-I61EU". Auxiliary switch and alarm switch.

RATINGS AND SPECIFICATIONS CBR ELECTRICAL CHARACTERISTICS TO IEC 60947-1, IEC 60947-2, IEC 60947-2 ANNEX B, IEC 60755 Frame Quantity Unit Condition 125 250 Note: All ratings are guaranteed when the CBR is reverse connected!* Model ZE125 ZS125 ZS125 ZE250 ZS250 ZS250 Type NJ NJ GJ NJ NJ NG Number of Poles 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 Nominal current ratings I n (A) 50 o C 20,32, 20,32, 20,32, 160, 160, 160, 50,63, 50,63, 50,63, 250 250 250 100,125 100,125 100,125 Electrical characteristics Rated operational voltage U e (V) AC 50/60 Hz 525 525 525 525 525 525 Rated impulse withstand voltage U imp (kv) Ultimate breaking capacity I cu (ka) 525V AC 22 25 10 25 25 (IEC, JIS, AS/NZ) 440V AC 15 25 50 15 25 50 400/415V AC 25 36 65 25 36 65 220/240V AC 35 50 5 35 65 5 Service breaking capacity I cs (ka) 525V AC 6 22 22 7.5 25 25 (IEC, JIS, AS/NZ) 440V AC 12 25 25 12 25 25 400/415V AC 19 36/30 36/33 19 36 36 220/240V AC 27 50 5 27 65 5 Protection Adjustable thermal, adjustable magnetic Residual current protection, Type A Utilisation category A A A A A A Installation Front connection (FC) Attached flat bar (FB) Solderless terminal (cable clamp) (FW) Rear connection (RC) Plug-in (PM) - - - - - - DIN rail mounting (DA) Dimensions height (mm) 155 155 155 165 165 165 width (mm) 3 pole 90 90 90 105 105 105 (mm) 4 pole 120 120 120 140 140 140 depth (mm) 6 6 6 6 6 6 Weight weight (kg) 3 pole 1.1 1.1 1.1 1.5 1.5 1.5 4 pole 1.4 1.4 1.4 1.9 1.9 1.9 Operation Direct Opening Action Toggle operation Variable depth/direct mount operating handle (HB/HP) Mechanical Interlocks - - - - - - Motor Operator (MC) Insulation Accessories Terminal covers and interpole barriers Switchboard Accessories Door Flange - - - - - - Toggle Lock Endurance Electrical cycles 415V AC Mechanical cycles 30,000 30,000 30,000 30,000 * Supply voltage connected to bottom terminals Standard Optional - Not Available

ORDER CODES 125A FRAME CBRS Model I R (A) 3P 4P 3P 4P with residual current monitor and remote trip module ZE125-NJ 12.5-20 4547560 622106 4547560 622205 4547560 622700 4547560 62209 I cu = 25kA 20-32 4547560 622113 4547560 622212 4547560 622717 4547560 62216 32-50 4547560 622120 4547560 622229 4547560 622724 4547560 62223 40-63 4547560 622137 4547560 622236 4547560 622731 4547560 62230 63-100 4547560 622144 4547560 622243 4547560 62274 4547560 62247 0-125 4547560 622151 4547560 622250 4547560 622755 4547560 62254 ZS125-NJ 12.5-20 4547560 622502 4547560 622601 4547560 623103 4547560 623202 I cu = 36kA 20-32 4547560 622519 4547560 62261 4547560 623110 4547560 623219 32-50 4547560 622526 4547560 622625 4547560 623127 4547560 623226 40-63 4547560 622533 4547560 622632 4547560 623134 4547560 623233 63-100 4547560 622540 4547560 622649 4547560 623141 4547560 623240 0-125 4547560 622557 4547560 622656 4547560 62315 4547560 623257 ZS125-GJ 12.5-20 4547560 622304 4547560 622403 4547560 62290 4547560 623004 I cu = 65kA 20-32 4547560 622311 4547560 622410 4547560 622915 4547560 623011 32-50 4547560 62232 4547560 622427 4547560 622922 4547560 62302 40-63 4547560 622335 4547560 622434 4547560 622939 4547560 623035 63-100 4547560 622342 4547560 622441 4547560 622946 4547560 623042 0-125 4547560 622359 4547560 62245 4547560 622953 4547560 623059 250A FRAME CBRS Model I R (A) 3P 4P 3P 4P with residual current monitor and remote trip module ZE250-NJ 100-160 4547560 64207 4547560 642906 4547560 644009 4547560 64410 I cu = 25kA 160-250 4547560 64214 4547560 642913 4547560 644016 4547560 644115 ZS250-NJ 100-160 4547560 643002 4547560 643101 4547560 644207 4547560 644306 I cu = 36kA 160-250 4547560 643019 4547560 64311 4547560 644214 4547560 644313 ZS250-GJ 100-160 4547560 643200 4547560 643309 4547560 644405 4547560 644504 I cu = 65kA 160-250 4547560 643217 4547560 643316 4547560 644412 4547560 644511 ACCESSORIES Refer to TemBreak 2, The Ultimate Safety Breaker, 07 I61EU for order codes for accessories

TERASAKI ELECTRIC (EUROPE) LTD. 0 Beardmore Way, Clydebank Industrial Estate Clydebank, Glasgow, G1 4HT, Scotland (UK) Telephone: 44-141-941-1940 Fax: 44-141-952-9246 marketing@terasaki.co.uk http://www.terasaki.com/ TERASAKI ITALIA s.r.l. Via Ambrosoli, 4A-20090 Rodano, Milano, Italy Telephone: 39-02-9227300 Fax: 39-02-9227320 info@terasaki.it http://www.terasaki.it/ TERASAKI ESPAÑA S.A.U. Pol. Ind. Coll de la Manya, Galileu Galilei, 19-21 0403 Granollers, Barcelona, Spain Telephone: 34-93-79-60-50 Fax: 34-93-70-39-05 terasaki@terasaki.es http://www.terasaki.es/ TERASAKI SKANDINAVISKA AB Fräsarvägen 32, SE-142 50 Skogås, Sweden Telephone: 46--556-22-30 Fax: 46--556-22-39 info@terasaki.se http://www.terasaki.se/ TERASAKI CIRCUIT BREAKERS (S) PTE. LTD. 9 Toh Guan Road East 03-01 Alliance Building Singapore 60604 Telephone: 65-6425-4915 Fax: 65-6425-4351 tecs@pacific.net.sg TERASAKI ELECTRIC (M) SDN, BHD. Lot 3, Jalan 16/13D, 40000 Shah Alam, Selangor Darul Ehsan, Malaysia Telephone: 60-3-5549-320 Fax: 60-3-5549-3960 terasaki@terasaki.com.my TERASAKI DO BRASIL LTDA. Rua Cordovil, 259-Parada De Lucas, 21250-450 Rio De Janeiro-R.J., Brazil Telephone: 55-21-3301-99 Fax: 55-21-3301-961 terasaki@terasaki.com.br http://www.terasaki.com.br TERASAKI ELECTRIC CO., LTD. Head Office: 7-2-10 Hannancho, Abenoku Osaka, Japan Circuit Breaker Division: 7-2-10 Kamihigashi, Hiranoku Osaka, Japan Telephone: 1-6-6791-9323 Fax: 1-6-6791-9274 int-sales@terasaki.co.jp http://www.terasaki.co.jp/ TERASAKI ELECTRIC (CHINA) LTD. 72 Pacific Industrial Park, Xin Tang Zengcheng, Guangzhou 511340, China Telephone: 6-20-270-556 Fax: 6-20-270-56 terasaki@public.guangzhou.gd.cn TERASAKI ELECTRIC GROUP SHANGHAI REPRESENTATIVE OFFICE Room No. 1405-6, Tomson Commercial Building 710 Dong Fang Road, Pudong, Shanghai, 200122, China Telephone: 6-21-5201611 Fax: 6-21-5201621 terasaki@vip.163.com Ratings and specifications are subject to change without notice. CAT REF. 0-P41E