For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

Similar documents
LV Series. SEER 20+ Wall Mount Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

Up to SEER 26.1 Wall Mount Heat Pump

FAQ. Wall Mount Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only

FTQ. Daikin Inverter Ducted Heat Pump

MXL SERIES - ENHANCED CAPACITY

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

Daikin Inverter Ducted Systems

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

About Daikin: WARNINGS:

Split Type System. Air to Water Heat Pump

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

Single and Multi-Zone Systems Reference Guide

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Residential and Light Commercial Ductless Systems Catalog

Single and Multi-Zone Systems Reference Guide

"I'm a Daikin Comfort Pro"

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

SiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

LV SERIES DUCTLESS WALL-MOUNTED SINGLE-SPLIT HEAT PUMP UP TO 24.5 SEER, UP TO 12.5 HSPF INVERTER, VARIABLE-SPEED COMPRESSOR COMFORT FOR LIFE

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

DUCTLESS PRODUCTS REFERENCE GUIDE

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

A single answer for multiple zones.

Variable Refrigerant Flow

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

A single answer for multiple zones.

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

DUCTLESS PRODUCTS REFERENCE GUIDE 04.15

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

DUCTLESS FULL LINE CATALOG

LG VRF Systems. Air Conditioning Technologies

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

The Multi-talented VRV-S.

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Inverter Wall Mounted Series

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

TECHNICAL SPECIFICATIONS

Superior Technology and Integration VARIABLE REFRIGERANT FLOW SYSTEMS

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

Ductless Split Systems Ceiling Cassette Heat Pumps

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

TECHNICAL SPECIFICATIONS

Heat Pump Air Conditioning Systems

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

TECHNICAL SPECIFICATIONS

Inverter Wall Mounted

A WORLD LEADING MANUFACTURER

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Lennox Mini-Split Systems Year-Round Comfort and Performance

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Ducted Air Conditioning

3 rd Generation of VRV. The professional solution for your professional project

Split Type Air Conditioners

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Energy Efficiency Demonstration Residential Ductless Heat Pumps (DHP) Overview. Ammi Amarnath Chris Trueblood

InverterFlex SERIES InverterFlex Systems condition up to five rooms

HEAT PUMPS. Efficient Comfort For Every Season

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

TECHNICAL & SERVICE MANUAL

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

2 &3-4 Head Multi System

Here is the common bond that can put it all together.

Technical Product Guide

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

THE WORLD S MOST EFFICIENT HEAT PUMP

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Light commercial range. Passion at work

ELECTRICAL QUANTITY WEIGHT (LB)

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

The Hyper-Heat Advantage

Transcription:

For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System

EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone comfort. Connecting up to 8 indoor units to a single outdoor unit reduces installation space and costs while maximizing comfort and energy savings. With a choice of three indoor unit types in a wide range of capacities, the Super Multi Plus allows mixed and matched combinations for absolute comfort in almost any residential application. ENERGY EFFICIENCY Integrated with an inverter variable speed compressor, Daikin Super Multi PLUS systems deliver the capacity required to maintain desired room conditions, typically reducing energy consumption by 30% compared to traditional fixed speed systems. This technology minimizes temperature fluctuations and provides continuous cooling and heating comfort with maximum energy savings. INDIVIDUAL COMFORT AND CONTROL The standard wireless controller provides individual temperature control at the click of the button. Most Indoor units are also compatible with the new Daikin ENVi intelligent thermostat, offering a more advanced solution, designed with energy savings performance in mind. With the freedom to access, program and control the system from a smart phone, tablet, or computer, users can have peace of mind anytime, anywhere. BUILT IN RELIABILITY Note: The Daikin ENVi thermostat is not compatible with the FFQ Indoor Units All major components are engineered and manufactured by Daikin, ensuring maximum performance, reliability and efficiency. The standard warranty provides a solid level of protection on the Super Multi PLUS system. Systems installed by an authorized Daikin Dealer who has completed Daikin s advanced training can take advantage of Warranty Plus the best warranty in the industry. Find a Daikin Dealer near you at www.daikinac.com.

DESIGN FLEXIBILITY The Super Multi PLUS Split System can be combined with a variety of ducted and ductless models with a total of 15 indoor unit variations. Indoor Unit Availability Capacity Indoor Type 7 MBH 9 MBH 12 MBH 15 MBH 18 MBH 24 MBH Wall Mount Slim Duct 2' x 2' Cassette CTXS_H, CTXS_LV, FTXS_LV Wall Mounted Unit Blends with any décor with it s sleek and sophisticated design Enhanced indoor air quality with the titanium apatite photocatalytic air purification filter which absorbs microscopic particles and decomposes odors Increased energy savings with the intelligent eye function which reduces operation in unoccupied spaces FDXS_LV, CDXS_LV Concealed Slim Duct Maximized floor and wall space with it s compact and concealed design Undisturbed comfort with low operating sound levels Cleaner air with the removal or airborne dust particles by the standard mold proof air filter NEW! FFQ_LV 2 X 2 Ceiling Cassette Enhanced comfort with uniform airflow and temperature distribution Draught free protection with horizontal air discharge Simple installation with an easy to fit decoration panel that blends with any interior design Easy maintenance with an easy to clean grille and washable long life filter BPMKS Branch Provider Unit Varies the refrigerant volume to meet the cooling or heating requirements of each room connected to the system. Facilitates zone on/off and capacity control to operate rooms individually via zone temperature controls Simple installation with flare nut connections REFNET joint Reduces the amount of work involved in installation and increases the reliability of the system.

LEADING TECHNICAL PERFORMANCE Up to 8 indoor units can be connected to a single outdoor unit A High Efficiency solution with optimum flexibility to provide zoning for with the connection of up to 8 indoor units utilizing long pipe lengths, ease of installation with standardized linesets, simplified electrical requirements and staged installations Outdoor Units RMXS48LVJU BP Units Up to 2 Zones Up to 3 Zones Model Name RMXS48LVJU Model Name BPMKS048A2U BPMKS049A3U Nominal Capacity (Cooling / Heating) Btu/h 48,000 / 54,000 Non Ducted 18.8 / 11.3 SEER / HSPF Mixed 16.5/10.5 Ducted 14.1/9.6 Non Ducted 10.3/3.0 EER / COP Mixed 9.8/2.9 Power Supply Single phase 60Hz 208/230V Ducted 9.3/2.7 Power Consumption W 10 10 Power Supply 208/230V - 1Ø - 60Hz Running Current A 0.05 0.05 Minimum Circuit Amps A 27.0 Sound Pressure - (Cooling/Heating) db(a) 32/32 32/32 Maximum Overcurrent Protection A 30.0 Number of Connectable Indoor Units 1 to 2 1 to 3 Sound Pressure - (Cooling/Heating) db(a) 56/58 Min. Connection Combination 7,000 7,000 Connection Ratio (Max Capacity for BPMKS Boxes) 50-130% Max. Connection Combination 48,000 62,000 Number of Connectable Indoor Units 2 to 8 Outdoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3 Number of Connectable BP Units 1 to 3 Liquid Indoor Unit Side in. Ø 1/4 x 2 Ø 1/4 x 3 Total System Piping Length ft. (m) 440 (135) Piping Connection Type Flare Flare Max. Piping Length(OU to BP Box) ft. (m) 180 (55) Connections Outdoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3 Max. Piping Length(IU to BP Box) ft. (m) 49 (15) (O.D.) Gas Indoor Unit Side in. Ø 5/8 x 2 Ø 5/8 x 3 Total Piping Length (OU to BP Box) ft. (m) 180 (55) Connection Type Flare Flare Total Piping Length (BP to IU) ft. (m) 262 (80) Dimensions (H x W x D) in. 7-1/16 x 11-9/16 x 13-3/4 Max. Piping Height (OU to IU) ft. (m) 98 (30) Net Weight lbs. 18.0 20.0 Max. Piping Height (IU to BP Box) ft. (m) 98 (30) Max. Piping Height (BP to BP Box) ft. (m) 49 (15) Nominal Conditions: Cooling Mode Heating Mode Piping Connection Kit KHRP26A22T Indoor: 80 F DB / 67 F WB Indoor: 70 F DB Operating Range (Cooling/Heating) F DB 23 115/5-75 Note: Outdoor: 95 F DB Outdoor: 47 F DB / 43 F WB Specifications are subject to change without notice. Dimensions (H x W x D) in. 52-15/16 x 35-7/16 x 12-5/8 Pipe Length: 25 ft. Pipe Length: 25 ft. Net Weight lbs. 283.0 Level Difference: 0 ft. Level Difference: 0 ft. Indoor Units - CTXS_HVJU, CTXS_LVJU, and FTXS_LVJU Wall Mounted Units 0.6 Ton 0.75 Ton 1.0 Ton 1.25 Ton 1.5 Ton 2.0 Ton Model Name CTXS07LVJU CTXS09HVJU CTXS12HVJU FTXS15LVJU FTXS18LVJU FTXS24LVJU Airflow-Wet (H/M/L/SL) CFM 332/261/194/145 388/335/283/- 388/335/283/- 568/477/385/360 583/484/385/360 643/494/350/328 Airflow-Dry (H/M/L/SL) CFM 350/290/233/219 400/357/314/- 400/357/314/- 593/505/417/371 625/526/431/399 699/572/445/403 Sound Pressure - Cooling (H/M/L/SL) db(a) 38/32/25/22 44/40/35/- 45/41/36/- 45/40/35/32 46/41/36/33 51/44/37/34 Sound Pressure - Heating (H/M/L/SL) db(a) 38/33/28/25 44/39/34/- 45/40/35/- 43/38/33/30 45/40/35/32 48/42/37/34 Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Piping Connections Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 5/8 Condensate Drain Connection (O.D.) in. Ø 5/8 Ø 11/16 Ø 11/16 Ø 5/8 Ø 5/8 Ø 5/8 Dimensions (H x W x D) in. 11-5/8 x 31-1/2 x 8-7/16 11-7/16 x 31-5/16 x 9-3/8 13-3/8 x 41-5/8 x 9-3/4 Net Weight lbs. 20.0 20.0 20.0 31.0 31.0 31.0 Indoor Units - FDXS_LVJU and CDXS_LVJU Slim Duct Units Model Name FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU External Static Pressure "W.G. 0.12 0.12 0.16 0.16 0.16 Airflow-Wet (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297 Airflow-Dry (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297 Sound Pressure - Cooling (H/M/L/SL) db(a) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31 Sound Pressure - Heating (H/M/L/SL) db(a) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 37/35/33/31 Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Piping Connections Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Ø 1/2 Condensate Drain in. Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32 Ø 25/32 Dimensions (H x W x D) in. 7-7/8 x 27-9/16 x 24-7/16 7-7/8x35-7/16x24-7/16 Net Weight lbs. 47.0 47.0 60.0 60.0 60.0 Indoor Units - FFQ_LVJU 2 x2 Duct Units Model Name FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU Airflow Rate (H/L) CFM 318/230 353/230 424/283 530/353 Sound Pressure - Cooling (H/L) db(a) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 Sound Pressure - Heating (H/L db(a) 35/33/31/- 35/33/31/- 37/35/33/31 37/35/33/31 Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4 Ø 1/4 Piping Connections Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 1/2 Ø 1/2 Condensate Drain (O.D.) in. Ø 1-1/32 Ø 1-1/32 Ø 1-1/32 Ø 1-1/32 Dimensions Unit (H x W x D) in. 11-1/4 x 22-5/8 x 22-5/8 Dimensions Deco Panel (H x W x D) in. 2-1/4 x 27-5/8 x 27-5/8 Net Weight lbs. 38.5 38.5 38.5 38.5

TIME SAVING INSTALLATION AND EASE Longer Refrigerant Piping Longer refrigerant piping capabilities offers much more flexibility in the choice of installation positions for the indoor units, and greatly simplifies system layout. Piping Requirements Maximum allowable length Allowable Length Details Between outdoor and BP units Total piping length Piping length between outdoor and BP units 180 ft (55 m) - [Example] a+b+c+d+e 180 ft Between BP and indoor units Total piping length Piping length between BP and indoor units: 262 ft (80 m) - [Example] f+g+h+i+j+k+l 262ft Between BP and indoor unit 1 room length Piping length between BP and indoor unit 49 ft (15 m) - [Example] f, g, h, i, j, k, l 49 ft Between outdoor and indoor units Difference in height between outdoor and indoor units (H1) 98 ft (30 m) Allowable height Between outdoor and BP units Difference in height between outdoor and BP units (H2) 98 ft (30 m) Difference in height Between BP and BP units Difference in height between BP and BP units (H3) 49 ft (15 m) Between indoor and indoor units Difference in height between indoor and indoor units (H4) 49 ft (15 m) Minimum allowable length Allowable length after the REFNET branch Piping length Pipe length between outdoor unit and first refrigerant branch kit (refnet joint) 16.4 ft [Example] a 16.4 ft Piping length from first refrigerant branch kit (REFNET joint) to indoor unit 131 ft (40 m) [Example] unit 6: b+c+k 131 ft [Example] unit 5: b+e+j 131 ft [Example] unit 3: d+h 131 ft Additional refrigerant calculation Simplified Electrical Wiring The outdoor unit and BP units operate from separate 208/230V single phase power supplies. Indoor units are powered from the BP unit and wired as Daikin s current 4 wire single split systems reducing the wiring size and easing installation Space Saving Design More than 60% in physical space savings More than 80% in total (including clearances) space savings Installation Space 12 5/8 Daikin RMXS 35 7/16 38 11/16 Traditional Outdoor Unit 35 1/8

System Operation Range Cooling Operation Heating Operation 23 FDB 115 FDB Ambient Temperature 57 FWB 82 FDB Indoor Room Temperature 5 FDB 60 FWB Ambient Temperature 50 FDB 82 FDB Indoor Room Temperature Note: No low ambient option exists with this product line. WARNINGS: Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User s Manual carefully before using this product. The User s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. For any inquiries, contact your local Daikin sales office. Use of the AHRI Certified mark indicates a manufacturer's participation in the certification program. For verification of certification for individual products, go to www.ahridirectory.org 2013 Daikin Industries, Limited. Daikin, Daikin AC Absolute Comfort, and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, LTD. www.likin-daikin.com Distributor or Dealer Information: Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 www.daikinac.com 866.4DAIKIN 972.245.1510 PFSMPUSE13-01R For all equipment installation & application limitations please refer to the specific Engineering Data Books. Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations.

Sales Bulletin #MS004 Date: January 15, 2013 To: Daikin Sales, Service, and Distribution Subject: New 4-Ton 8 Zone Super Multi PLUS System (RMXS) and New Multi-Split Indoor Units Daikin AC is pleased to introduce the new 8 Zone Super Multi PLUS System targeting residential and light commercial markets. The Super Multi PLUS complements and expands our current multi-split portfolio and provides superior efficiency and flexibility with the ability to connect 2 to 8 indoor units from a variety of indoor unit options including Daikin s new 2 X 2 ceiling cassette units (9 18 MBH), wall mounted units (7 MBH 24 MBH), and new extended range of slim duct units (9 24 MBH). Product Overview The Super Multi PLUS system is available from April 2013 and the launch will include the following new models: - RMXS48LVJU BPMKS048A2U BPMKS049A3U CDXS24LVJU FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU 4.0 Ton Super Multi PLUS Condensing Unit 2 Zone Branch Provider Box 3 Zone Branch Provider Box 2.0 Ton Slim Duct Built-in Unit 0.75 Ton 2 X 2 Ceiling Cassette Unit 1.0 Ton 2 X 2 Ceiling Cassette Unit 1.25 Ton 2 X 2 Ceiling Cassette Unit 1.5 Ton 2 X 2 Ceiling Cassette Unit Daikin AC s new Branch Provider (BP) unit allows the Super Multi PLUS to connect from 2 to 8 indoor units with indoor unit capacities up to 130% (62,000 Btu/h) of the outdoor unit. Daikin AC ( A merica s), Inc. 1645 W allace Drive, Sui t e 110

Carrollton, T X 75006 972-245-1510 www.daikinac.com Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 2 of 10 Product Information The new Super Multi can serve up to 8 rooms with the addition of indoor units extending our current range of indoor unit availability to include a total of 15 models in 3 different types for design flexibility with individual comfort control. Product class leading efficiency levels (4-Ton Multi-Split Heat Pump) are available with ratings up to SEER 18.8 for non-ducted combinations and up to HSPF 11.3. 2 X 2 Ceiling Cassette (New) To meet the growing demand of the market and to satisfy the requests of customers, Daikin AC is pleased to introduce the new 2 X 2 ceiling cassette, FFQ_LVJU, for multisplit systems only to complement our current range of indoor units. These units provide customizable comfort with four-way directional airflow and easy adjustments for corner or corridor installation. Compact with an easy-to-clean grille and sophisticated decoration panel, these units are designed to fit nearly flush with or into a standard ceiling tile for an unobtrusive interior finish. Ideal for both residential and light commercial applications, the 2 X 2 is great for new or retrofit homes, offices, and retail spaces. The 2 X 2 is compatible with the new Navigation Remote Controller BRC1E72. The configurable display offers 3 options with an advanced display great for residential applications and a simplified display ideal for applications such as hotels wanting to only provide the necessary buttons to users for comfort without confusion. Refer to Sales Bulletin #CT013 for more information. Wall Mount (Extended Range) and Slim Duct (New) Units

Branch Provider (BP) Unit The new slim duct, CDXS24LVJU, and addition of the current LV-Series wall mount, FTXS24LVJU, extends the indoor unit capacity range up to 24 MBH, enhancing the versatility of the Super Multi and offering solutions for larger spaces having more cooling or heating requirements. Indoor units are provided with a wireless controller as standard or can be utilized with the new optional Daikin ENVi controller for smart comfort available April 2013 (more information to come at the end of January). Please note indoor units in 24 MBH capacities are only available with the Super Multi PLUS. The BPMKS Branch Provider boxes allow indoor units of different capacities to be connected and then vary refrigerant volume to meet cooling and heating requirements of individual room zones. Available in 2 and 3 port units, up to 3 BP units can be connected to the Super Multi PLUS for initial full system integration or phased installation. To simplify installation the BP boxes come with flare connections removing the need for brazing at the box location. Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 3 of 10 Technical Specifications Outdoor Units BP Units

Indoor Units Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 4 of 10 Piping Limitations

Piping Requirements Between outdoor and Maximum BP units allowable Between BP and length indoor units Between BP and indoor unit Between outdoor and Allowable indoor units height Between outdoor and BP units Between BP and BP units Between indoor and indoor units Minimum allowable length Allowable length after the REFNET branch Additional refrigerant calculation Total piping length Total piping length 1 room length Difference in height Difference in height Difference in height Difference in height Piping length Branch with REFNET Joint Piping length between outdoor and BP units 180 ft (55 m) [Example] a+b+c+d+e 180 ft Piping length between BP and indoor units: 262 ft (80 m) [Example] f+g+h+i+j+k+l 262ft Piping length between BP and indoor unit 49 ft (15 m) [Example] f, g, h, i, j, k, l 49 ft Difference in height between outdoor and indoor units (H1) 98 ft (30 m) Difference in height between outdoor and BP units (H2) 98 ft (30 m) Difference in height between BP and BP units (H3) 49 ft (15 m) Difference in height between indoor and indoor units (H4) 49 ft (15 m) Pipe length between outdoor unit and first refrigerant branch kit (refnet joint) 16.4 ft [Example] a 16.4 ft Piping length from first refrigerant branch kit (REFNET joint) to indoor unit 131 ft (40 m) [Example] unit 6: b+c+k 131 ft [Example] unit 5: b+e+j 131 ft [Example] unit 3: d+h 131 ft Electrical Wiring The outdoor unit and BP units operate from separate 208/230V single-phase power supplies. Indoor units are powered from the BP unit and

wired as Daikin s current 4 wire single split systems reducing the wiring size and easing installation Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 5 of 10 Operation Range Cooling Operation 23 FDB 115 FDB Ambient Temperature 57 FWB 82 FDB Indoor Room Temperature Heating Operation 5 FDB 60 FWB Ambient Temperature 50 FDB 82 FDB Indoor Room Temperature Note: No low ambient option exists with this product line. Competitive Comparison Technical Specification vs. Competing Manufacturer Daikin AC Manufacturer Company M Company F Company L RMXS48LVJU Nominal Cooling Capacity Btu/h 48,000 48,000 48,000 54,000 Maximum Cooling Capacity Btu/h 54,000 54,000 51,100 63,200 Nominal Heating Capacity at 47 F Btu/h 54,000 54,000 54,000 58,000 Maximum Heating Capacity at Btu/h 61,000 60,000 57,000 64,000 47 F Non Ducted 18.8 / 11.3 15.0 / 8.7 17.0 / 9.8 18.4 / 8.7 SEER / HSPF Mixed 16.5 / 10.5 14.8 / 8.8 15.8 / 9.5 17.1 / 8.3 Ducted 14.1 / 9.6 14.7 / 8.9 14.7 / 9.3 15.8 / 8.0 Non Ducted 10.3 / 3.0 8.3 / 3.28 9.25 / - 10.3 / 3.1 EER / COP 47F Mixed 9.8 / 2.9 7.8 / 3.14 8.97 / - n/a Ducted 9.3 / 2.7 7.4 / 3.00 8.70 / - n/a Maximum Overcurrent MOP (A) 30A 50A 40A N/A Protection Minimum Circuit Amps MCA (A) 27A 32A N/A N/A Connected Capacity % 50 130 22-130 80-130 * - 135

Connectable Indoor Capacity Btu/h 24,000-62,400 70,200 62,000 73,000 Cooling Operating Range F DB 23 115 23 115 23 115 14 118.4 Heating Operating Range F DB 5 75 5 70 5 75 0 75 Total 433.0 377.0 377.0 475.7 Max. Pipe Length ft OU to IU 230.0 230.0 180.0 295.3 Box to IU 49.0 49.0 49.0 49.2 OU to Box 98.0 49.0 98.0 n/a Max Pipe Height Difference ft IU to IU 49.0 39.0 49.0 49.2 OU to IU 98.0 98.0 98.0 98.4 Indoor Unit Availability Indoor Type Wall Mounted Duct Mounted 2 X 2 4 Way Ceiling Cassette Capacity (MBH) 07 09 12 15 18 24 09 12 15 18 24 09 12 15 18 24 Daikin AC Company M Company L Company F Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 6 of 10 Product and Document Availability Product and Documentation January February March April TRL Pricing Sales Presentation Submittal Data Sheets Engineering Data Book Installation & Operations Manual Product Flyer General Catalogue Sales Availability Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 7 of 10

Appendix System Capacity Details versus Combination Ratio Connected Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity(kBT U/h) Power Consumption (kw) 43.2 90.0% 49.0 4.80 43.7 91.0% 49.5 4.85 44.2 92.0% 50.0 4.90 44.6 93.0% 50.5 4.95 45.1 94.0% 51.0 5.00 45.6 95.0% 51.5 5.05 46.1 96.0% 52.0 5.10 46.6 97.0% 52.5 5.15 47.0 98.0% 53.0 5.20 47.5 99.0% 53.5 5.24 48.0 100.0% 54.0 5.27 48.5 101.0% 54.1 5.28 49.0 102.0% 54.1 5.28 49.4 103.0% 54.2 5.28 49.9 104.0% 54.2 5.28 50.4 105.0% 54.3 5.29 50.9 106.0% 54.3 5.29 51.4 107.0% 54.4 5.29 51.8 108.0% 54.4 5.29 52.3 109.0% 54.5 5.29 52.8 110.0% 54.5 5.30 53.3 111.0% 54.6 5.30 53.8 112.0% 54.6 5.30 54.2 113.0% 54.7 5.30 54.7 114.0% 54.7 5.30 55.2 115.0% 54.8 5.31 55.7 116.0% 54.8 5.31 56.2 117.0% 54.9 5.31 56.6 118.0% 54.9 5.31 57.1 119.0% 55.0 5.31 57.6 120.0% 55.0 5.32 58.1 121.0% 55.1 5.32 58.6 122.0% 55.1 5.32 59.0 123.0% 55.2 5.32 59.5 124.0% 55.2 5.32 60.0 125.0% 55.3 5.33 60.5 126.0% 55.3 5.33 61.0 127.0% 55.4 5.33 61.4 128.0% 55.4 5.33 61.9 129.0% 55.5 5.33 62.0 129.2% 55.5 5.34 Heating (60 Hz 230/208V) with Ducted Indoor Units Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity(kBT U/h) Power Consumption (kw) 24.0 50.0% 29.0 2.58 24.5 51.0% 29.5 2.62 25.0 52.0% 30.0 2.68 25.4 53.0% 30.5 2.74 25.9 54.0% 31.0 2.80 26.4 55.0% 31.5 2.86 26.9 56.0% 32.0 2.92 27.4 57.0% 32.5 2.98 27.8 58.0% 33.0 3.04

28.3 59.0% 33.5 3.10 28.8 60.0% 34.0 3.16 29.3 61.0% 34.5 3.21 29.8 62.0% 35.0 3.27 30.2 63.0% 35.5 3.33 30.7 64.0% 36.0 3.39 31.2 65.0% 36.5 3.45 31.7 66.0% 37.0 3.50 32.2 67.0% 37.5 3.56 32.6 68.0% 38.0 3.62 33.1 69.0% 38.5 3.67 33.6 70.0% 39.0 3.73 34.1 71.0% 39.5 3.79 34.6 72.0% 40.0 3.84 35.0 73.0% 40.5 3.90 35.5 74.0% 41.0 3.95 36.0 75.0% 41.5 4.01 36.5 76.0% 42.0 4.06 37.0 77.0% 42.5 4.12 37.4 78.0% 43.0 4.17 37.9 79.0% 43.5 4.22 38.4 80.0% 44.0 4.28 38.9 81.0% 44.5 4.33 39.4 82.0% 45.0 4.38 39.8 83.0% 45.5 4.44 40.3 84.0% 46.0 4.49 40.8 85.0% 46.5 4.54 41.3 86.0% 47.0 4.59 41.8 87.0% 47.5 4.64 42.2 88.0% 48.0 4.70 42.7 89.0% 48.5 4.75 Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 8 of 10

Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity(kBT U/h) Power Consumption (kw) 43.2 90.0% 49.0 3.67 43.7 91.0% 49.5 3.70 44.2 92.0% 50.0 3.74 44.6 93.0% 50.5 3.77 45.1 94.0% 51.0 3.81 45.6 95.0% 51.5 3.84 46.1 96.0% 52.0 3.87 46.6 97.0% 52.5 3.91 47.0 98.0% 53.0 3.94 47.5 99.0% 53.5 3.98 48.0 100.0% 54.0 3.98 48.5 101.0% 54.1 3.99 49.0 102.0% 54.2 3.99 49.4 103.0% 54.3 4.00 49.9 104.0% 54.4 4.00 50.4 105.0% 54.5 4.01 50.9 106.0% 54.6 4.01 51.4 107.0% 54.7 4.02 51.8 108.0% 54.8 4.02 52.3 109.0% 54.9 4.02 52.8 110.0% 55.0 4.03 53.3 111.0% 55.1 4.03 53.8 112.0% 55.2 4.04 54.2 113.0% 55.3 4.04 54.7 114.0% 55.4 4.04 55.2 115.0% 55.5 4.05 55.7 116.0% 55.6 4.05 56.2 117.0% 55.7 4.05 56.6 118.0% 55.8 4.06 57.1 119.0% 55.9 4.06 57.6 120.0% 56.0 4.06 58.1 121.0% 56.1 4.06 58.6 122.0% 56.2 4.07 59.0 123.0% 56.3 4.07 59.5 124.0% 56.4 4.07 60.0 125.0% 56.5 4.08 60.5 126.0% 56.6 4.08 61.0 127.0% 56.7 4.08 61.4 128.0% 56.8 4.08 61.9 129.0% 56.9 4.08 62.0 129.2% 57.0 4.09 Heating (60 Hz 230/208V) with Wall Mounted Indoor Units Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity(kBT U/h) Power Consumption (kw) 24.0 50.0% 29.0 2.13 24.5 51.0% 29.5 2.17 25.0 52.0% 30.0 2.21 25.4 53.0% 30.5 2.25 25.9 54.0% 31.0 2.30 26.4 55.0% 31.5 2.34 26.9 56.0% 32.0 2.38 27.4 57.0% 32.5 2.42 27.8 58.0% 33.0 2.46 28.3 59.0% 33.5 2.50 28.8 60.0% 34.0 2.54 29.3 61.0% 34.5 2.58

29.8 62.0% 35.0 2.62 30.2 63.0% 35.5 2.66 30.7 64.0% 36.0 2.70 31.2 65.0% 36.5 2.74 31.7 66.0% 37.0 2.78 32.2 67.0% 37.5 2.82 32.6 68.0% 38.0 2.86 33.1 69.0% 38.5 2.90 33.6 70.0% 39.0 2.93 34.1 71.0% 39.5 2.97 34.6 72.0% 40.0 3.01 35.0 73.0% 40.5 3.05 35.5 74.0% 41.0 3.09 36.0 75.0% 41.5 3.12 36.5 76.0% 42.0 3.16 37.0 77.0% 42.5 3.20 37.4 78.0% 43.0 3.24 37.9 79.0% 43.5 3.27 38.4 80.0% 44.0 3.31 38.9 81.0% 44.5 3.35 39.4 82.0% 45.0 3.38 39.8 83.0% 45.5 3.42 40.3 84.0% 46.0 3.46 40.8 85.0% 46.5 3.49 41.3 86.0% 47.0 3.53 41.8 87.0% 47.5 3.56 42.2 88.0% 48.0 3.60 42.7 89.0% 48.5 3.63 Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 9 of 10

Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity (kbtu/h) Power Consumption (kw) 43.2 90.0% 43.2 4.39 43.7 91.0% 43.7 4.47 44.2 92.0% 44.2 4.55 44.6 93.0% 44.6 4.63 45.1 94.0% 45.1 4.71 45.6 95.0% 45.6 4.79 46.1 96.0% 46.1 4.88 46.6 97.0% 46.6 4.96 47.0 98.0% 47.0 5.04 47.5 99.0% 47.5 5.13 48.0 100.0% 48.0 5.13 48.5 101.0% 48.1 5.14 49.0 102.0% 48.2 5.15 49.4 103.0% 48.3 5.15 49.9 104.0% 48.4 5.16 50.4 105.0% 48.5 5.16 50.9 106.0% 48.6 5.17 51.4 107.0% 48.7 5.17 51.8 108.0% 48.8 5.18 52.3 109.0% 48.9 5.18 52.8 110.0% 49.0 5.19 53.3 111.0% 49.1 5.19 53.8 112.0% 49.2 5.20 54.2 113.0% 49.3 5.20 54.7 114.0% 49.4 5.21 55.2 115.0% 49.5 5.21 55.7 116.0% 49.6 5.22 56.2 117.0% 49.7 5.22 56.6 118.0% 49.8 5.23 57.1 119.0% 49.9 5.23 57.6 120.0% 50.0 5.24 58.1 121.0% 50.1 5.24 58.6 122.0% 50.2 5.25 59.0 123.0% 50.3 5.25 59.5 124.0% 50.4 5.26 60.0 125.0% 50.5 5.26 60.5 126.0% 50.6 5.27 61.0 127.0% 50.7 5.27 61.4 128.0% 50.8 5.28 61.9 129.0% 50.9 5.28 62.0 129.2% 51.0 5.28 Cooling (60 Hz 230/208V) with Ducted Indoor Units Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity (kbtu/h) Power Consumption (kw) 24.0 50.0% 24.0 1.92 24.5 51.0% 24.5 1.97 25.0 52.0% 25.0 2.01 25.4 53.0% 25.4 2.06 25.9 54.0% 25.9 2.11 26.4 55.0% 26.4 2.16 26.9 56.0% 26.9 2.21 27.4 57.0% 27.4 2.26 27.8 58.0% 27.8 2.31 28.3 59.0% 28.3 2.36 28.8 60.0% 28.8 2.42 29.3 61.0% 29.3 2.47

29.8 62.0% 29.8 2.53 30.2 63.0% 30.2 2.58 30.7 64.0% 30.7 2.64 31.2 65.0% 31.2 2.70 31.7 66.0% 31.7 2.75 32.2 67.0% 32.2 2.81 32.6 68.0% 32.6 2.87 33.1 69.0% 33.1 2.93 33.6 70.0% 33.6 2.99 34.1 71.0% 34.1 3.06 34.6 72.0% 34.6 3.12 35.0 73.0% 35.0 3.18 35.5 74.0% 35.5 3.25 36.0 75.0% 36.0 3.31 36.5 76.0% 36.5 3.38 37.0 77.0% 37.0 3.45 37.4 78.0% 37.4 3.51 37.9 79.0% 37.9 3.58 38.4 80.0% 38.4 3.65 38.9 81.0% 38.9 3.72 39.4 82.0% 39.4 3.79 39.8 83.0% 39.8 3.87 40.3 84.0% 40.3 3.94 40.8 85.0% 40.8 4.01 41.3 86.0% 41.3 4.09 41.8 87.0% 41.8 4.16 42.2 88.0% 42.2 4.24 42.7 89.0% 42.7 4.32 Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.) Page 10 of 10

Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity(kBT U/h) Power Consumption (kw) 43.2 90.0% 43.2 3.91 43.7 91.0% 43.7 3.98 44.2 92.0% 44.2 4.05 44.6 93.0% 44.6 4.13 45.1 94.0% 45.1 4.20 45.6 95.0% 45.6 4.28 46.1 96.0% 46.1 4.35 46.6 97.0% 46.6 4.43 47.0 98.0% 47.0 4.51 47.5 99.0% 47.5 4.59 48.0 100.0% 48.0 4.64 48.5 101.0% 48.2 4.65 49.0 102.0% 48.5 4.67 49.4 103.0% 48.7 4.69 49.9 104.0% 48.9 4.71 50.4 105.0% 49.1 4.73 50.9 106.0% 49.3 4.75 51.4 107.0% 49.5 4.77 51.8 108.0% 49.7 4.79 52.3 109.0% 49.9 4.81 52.8 110.0% 50.0 4.82 53.3 111.0% 50.2 4.84 53.8 112.0% 50.4 4.85 54.2 113.0% 50.5 4.87 54.7 114.0% 50.7 4.88 55.2 115.0% 50.8 4.90 55.7 116.0% 50.9 4.91 56.2 117.0% 51.1 4.92 56.6 118.0% 51.2 4.94 57.1 119.0% 51.3 4.95 57.6 120.0% 51.4 4.96 58.1 121.0% 51.5 4.97 58.6 122.0% 51.6 4.98 59.0 123.0% 5.7 4.99 59.5 124.0% 51.8 4.99 60.0 125.0% 51.8 5.00 60.5 126.0% 51.9 5.01 61.0 127.0% 52.0 5.01 61.4 128.0% 52.0 5.02 61.9 129.0% 52.1 5.02 62.0 129.2% 52.1 5.03 Cooling (60 Hz 230/208V) with Wall Mounted Indoor Units Total Indoor Unit Capacity (kbtu/h) Combination (%) Heating Capacity(kBT U/h) Power Consumption (kw) 24.0 50.0% 24.0 1.78 24.5 51.0% 24.5 1.81 25.0 52.0% 25.0 1.85 25.4 53.0% 25.4 1.89 25.9 54.0% 25.9 1.92 26.4 55.0% 26.4 1.96 26.9 56.0% 26.9 2.00 27.4 57.0% 27.4 2.04 27.8 58.0% 27.8 2.09 28.3 59.0% 28.3 2.13 28.8 60.0% 28.8 2.17 29.3 61.0% 29.3 2.22

29.8 62.0% 29.8 2.26 30.2 63.0% 30.2 2.31 30.7 64.0% 30.7 2.35 31.2 65.0% 31.2 2.40 31.7 66.0% 31.7 2.45 32.2 67.0% 32.2 2.50 32.6 68.0% 32.6 2.55 33.1 69.0% 33.1 2.60 33.6 70.0% 33.6 2.66 34.1 71.0% 34.1 2.71 34.6 72.0% 34.6 2.76 35.0 73.0% 35.0 2.82 35.5 74.0% 35.5 2.88 36.0 75.0% 36.0 2.93 36.5 76.0% 36.5 2.99 37.0 77.0% 37.0 3.05 37.4 78.0% 37.4 3.11 37.9 79.0% 37.9 3.17 38.4 80.0% 38.4 3.24 38.9 81.0% 38.9 3.30 39.4 82.0% 39.4 3.36 39.8 83.0% 39.8 3.43 40.3 84.0% 40.3 3.49 40.8 85.0% 40.8 3.56 41.3 86.0% 41.3 3.63 41.8 87.0% 41.8 3.70 42.2 88.0% 42.2 3.76 42.7 89.0% 42.7 3.84 Published by Daikin AC Product Marketing Department (Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)