Write Walls Dry Erase Specification Data (Section 09720)

Similar documents
SECTION PRESENTATION DRY ERASE WALLCOVERING

SECTION PRESENTATION DRY ERASE WALLCOVERING

SECTION PRESENTATION DRY ERASE WALLCOVERING

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

c. Oko-Tex (European environmental health standard)

ARCHITECT S SPECIFICATIONS For Commercial Vinyl Wallcoverings

EXAMPLE SPECIFICATION ONLY

ARBOR SERIES WOOD WALLCOVERINGS

ARCHITECT S SPECIFICATIONS

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

SECTION (09950) - WALL COVERINGS

WALLCOVERINGS WALLCOVERINGS

Non Woven Wallcoverings with or without Crystals Installation and Maintenance Guidelines

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

venetian plaster exclusivewallcovering Low VOC LEED IEQ 4.2 CAL 1350 & CHPS certified VINYL WALLCOVERING Fire classification

mason What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Laurel Forest Punta Grasscloth

INSTALLATION INSTRUCTIONS FOR VINYL WALLCOVERING

Kalos Cameo Wallpaper

TYPE II WALLCOVERING. Gradient: Specify reverse hang, non-reverse hang or railroaded, 52" (132 cm) horizontal repeat, random match

Banda Cay Wallpaper. eskayel.com T South 6th Street Brooklyn, NY 11249

MagScapes Product Guide

Madagascar Sky Blue Wallpaper

Porta Mural Wallpaper

UNIFIED FACILITIES GUIDE SPECIFICATIONS

HP PVC-free Durable Wall Paper

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

Wallpaper Buying Guide

16028 September 23, 2016

DIVISION 10 SPECIALTIES

Jot a wall. jot on 50 ss. jot on 50 ss features. Versatile dry erase product. Versatile dry erase product.

INSTALLATION INSTRUCTIONS FOR. ProTek RIGID VINYL WALLCOVERING

SECTION FIRE EXTINGUISHER CABINETS

LEVEYINDUSTRIES.COM

Introduction The following illustrated instructions are a generic guide to the internal installation of Safety and Security Films.

Technical Data Sheet. Non-Woven Base: Product Information. Manufacturer. Product Name. Product Specifications

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Wallcovering. Index Wide

Smarter Surfaces Product. Catalogue. website

MICROVENTING AVAILABLE This product can be microvented with the Duravent process for breathability. You may specify this as an added feature.

PRODUCT INFORMATION FOR CHARLES RUPERT DESIGNS WALLPAPERS October 2007

Enhancing Learning with World Class MarkerBoards, ChalkBoards, and TackBoards /ABC BuyLine 1844

A. Shop Drawing submittals shall include, but not be limited to, the following:

Electric Can Opener USER GUIDE

A. Product Data: Manufacturer s product data sheets for all specified curtain track and curtains.

Wallpaper Hanging Instructions

A. Curtains: Provide curtain fabrics with the following characteristics:

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

***************************************************************************************************************

Instructions for Coating Fimbel Garage Door Panels

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION TABLE OF CONTENTS GEOTEXTILE TUBES PARAGRAPH TITLE PAGE NOS.

SECTION CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL

Product instruction manual Easymount Wide Format Laminators

Section Specification for Geotextile Used in Permanent Erosion Control Application

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Instructions for Coating Cellular PVC Solid Color (brushing and spraying)

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic

TCC 2700 Laminating Machine Operating Instructions

SECTION AIR DUCT ACCESSORIES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

PART 1 GENERAL 1.01 SUMMARY

Everase. Your Full Whiteboard Solution Provider

Timber Venetians Manual

Section Plaster Accessories

SPECIAL SPECIFICATION 3687 Impermeable Liner

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

SECTION THEATER CURTAINS AND TRACKS. A. American Society for Testing and Materials (ASTM):

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

SOLI VINYL. Type II. Photo: Wallcovering Soli ACW Tequila Sunrise #14

INSTALLATION. Glass Panel Doors (select models) CAUTION

DRAPERY STYLES ACCORDIAFOLD

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

Architectural Specification Sheet

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION FIRE-RATED GLASS AND FRAME

IdealFILM. Do-It-Yourself Installation Manual

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY STANDARD SPECIFICATION. Section SODDING

A. Section Masonry Assemblies: Anchor placement in masonry.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

CARING FOR YOUR ATRIUM WINDOWS AND DOORS

ARCHITECTURAL SPECIFICATIONS

IT S OK TO SHARE. Visit us at walltalkers.com

ST-1 Surface Treatment

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

Caring For Your Atrium Windows and Doors

1501 Westpark Drive, Suite 5 Little Rock, Arkansas International

Transcription:

Write Walls Dry Erase Specification Data (Section 09720) Section 1 Part 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry Erase Wallcovering 2. Accessories B. Related Sections / Items 1. Section 09250 Gypsum Board: Wall substrates 2. Section 09900 Painting: Preparation and priming of substrate surfaces. 3. Section 09720 Wallcovering 1.2 REFERENCES A. American Society for Testing and Materials (ASTM) 1. E 84-01 Test method for surface burning characteristics of building materials. B. Gypsum Association 1. GA-14-M-97 Recommended levels of gypsum board. 1.3 SUBMITTALS A. Manufacturer s product data and installation instructions for dry erase wallcovering, adhesive, and accessories required. B. Manufacturer s written product data indicating compliance with specified materials required. C. Manufacturer s written installation instructions. D. Manufacturer s written instructions for recommended maintenance of dry erase wallcovering required. E. Samples: 1. 7 x 9 samples of each dry erase material required. 2. Samples of trim and tray required.

1.4 QUALITY ASSURANCE A. Manufacturer: Write Walls Dry Erase Wallcovering B. Applicator: Installation by skilled commercial wallcovering applicators with no less than three years of documented experience installing dry erase wallcovering required. C. Composition: 1. Write Walls Dry Erase Wallcovering: Provide woven, fabric backed, pigmented vinyl laminated with a dry erase clear film. D. Fire Hazard Classification: Provide materials that comply with Class A fire rating when tested in accordance with ASTM E84-01. Identify components with markings from testing and inspection organization. E. Field Samples: Prepare field samples for architect s review and to establish requirements for seaming and finish trim. 1. Install sample panel of dry erase wallcovering specified in area designated by architect. 2. Maintain corrected and approved samples to serve as a standard of performance for the project. 1.5 PRODUCT DELIVERY, STORAGE AND HANDLING A. Deliver dry erase wallcovering to the project site in unbroken and undamaged original factory wrappings and clearly labeled with the manufacturer s identification label and lot number. B. Store materials in a clean, dry storage area with temperature maintained above 55 degrees F with normal humidity. C. Store material in a flat position to prevent damage to roll ends. Do not cross stock material. Support material off the floor in a manner to prevent sagging, warping and creasing. 1.6 PROJECT CONDITIONS A. Do not apply dry erase wallcoverings when surface and ambient temperatures B. Provide continuous ventilation and heating facilities to maintain substrate surface and ambient temperatures above 55 degree F unless required otherwise by manufacturer s instructions. C. Apply adhesive when substrate surface temperature and ambient temperature is above 55 degrees F and relative humidity is below 40 percent.

D. Maintain constant recommended temperature and humidity for at least 72 hours prior to and throughout the installation period, and for 72 hours after wallcovering installation completion. E. Provide not less than 80 foot-candles per square foot lighting level minimum measurement and height at substrate surfaces. 1.7 WARRANTY A. Submit manufacturer s limited ten-year written warranty against manufacturing defects. 1.8 MAINTENANCE A. Maintenance instructions: Include precautions against cleaning materials and methods that may be detrimental to finishes and performance. Part 2 PRODUCTS 2.1 MANUFACTURERS A. Wallcoverings: Write Walls Dry Erase Wallcovering 2.2 MATERIALS A. Write Walls Dry Erase Wallcovering: Smooth, clear, dry erase surface over a vinyl material. 1. Product # WWWO-White; 59/60 inches wide, Type II Weight, wallcovering backing. Designed as a writable surface. 2. Product # WWPC-White; 59/60 inches wide, Type II Weight, wallcovering backing. Designed for projection and writing. 3. Product #WWWO-Cream; 59/60 inches wide, Type II Weight, wallcovering backing. Designed as a writable surface. 2.3 ACCESSORIES A. Adhesives: Heavy duty clay-based adhesive. B. Substrate Primer/Sealer: WX`hite pigmented acrylic/latex base primer specifically formulated for use with vinyl wallcoverings. C. Aluminum Tray: 1. Product #: WW-Box-Tray Clear satin anodized aluminum, box style tray for markers and erasers. Sold in 8-foot sections. Requires end-caps. 2. Product #WW-Flat-Tray Clear satin aluminum, blade type tray for markers and erasers. Sold in 8-foot sections and can be cut for an additional charge. Has rounded ends and does not require end-cap.

Part 3 EXECUTION D. Aluminum SnapTrim: 1. Product#: WW-Snap-Trim Clear satin anodized aluminum flat trim with attaching clips. E. Aluminum Trim with Cork Insert 1. Product#: WW-Cork-Trim Clear flat anodized aluminum trim with cork insert. Specify width: 1 or 2-inches wide. F. Write Walls Micro-fiber Eraser 1. Product#: Write Walls Micro-fiber Eraser. G. Expo Bold Markers 1. Product#: Expo Bold Color Markers (4-pack) H. Expo Cleaner 1. Product#: Expo Cleaner Liquid Cleaner. 8-oz. spray bottle. 3.1 EXAMINATION A. Examine substrates and installation conditions to ensure surface conditions meet or exceed a Level 4 wall finish, GA-14-M-97 Recommended Levels of Gypsum Board Finish. B. Test substrates with suitable moisture meter and verify that moisture content does not exceed 5 percent. C. Verify substrate surfaces are clean, dry, smooth, structurally sound and free from surface defects and imperfections that would show through the finished surface. D. Evaluate all painted surfaces for the possibility of pigment bleed-through. E. Notify the contractor and architect in writing of any conditions detrimental to the proper and timely completion of the installation. F. Beginning of installation means acceptance of surface conditions. G. Installation over a minimum Level 4 wall surface is necessary. 3.2 INSTALLATION A. Acclimatize wallcovering to the area of installation a minimum of 72 hours before installation. B. Read and follow the instructions in the manufacturer s installation sheet contained in each shipment of the dry erase wallcovering.

C. Examine all materials for pattern, color, quantity and quality as specified for the correct location prior to cutting. D. Adhesive: Use high quality, heavy duty, pre-mixed, strippable clay-based vinyl adhesive recommended for fabric backed vinyl wallcovering and approved by manufacturer. E. Primer: Use a high quality, white-pigmented acrylic/latex base primer specifically formulated for use with vinyl wallcoverings. F. Install each roll in sequence starting from the highest to the lowest number and in exact order as they are cut from the bolt. G. Install dry erase wallcovering panels in exact order as they are cut from the bolt. Reverse hang alternate strips. Do not crease the wallcovering. I. Install dry erase wallcovering horizontally using a level line. Using level or straight edge, double-cut the seam with a new razor or knife. J. When covering the entire wall, horizontal seams should be placed outside of the main writing area. K. Smooth wallcovering to the hanging surface using a wallcovering smoothing tool wrapped in a clean, soft cloth to eliminate air bubbles, wrinkles, gaps and overlaps. Do not use hard, abrasive or sharp edge smoothing tools. Smooth material on the wall from the middle to the outside edge. L. Remove excess adhesive along finished seams immediately after each wallcovering strip is applied. Clean entire surface with warm, clean water and a natural sponge. Rinse thoroughly with water and towel dry. Change water often to maintain water cleanliness. M. Stop installation of material that is questionable in appearance and notify the manufacturer s representative for an inspection. 3.3 CLEAN-UP COMPLETION A. Upon completion of installation, wash the wallcovering with Expo cleaning solution. Then rinse thoroughly with clean water and towel dry prior to using. B. Upon completion of the work, remove surplus materials, rubbish and debris resulting