Multi Key Panel Door Interlock User Manual - Original Language Version

Similar documents
Swaging Machine Type H50-46ECO

We make your Workplace Safe

Tempest TP420/180 Electric Pressure Washer

Original instructions Sense7-series Non-contact coded safety switch

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Model 3.6m. User Manual Original instructions

Muskogee Public Schools. Lockout/Tagout. Program

Contingency Plan for Hazardous Materials and Waste Releases

Washing Machine Installation Instructions

Drywall Screwdriver R INSTRUCTION MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

TITAN FLOW CONTROL, INC.

THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.

ST1. Mod. USE AND MAINTENANCE MANUAL

User Guide LED Ringlight for the Lynx Stereo Dynascopic Microscope

Tower Fan NSTF-06MI IMPORTANT! KEEP FOR FUTURE REFERENCE. Instruction Manual. Please register your product on-line at

CRU-S Series Stainless Steel Condensate Recovery Unit

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Original operating instructions Safety switch with guard locking AC901S AC902S

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE

OPERATING INSTRUCTIONS & Safety Guide. HafcoVac Compressed Air Industrial Vacuum Product Line

Meat Slicer Instruction manual

TRASCO ATEX Couplings

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

This label warns for risk of electrical shock when failing to observe.

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

XB-EFA-8L-BK & XB-EFA-8R-BK

Installation and Wiring Instructions

electric KNIFE ZX863X

Blower UB1100 UB1101 INSTRUCTION MANUAL

ANNEX GD-CERT-EX-EN SIT

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

Drywall Screwdriver INSTRUCTION MANUAL

ATEX Enclosures. Safety in an explosive atmosphere

ASSEMBLY & OPERATING INSTRUCTIONS

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

SensaGuard TM Integrated Latch Installation Instructions

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

Electric Cooker. Important Please read these instructions fully before installing or using

TABLE OF CONTENTS PART 4 - HAND TOOLS AND POWER DRIVEN PORTABLE TOOLS

electric KNIFE ZX711X / ZX773

Self-Regulating Point Heating Performance Requirements

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Sip Vacuum Cleaner 1400/35 Wet & Dry

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

TWINFLOW STDR Installation & Maintenance

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

ENVIROPRESS CAN CRUSHER Model : EP005 / EP005HD

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

42CE Fan Coil Unit. 42CE Fan Coil Unit (340~2720m 3 /h) Read the instructions thoroughly before installing, operating and maintaining the unit.

1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY Warnings and Safety Advice Coolants WARRANTY AND 3 CUSTOMER SERVICE 4.0 INS

GREEN LIFT SYSTEM USE MANUAL WITH PERMANENT MAGNETS * EN* SYSTEM TYPE: q GLPM MRL 1:1 q GLPM MRL 2: EN.

Food Waste Disposer Owner s Manual

One giant leap for safety: AZM400.

"50 BEOWULF" " OPERATION AND MAINTENANCE OF "50 BEOWULF" SOUND SUPPRESSOR

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Lo-Carbon T-series Window & Roof Models

Survey of electrical equipment installed in hazardous areas on tankers

Compact Cyclonic Pro Bagless Cylinder Vacuum Cleaner

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

OPERATING INSTRUCTIONS

18 INCH HIGH VELOCITY FLOOR FAN

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212.

RHT RAIL HEATER. Rail & Switch Point Heating System. Pre-Terminated Lengths or Cut-to-Length from the Reel

Composite Sinks Installation, Use and Maintenance

ISIS SAFETY SYSTEM Installation guide

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

Operating Instructions

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

Operation Manual R205BV, R209BV

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Pocket Hardmount. Preventative Maintenance.

87cm. Cooker hood. Stainless steel JLCEILHD87. User guide

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Installation of Glass Lined Equipment

AXPR Wall Mounted Axial Panel Fans

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

product manual H-1336D, H-1346D & H-1356D H-1336_46_56D_man_0609 Marshall Mechanical Compactors

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

Plug-n-Play (PNP) CARTRIDGE DUST COLLECTORS.

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Installation & User Instructions:

CM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity

MA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

ASSEMBLY AND OPERATING INSTRUCTIONS 1HP DUST EXTRACTOR. FOX Model F50-841

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

MINI-EDGER POLISHER/SCRUBBER

Transcription:

D D-FS-F-1S-RE-MS-4 The D Lock is a two part access interlock comprising of a main body and catch complete with secondary lock portions. The catch is available in two options, one suited to well aligned doors, the other suited to poor, mis-aligned doors. The lock is ideally suited for use on light duty panel doors in dry, non-corrosive environments where the lock is subject to light to medium use. Typical industries using the D Lock are Control Panel uilders, HV and LV Switchgear and the food industry. The D lock is available as F (figure) or Q style of lock portions.the lock is manufactured in brass or stainless steel making it ideal for use in harsh or corrosive environments. Operation The D lock range is used for interlocking electrical control cubicles and distribution panels. D multi key panel door interlock, exchange key condition 1 Key is free, while key is 2 Insert and turn key, then turn 3 trapped and the catch is trapped. key to release catch and then release key. Key is free, key is trapped while catch is released. 1. While the catch is trapped in the mechanism, key is trapped and key is free. The door is locked closed through the trapped catch. 2. Inserting and turning key in the bolt interlock enables the release of key and the release of the catch. This will trap key into the lock. 3. Key is used as the personnel key and taken to the machine area. Key stays trapped as long the catch is released and key is free. The D panel door interlock is available with as rear or front entry mounted catch. The catch is available as standard catch for well aligned doors or as MS catch for misaligned doors. U-D-001-E Issue 1 1 of 6

D Operation The D lock range is used for interlocking electrical control cubicles and distribution panels. D multi key panel door interlock, double key condition 1 oth keys, and are free, 2 Insert and turn both keys 3 catch is trapped. to release catch. Keys are trapped, catch is released. 1. While the catch is trapped, both keys and are free. The door is locked closed through the trapped catch. 2. Inserting and turning both keys in the D bolt interlock enables you to release the catch unlocking the door. This will trap both keys into the lock. 3. The keys stay trapped as long as the catch is released. The D panel door interlock is available with as rear or front entry mounted catch. The catch is available as standard catch for well aligned doors or as MS catch for misaligned doors. U-D-001-E Issue 1 2 of 6

D Usage The D panel door interlock should be used for interlocking electrical control cubicles and distribution panels. The D lock is not designed for security purposes, such as a safe or external access to a building. No hazardous substances were used in the manufacture of this product. The product can be disposed of in standard waste. Installation The housing of the D panel door interlock should normally be mounted to a panel using suitable fasteners (please refer to drawing on page 4 for more details). IMPORTNT: The interlock should be mounted using anti-tamper fasteners to prevent unauthorised removal. The D Panel Door Interlock must be installed by a competent and qualified person who has read and understood these instructions. Please retain this document in your technical file. Maintenance Periodic visual checks should be carried out by the site manager / safety officer. Do not lubricate lock barrel with oil or grease, use CK Dry Powder Graphite if necessary. In case of defects beeing detected please contact your nearest Castell Support Department for further actions. Please see Contact section for contact details. U-D-001-E Issue 1 3 of 6

D Technical Data Temperature rating Type of mounting Weight Material MTTF Certification Minimum: -40 C [-40 F] ice free for Q & F Type Maximum: 107 C [224,6 F] for Q Type/140 C [284 F] for F Type Surface mount using suitable fasteners (please refer to drawing on page 4 for more details) 1,2 kg rass/stainless steel vailable on request pplication Castell D multi key panel door interlocks are used as a part of a safety system, typically in machine guarding applications as in the below example. The power supply to the system is switched on and the access door to the hazardous area is locked closed. The removal of the isolation key in the KSS20, changes the switch contacts provided for electrical supply to the electrical supply to the LV panel from closed to opened. This key is then used to unlock the door by inserting key in the D panel door interlock and releasing the trapped personnel key and then the catch. This will trap the isolation key in the D interlock. The release key is taken by the personnel to the machine area. The power cannot be switched on until the personnel key is returned, the door is closed, the catch is trapped in the D panel door interlock and the isolation key returned to the KSS20. KSS20 D Panel Door Interlock EC-Declaration We, the manufacturers, declare that the components, detailed herein and placed on the market, comply with all the essential health and safety requirements applying to them. Empowered signatory: Mr T.C. Whelan Managing Director U-D-001-E Issue 1 4 of 6

D Drawing Dimensions: in mm Note: For safe mounting, use security screws D, front of board mount, exchange key condition, form 1 D, back of board mount, exchange key condition, form 1 U-D-001-E Issue 1 5 of 6

D Order Information Product Type 1 2 3 4 5 6 7 8 Part Number D - - - - - - - Example D - FS - F - 1S - E - RE - STD - 4 Isolation Key Symbol (exchange key condition) 9 or 10 or Primary Key Symbol (double key condition) Personnel Key Symbol (exchange key condition) Secondary Key Symbol (double key condition 1 Lock portion type FS (1) / Q (1) 2 Material = rass (standard) 3 Mounting P = Panel mount (back of board) / F = Front of board mount 4 Secondary lock portion(s) 5 Key condition 1S / 2S / 3S / 4S / 5S or 6S = 1 / 2 / 3 / 4 / 5 or 6 secondary lock portions respectively E = Exchange key condition / D = Double key condition (simulataneous removal of all keys) 6 Catch entry RE = Rear entry / FR = Front entry 7 Catch type 8 Form 1 / 2 / 3 / 4 (2) STD = standard catch, use for well aligned dors / MS = catch with spring, use for misaligned doors 9 10 Lock portion symbol: Isolation key (for exchange key condition) Primary key (for double key condition, lock next to the catch) Lock portion symbol: Personnel key (for exchange key condition) Secondary key (for double key condition) FS (1) up to 3 characters / Q (1) up to 6 characters FS (1) up to 3 characters / Q (1) up to 6 characters (1) F - Lock style Q - Lock style Up to 3 characters Up to 6 characters (2) Form 1 2 3 4 Contact Information Special construction available upon enquiry Castell Safety International Ltd. The Castell uilding 217 Kingsbury Road London, England NW9 9PQ Castell Safety International Ltd. Oskar-Jäger-Strasse 137 50825 Köln Germany Castell Interlocks Inc. Suite 800 150 N Michigan venue, Chicago, Illinois 60601 US Castell Safety China uilding 1, No. 123, Lane 1165, Jindu Road, Minhang District, Shanghai 201108, China. t: +44 (0) 20 8200 1200 f: +44 (0) 20 8905 9378 e: uksales@castell.com t: +49 (0) 221 1694 794 f: +49 (0) 221 1694 795 e: vertrieb@castell.com t: +1.312.360.1516 f: +1.312.268.5174 e: ussales@castell.com t: +86 21 61519023 f: +86 21 61519030 e: chinasales@castell.com U-D-001-E Issue 1 6 of 6