Split Air Conditioner

Similar documents
Split Air Conditioner

Split Air Conditioner

Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC

Fixed Speed Split Room Air Conditioner Installation Manual KSE26CRC, KSE26HRC, KSE35CRC, KSE35HRC, KSE53HRC, KSE62HRC, KSE70CRC, KSE70HRC, KSE88CRC

Split Air Conditioner. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

Split Air Conditioner

Split Air Conditioner

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

ALICE HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL

USER'S MANUAL SYMPHONY SERIES ASH-09AISR, ASH-09AISB, ASH-09AISW ASH-13AISR, ASH-13AISB, ASH-13AISW

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

INVERTER SPLIT - TYPE

Split Air Conditioner

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

ROOM AIR CONDITIONER INSTALLATION MANUAL

Notices for installation

Choosing the installation site. Installation. 07 Choosing the installation site

Split Air Conditioner

HEAT PUMP INSTALLATION MANUAL

Split Air Conditioner

Split Air Conditioner

GENERAL INFORMATION CONTENTS

OWNER S MANUAL ASH-09CS ASH-12CS SLIM SERIE. Before operating the unit please carefully read this manual.

Owner s Manual. Wall Mounted Unit. Models LIMI-12 / LIMO-12 LIMI-18 / LIMO-18 LIMI-24 / LIMO-24

Split Inverter Air Conditioner

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

36,000 Btu/hr Mini Split Air Conditioner

CCH mini-splits -13 SEER

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Split Air Conditioner. Model: GSA609AE GSA609AC GSA612AE GSA612AC GSA618AE GSA618AC GSA624AE GSA624AC

Split Air Conditioner

Split Air Conditioner

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

DAIKIN AIR CONDITIONER

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Air Conditioner. user installation & manual manual. imagine the possibilities

Split Air Conditioner

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

Installation manual. Split Type Room Air Conditioner

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

SPLIT -TYPE ROOM AIR CONDITIONER

USER'S MANUAL CAESARE SERIES ASH-28AC

OWNER S MANUAL. Split Air Conditioner AIR-MASTER Series MODELS: CH-S07RX4 CH-S09RX4 CH-S12RX4 CH-S18RX4 CH-S24RX4

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

UltraV Series Outdoor Units

Split Air Conditioner

SPLIT WALL-MOUNTED AIR CONDITIONER

OWNER S MANUAL. Split Air Conditioner IAPH301A / OAPH301A IAPH361A / OAPH361A

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

Room Air Conditioners

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Operation Area...1 Safety Precautions...2 Parts Name...3 Check Before Operation...4. Operation Method...5 Drainage Option...9

Models. Indoor Unit. Outdoor Unit

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Installation Manual. Floor-Standing Type FLOOR-STANDING TYPE AIR CONDITIONER

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

1. BEFORE INSTALLATION

Installation Manual Super-Slim Four-Way Cassette

Mini-Split Air Conditioner

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split Inverter Air Conditioner

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

OPERATION MANUAL AND INSTALLATION MANUAL

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

USER'S MANUAL CAESAR SERIES ASH-18AC PT, ASH-24AC PT

[FLARE CONNECTION TYPE] ATTENTION

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION

R410A SPLIT SERIES DC INVERTER

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

CENTRAL AIR CONDITIONER SPLIT SYSTEM

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

Wall Mounted Unit Owner s Manual

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Flex Match Series System-Outdoor Unit

PORTABLE AIR CONDITIONER

AIR CONDITIONER CONSOLE

Split-type Air-Conditioner

FLOOR TYPE AIR CONDITIONERS

Split-type Air-Conditioner

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram.

Wall Mounted Unit Owner s Manual

AMTCM4H4R24 AMTCM4H4R30 AMTCM4H4R36

Installation manual for room air conditioner

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series

Installation Manual. Ceiling & Floor Type CEILING & FLOOR TYPE AIR CONDITIONER

Transcription:

Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWC09AB-D3DNA2D GWC12AB-D3DNA2D GWC18AC-D3DNA2D GWC24AC-D3DNA2D GWH09AB-D3DNA2D GWH12AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D Thank you for choosing Residential Air Conditioners,please read this owner s manual carefully before operation and retain it for future reference.

CONTENTS Notices for installation...1 Installation dimension diagram...3 Install indoor unit...4 Install outdoor unit...7 Test operation and check after installation...9 Installation and Maintenance of Healthy Filter...10 Never attempt. Be sure to follow this instruction The physical product may differ from the drawing in this manual for different display. If there are some differences between them, please refer to the physical product as the standard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they are away from the appliance. Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

Notices for installation Caution 1. The unit should be installed only by authorized service center according to local or government regulations and in compliance with this manual. 2. Before installing, please contact with local authorized maintenance center. If the unit is not installed by the authorized service center, the malfunction may not be solved due to incovenient contact between the user and the service personnel. 3. When removing the unit to the other place, please firstly contact with the local authorized service center. 4.Warning: Before obtaining access to terminals, all supply circuits must be disconnected. 5.For appliances with type Y attachment, the instructions shall contain the substance of the following. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 6.The appliance must be positioned so that the plug is accessible. 7.The temperature of refrigerant line will be high; please keep the interconnection cable away from the copper tube. 8. The instructions shall state the substance of the following: This appliance is not intended for use by persons(including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Installation Site Instructions Proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where: strong heat sources, vapours, flammable gas or volatile liquids are emitted. high-frequency electro-magnetic waves are generated by radio equipment, welders and medical equipment. salt-laden air prevails (such as close to coastal areas). the air is contaminated with industrial vapours and oils. the air contains sulphures gas such as in hot spring zones. corrosion or poor air quality exists. 1. Installation Site of Indoor Unit The air inlet and outlet should be away from the obstructions. Ensure the air can be blown through the whole room. 2. Select a site where the condensate can be easily drained out, and where it is easily connected to outdoor unit. 3. Select a place where it is out of reach of children. 4. Select a place where the wall is strong enough to withstand the full weight and vibration of the unit. 5. Be sure to leave enough space to allow access for routine maintenance. The installation site should be 98 3/7 inch or more above the floor 1

Notices for installation 6. Select a place about 3.3ft or more away from TV set or any other electric appliance. 7. Select a place where the filter can be easily taken out. 8. Make sure that the indoor unit is installed in accordance with installation dimension instructions. 9. Do not use the unit in the laundry or by swimming pool etc. Note: Installation Site of Outdoor Unit 1. Select a site where noise and outflow air emitted by the unit will not annoy neighbors. 2. Select a site where there is sufficient ventilation. 3. Select a site where there is no obstruction blocking the inlet and outlet. 4. The site should be able to withstand the full weight and vibration. 5. Select a dry place, but do not expose the unit to direct sunlight or strong wind. 6. Make sure that the outdoor unit is installed in accordance with the installation instructions, and is convenient for maintenance and repair. 7. The height difference between indoor and outdoor units is within16.4ft, and the length of the connecting tubing does not exceed 32.8ft. 8. Select a place where it is out of reach of children. 9. Select a place where the unit does not have negative impact on pedestrians or on the city. Safety Precautions for Electric Appliances 1. A dedicated power supply circuit should be used in accordance with local electrical safety regulations. 2. Don't drag the power cord with excessive force. 3. The unit should be reliably earthed and connected to an exclusive earth device by the professionals. 4. The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload. 5. The minimum distance between the unit and combustive surface is 4.9ft. 6. The appliance shall be installed in accordance with national wiring regulations. 7. An all-pole disconnection switch with a contact separation of at least 9.8ft in all poles should be connected in fixed wiring. Make sure the live wire, neutral wire and earth wire in the family power socket are properly connected. There should be reliable circuit in the diagram. Inadequate or incorrect electrical connections may cause electric shock or fire. Earthing Requirements 1. Air conditioner is type I electric appliance. Please ensure that the unit is reliably earthed. 2. The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may cause electric shock. 3. The earth resistance should accord to the national criterion. 4. The power must have reliable earthing terminal. Please do not connect the earthing wire with the following: 1 Water pipe 2 Gas pipe 3 Contamination pipe 4 Other place that professional personnel consider is unreliable 5. The model and rated values of fuses should accord with the silk print on fuse cover or related PCB. 2

Installation dimension diagram Installation dimension diagram Indoor unit Space to the ceiling 6inch Above Space to the wall 6inch Above 6inch Above Space to the wall 118 inch 98 Above inch Above Space to the floor Air outlet side Outdoor unit Space to the obstruction 20inch above Air inlet side 12inch above 12inch above Space to the wall 79inch above Air outlet side 20inch above Space to the wall 3

1 Installation of Indoor Unit Installation of Mounting Plate 1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of condensate. 2.Fix the mounting plate on the wall with screws. 3.Be sure that the mounting plate has been fixed firmly enough to withstand about 132.3 lb. Meanwhile, the weight should be evenly shared by each screw. 09K 12K UNIT: Wall the wall 6inch above 6 1/6 33 3/4 23 5/6 3 3/4 Space to the wall 6inch above Wall 11 1/7 Ø2 1/6 Left (Rear piping hole) 3 4/7 1/3 1 1/9 4 2/7 Ø2 1/6 Right (Rear piping hole) 37 1/4 4 1/3 27 1/3 5 3/5 18K UNIT: 11 4/5 Ø2 1/6 1 2 3/4 3 1/7 Ø2 1/6 1/3 1 1/6 46 6 8/9 27 8 1/5 6 2/5 24K UNIT: 13 Ø2 3/4 3 7 Ø2 3/4 1 4/7 1 1/4 Unit:inch Fig.5 Drill Piping Hole Indoor 1.Slant the piping hole (Ф2 1/6 or Ф2 3/4) on the wall sl ightly downward Wall pipe to the outdoor side. 2.Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole. Outdoor Seal pad Ф2 1/6 or Ф2 3/4 4

1. Installation of Indoor Unit Installation of Drain Hose Connect the drain hose to the outlet pipe of the indoor unit. Bind the joint with rubber belt. 2. Put the drain hose into insulating tube. outlet pipe of indoor unit outlet pipe of drain hose indoor unit rubber belt outlet pipe of drain hose indoor unit 3. Wrap the insulating tube with wide rubber belt to prevent the shift of insulating tube. Slant the drain hose downward slightly for smooth drainage of condensate. rubber belt insulating tube rubber belt outlet pipe of indoor unit Note: The insulating tube should be connected reliably with the sleeve outside the outlet pipe. The drain hose should be slanted downward slightly, without distortion, bulge or fluctuation. Do not put the outlet in the water. bulge connected insulating tube distortion Flooded Connecting Indoor and Outdoor Electric Wires 1.Open the front panel. 2.Remove the wiring cover as shown in Fig 6. 3.Make the power connection cord and pass through the hole at the back of indoor unit. 4.Reinstall the cord anchorage and wiring cover. Wiring cover 5.Reinstall the front panel. brown yellowgreen Fig.6 NOTE: outdoor unit connection All wires between indoor and outdoor units must be connected by the qualified electric contractor. Electric wires must be connected correctly. Improper connection may cause malfunction. Tighten the terminal screws securely. After tightening the screws, pull the wire slightly to confirm whether it's firm or not. Make sure that the electric connections are earthed properly to prevent electric shock. Make sure that all wiring connections are secure and the cover plates are reinstalled properly. Poor installation may cause fire or electric shock. 5

Installation of Indoor Unit Installation of Indoor Unit The piping can be output from right, right rear, left or left rear. 1. When routing the piping and wiring from the left or right side of indoor unit, cut off the tailings from the chassis when necessary(as shown in Fig.7) ⑴ Cut off tailing 1 when routing the wiring only; ⑵ Cut off tailing 1 and tailing 2 when routing both the wiring and piping. 2. Take out the piping from body case; wrap the piping, power cords, drain hose with the tape and then make them pass through the piping hole. (As shown in Fig.8) 3. Hang the mounting slots of the indoor unit on the upper hooks of the mounting plate and check if it is firm enough. (As shown in Fig.9) 4. The installation site should be 98 3/7 inch or more above the. floor Fig.7 Right Tailing 2 Gas side piping Tailing 1 insulation 右后 Right rear Fixing hook Mounting plate Fig.9 External connection Gas side piping electric wire Liquid side piping Finally wrap it with tape Water drainage pipe Left Left rear Fig.8 Liquid side Piping insulation Mounting plate Installation of Connection Pipe 1. Align the center of the pipe flare with the related valve. 2. Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench by referring to the following: Indoor unit piping Tube diameter Tightening torque,approximate (N m) Ф6.35(1/4 ) 14~18N m(140-180kgf.cm) Ф9.52(3/8 ) 34~42N m(340-420kgf.cm) Spanner Ф12.7(1/2 ) 49~61N m(490-610kgf.cm) Ф15.88(5/8 ) 68~82N m(680-820kgf.cm) Taper nut Piping Torque wrench NOTE: Connect the connection pipe to indoor unit at first and then to outdoor unit. Handle piping bending with care. Do not damage the connection pipe. Ensure that the joint nut is tightened firmly, otherwise, it may cause leakage. 6

Installation of Outdoor Unit Electric Wiring 1. Remove the handle on the right side plate of outdoor unit. 2. Take off wire cord anchorage. Connect and fix power cord to the terminal board. Wiring should fit that of indoor unit. 3. Fix the power cord with wire clamps and then connect the the corresponding connector. 4. Confirm if the wire has been fixed properly. 5. Reinstall the handle. NOTE: Incorrect wiring may cause malfunction of spare part. After the wire has been fixed, ensure there is free space between the connection and fixing places on the lead wire. Schematic diagram being reference only, please refer to real product for authentic information. Sketch map of power connection wire: Cable-cross board for 9k 12k unit Power connection wire for 18K 24K unit Indoor unit connection Power cord N(1) 2 3 L1 blue black brown brown L1 L2 L2 blue POWER G Wire hole yellowgreen yellowgreen Air purging method: Air purging Air purging method Length of connection pipe Refrigerant charging amount Not longer than 24.6ft Nameplate value Use vacuum pump Nameplate value +20g/m (for 9k 12k 18k heat pump unit 24.6~65.6ft Nameplate value +15g/m (for 18k 24k cool only unit Nameplate value +50g/m (for 24k heat pump unit add 15g/20g/50g of refrigerant for additional 1m of pippe length Use vacuum pump (Note: R410A refrigerant special vacuum pump should be Manifold valve applied for R410A unit.) 1. Connect the charging hose of manifold valve to charging Multimeter port of low-pressure valve. Both high-pressure valve and low-pressure valve must be tighten up). -76cm Hg Lo handle Piezometer Hi handle 2. Connect joint of charging hose to vacuum pump. 3. Fully open Lo (low pressure)handle of manifold valve and start the vacuum pump for vacuum pumping. Charging hose Gas valve Charging hose Vacuum pump Liquid 4. Usually the vacuum pumping time of 2600W AC is about valve 15min. The vacuum pumping time of 5000W AC is about 20min. The vacuum pumping time of 7200W AC is about 30min. Make sure the pressure is -1.0X105pa (-76cmHg). When vacuum pumping is finished, close Lo(low pressure) handle of manifold valve completely to stop the vacuum pump. 7

Installation of Outdoor Unit 5. Maintain the pressure for a while after finishing vacuum pumping to see if there is leakage of the system. Usually the pressure maintenance time of the air conditioner above 5000W is 5min and the pressure maintenance time of the air conditioner below 5000W is 3min. During pressure maintenance period, the rebound of pressure should not exceed 0.005Mpa (0.11lb). 6. After finishing vacuum pumping, open the liquid valve slightly to release air in order to balance the system pressure and present air inlet when removing the hose. Fully open high-pressure valve and low-pressure valve after removing the hose. 7. Tighten bonnets of high-pressure valve, low-pressure valve and charging port. Leakage test Apply soap water to check whether the joints are leaky. Leak detector can also be applied for leakage test. Leak detection point of indoor unit Leak detection point of outdoor unit Outdoor Condensate Drainage (only for Heat pump unit) During heating operation, the condensate and defrosting water should be drained out reliably through the drain hose. Install the outdoor drain connector in a Φ1 inch hole on the base plate and attach the drain hose to the connector so that the waste water formed in the outdoor unit can be drained out.the hole diameter 25 must be plugged. Drain-water hole Bottom frame Drain plug Drain connecter Hose (available commercially, inner dia. 16mm) Whether to plug other holes will be determined by the dealers according to actual conditions. 8

Check after Installation and Operation Test Check after Installation Items to be checked Has the unit been fixed firmly? Have you done the refrigerant leakage test? Is thermal insulation sufficient? Possible malfunction The unit may drop, shake or emit noise. It may cause insufficient cooling(heating). It may cause condensation. Is water drainage satisfactory? It may cause water leakage. Is the voltage in accordance with the rated voltage marked on the nameplate? Is the electric wiring or piping connection installed correctly and securely? Has the unit been securely earthed? Is the power cord specified? Is the inlet or outlet blocked? It may cause electric malfunction or damage the unit. It may cause electric malfunction or damage the parts. It may cause electrical leakage. It may cause electric malfunction or damage the parts. It may cause insufficient cooling(heating). Is the length of connection pipes and refrigerant capacity recorded? The refrigerant capacity is not accurate. Operation Test 1.Before Operation Test (1)Do not switch on power before installation is finished completely. (2)Electric wiring must be connected correctly and securely. (3)Cut-off valves of the connection pipes should be opened. (4)All the impurities such as scraps and thrums must be cleared from the unit. 2.Operation Test Method (1)Switch on power and press "ON/OFF" button on the wireless remote controller to start the operation. (2)Press MODE button to select the COOL, HEAT (Not available for cooling only unit), FAN to check whether the operation is normal or not. 9

Installation and Maintenance of Healthy Filter(Optional) Installation of Healthy Filter 1. Lift up the front panel from its two ends, as shown by the arrow direction, and then remove the air filter. (as shown in Fig.a) Fig. a 2. Attach the healthy filter onto the air filter, (as shown in Fig.b).. Fig. b Air filter Healthy filter 3. Install the air filter properly along the arrow direction in Fig.c, and then close the panel. Fig. c Cleaning and Maintenance Remove the healthy filter and reinstall it after cleaning according to the installation instruction. Do not use brush or hard objects to clean the filter. After cleaning, be sure to dry it in the shade. Service Life The general service life for the healthy filter is about one year under normal condition. As for silver ion filter, it is ineffective when its surface becomes black (green). This supplementary instruction is provided for reference to the unit with healthy filter. If the graphics provided herein are different from the actual product, please refer to the actual product. The quantity of healthy filters is based on the actual delivery. 10

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com 66129911448