C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Similar documents
C7232A,B Sensor and Controller

T7079A,B Solid State Remote Temperature Controllers

Commercial/Industrial Combustion Control Level Three Announcement

C554A Cadmium Sulfide Flame Detector

T4398A,B High Performance Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats

T6984F,G Electronic Floating Control Thermostats

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

T7984 A,B,C Electronic Modulating Control Thermostats

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

The T6140A,B Remote Bulb Temperature Controller

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

CR7075 Two-Stage Lighting Controller

C6097A,B Pressure Switches

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

RA889A Switching Relay

T6984 A,D,E Electronic Floating Control Thermostats

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

F150E Media Air Cleaner

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

F25F Media Air Cleaner

T8411R Electronic Heat Pump Thermostat

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

T8011R Programmable Heat Pump Thermostat

L8151A Triple Aquastat Relay

F200E Charged-Media Air Cleaner

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

C7004B Flame Rod Holder

T834C Heating-Cooling Thermostat

C7005A,B Gas Pilot and Flame Rod Assemblies

T874 Multistage Thermostat and Q674 Subbase

M6063A Compact Rotary Mixing Valve Actuator

Instructions For A and Flame Simulators

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

H1008A,D Automatic Humidity Controls

T4398A,B Precision Electric Heating Thermostat

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

T8524 Deluxe Electronic Thermostat

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Deluxe Programmable Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats

Deluxe Programmable Heat Pump Thermostat T8611M

IS Series Pressure Sensing Switches

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

T8600D Chronotherm IV Deluxe Programmable Thermostats

Datasheet: K-22 LO Sensor

Accuracy by Design Products for the HVAC Professional

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

RA889A Switching Relay

HE365A,B Powered Flow-Through Humidifier

T8611M Deluxe Programmable Heat Pump Thermostats

RA890G Protectorelay Primary Control

Oxygen (O2) Single-Point Gas Detection System

HE220, HE260 Humidifier Installation Kit

Sensor Selection Guide. Sensing for Building Applications

Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

F59A Console 3-Speed Electronic Air Cleaner

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

AQ255 and AQ257 Series Expansion Zoning Panels

D896 Automatic Vent Damper

esense CO2 Transmitter and Alarm

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

Duct and Rough Service Carbon Monoxide Sensor

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

Q7300L Series 2000 Commercial Thermostat Subbases

CT500 Electronic Thermostat

AQ250 Series Hydronic Control Panels

HE420A Steam Power Humidifier

Must be installed by a trained, experienced technician

C7915A Infrared Flame Detector

Analog Room Pressure Monitor RPC Series

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

P7810A-D Pressuretrol Controller

CR Series Command Relays

Q7300H Series 2000 Commercial Thermostat Subbases

7800 SERIES RM7888A Relay Module

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SIL3. C7961E,F Dynamic Self-Check Ultraviolet Flame Detector. Capable APPLICATION FEATURES PRODUCT DATA. Contents

T8112 Programmable Thermostat

7800 SERIES EC7885A/RM7885A Relay Module

Transcription:

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR PRODUCT DATA C7232A C7232B FEATURES Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information. Non-Dispersion-Infrared (NDIR) technology used to measure carbon dioxide gas. Gold-plated sensor provides long-term calibration stability. Device provides voltage or current output based on CO 2 levels. Models available with SPST relay output. Automatic Background Calibration (ABC) algorithm based on long-term evaluation reduces required typical zero-drift check maintenance. APPLICATION The C7232 Sensor and Controller is a stand-alone carbon dioxide (CO 2 ) sensor for use in determining ventilation necessity with HVAC controllers. The C7232 measures the CO 2 concentration in the ventilated space or duct. The C7232 is used in ventilation and air conditioning systems to control the amount of fresh outdoor air supplied to maintain acceptable levels of CO 2 in the space. Contents Application... 1 Features... 1 Specifications... 2 Ordering Information... 2 Installation... 3 Wiring... 4 Checkout... 5 Appendix... 6 63-2571-08

SPECIFICATIONS Models: C7232 Sensor and Controller. A stand-alone carbon dioxide (CO 2 ) sensor with two jumper-adjustable outputs (one analog and one SPST relay). C7232A: Wall mount model. C7232B: Duct mount model. Wiring Connections: C7232A: 20-gauge cable with six 8 in. leadwires. C7232B: 20-gauge cable with six 6 in. leadwires. Mounting: C7232A: Vertical surface with standard single-gang junction box. C7232B: Sheet metal duct with a sampling tube. NOTE: Models are available with or without a 4-digit LCD that indicates the current CO 2 concentration. Dimensions: C7232A: See Fig. 1. C7232B: See Fig. 2. Sensor Performance Ratings: Response Time: 1 min. Carbon Dioxide Sensor: Operation: Non-dispersive infrared (NDIR). Sampling: Diffusion. Range: 0 to 2000 ppm Accuracy: ± (30 ppm +2% of reading)*. * This product complies with Title 24 Part 6, CEC Standard for Residential and Non-Residential Buildings 2005, when installed according to instructions. Electrical Ratings: Power Supply: 24 Vac/dc ±20%, 50/60 Hz (Class 2). Maximum Power Consumption: 3W. Peak Current (at 20 ms): 600 ma. Relay: Configuration: Shipped N.O. Contact Rating: 1A at 50 Vac/24 Vdc. Minimum Permissible Load: 1 ma at 5 Vdc. Linear Analog Output: Voltage: 0/2-10 Vdc (resistive load greater than 5000 ohms). Current: 0/4-20 ma (resistive load less than 500 ohms). Outputs (Jumper Adjustable, see Table 2): Analog: 0-10 Vdc (Default: 2-10 Vdc, 500 to 1500 ppm). Relay: Normally Open SPST (Default: Close at 800 ppm). Ambient Ratings: Temperature: Operating: +32 F to +122 F (0 C to +50 C). Storage: -4 F to +158 F (-20 C to +70 C). Relative Humidity (non-condensing): 0 to 95 percent. CO 2 Pressure Dependence: 1.4% change in reading per 1 kpa deviation from 100 kpa. ORDERING INFORMATION Automatic Background Calibration (ABC) default: On. Calibration: This product is factory calibrated. No field calibration is necessary for the life of this product. Approvals: CE Underwriters Laboratories Inc. Listed, File No. E4436 cul C7232B: Flammability Rating, UL94-5V C7232A: NEMA1 C7232B: NEMA3 Fig. 1. C7232A dimensions in inches (mm). Fig. 2. C7232B dimensions in inches (mm). When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 1 (25) 5-1/16 KNOCKOUTS FOR EUROPEAN APPLICATIONS STANDARD UTILITY CONDUIT (128) 2-3/8 BOX (60) (2X4) MOUNTING HOLES 3-5/32 (80) 3-5/16 (84) 1-13/16 (46) M17592 5-5/8 (142) 1-5/8 (41) 2-3/8 (60) 8 (203) M17540A 63-2571 08 2

INSTALLATION When Installing this Product... 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. All wiring must agree with applicable codes, ordinances and regulations. Health Hazard. Improper use can create dangerous situations. Use in application for sensing carbon dioxide only. For life-safety applications, this device can function only as a secondary or lesser device. Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. Equipment Damage Hazard. Electrostatic discharge can short equipment circuitry. Ensure that you are properly grounded before handling the unit. C7232A Cover Removal/Replacement C7232A Cover Removal (see Fig. 3) 1. Remove button head socket cap screw and set it aside. 2. Insert the head of a small screwdriver into the slot at the center and near the top of the cover. 3. Gently pull the handle down toward the bottom of the device until a small gap between the subbase and the cover appears. 4. Remove the screwdriver and pull the cover straight down until it meets a stop. 5. Pull the cover straight off the subbase. Fig. 3. C7232A cover removal. C7232A Cover Replacement 1. Feed the wires through the opening in the subbase. 2. Place the cover, with a small gap at the top, flat on top of the subbase. 3. When the cover rests flat on the subbase, slide it straight up until it latches in place. Location and Mounting C7232 Sensors mount directly on the wall, sheet metal duct, or a panel. When planning the installation, allow enough clearance for maintenance and service. Mount the sensor in a well-ventilated area. NOTES: M17541 B BUTTON HEAD SOCKET CAP SCREW A ALLEN TOOL Do not install the sensor where it can be affected by: drafts or dead spots behind doors and in corners. air from ducts. Sensor must be mounted in a location which sees at lease one 4-hour unoccupied period per week so that the CO 2 level drops to outdoor levels. Automatic Background Calibration will not work properly in locations without four hours of unoccupied time per week, or where there are sources of CO 2 other than people (breweries, mushroom farms, etc). This sensor is not for use in highly corrosive environments. C 3 63-2571 08

Wall Mounting The C7232 Wall Mount models can be mounted using two or four screws: 1. Remove C7232 cover. 2. Mount the subbase to the wall using washers and two or four screws (not supplied) appropriate for the wall material. NOTE: When mounting on a junction box, see Fig. 4. 3. Replace the cover. STANDARD UTILITY CONDUIT BOX FRONT COVER BUTTON HEAD SOCKET CAP SCREW NO. 6 SCREW Fig. 4. Junction box mounting (C7232A). Duct Mounting (see Fig. 5) 1. Place gasket on aspiration tube. NO. 6 SCREW SUBBASE M17542 Ensure largest tab at tube control end is at the top. 2. Insert tube into duct; attach using screws and washers. Leakage into the duct or the C7232 box cover from the room will skew the sensor readings. Ensure the box cover and duct seal completely. 3. Place O-ring on tube end; mount the control to the tube. FLOW WIRING The factory ships the device with the output default settings shown in Tables 2 and 3. Set the jumpers and wire the device (see Table 1 and Fig. 6). Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. Equipment Damage Hazard. Electrostatic Discharge Can Short Equipment Circuitry. Ensure that you are properly grounded before handling the unit. 1. All low voltage connections to this device must be 24 Vac Class 2. 2. All wiring must comply with applicable local codes, ordinances and regulations. Table 1. C7232 Wiring Connections (see Fig. 6). Wire Color Designation Function Red G+ 24 V Hot Black G0 24 V Common Yellow OUT1 Analog Output Signal Brown M Analog Output Common Orange NO Relay Output Normally Open Green COM Relay Output Common C7232 24V ANALOG OUT + RED BLACK YELLOW BROWN ORANGE GREEN L1 (HOT) L2 1 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M17543A Fig. 6. Wiring the C7232. M17591 Fig. 5. Duct mounting (C7232B). 63-2571 08 4

Input Signal The C7232 Sensors have an adjustable range. These ranges are determined by the SW1 and SW2 jumper settings (see Table 2). Table 2. CO 2 Range Jumper Settings SW1 SW2 AN (ppm) Relay a (ppm) On On 0 to 1000 1000 On Off 0 to 2000 1200 Off b On b 500 to 1500 800 Off Off 500 to 2000 1200 a When the level reaches this value, the contacts close; when the level drops 100 ppm below this value, the contacts open. b Setting when shipped from the factory. Output Signal The output signal can be adjusted for 0/2-10 Vdc or 0/4-20 ma (see Table 3). Table 3. Output Signal Jumper Settings OUT AN 0-100% 20-100% Voltage 0-10Vdc 2-10Vdc Current 0-20 ma 4-20 ma NOTES: On duct models, remove the screw holding the board in place to view jumper settings on reverse. (See Fig. 7.) The CO 2 settings and the output signal settings are independent of each other. 0-100% and 20-100% are simply markings for the OUT jumper settings on the sensor (to differentiate between the two voltage and the two current ranges) and do not refer to or alter the ppm range chosen. SW2SW1 OUT OFF ON OFF ON 0 100% 20 100% AN Voltage Current Fig. 7. C7232 default jumper settings. M19424 Example For a CO 2 setting of 0-2000 ppm and a voltage output of 0-10 Vdc, the output would be as shown in Table 4 (arbitrary points along the analog curve). Table 4. 0-10 Vdc Output Example. CO 2 Level (ppm) 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Voltage Output (Vdc) 0 1 2 3 4 5 6 7 8 9 10 For a CO 2 setting of 0-2000 ppm and a voltage output of 2-10 Vdc, the output would be as shown in Table 5 (arbitrary points along the analog curve). CHECKOUT Perform a quick test of the unit with the unit powered: 1. Stand close to the unit and breathe air into the sensor. 2. Check the CO 2 level registered by the controller to ensure a strong rise. 3. When connected to a damper in a ventilation system, the controller typically signals an increase in air flow. Table 5. 2-10 Vdc Output Example. CO 2 Level (ppm) 0 250 500 750 1000 1250 1500 1750 2000 Voltage Output (Vdc) 2 3 4 5 6 7 8 9 10 5 63-2571 08

APPENDIX This page is only for models with date code prior to 0309. Pre 0309 Date Code Jumper Settings Input Signal The C7232 Sensors have an adjustable range. These ranges are determined by the SW2 and OUT1 jumper settings (see Table 6). NOTE: a b c d When choosing analog output, be sure to set the SW1 jumper to the On position. Table 6. CO 2 Range Jumper Settings for models with date code prior to 0309. Jumper SW1 Jumper SW2 Jumper Setting On a Off On a Off OUT1 b AN1 X c 0 to 1000 0 to 2000 AN2 a X c 500 to 1500 500 to 2000 Relay Switching b X 800 d 1200 d X 1000 d Setting when shipped from the factory. OUT1 jumper setting does not affect the Relay Switching. The analog output will not work properly when SW1 is Off. When the level reaches this value, the contacts close; when the level drops 100 ppm below this value, the contacts open. Output Signal The output signal can be adjusted for 0/2-10 Vdc or 0/4-20 ma (see Table 7). Table 7. Output Signal Jumper Settings for models with date code prior to 0309. AN1 and AN2 (set OUT both the same) 0-100% 20-100% Voltage 0-10Vdc 2-10Vdc Current 0-20 ma 4-20 ma NOTES: On duct models with date code prior to 0309, remove the screw holding the board in place to view jumper settings on reverse. (See Fig. 8.) The CO 2 settings and the output signal settings are independent of each other. 0-100% and 20-100% are simply markings for the OUT jumper settings on the sensor (to differentiate between the two voltage and the two current ranges) and do not refer to or alter the ppm range chosen. SW2SW1 OUT OFF ON OFF ON 0 100% 20 100% AN2 AN1 OUT1 Select Voltage Current Voltage Current AN1 AN2 M20494 Fig. 8. C7232 default jumper settings for models with date code prior to 0309. 63-2571 08 6

7 63-2571 08

Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com U.S. Registered Trademark 2008 Honeywell International Inc. 63-2571 08 M.S. Rev. 06-08