TM channel block occupancy detector for LocoNet

Similar documents
BDL168. All Scales. LocoNet Occupancy Detector For 16 Detection Sections and up to 8 Transponder Zones

Run Your Trains, Not Your Track!

compact office 24V compact office 24V Lux

compact office 24V compact office 24V Lux

Control box FSTronic DES-FS

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

DOCUMENTATION IPS640

DOCUMENTATION IPS640

SMART BASIC BASIC-IR DAYLIGHT

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Preamplifier Power Supply PPS-02 user's guide

REA 105 Arc Protection Module. Operator s Manual

Door Release Power Supply

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

G34 AU1B (External Ultrasonic Sensor) Version 3

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

C-Bus Four Channel Analogue Output Unit Installation Instructions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Process Alarm Module RTA 421

PresenceLight 180 PresenceLight 360

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Install intelligent room automation flexibly and future-proofed

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

SCAN200E USER S MANUAL

DATASHEET. Burner control unit FDA 601x

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

Imperial War Museum. Case Study 17. clipsal.com UNITED KINGDOM. C-Bus Control and Management System

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

CONTROL DEVICE SLIDETRONIC HD

Connections, displays and operating elements C D E G H. Installing the control unit

Manual MPA 4112 PF. Edition: No GB. Printed in Germany Edition Nr

Laser Distance Sensor Type M Analog-Output

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Multi line separator module

ECO N DATE DESCRIPTION OF CHANGE CHG

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

10 Year Smoke Detector and Siren

EVO192 v3.0 Fire and Burglary What s New

SMART SMOKE DETECTOR

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

Control box FSTronic DES-FI

Engineering Guideline. pac- Carriers Type Universal

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

Azatrax Quad Infrared Proximity Detector Shield for ArduinoTM Uno, Mega and compatibles

Ice Rink (Single and Dual Configurations) Custom Control Features

PYROSELF Innovative Snow Sensor and Controller for 2 x 24A loads outputs. Installation and Operating manual

Passive infrared ceiling sensor

Speed and Frequency Seite 1 von 7

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

External Wireless Sounder

RVL480. Heating Controller

AO Annunciator Module

JA-63 Profi User manual

ELECTRONIC COMMUNICATING THERMOSTAT

MT-374B/364B Operation User s Guide. The Anti-Sweat Energy Saving Controller user s manual

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

ELITE-600 DENTAL PORCELAN FURNACE

Electronic Circuit Controller

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

easydetect and easydetect deluxe model train detector kits Quickar Electronics, Inc.

Manual. PDB + SBEC Module Voltage, Current, Capacity, Telemetry. No. S8474. Copyright Graupner/SJ GmbH

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

OPERATION AND ALARM PANELS

easydetect and easydetect deluxe model train detector kits Quickar Electronics, Inc.

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Push Button Electronic Timer. 31VETR Series. Installation Instructions

External Wireless Sounder

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

CA60Plus. Installation manual

Wireless Internal Siren System Installation Guide

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Data sheet. Function description. Benefits

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Sensors SR Programming manual

ECL Comfort 110, application 116

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Annunciator Unit SACO 16 D1. Product Guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

SMOKE User Manual. NE v2.0

1. Functions of GPS locator ETLOC-30S 3

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

U ser's Guide PC6010

MD12-2 Vehicle Loop Detector

Transcription:

TM-56322 8-channel block occupancy detector for LocoNet User's manual

2016 BioDigit Ltd. All rights reserved. It is forbidden to reproduce and/or publish the contents of the present document in any form including electronic and mechanical design without the written permission of BioDigit Ltd. Safety warning During the operation of the device the specified technical parameters shall always be met. At the installation the environment shall be fully taken into consideration. The device must not be exposed to moisture and direct sunshine. A soldering tool may be necessary for the installation and/or mounting of the devices, which requires special care. During the installation it shall be ensured that the bottom of the device should not contact with a conductive (e.g. metal) surface! Contents Features and properties... 2 Technical parameters... 2 Short description... 3 Low LocoNet current consumption... 3 Occupancy stretcher function... 3 Detector input common-wire, detecting method... 3 Connectors... 4 Wiring... 4 Programming feedback addresses... 4 Guarantee and legal statement... 7

Features and properties Designed for LocoNet system Easy to use, fast programming button Low voltage-drop detector inputs Extremely low (2mA) current threshold for detecting Opto-isolated detector inputs (galvanically separated) Control from rail signal and LocoNet Immediate LED feedback on each inputs Delayed switch-on to prevent false report Automatic power-on feedback report High-efficiency internal switching power supply Adjustable occupancy stretcher No need of external power source Technical parameters Dimensions: 67x56x15 mm Idle mode current consumption: 7mA Max. current on each input: 3000mA Automatic turn-on delay: 0.5 sec Minimum detecting current: 2mA Occupancy feedback stretcher: 0.05 2 sec Supply voltage: 9-24V from LocoNet LocoNet status support: Yes (GPON, GPOFF, IDLE) LocoNet feedback support: Yes (1-2048)

Short description The block occupancy is important information on the layout. The easiest way to use this information globally on layout if the occupancy is reported to LocoNet bus-system. The TM-56322 Block occupancy detector with 8 separated input is cost-effective solution for this application. The TM-56322 using current-flow to detect occupancy, and the enhanced amplified current sensing helps to reduce the voltage-drops on the detector. Every input can be programmed to different feedback addresses, and can be use independently. On board LEDs lights up when the certain input detect occupancy. Low LocoNet current consumption The TM-56322 block occupancy has high-efficiency and low EMI noise switching power supply. Thanks to this internal power supply, the LocoNet current consumption is only few milliamps on LocoNetbus, many module will not cause high load on the bus. Occupancy stretcher function In some cases the occupancy is not constantly detected on the track. Sparking wheels, cars without current consumer loads can cause only short load impulses on the track. The TM-56322 block occupancy detector has internal impulse stretcher. If the short load pulse is detected on the input, the module can stretch it to the desired length (see occupancy stretcher programming mode). The desired time length can be adjusted in 9 step from 0.05 sec to 2 sec. Every, new short load detection will restart the internal timing. Detector input common-wire, detecting method This module is detecting the block occupancy via current consumption on the separated section. To detect, the block occupancy detector need to wired between the common (noncutted) and the separated (cutted) track. When the load (for

example: Loco) is on the track, the current flows through the block occupancy detector. The section common wire is usually the never separated wire of your digital center / booster out. (See figure 1 red wire) The detection common wire is the other output of your booster / digital center. This wire will be separated to sections, but the module needs direct connect to your booster out. (See figure 1 blue wire). Please never chain the detection common wire. Connectors The module has two LocoNet connectors (parallel connected on module), this can be used for daisy-chain LocoNet bus wiring. Furthermore, the module has screwable terminal blocks to rail wiring. Wiring The recommended minimum wire diameter is AWG-24 (approx. 0.2mm 2 ) per inputs. The common wire must be minimum AWG-20 (approx. 0.5 mm 2 ) Attention! Please also keep in mind, the detection common wire always have to larger than block inputs, because all inputs current will flow out via detection common wire. For example, if every section is loaded with 200mA, the detection common wire is loaded with 8 x 200mA = 1.6A! Programming feedback addresses This module has easy to use fast programming method. Can be programmed on the final place on your layout. Every feedback address can be programmed via standard turnout switch command in programming mode. The feedback address range and the turnout address range is almost same.

The switching address is only used for easy address entering, the switching address and feedback address are separated on LocoNet bus. The switching command can be issued on every digital center. Entering programming mode The programming mode has two submode. The first is address programming mode, and the second is occupancy stretcher setting mode. To enter programming mode, press the PROG button at least 0.5 sec., the first LED on the module will light up and blinks, and the module is entered to address programming mode. Address programming submode Every LEDs are behind the associated detector input for easy assignment. If the LED is blinking you can send the turnout / switch command with the desired (feedback) address from your digital center. When the module has received the command the actual LED will light constantly for a second, and it will blink again. To change the next input s feedback address, press PROG button shortly, the blinking will goes to the next. To enter the second input s feedback address, please repeat the previous method (make a switch command on your digital center with desired address). Occupancy stretcher submode To enter occupancy enlarger setting mode, press the PROG button again at least 0.5sec. The 8 LEDs on the module will make a bargraph display to help the setting. The occupancy stretcher time can be modified with PROG button short pressing. Each pressing the delay will be increased from 0.05 sec to 2 sec in nine steps.

Leaving the programming mode To leave programming mode, please press the PROG button again at least 0.5 sec. Every settings will be saved permanently.

Guarantee and legal statement Each parameter of the device will be submitted to comprehensive testing prior to marketing. The manufacturer undertakes one year guarantee for the product. Defects occurred during this period will be repaired by the manufacturer free of charge against the presentation of the invoice. The validity of the guarantee will cease in case of improper usage and/or treatment. Attention! By virtue of the European EMC directives the product can be used solely with devices provided with CE marking. The mentioned standards and brand names are the trademarks of the firms concerned. TrainModules : BioDigit Ltd. LocoNet : Digitrax Inc. NMRA DCC: National Model Railroad Association TrainModules BioDigit Ltd. Cziraki street 26-32. EMG Industrial Park H-1163, Budapest Tel.:+36 1 46-707-64 http://www.trainmodules.com/

Figure 1. Wiring of TM-56322 LocoNet block occupancy feedback module