EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS

Similar documents
Emergency Voice Communication System (EVCS) Consu ltant s Specific atio n CONTENTS

Care2 EVC CARE 2 EMERGENCY VOICE COMMUNICATION RADIAL WIRED SYSTEM BENEFITS: FEATURES:

Folknoll Group Ltd. DISABLED REFUGE EVC BS :2011COMPLIANT TOUGH, VANDAL RESISTANT IDEAL FOR PUBLIC USE

Cooper Fire Systems. Emergency Voice Communication

A BRITISH MANUFACTURER

1 to 64 line emergency voice communication system

1 to 64 line emergency voice communication system

Channel Orbital Refuge

EMERGENCY ASSISTANCE ALARMS

Fire detection and alarm

Intelligent Security & Fire Ltd

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Policy for Safe Evacuation of Persons with Disabilities

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Advanced FireAlarm Panel 1-4Loop

Disabled persons toilet alarm kit from Cameo Systems

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Extending Your Potential. Product Range

Engineer Paging. Staff Paging. Deaf Alert.

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

Guidance for writing a Personal Emergency Evacuation Plan (PEEP)

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website: EQUALITY ACT 2010

ID2000. intelligent fire alarm panel

Public Address and Voice Alarm. Version 1 DESIGN & INSTALLATION GUIDE

Product Data Sheet. Remote Terminals. Features:

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

(Fire) Emergency Evacuation Plan

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

ZXSe Range Data Sheet

Chapter 6: Plumbing Elements and Facilities. 603 Toilet and Bathing Rooms Wheelchair Accessible Compartment

Components Brochure DX CONNEXION

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Reviewed: DD Month Emergency Evacuation of People with a Disability Options Matrix for Developing a PEEP

OmniCare EVC System. Installation & Commissioning Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Technical reference Reference & design

Charlotte Building, 17 Gresse Street, London W1T 1QL

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

N-8000 SERIES IP INTERCOM SYSTEM

Fire Evacuation Procedure Stroud Campus

Solution Sheet. Communicall Vi. Leading housing technology solutions for supported living

Bosch Plena Public Address and Voice Alarm System The fast route to safety

a guide to the interpretation of

DEF Fire Evacuation and Emergency Planning Criteria

BS 5839: Part THE CHANGES

Your Lifeline Vi+ home unit. Your MyAmie pendant

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Saxon Range 1-8 Zone Convertional Control Panels

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

Intelligent Security & Fire Ltd

The PUZZLE receiver that uses light patterns to notify the user of visitors, calls, and alarms.

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (Student Halls of Residences & Sleeping Accommodation)

Interface Modules for SENTRI

The EN54 Part 2, 4 and 13 Fire System

Emergency Voice Communication Systems

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Reliably Advanced Extinguishing Control

Vocia VACIE. Reference Guide

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Control Panel User Guide

Fact File 75. Published Document PD CEN/TS 54-32:2015 Fire detection and fire alarm systems

Digital Door Entry System. Specification

Distributed Amplifier Unit (DAU) (EESDAU100) Emergency Microphone All Call (EMA) (EESEMA) User Operational & Maintenance Manual

VACIE REFERENCE GUIDE REVISION 1.2.6

APPLICATION DATA SHEET

SECURE LIFE SAFETY PAGA

Control Panel User Guide (TO BE RETAINED BY THE USER)

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Fire detection and alarm system Operating instructions

Reliably Advanced Extinguishing Control

EMERGENCY EVACUATION PLAN

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

CALL FOR A FREE SURVEY

SilentMAlert. ClofieldMLimited. ProductMDataMSheetsM. PagingMSystem. Silent

Simplify. Secure. Your Home. Your Life. M1 Security & Automation Controls

DCS-100. intelligent damper control & monitoring system

Lifeline Vi Clever, not complicated

The EN54 Part 2 & 4 Fire System

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

ID3000 intelligent. fire alarm panel

AVCOM System Installation Instructions

ID3000 intelligent. fire alarm panel

Fire Control Panel FS5100

SOUTH AFRICAN NATIONAL STANDARD

Hospitals and senior living facilities can be treacherous places in the event of a fire or smoke emergency.

3.1 Introduction. 3.1 Introduction

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Transcription:

EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS

An EVCS (emergency voice communication system) or Disabled Refuge System is designed for use in buildings that contain refuge areas. This type of intercom system allows emergency services to be in constant contact with the people in the refuge areas who seek assistance. The Equality Act (formerly The Disability Discrimination Act) made it the responsibility of all companies, nationwide, to ensure that access to buildings and services is available to everyone - there must be no discrimination. With access provided for all, provision must be made for safe evacuation in the event of an emergency. In some circumstances, those with physical impairments can be assisted by others - but in many situations this is not suitable or safe. A solution comes in the form of temporary areas of safety - refuge areas. The person in need of assistance is helped to the closest refuge area and awaits safe evacuation. Refuge areas must meet certain criteria, these are covered in BS9999:2008. As well as describing suitable areas for refuge and the type of construction, the Standard specifies the need for two way communication. An EVCS allows firefighters and others to communicate with one another during emergency situations. The system also allows communication with disabled persons. It is a system that allows voice communication in either direction between a central control point and a number of other points throughout a building or building complex, particularly in a fire emergency situation. (BS5839-9:2011 3.4). 02

BS 5839-9:2011 Fire detection and alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems Executive summary Recommendations for the planning, design, installation, commissioning and maintenance of emergency voice communication systems in buildings. Abstract This British Standard, a part of the BS 5839 series, provides recommendations for the planning, design, installation, commissioning and maintenance of emergency voice communication (EVC) systems in and around buildings and at sports, entertainment and similar venues. It ensures that high standards of reliability, safety and security are achieved, together with acceptable standards of performance. This code of practice primarily relates to the use of EVC in assisting both firefighters and those responsible for evacuating buildings or sports stadia in fire emergency situations, including evacuation of disabled persons. Use, other than in fire emergency situations, by disabled persons and others, although not precluded, is not addressed in detail. In the context of this code of practice, an EVC system contains no portable parts. Mobile telephones and twoway radio sets are therefore not within its scope. Voice alarm systems are primarily intended for the automatic broadcasting of evacuation messages are excluded from this code of practice. This British Standard does not recommend whether or not an emergency voice communication system should be installed in a given premises. This part of BS 5839 does not cover systems combining electrically the functions of EVC systems with functions of other firerelated or non-fire-related systems. This part of BS 5839 applies only to emergency voice communication systems for use in a temperate climate such as that of the United Kingdom. EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) 03

EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) The Compact 9 System The Compact 9 System is ideal for small to medium sized installations which don t require the complexity of a full network solution. Key Features BS5839 part 9 (2011) compliant 4 navigation keys 6 status LED s 4 line, 20 character LCD Simple menu programming Contact outputs to interface with Fire Detection or Voice Alarm Systems Benefits 04 Using the 10 Line Exchange unit extends the system to 19 communication lines In addition to Type A and Type B Outstations it can also monitor Emergency Assist Alarms (using a 2 core radial) Connection between the exchange unit and slave is achieved using standard 4 core fire rated cable This system comprises of the 9 Line Master Exchange Unit and up to 9 Outstations (Type A, Type B, or Emergency Assist Alarms). Using the 10 line Slave Exchange Unit this system can be easily expanded to 19 lines. The Compact 9 is modular in design and the controller manages all functions for the first 9 zones. There is no need for additional equipment such as power supplies. The Compact 9 Line Master Exchange Unit is a self contained enclosure housing a Master Handset, 9 Line Exchange, power supply, and battery charger. It can be surface or semi-flush mounted as standard. TYPICAL System Architecture 4 core fire rated cable

The Network 8 System The Network 8 EVCS modular architecture is ideal for use in larger buildings with up to 256 communications zones. Suitable for use in high rise buildings as well as large complexes such as schools and universities. Key Features Each Exchange can control up to 8 independent monitored lines Controls up to 256 Lines (32 exchanges) Built in monitored 1A battery charger 12 status LEDs Dry contact for fault or in-use indication Serial port for configuration or updates Dual network ports which provide power for the master handsets The Network 8 System greatly reduces the cabling requirement and equipment on view in such key places as reception areas, making the system much more aesthetically pleasing to the customer as well reducing the cost of installation. The system is controlled by the Network Master Handset. It is possible to add up to 7 additional master handsets allowing the Network 8 to deliver a highly flexible emergency management strategy. Larger systems are built using a series of Exchange Units connected to a loop network providing cost effective and secure installations. TYPICAL System Architecture Benefits Clear LED indication on the Exchange Unit for effective & easy fault fi nding Can be easily connected to a fi re panel or BMS Upload information quickly via a PC using the serial port Distributed system architecture, no central exchange rack required EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) 05

EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) Type A Outstation The Type A Outstation is compatible with all EVCS systems for use as a standard Fire Telephone or Disabled Refuge call point. Key Features Compact design High volume ringer Status LED Telecoil for hearing impaired users Full duplex operation Automatic dialling when off hook Benefits Can be used on all Gent EVCS systems providing compatibility across the range Can be used as a fi re telephone or a disabled refuge call point Magnetic push catch, for quick and easy access The Type A Outstation is a compact unit which offers easy access via a magnetic push catch door. The flush mountable unit offers a unique front levelling system allowing the back box to be mounted at a slight angle whilst still retaining a true front face and door. A surface mountable unit is also available. Fire telephones are hardwired full duplex communications systems with monitoring and battery backup, and are required in buildings over 4 stories in many countries in the world (in the UK this is governed by BS 9999). These are provided as a backup to traditional fireman s radio systems, which can fail to operate in many high rise environments due to the large amount of steel in the building, and the corona effect of fire on radio broadcasts. 06

Type B Outstation The Type B Outstations are designed to be versatile, compact and provide an easy to use refuge call point. Key Features Compact design Loop output for hearing impaired users Full duplex operation, allowing 2 way voice communication High volume ringer Status LED Flush bezel available All Type B Outstations are defined in BS 5839 part 9 and can be used as a Fire Telephone or Disabled Refuge call point. The Type B Outstation is available in red, green and stainless steel. Tactile braille signage assists partially sighted people to easily operate the Refuge Point. Choosing outstation type When choosing the Outstation type for use with an EVCS we recommend reading section 11 of BS 5839 9:2011 which deals with Outstation Types and states as follows: Benefits Can be used on all EVCS systems Full duplex operation, allowing 2 way voice communication Tactile braille signage to assist partially sighted people enabling them to easily operate the refuge point 11.1.a An outstation intended for evacuation or firefighting use should be Type A. A Type B outstation should be used for such purposes only where it is impractical to install a Type A outstation. 11.1.b An outstation intended for use by disabled people at refuges may be either Type A or Type B. However, Type B outstations should be used in situations where the outstation will be operated by members of the public. EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) 07

EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) Emergency Assist Alarm Range The Emergency Assist Alarm Kit has been specifically designed to integrate disabled call functions into the EVCS network or EVCS compact ranges. Key Features Monitored to BS 5839 9 Remote powered from EVCS exchange Dual loop pull cord High contrast labels Braille on cancel button Blue indication Benefits Saving power, no PSU is required remote powered by EVCS system One install saves running 2 separate systems Calls from either disabled toilets or refuge points are monitored from one central location Tactile braille signage to assist partially sighted people to easily operate the cancel button It has now become very common for the disabled toilet to be specified as part of the refuge system. Disabled toilet alarms are required by Building Regulation Document M, and by integrating it with the Emergency Voice Communication System all calls relating to disabled communications can be displayed in a single point. The Emergency Assist Alarm Kit solution is fully monitored and battery backed by the EVCS system, saving local power supplies and giving confidence in the system integrity. The Emergency Assist Alarm Kit shows up as a call on the EVCS system, but has no speech path so a conversation cannot be had with the occupant, use of the Type B Outstations would allow this. TYPICAL System Architecture Power Supply Pull Cord Unit - + 12V - + - + - + IN OUT Over Door Indicator - + - + IN OUT Cancel Unit 08

4 Way Splitter Unit The 4 Way Splitter Unit allows up to 4 stand alone disabled toilets to be monitored in one specific area. Key Features Designed to comply with all regulations and recommendations High visibility More than one 4 way splitter can be used Small compact design Benefits Up to 4 disabled toilets monitored in one area Uses blue LEDs to avoid confusion Extend your Emergency Assist Alarm Stand Alone Unit by adding a 4 Way Splitter Unit. Staff can then, at a designated area, such as a reception or security desk monitor and react to an alarm in four separate disabled toilets swiftly and efficiently, from one easy to use and space saving device. Typical emergency alarm assist system using a 4 way splitter Visibility to remote staffed areas No mains or Power Supply Unit (PSU) required at each disabled toilet EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) 09

EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) Notes 010

Notes EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS) 011

Honeywell Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Email: hlsuksalessupport@honeywell.com 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN