CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

Similar documents
CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

Flomate Mains Boost Pump Installation & Maintenance Instructions

Installation Instructions For Monsoon Extra Pressure Sets:

Installation Instructions For Showermate Eco Shower Booster Pumps S1.5 bar Twin, S2.0 bar Twin, S2.0 bar Single

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation Instructions For Monsoon Universal Twin Pump

Installation Instructions For Monsoon Universal Twin Pump

Installation Instructions For Monsoon Extra Universal Single Duty Pump

Installation, Operation & Maintenance Instructions

WC2 & WC3 Installation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

Mira 1.5 bar Twin Ended Pump Mira 2.0 bar Twin Ended Pump

NON-SUBMERSIBLE WATER PUMP

HEAVY DUTY BRASS SHOWER PUMPS

V80-H Multistage Pump Instruction Manual

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

PERFORMANCE SHOWER PRODUCTS

SHOWER PUMP. Installation and User Guide. These instructions are to be left with the user

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE WATER PUMPS

Multipoint. Installation and User Instructions Instantaneous Hand Wash Models: EV 2008

Tempest TP420/180 Electric Pressure Washer

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

PANTHER. Condensate removal pump Installation and operating guide

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

SHOWER PUMP. Installation and User Guide. These instructions are to be left with the user 1

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

2400W steam generator with one touch temperature control. Instruction Manual MODEL: SI9020TTN

VADA - Rain2Main Automatic Rainwater Controller

Safety and Instruction Manual

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

T550i power shower pump Installation and operating instructions

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Heavy Duty Pressure Washer 150

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Installation and Wiring Instructions

This label warns for risk of electrical shock when failing to observe.

2 IN 1 JUICER AND BLENDER

PERFORMANCE SLIMMING BELT

6000, 8000, & 15000

INSTANTANEOUS ELECTRIC SHOWER

Whole Room Dryer WRD, WRD/110

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Hand Dryer Installation & User Manual

DUST EXTRACTOR MODEL No: CDE1000

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

The Professional s Choice

High Pressure Washer 130

Turboboost SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Compact Pressure Washer 100

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

User Instruction Manual

HW3 Handwash Installation and Operating Instructions

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

air conditioner/dehumidifier 9000btu/hr

POWER SHOWERS Models 4500M 5002M 4500T 5002T

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

identity installation & maintenance instructions customer/technical services guarantee

LC Series - Light Commercial Pump Station Installation and Operation Manual

EASYCLEAR 3000 YEAR GUARANTEE

Model No: Little Devil II (inc ss)

Unvented Electric Water Heater 10/15 litre Undersink

HIT Centrifugal In-Line Fan

Installation and User Instructions Instantaneous Hand Wash Models: EV 2008 No-Touch. EV 2008 No Touch

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide


AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Bath Shower Mixer

UV Biological Pond Filter. Inlet /Outlet Size

HOT WASHER MODEL NO: KING150

Installation, Operating and Servicing Instructions

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Transcription:

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions)

MODELS Kennet K7-2 Kennet K9-2 Kennet K12-2 Thame T6-2 Thame T12-2 Loddon L5-4S Loddon L7-4S X201 INDEX................. Page No Application......................... 2 Product Description.................. 3 Limits of Application.................. 3 Technical Specifi cation............... 4 Connections....................... 5 Siting of the Pump/Pipework........... 6 Electrical Installation................. 8 IMPORTANT NOTES - 2 - INDEX................. Page No Noise............................. 13 Commissioning..................... 13 Maintenance....................... 15 Trouble Shooting Guide............... 16 Performance Information.............. 17 Environment Protection............... 17 Please read these instructions fully before starting the installation: The installation must comply with the relevant water supply, electrical and building regulations and be installed by a competent person. If in doubt, consult Stuart Turner Ltd. APPLICATION The range of centrifugal pumps is designed to pump clean fresh water. Other clean, non aggressive, non explosive liquids with similar characteristics to water may be pumped. Consult Stuart Turner for advice on such applications. The pumps can be used for pressure boosting, fluid transfer and distribution. They are suitable for flooded suction applications. Alternatively a maximum suction lift of 4.6 metres is permitted when using a Stuart footvalve/strainer. The X201 pump is a self priming pump. Suction lifts up to 6 metres are possible, with or without a footvalve/strainer, once the pump is primed. WARNING AGAINST MISUSE This pump set must not be used for any other application without the written consent of Stuart Turner Limited. In particular, it must not be connected directly to the mains water supply, or used outside the conditions specified in the limits of application. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

PRODUCT DESCRIPTION Motor: Induction type, totally enclosed fan ventilated cooling, continuously rated, class F insulation. Motors comply with BS 5000 or IEC 34-1. Single phase versions incorporate a permanent capacitor and integral auto resetting thermal overload protection. Enclosure ratings are given in the technical specification section. The standard range of motors are suitable for a supply of 230V, 1 phase, 50Hz. Optional motors are available on certain models to suit various voltages and frequencies (see technical specification for details). Pump: Close coupled, end suction configuration and of centrifugal design. The number of pump stages are given in the technical specification section. Standard pump materials of construction of major wetted parts are as follows: - Model Body Impeller Shaft Mechanical Seal Kennet Range Thame Range Loddon Brass Noryl Stainless Steel Noryl Stainless Steel Acetal or Brass Polycarbonate Polycarbonate Stainless Steel Stainless Steel Stainless Steel X201 Noryl Glass filled Nylon Brass (Sleeved) Other seal material options are available on certain models. Nitrile/Carbon/Silicon Carbide/Stainless Steel Nitrile/Carbon/Silicon Carbide/Stainless Steel Nitrile/Carbon/Silicon Carbide/Stainless Steel Nitrile/Carbon Ceramic/Stainless Stee LIMITS OF APPLICATION Model Supply Impeller Material Max. Liquid Temp. o C Min. Liquid Temp. o C Max. Ambient Air Temp o C Max. Suction Lift (m) Max. Head (Pump Closed Valve) (m) Max. Viscosity (Redwood No. 1 Scale) Centistokes **Max. Working Pressure kpa (bar) Max. Inlet Head (m) Max. No. Starts/h K7-2 230/1/50 Plastic 80 4 40 4.6* 9.2 50 9.5 600 (6) 51 60 K9-2 230/1/50 Plastic 80 4 40 4.6* 8.9 50 9.5 600 (6) 51 60 K9-2 230/1/50 Brass 80 4 40 4.6* 9.2 50 9.5 600 (6) 51 60 K9-2 400/3/50 Plastic 80 4 40 4.6* 9 50 9.5 600 (6) 51 60 K12-2 230/1/50 Plastic 80 4 40 4.6* 13.9 50 9.5 600 (6) 51 60 K12-2 230/1/50 Brass 80 4 40 4.6* 14.7 50 9.5 600 (6) 51 60 K12-2 400/3/50 Plastic 80 4 40 4.6* 14 50 9.5 600 (6) 45 60 T6-2 230/1/50 Plastic 65 4 40 4.6* 30 50 9.5 400 (4) 10 60 T12-2 230/1/50 Plastic 65 4 40 4.6* 32 50 9.5 400 (4) 7 60 L5-4S 230/1/50 Plastic 65 4 40 4.6* 47.5 50 9.5 700 (7) 27 60 L7-4S 230/1/50 Plastic 65 4 40 4.6* 49.5 50 9.5 700 (7) 23 60 X201 230/1/50 Plastic 50 4 40 6 19 50 9.5 300 (3) 11 60 * With footvalve fitted. **Note: Max working pressure is the maximum pressure that can be applied to the pump internal casing under any installation conditions. - 3 -

TECHNICAL SPECIFICATION Model Supply Impeller Material Nominal Watts Output (Motor) Max. Watts consumed at full flow Full Load (AMPS) Enc. Rating Dims (mm) L W H Gross Weight (packed) kg No. of Pump Stages K7-2 230/1/50 Plastic 180 230 1 IP44 237 131 180 6.1 1 K9-2 230/1/50 Plastic 250 330 1.5 IP44 242 131 180 6.3 1 K9-2 230/1/50 Brass 250 350 1.6 IP44 242 131 180 6.3 1 K9-2 400/3/50 Plastic 250 370 0.85 IP44 288 133 166.5 6.3 1 K12-2 230/1/50 Plastic 500 595 2.8 IP44 277 131 180 8.2 1 K12-2 230/1/50 Brass 500 635 2.9 IP44 277 131 180 8.2 1 K12-2 400/3/50 Plastic 500 610 1.1 IP44 288 133 166.5 6.3 1 T6-2 230/1/50 Plastic 650 890 3.9 IP55 326 210 214 8.2 2 T12-2 230/1/50 Plastic 820 1140 5.2 IP55 350 210 214 9.4 2 L5-4S 230/1/50 Plastic 600 925 4.1 IP55 400 202 214 9.8 4 L7-4S 230/1/50 Plastic 760 1075 4.9 IP55 424 202 214 10.8 4 X201 230/1/50 Plastic 670 930 4.1 IP55 375 205 255 9.6 1 Stuart Turner reserve the right to amend the specification in line with its policy of continuous development of its products. Note: For information on other voltages/frequencies which are not shown, consult any supplementary instruction sheet supplied, or the rating label attached to the pump. - 4 -

CONNECTIONS Pump Type Voltage Inlet Outlet Fig. No K7-2 230/1/50 G1 Female G1 Female 1 K9-2 230/1/50 G1 Female G1 Female 1 K9-2 400/3/50 G1 Female G1 Female 2 K12-2 230/1/50 G1 Female G1 Female 1 K12-2 400/3/50 G1 Female G1 Female 2 T6-2 230/1/50 G1 Female G1 Female 3 T12-2 230/1/50 G1 Female G1 Female 3 L5-4S 230/1/50 G 1¼ Female G1 Female 5 L7-4S 230/1/50 G 1¼ Female G1 Female 5 X201 230/1/50 G 1¼ Female G 1¼ Female 4 OUTLET OUTLET PRIMING PLUG PRIMING PLUG INLET INLET Fig. 1 Fig. 2 OUTLET OUTLET PRIMING PLUG PRIMING PLUG TURNER LTD INLET TURNER LTD INLET Fig. 3 Fig. 4 PRIMING PLUG OUTLET INLET TURNER LTD Fig. 5-5 -

SITING OF THE PUMP/PIPEWORK WARNINGS: Pump Location If possible site the pump in a location where in the unlikely event of a liquid leak, any spillage is contained or routed to avoid electrics or areas sensitive to liquid damage. Ensure pipework to and from pump is independently supported to prevent stress on the pump inlet and outlet branches. Do not fit a non-return valve, or devices which contain non-return valves, in the suction (inlet) pipework to the pump. Exceptions can be made in the case of suction lift installations when a footvalve is required. When a footvalve is required on installations that incorporate automatic pump control, it is recommended that a suitable pressure relief valve be fitted in the discharge (outlet) pipework from the pump. Do not run against a closed valve for periods longer than 5 minutes. Do not allow plastic pump parts to come into contact with oil or cellulose based paints, paint thinners or strippers, acid based descalents or aggressive cleaning agents. Do not introduce solder flux to pumps or pump parts manufactured from plastic. All solder joints should be completed and flux residues removed prior to pump connection. Care should be taken to protect the pump from frost and freezing. Always install isolating valves to both suction and delivery pipework. The motor casing can become very hot under normal operating conditions. Care should be taken to ensure it cannot be touched during operation. Site the pump horizontally in a dry, frost-free position where it cannot be sprayed with water and as close to the liquid source as possible. The pump enclosure must be ventilated and there should be a minimum clearance of 80 mm between the pump and housing on all sides. To prevent loss of pressure through pipework, use pipe size to match pump whenever possible, minimising 90 bends. It must be ensured that storage capacity of the liquid supply is adequate for the flow rates required by the pump. The pipework feeds to the storage tank should be of adequate size to ensure replenishment rate of tank is sufficient to meet the needs of the pump. Isolating valves should be fitted in suction and delivery pipework to enable easy isolation and access to the pump. When the pump is to be installed in areas where there is a risk of debris or scale build up within the system, it is recommended that the inlet pipework is fitted with an inline strainer. - 6 -

Mounting Foot Securing Some pumps within the range are fitted with plastic mounting feet. If there is a requirement to secure the pump via the mounting feet, the following points should be noted. The pump should be mounted only in the horizontal position. Floor mounting is the preferred orientation but wall mounting is possible providing all fixing holes provided are used. *Air locking possible. Special care required to vent the pump casing of air with this orientation. Fig. 6 The mounting bolts used to secure the pump must be fitted with a plain washer to distribute clamping load evenly across load bearing face of foot. PLAIN WASHER MOUNTING FOOT Fig. 7 BOLT Pump Mounted Above Liquid Source (Suction Lift) The pumps can be used in a suction lift installation providing the height of lift is within the limits specified in the limits of application section (Fig. 8). A footvalve and strainer must always be used (except X201 when used on a self priming installation) and the suction pipework size must match the pump. Lay the suction piping over the shortest possible distance and ensure there is a constant rise from the liquid source to the pump. Any high spots will cause air pockets to form, reducing system efficiency. Ensure all joints in suction pipework are completely airtight. Failure to comply will result in loss of prime. The intake of the footvalve/strainer should be positioned such that it cannot be blocked with debris or silt that are frequently found in the bottom of sumps and wells. When a footvalve is installed on installations that incorporate automatic pump control, it is recommended that a suitable pressure relief valve be fitted in the discharge (outlet) pipework from the pump. Max suction lift (m) (see Limits of Application Section) Fig. 8-7 - Suction lift installation with footvalve and strainer

ELECTRICAL INSTALLATION WARNINGS: The electrical installation must be carried out in accordance with the current national electrical regulations and installed by a competent person. Before starting work on the electrical installation ensure the power supply is isolated. Where any of the pumps are installed in an area where there is a risk of water spillage and particularly in the case of the X201, it is recommended that a residual current circuit breaker having a rated current not exceeding 30 ma, be installed in the supply circuit. This may be part of a consumer unit or a separate unit. This appliance must be earthed. The motor and wiring must not be exposed to water. Do not allow the supply cord to contact hot surfaces, including the motor shell, pump body or pipework. The cord should be safely routed and secured by cable clips. The standard single phase pumps are suitable for a supply of 230V, 1 Phase, 50Hz. Other voltages and frequencies are available on certain models and it is therefore very important to ensure the voltage and frequency on the pump rating plate matches the supply. When installing a 230V, 1 phase, pump in the United Kingdom, means for disconnection must be incorporated in the fixed wiring according to the Wiring Rules. This can be done by permanently connecting the pump to the mains supply via a double pole switched, fused connection unit complying with BS 1363-4. The standard three phase pumps are suitable for a supply of 400V, 3 Phase, 50Hz and should be connected via a starter complete with suitably sized thermal overload. All motors exceeding 370 watt output should be provided with control equipment incorporating means for protection against overload. The spur box (fused connection unit) or starter to which the pump is connected should be mounted in an easily accessible position and labelled if confusion is possible to allow easy isolation of the unit. All pumps are continuously rated. Earthing This appliance must be earthed via the supply cord, which must be correctly connected to the earth point located in the terminal box. Copper or metallic pipework must have supplementary earth bonding where the continuity has been broken by flexible hoses or plastic components. Adjacent suction and delivery pipes should be fitted with earthing clamps to BS 951 and connected with earthing wire size 4 mm² (see Fig. 9). - 8 -

Diagram of earth continuity connection. Certain installations may require additional earthing arrangements such as equipotential bonding. Reference should be made to the relevant regulations concerning this subject to ensure compliance. Wiring (Kennet range) This product range must be permanently connected to fixed wiring and is provided with a set of terminals which allow the connection of a flexible supply cord. Select a cord and fuse size based on the motor full load current and the surrounding conditions. For information on cable fitting and connection, consult the wiring diagram and cable gland and supply cord fitting instructions. WARNING: This appliance must be earthed. Fig. 9 Wiring (Thame, Loddon and X201 range) This product range is supplied with a factory fitted mains lead (supply cord). This must be permanently connected to the fixed wiring. The wiring in the mains lead are coloured in accordance with the following code: Green and Yellow: Earth. Blue: Neutral. Brown: Live. As the colours of the core in the new mains lead may not correspond with the coloured markings identifying the terminals in your connection unit, proceed as follows: Green and yellow coloured wire must be connected to the terminal marked with the letter E or by the earth symbol or coloured green or green and yellow. Blue coloured wire must be connected to the terminal marked with the letter N or coloured black. Brown coloured wire must be connected to the terminal marked with the letter L or coloured red. WARNING: This appliance must be earthed. Supply Cord Replacement (Thame, Loddon and X201 range) If the supply cord is to be changed or is damaged, it must be replaced with a special cord assembly available from Stuart Turner or one of their approved repairers. On disassembly note the cord retention and routing system. Re-assemble to the same pattern. For information on cable connection consult the wiring diagram. - 9 -

Supply Cord Extension (Thame, Loddon and X201 range) If the supply cord of the pump needs to be extended use the same specification as fitted to the product. Thame, Loddon and X201 range:-........ HO7RN-F3 G 1 mm², 10 Amp rating. Use an appropriate cable connector suitable for the cable specified, current involved and surrounding conditions. Fuses The following table gives the recommended fuse size for pump models fitted with a power cord at the factory. Model Fuse Size (AMPS) Thame 13 Loddon 13 X201 13 For all models not listed, the power cord must be sourced and supplied by the installer. Cable selection and fuse size should be based on the motor full load current and the surrounding conditions. - 10 -

Cable Gland & Supply Cord Fitting Instructions (Kennet single phase range) The cable gland assembly Fig. 12 (items 1 & 2) provides the necessary protection against ingress of solid objects and moisture as well as providing cable retention. Assembly instructions are as follows: - 1. Ensure selected cable sheath diameter is within the permitted range (6.5 to 9.5 mm). 2. Strip and prepare the cable sheath and insulators as shown in Fig. 10. 3. Disassemble cable gland as shown in Fig. 12 and insert cable into position ensuring O -ring (item 2) is placed over the cable before the clamping insert (item 1) is tightened. 4. Consolidate the stranded conductor ends by twisting and shape the earth conductor as shown in Fig. 11 (item 3). 5. Remove earth terminal post clamping components and assemble as shown in Fig. 11 ensuring shaped conductor is orientated as shown and all strands of the conductor are clamped between the washers. 6. Insert and secure live and neutral conductors ensuring all conductor strands are clamped. 7. Confirm cable routing is as shown in Fig. 12 and assemble and secure terminal box lid. E 12 N L 8 8 110 70 70 (Dims. in mm) 3 Fig. 11 Fig. 10 2 1 Fig. 12-11 -

Cable Gland & Supply Cord Fitting Instructions (Kennet three phase range) The cable gland assembly Fig. 15, (items 1 & 2) provides the necessary protection against ingress of solid objects and moisture as well as providing cable retention. Assembly instructions are as follows:- 1. Ensure selected cable sheath diameter is within the permitted range (7.5 to 9.5 mm). 2. Strip and prepare the cable sheath and insulators as shown in Fig. 13. 3. Disassemble cable gland as shown in Fig. 15 and insert cable into position ensuring O -ring (item 2) is placed over the cable before the clamping insert (item 1) is tightened. 4. Consolidate the stranded conductor ends by twisting and shape the earth conductor as shown in Fig. 14 (item 3). 5. Route the cable as shown in Fig. 15. 6. Remove earth terminal post clamping components and assemble as shown in Fig. 14 ensuring shaped conductor is orientated as shown and all strands of the conductor are clamped between the washers. 7. Insert and secure the three off phase conductors ensuring all conductor strands are clamped. 8. Confirm cable routing is as shown in Fig. 15 and assemble and secure terminal box lid. E 12 L1 L2 L3 8 8 110 80 70 3 (Dims. in mm) Fig. 14 Fig. 13 1 2 Fig. 15-12 -

Wiring Diagrams The supply cord and internal wiring within the terminal box are routed and secured to ensure compliance with the electrical standard EN 60335-1. It is essential that any disturbance of this internal wiring is avoided and the factory routing and securing of all internal wiring is always maintained. CAPACITOR BLUE BROWN BROWN LINK WIRE (BLUE) MAIN WINDING BLUE THERMOTRIP START WINDING BLACK CAPACITOR Fig. 17 E GREEN/YELLOW BLACK BLACK THAME, LODDON & X201 RANGE 230V, 1 phase, 50Hz supply BROWN WHITE BLUE MOTOR BROWN BLUE GREEN/YELLOW YELLOW BLUE RED BROWN WHITE BLACK L N E 230 VAC/1PH/50Hz SUPPLY Fig. 16 KENNET K7-2, K9-2 & K12-2 RANGE 230V, 1 phase, 50Hz supply TO REVERSE ROTATION INTERCHANGE ANY TWO SUPPLY LEADS W V U GREEN/YELLOW L1 L2 L3 E NOISE The equivalent continuous A-weighted sound pressure level from the pumpset does not exceed 70 db(a) at a distance of one metre. COMMISSIONING WARNINGS: Fig. 18 The motor casing can become very hot under normal operating conditions, care should be taken to ensure it cannot be touched during operation. Do not run pump without guards and terminal box lid correctly fitted. The pump chamber must be full of liquid at all times. Seal damage will result if the pump runs dry. - 13 - KENNET K9-2 & K12-2 400V,3 phase, 50Hz supply

1. System Flushing Some pumps incorporate plastic components that must not come into contact with solder flux, acid-based descalents or aggressive cleaning agents. The pipework system should be flushed out prior to the pump being connected, to ensure any contaminants/chemical residues and foreign bodies are removed from elsewhere in the system. 2. Liquid Supply Always ensure that liquid storage capacity is adequate to meet the demand. Ensure the pump chamber is full of liquid before starting the pump. Failure to do this could result in seal damage. To ensure dry running does not occur the pumps must be primed as described in the priming section. Do not run pump dry. 3. Ensure electrical supply is compatible with the details that are stated on the pump rating plate. (The wrong voltage or frequency can be dangerous and may damage the pump.) 4. Priming a) Flooded suction installation. The pump must be primed (filled with liquid) before starting. Turn on liquid supply, prime and vent the pump by unscrewing the priming plug (Fig. 19) slowly until all air escapes and liquid emerges. Re-tighten plug. b) Suction lift installation. Prime the suction pipework and pump by filling with liquid via the pump discharge connection or by filling the suction pipework before attaching to the pump. c) X201 only (suction lift installation) This pump is capable of priming the suction hose with liquid on installation. Ensure both suction and delivery hose connections are air tight. Remove the yellow priming plug located on the top of the pump housing. Fill the pump body with liquid slowly allowing the air to escape. Fully submerge suction hose in liquid source. When all is satisfactory the electrical supply can be switched on, (whilst the pump is priming, the delivery must be open). If nothing happens after 5 minutes, switch the pump off, re-prime the pump again. Note: The amount of time taken for priming and the number of times priming is required will vary dependant on height of suction lift. The suction pipe can also be fitted with a footvalve and strainer which will ensure the pump and pipework remains primed at all times. The suction hose should not exceed 32 mm dia bore. - 14 -

Fig. 19 Priming Plug Priming Plug Priming Plug Kennet 230/1/50 Kennet 400/3/50 Thame Loddon X201 5. Starting a) Switch on power to the pump which will now be operational. b) If pump has a three phase supply, confirm the direction of rotation is correct by stopping and observing over run. The correct direction of rotation is anti-clockwise when looking directly at the front of the pump casing. To reverse rotation see wiring diagram section. c) The pump should now be fully operational. d) Carefully check pump and pipework for leaks whilst pump running and stationary before leaving the installation unattended. For Further Technical Support Phone the Stuart Turner Pump Assist team on 0844 98 000 97. Our staff are trained to help and advise you over the phone or arrange for a service engineer to call. Note: When pumps are installed in another manufacturers original equipment, please contact the manufacturer for advice. MAINTENANCE WARNINGS: Care should be taken to protect the pump from frost and freezing. Pump Location If possible site the pump in a location where in the unlikely event of a liquid leak, any spillage is contained or routed to avoid electrics or areas sensitive to water damage. 1. No routine maintenance is required but provision should be made for easy access to the pump to allow for repairs due to normal wear and tear. 2. Disconnect electrical supply before working on pump. 3. Turn off liquid supplies to the pump and release pressure by opening outlets before attempting maintenance. 4. If the installation is fitted with a footvalve and strainer or inline suction strainer, the strainer must be cleaned as necessary to ensure the pump has unrestricted flow. 5. After maintenance is completed, refer to commissioning section for instructions on restarting pump. - 15 -

Cleaners, Disinfectants and Descalents On installations where chemical disinfectants or descalents are periodically used, the compatibility of the chemical solution regarding the pump must be considered. Acid based descalents and aggressive cleaning agents must not come into contact with the pump. The pump must be removed from the system prior to the use of these products. The system should be flushed to remove all chemicals before the pump is re-connected. If in any doubt as to the suitability of the chemical solutions refer to Stuart Turner Ltd. STORAGE If this product is not installed immediately on receipt, store in a dry, frost and vibration free location in its original packaging. TROUBLE SHOOTING GUIDE Symptoms Probable Cause Recommended Action Pump will not start. Electrical supply. Check power to motor. Check the circuit breaker is set. Check the correct fuse is being used. Pump runs, but no liquid is pumped. Internal motor thermotrip activated. Air locked. No liquid supply. Motor running backwards. Connections reversed. Wait for thermotrip to cool and auto-reset. Investigate cause of problem. Bleed pipework and pump to clear air. Check the supply valves are turned on. Check outlet not restricted or blocked. 3 phase only - check motor is rotating in the correct direction, if not, reverse connections of any two incoming supply wires. Check liquid connections are on the right way round. No flooded suction. Check the pump has a flooded suction and is primed. No footvalves. If a suction lift exists and pump is not X201 self prime model, fit a Stuart footvalve/strainer and ensure suction pipework is airtight. - 16 -

PERFORMANCE INFORMATION Performance curves are based on liquids having the same specific gravity and viscosity as clean water at 20 C. 16 50 HEAD (metres) 14 12 10 8 6 4 2 0 0 20 40 60 80 100 120 140 160 180 200 220 K9-2 K12-2 FLOW (l/min) K7-2 Fig. 20 Fig. 21 Kennet Range HEAD (metres) 40 30 20 10 L5-4S L7-4S 0 0 20 40 60 80 100 120 FLOW (l/min) Loddon Range HEAD (metres) 35 30 25 20 15 10 5 T6-2 T12-2 0 0 50 100 150 200 250 FLOW (l/min) Fig. 22 Fig. 23 Thame Range HEAD (metres) 20 18 16 14 12 10 8 6 4 2 0 0 6m 4m 2m 1m 0m SUCTION LIFT 20 40 60 80 100 120 140 160 180 200 220 FLOW (l/min) X201 NOTE: The performance curves shown above are for standard 230, 1 phase, 50Hz models. Other variants using different voltages or frequencies may vary from above performance. For further details contact Stuart Turner. ENVIRONMENT PROTECTION Your appliance contains valuable materials which can be recovered or recycled. At the end of the products useful life, please leave it at an appropriate local civic waste collection point. - 17 -

NOTES - 18 -

NOTES - 19 -

DECLARATION OF CONFORMITY 2006/42/EC BS EN ISO 12100-1, BS EN ISO 12100-2, BS EN 809 2006/95/EC BS EN 60335-1, BS EN 60335-2-41, EN 50366 2004/108/EC BS EN 55014-1, BS EN 55014-2, BS EN 55022, BS EN 61000-3-2, BS EN 61000-3-3, BS EN 61000-4-2, BS EN 61000-4-3, BS EN 61000-4-4, BS EN 61000-4-5, BS EN 61000-4-6, BS EN 61000-4-11 IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW, COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E.E.C. DIRECTIVES. RESPONSIBLE PERSON AND MANUFACTURER STUART TURNER LIMITED HENLEY-ON-THAMES, OXFORDSHIRE RG9 2AD ENGLAND. Signed......................................... Customer Relationship Manager Stuart Turner are an approved company to BS EN ISO 9001:2000 YOUR 1 YEAR GUARANTEE Stuart Pumps are guaranteed by Stuart Turner Limited to be free from defects in materials or workmanship for the applicable guarantee period from the date of purchase. The applicable guarantee period is stated in the installation booklet supplied with the pump. Within the guarantee period we will repair, free of charge, any defects in the pump resulting from faults in material or workmanship, repairing, exchanging parts or exchanging the whole unit as we may reasonably decide. Not covered by this guarantee: Damage arising from incorrect installation, improper use, unauthorised repair, normal wear and tear and defects which have a negligible effect on the value or operation of the pump. Reasonable evidence must be supplied that the pump has been purchased within the applicable guarantee period prior to the date of claim (such as proof of purchase or the pump serial number). This guarantee is in addition to your statutory rights as a consumer. If you are in any doubt as to these rights, please contact your local Trading Standards Department or Citizen s Advice Bureau. In the event of a claim please telephone Stuart Turner Limited on 0844 980 0097 or return your pump and flexible hoses with accessories removed, plugs, pipes etc. If you have any doubt about removing a pump, please consult a professional. Proof of purchase should accompany the returned pump to avoid delay in investigation and dealing with your claim. Stuart Turner Ltd, Henley-on-Thames, Oxfordshire RG9 2AD ENGLAND Tel: +44 (0) 1491 572655, Fax: +44 (0) 1491 573704 email: pumps@stuart-turner.co.uk web: www.stuart-turner.co.uk V.A.T. REG. No. 199 0987 92. Registered in England No. 88368. Registered Offi ce: Market Place, Henley-on-Thames Issue No. 5010/1-02 Pt. No. 19330