Instructor Guide. Title: Tactical Approach to Chimney Fires. Time Required: 2 hours. Materials: PowerPoint presentation AV equipment

Similar documents
Chimney Fire Prevention

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

Rapid Intervention Team

Equipment: PowerPoint Presentation: Sprinkler Systems: Review and Response Considerations

Carbon Monoxide Poisoning

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Enactment Date: Rapid Intervention Team and RIT Officer

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

CHAPTER 8 CHIMNEYS AND VENTS

Required Materials For complete material(s) information, refer to

CHAPTER 8 CHIMNEYS AND VENTS

MSU Extension Publication Archive. Scroll down to view the publication.

5.3.5 Personnel accountability. Performance Test. Overhead transparencies, overhead projector, TV/VCR, exercise

I. It shall be the responsibility of the department officers to implement this operating guideline.

Incident Summary (II )

REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA ===============================================================

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service

CHIMNEYS AND VENTS CHAPTER 8

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

Smoke Management in High-Rise Structures

THELIN GNOME PELLET HEATER PLANNING & INSTALLATION GUIDE

Promotional Prep Fire Service Promotional Test Preparation

M MMG Insurance Company Presents A Guide for Woodburning Safety

Essentials of Fire Fighting 6 th Edition Firefighter I

FRS 201. Firefighters Advanced Skills I. 45 clock hours 3 credit bouts

Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

EASTERN ARIZONA COLLEGE Fire Department Operations II

Length of Course: 32 Hours Lecture/Lab Breakdown: 14/18

Structural Firefighting Policy

MASTER COURSE OUTLINE

Standardized Curriculum Form Ontario, Canada

Travis County Emergency Services District #1 Standard Operating Guidelines

Fire Department Orientation / Organization

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Venting of Gas Fired Equipment RV

GREEN SHEET. Los Angeles Fire Department. Informational Summary Report of Serious LAFD Injuries, Illnesses, Accidents and Near-Miss Incidents

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

OWNERS MANUAL LIBERATOR ROCKET HEATER Model: RMH-1

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

LIMITED LIFETIME WARRANTY

CHIMNEY INSTALLATION. Technical Bulletin #1

Pellet Vent INSTALLATION INSTRUCTIONS

Skill Sheet 17-I-1. Suppress an interior structure fire Direct, indirect, or combination attack. (NFPA 1001, , )

W / E / W / E / $10.00

tççç= ÜÉ~íáåÖ çéíáçåë

Fire Safety Plan (FSP) Review Checklist 1

Fire Safety Plan (FSP) Review Checklist 1

OWNER S MANUAL. DS Greenhouse Blast GH450. Do Not Discard This Manual. High Efficiency Wood or Coal Green House Furnace. Model:

Emergency Evacuation Plan South Patterson Building (SPB)

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner.

INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

Fireplaces and chimneys

1 Pre-Burn Plan Mandatory. 2 Pre-Burn Inspection Mandatory. 3 Pre-Burn Briefing Mandatory. 4 Instructor In Charge Mandatory

Public Safety Institute Fire & Rescue Course Fee Catalog

Guemes Island Fire Department

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

Additional Materials: Instructor s PowerPoint, Question Files

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Career Fire Fighter Dies While Exiting Residential Basement Fire - New York

Spokane County Fire District 10 Station 10-1 ~ 929 S Garfield Road, Airway Heights WA Station 10-2 ~ 5408 W Lawton Road, Spokane WA 99224

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

TACTICAL GUIDELINES. To provide guidelines to aid the decision making process for personnel during emergency/nonemergency

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

To provide guidelines to aid the decision making process for personnel during emergency/non-emergency incidents.

Elko County Human Resources Employment Opportunity Announcement

Travis County Emergency Services District #1 Standard Operating Guidelines

TITLE: Offensive and Defensive Operations

Talking about NFPA History of NFPA NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS

AMADOR FIRE PROTECTION DISTRICT

Public Comment No. 3-NFPA [ Chapter 7 ]

Program of Instruction Course Syllabus

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)

TABLE OF CONTENTS. Part I Administrative... 1

Manhattan Fire Protection District

Corn Flame Energy Corn Stove Model 3000

Retrofit Installer-Mechanical

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE II FIRE PROTECTION BUREAU. Assigned to: Name:

Please continue to check our website and look for the Playbook Updates Tab for further information and updates.

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

AIRPORT FIRE FIGHTER ID#: STANDARD:

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

Upon completion of this course, the student will be able to:

Lassen Community College Course Outline

Summary. firefighter training in Since that time the firefighter had attended semi-annual

Field Operations Guide (FOG) Effective Date: December 1, 2003 Last Revision Date: November 1, 2015

I. INTRODUCTION. A. Purpose: To provide procedures and guidelines for personnel responding to and operating at working structure fire incidents.

Transcription:

Instructor Guide Title: Tactical Approach to Chimney Fires Time Required: 2 hours Materials: PowerPoint presentation AV equipment Requisite Knowledge: Firefighter I Basic knowledge of company SOPs Requisite Skills: Firefighter I References: Avsec, Robert. "Taking the Fight out of a Chimney Fire." FireRescue1 News. FireRescue1, 18 Dec. 2013. Web. 4 Jan. 2015. Referenced from: http://www.firerescue1.com/fire-products/trainingproducts/suppression-equipment/articles/1636049-taking-the-fight-out-of-a-chimney-fire/. Lee, Michael. "Tactical Approaches for Chimney Fires." FireRescue1 News. FireRescue1, 8 Oct. 2008. Web. 4 Jan. 2015. Referenced from: http://www.firerescue1.com/fireproducts/tools/articles/432037-tactical-approaches-for-chimney-fires/.

Tactical Approach to Chimney Fires Motivation: Due to the seasonal nature of chimney use and lack of structured training on chimney fires in mainstream courses, many firefighters, especially firefighters with limited experience, find themselves ill-prepared to properly mitigate and manage incidents involving chimney fires. Training on how to properly handle a chimney fire can never come too early. Ensuring the proper extinguishment, utilization of salvage techniques, and prevention of fire spread can save a homeowner from further damage to their home in a chimney fire incident. Student Performance Objective(s) (SPOs): Given information from discussion, handouts, and reading materials, the student will be expected to describe the breakdown and anatomy of a chimney fire. The student will review causes of chimney fire inception, possible hazards associated with chimney fires and subsequent safety considerations, and methods of chimney fire extinguishment. The student will review the role of the fire ground personnel in mitigating a chimney fire incident. Enabling Objectives (EOs): Describe the characteristics of a chimney fire Review the construction of fireplaces, wood pellet stoves, wood stoves, and wood stove inserts Describe how creosote build-up exacerbates the progression of chimney fires Identify damage within the confines of a fireplace, flue, and chimney and possible fire exposure to the structure Discuss the importance of critical thinking in initial response Review equipment necessary to mitigate a chimney fire Identify safety considerations at a chimney fire incident Discuss the ICS system and how it pertains to task breakdown of chimney fire fireground operations and maintaining accountability throughout operations Review salvage techniques throughout operations and proper overhaul after fire is under control Overview: Characteristics of chimney fires Chimney anatomy and assemblies Causes and reasons for damaged chimneys ICS and fireground operations at chimney fire incidents Safety and accountability Extinguishment Salvage and overhaul

Lesson Plan I. Characteristics of chimney fires A. Explosive burning B. Noisy, low rumbles C. Turbulent Smoke D. Very high temperatures E. Cracks in thimble and flue pipe F. Smoke damage G. Roof/attic damage H. Chimney damage II. Chimney anatomy and assemblies A. Fireplace 1. Firebox 2. Ash pit and ash pit cover 3. Hearth 4. Cleanout door 5. Lintel 6. Damper and damper casing 7. Throat 8. Smoke chamber 9. Smoke shelf 10. Flue and flue tile liners 11. Roof line 12. Crown and cap B. Pellet Stove 1. Burner 2. Pellet hopper and pellet auger 3. Exhaust 4. Ash pit 5. Air inlet and heated air outlet C. Wood Burning Stove 1. Stove and stove pipe 2. Exhaust D. Wood Burning Stove Insert 1. Similar components as standard fireplace with an insert 2. Stove and stove pipe 3. Chimney flue liner III. Causes and reasons for damaged chimneys A. Creosote 1. Products of incomplete combustion that, when cooled, adhere to the inner lining of the chimney wall or flue 2. Highly combustible

IV. 3. Can be black or brown in color and crusty/flaky or tarry/dripping in consistency 4. Causes of creosote formation a) Incomplete combustion (1) Smoldering fires produce large amounts of creosote (2) Failure to clean chimney regularly will result in creosote buildup b) Cool surfaces (1) Exterior chimneys are harder to keep warm (2) If the fire is burning below 1100 degrees F, volatile gases escape and condense on relatively cooler surfaces c) Wet wood or green wood (1) Unseasoned softwoods form the most creosote B. 2,000 degrees F will begin to break down masonry work C. Crack in terracotta lining D. Metal chimneys under high heat conditions can warp seams and crack welds ICS and fireground operations at chimney fire incidents A. Response 1. Chimney fire dispatched - but is it only a chimney fire? a) Do not assume b) Think possible house fire and respond for house fire with full assignment c) Pull handline to front of house and charge to be ready to go d) Officer or first arriving should do a complete walk around of house B. Equipment necessary to combat chimney fires 1. Chimney brush 2. Tarps/runners, metal salvage bucket for salvage considerations 3. Dry chemical a) Extinguishers b) Chimney bombs - dry chemical packs 4. Small stove shovel 5. Thermal imaging camera to assess for extension 6. Mirror to view interior of chimney 7. Positive pressure ventilation fan 8. Heavy chain with metal cable a) Outdated in some areas C. Assignments 1. Utilize ICS system to ensure structure and accountability a) Incident Command (IC) b) Safety Officer c) Fire Attack Crew (1) Consider floor runners to ensure proper salvage (2) Open damper (3) Use dry chem. up the chimney to subdue the fire (4) Remove combustibles in metal salvage can (5) Remove vent pipe if needed

d) Roof/Chimney Crew (1) Safety considerations (a) Sound the roof to ensure roof integrity (b) Utilize a roof ladder for safety in roof operations (c) Ensure two means of egress (d) Wear full PPE and SCBA (2) Use chimney bombs (plastic bags with dry chem.) to put out the fire (3) Check the integrity of the chimney (4) Check for exposure to the roof e) Ventilation Crew (1) Set up positive pressure ventilation (PPV) fan (2) Create appropriate openings for movement of gaseous products of combustion f) Exposure Crew (1) Check for extension along chimney area (2) Check attic and second floor for extension (a) Utilize TIC to assess for hot spots (3) Pull back up handline (4) Ensure egress for crews working interior (a) Ladders (5) Help with ventilation V. Safety and accountability A. Full PPE and SCBA for everybody B. Use of aerial apparatus for better, safer accessibility C. Use TIC to check for hot spots and extension D. Crew integrity and accountability 1. Regular PAR checks 2. Work in teams of two or as a group, no freelancing E. Communicate! 1. Communication consistent between all crews operating on the fireground (a) Before use of dry. chem up the chimney stack, ensure personnel operating on the roof are aware (b) Conversely, communicate to crew at firebox before dropping chimney bombs down the flue VI. Extinguishment A. Extinguish and remove fuel from firebox B. Dry chem. in bags dropped down the chimney 1. Dry chem. sealed in plastic bags (e.g. Ziplock) 2. Drop sealed bags down flue toward draft stop 3. Heat within the flue will melt bags to release dry chem. for fire extinguishment C. Dry chem. extinguisher from the base of the flue 1. Coordinate opening of draft stop with release of dry chem. from extinguisher at base of flue

VII. a) Ensure proper coordination, as opening of the draft stop may initially accelerate the fire 2. Expel dry chem. extinguisher up the flue a) Heat will carry the dry chem. up the flue b) Consider utilizing salvage tarps before beginning due to the potential for mess and damage D. Utilize PPV to force dry chem. up the chimney and ensure ventilation 1. Ensure all other openings in the structure are closed to ensure pressurization of fire room 2. Use PPV fan to pressurize room 3. Expel dry chem. extinguisher in coordination with ventilation with PPV fan a) Consider use of a tarp to control the opening of the fireplace to limit the amount of ventilation going up the chimney so that dry chem. has time to extinguish the fire E. Chimney chain 1. Outdated 2. Utilized to knock packed creosote and other products of combustion off the interior walls of the chimney and flue Salvage and overhaul A. Salvage 1. Consider salvage covers and floor runners to reduce damage to property 2. Metal salvage can to collect debris from the chimney B. Overhaul 1. Utilize TIC to check for hot spots and extension 2. Make sure fire is completely out to remove risk of rekindle 3. Account for personnel 4. Fireplace requires inspection before homeowner may continue use Overview: Characteristics of chimney fires Chimney anatomy and assemblies Causes and reasons for damaged chimneys ICS and fireground operations at chimney fire incidents Safety and accountability Extinguishment Salvage and overhaul Summary: Due to the seasonal nature of chimney use and lack of structured training on chimney fires in mainstream courses, many firefighters, especially firefighters with limited experience, find themselves illprepared to properly mitigate and manage incidents involving chimney fires. Training on how to properly handle a chimney fire can never come too early. Ensuring the proper extinguishment, utilization of

salvage techniques, and prevention of fire spread can save a homeowner from further damage to their home in a chimney fire incident. Practical: Our practical included a 40 gallon, metal barrel (a mock fireplace) lying on its side, with one end open, placed approximately 2 of the ground with bricks. On top of the barrel was a 2 hole. Protruding from the hole was a 6 long, 2 round, metal pipe (a mock chimney). The pipe was lined with one piece of paper on the inside of the pipe (to form mock creosote). We used excelsior as firewood and created a chimney fire. Utilizing the three methods of extinguishment, we were able to demonstrate putting out the fire by all 3 methods. Please use specific safety precautions and proper PPE when doing this practical. Addition materials needed: dry chemical extinguisher, dry chemical filled plastic bags, modified to be small enough to drop down 2 pipe, a small fan used for PPV and a small, noncombustible cover to go over opening of the barrel. An A-frame ladder will also need to be utilized to drop bombs down the pipe.