Qualification Test Report LC Duplex Adapter For LC Cutouts

Similar documents
Apr06 Rev A

Jan07 Rev B

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Jul07 Rev C

/Mar/2014 Rev A

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Mar11 Rev B

MT-RJ Optical Fiber System Field Testing

Jan05 Rev A EC

Jun08 Rev A

Two Circuit Heavy Duty Burner Connector

Jun08 Rev C

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Mar11 Rev C

ETSI TS V1.2.1 ( )

Draft ES V1.1.1 ( )

ETSI TS V1.2.1 ( )

Fibrlok II 2529 Universal Optical Fiber Splice

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Cat 6 Shielded Patch cords

/Oct/2014 Rev E

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Cat 6 Unshielded Patch cords

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Product Specification Qualification Test Report

ITU-T L.404. Field mountable single-mode optical fibre connectors

/Oct/2014 Rev B

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

FiberExpress Solutions

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

APR 17 Rev A

USB 3.0 Plug & Receptacle

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Fiber Optic Patch Cord and Pigtails

4120 Fire Alarm Network Reference

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

Fiber Optic Distribution Cables (6-144 Fibers)

Qualification Test Report 1/Jul/2005 Rev. A

Special Provision No. 683S28 December 2017

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

JUL 18 Rev A1

FEB. 17 Rev. A1

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

Connections You Can Count On.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Fiber Optic Products Catalog

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

STANDARD CONFORMANCE

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

SECTION TESTING OF FIBER OPTIC CABLES

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

NG4access ODF Platform Standard Chassis Installation Manual

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Inverted Through Board Surface

Vibration tests on a TNAML Luminaire

SECTION TESTING OF FIBER OPTIC CABLES

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Fibre (TIA) Field Test Specification

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

MicrOTDR. Optical Fault Locator. User Manual

AV6416 OTDR. Product Overview: Main Features:

Certified Fibre Optic Specialist - Testing

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

INTERNATIONAL STANDARD

Applications Engineering Notes

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

ENCIRCLED FLUX (EF) TEST SOLUTIONS

This is a preview - click here to buy the full publication

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

Transcription:

Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their conformance to Tyco Electronics Product Specification 108-2358, which contains a subset of tests from the small form factor connector requirements specified in Telcordia Technologies Specification GR-326-CORE, Issue 3, General Requirements for Singlemode Optical Connectors and Jumper Assemblies. 1.2. Scope This report covers the optical and mechanical performance of singlemode LC Duplex Adapter for LC Cutouts manufactured by Tyco Electronics, Fiber Optics Business Unit. Testing was performed between March 2008 and May 2008. The test file number for this testing is B090701-002 1.3. Conclusion The LC Duplex Sr-Jr Singlemode Adapters for LC Cutouts, listed in paragraph 1.5, meet the requirements of Tyco Electronics Product Specification 108-2358 and the optical and mechanical small form factor performance requirements at 1310 and 1550 nm wavelengths for the tests listed in Figure 2, which are a subset of Telcordia Technologies GR-326-CORE, Issue 3. LC Duplex Sr-Sr Adapters for LC Cutout are assumed to be qualified by similarity to LC Duplex Sr-Jr Adapters for LC Cutout. LC Duplex Multimode Adapters for LC Cutout are assumed to be qualified by similarity to LC Duplex Singlemode Adapters for LC Cutout. 1.4. Product Description Tyco Electronics LC Duplex Adapters are used with panels with LC Cutouts to mount and connect LC fiber optic connectors used in data communication and telecommunication networks and equipment. 2009 Tyco Electronics Corporation Harrisburg, PA All International Rights Reserved * Trademark Indicates change 1 of 8 LOC B

1.5. Test Specimens Test specimens were manufactured using standard manufacturing processes and are representative of current production. A specimen consisted of one channel of a single Sr/Jr LC Duplex Adapter. Two reference quality test leads, LC to FC/APC, were connected to either channel A or channel B of the adapter. The transmit test leads were connected to the Jr.-side of the adapter and the receive test leads were connected to the Sr.-side of the adapter. Component Description Test Group 1 Adapter Type LC Duplex Sr/Jr Singlemode Adapter PN 1985150-1 Test Cable Assembly PN (see Note) 1695474-1 Test Cable Length (m) 10 Test Specimens Required 15 Test Cables Required 30 Control Cable Required No NOTE Test cable assemblies were reference quality. Figure 1 1.6. Qualification Test Sequence Test Group (a) Test or Examination 1 Test Sequence (b) Visual and mechanical inspection 1 (attenuation) 2,10 Reflectance 3,11 Vibration 4 Flex 5 Twist 6 Proof 7 Transmission with applied load 8 Durability 9 NOTE (a) See paragraph 1.5. (b) Numbers indicate sequence in which tests are performed. Figure 2 Rev B 2 of 8

2. SUMMARY OF TESTING 2.1. Visual and Mechanical Inspection All specimens submitted for testing were representative of normal, current production lots, and were inspected and accepted by the Product Assurance Department of the Fiber Optics Business Unit. 2.2. Initial Optical Performance All initial loss and reflectance measurements were recorded and met the specification requirements for New Product. and Reflectance were measured at both 1310 and 1550 nm. See Figure 3 for New Product and Reflectance Measurements., Mean and Reflectance - Requirements and Actual for New Product (db) W avelength (nm) Mean Requirement Reflectance Mean Actual Reflectance 1310 0.07 0.17-48 0.20 0.40-40 1550 0.06 0.12-50 Figure 3 Rev B 3 of 8

2.3., Increase, Mean, Reflectance, and Reflectance Increase - All Remaining Tests 501-683 All, Increase, Mean, Reflectance, and Reflectance Increase measurements met the specification requirements for each test. All measurements were recorded at both 1310 and 1550 nm. Values shown in Figure 4 represent, Increase, Mean, Reflectance, and Reflectance Increase., Increase, Mean, Reflectance, and Reflectance Increase Results (db) Test Condition Actual Actual Requirement Criteria 1310 nm 1550 nm (db) Met? (db) (db) Mean 0.3 0.07 0.04 0.5 0.19 0.12 Vibration Increase 0.3 0.06 0.03 Yes Reflectance -40-48 -49 Reflectance Increase 5 1 1 Mean 0.3 0.03 0.03 0.5 0.09 0.08 Flex Increase 0.3 0.04 0.03 Yes Reflectance -40-52 -52 Reflectance Increase 5 1 1 Mean 0.3 0.03 0.03 0.5 0.09 0.09 Twist Increase 0.3 0.04 0.01 Yes Reflectance -40-52 -52 Reflectance Increase 5 0 0 Mean 0.3 0.04 0.02 0.5 0.09 0.09 Proof, 0 degrees Increase 0.3 0.02 0.01 Yes Reflectance -40-52 -52 Reflectance Increase 5 1 0 Mean 0.3 0.04 0.04 0.5 0.12 0.13 Proof, 90 degrees Increase 0.3 0.09 0.06 Yes Reflectance -40-51 -50 Reflectance Increase 5 3 4 Transmission with Applied Load, 0 degrees See Note (b) Transmission with Applied Load, 90 degrees See Note (b) Durability See Note (c) Increase 0.5 0.04 0.04 Reflectance -40-51 -52 Yes Reflectance Increase 5 1 2 0.51 Increase 0.5 0.09 See Note (a) Yes Reflectance -40-51 -52 Reflectance Increase 5 0 0 Mean 0.3 0.04 0.04 0.5 0.19 0.14 Increase 0.3 0.15 0.11 Reflectance -40-42 -43 Reflectance Increase 5 5 5 Yes 90% NOTE (a) (b) (c) In the past Telcordia has applied a measurement error allowance of 2 db for reflectance measurements and 0.05 db for loss measurements. This was based on the observed repeatability of measurements on internal standards during testing. Optical performance requirements apply during the test, while the load is applied. After a cleaning interval, 90% must meet the requirements. Figure 4 Rev B 4 of 8

2.4. Vibration 2.5. Flex 2.6. Twist There was no evidence of physical damage to the adapter or test cable., Increase, Mean, Reflectance and Reflectance Increase measurements met the specified limits, as stated in Figure 4, before and after testing. Optical performance was measured at both 1310 and 1550 nm. There was no evidence of physical damage to the adapter or test cable., Increase, Mean, Reflectance and Reflectance Increase measurements met the specified limits, as stated in Figure 4, before and after testing. Optical performance was measured at both 1310 and 1550 nm. There was no evidence of physical damage to the adapter or test connector or cable., Increase, Mean, Reflectance and Reflectance Increase measurements met the specified limits, as stated in Figure 4, before and after testing. Optical performance was measured at both 1310 and 1550 nm. 2.7. Proof, 0 and 90 Degrees There was no evidence of physical damage to the adapter or test cable during or after test., Increase, Mean, Reflectance and Reflectance Increase measurements met the specified limits, as stated in Figure 4, before and after testing. Optical performance was measured at both 1310 and 1550 nm. 2.8. Transmission with Applied Load, 0 and 90 Degrees There was no evidence of physical damage to the adapter or test cable assembly during or after test. Increase, Reflectance and Reflectance Increase measurements met the specified limits, as stated in Figure 4, before, during, and after testing. Optical performance was measured at both 1310 and 1550 nm. 2.9. Durability There was no evidence of physical damage to the adapter or test cable assembly due to durability testing., Increase, Mean, Reflectance and Reflectance Increase measurements met the specified limits as stated in Figure 4, before, during, and after testing. Optical performance was measured at both 1310 and 1550 nm. Rev B 5 of 8

2.10. Final Optical Performance with Reference Quality Test Leads At the completion of the test sequence, all final attenuation and reflectance measurements of the adapter (between reference quality test leads) met the specification requirements. No significant change was observed between initial adapter performance recorded before the first test and final adapter performance measured after the last test in the sequence. Attenuation and reflectance were measured at both 1310 nm and 1550 nm. See Figure 5., Mean and Reflectance - Requirements and Actual for End of Test (db) W avelength (nm) Mean Requirement Reflectance Mean Actual 1310 0.04 0.10 0.20 0.40-40 1550 0.03 0.08 3. TEST METHODS Figure 5 Reflectance All optical measurements were performed with the utilization of a benchtop singlemode test system. This measurement facility is compliant with TIA/EIA-455-20A. and Reflectance were measured at both 1310 and 1550 nm, unless otherwise specified. Following installation of the specimens, sequential testing was performed. 3.1. Visual and Mechanical Inspection Product drawings and inspection plans were used to examine the specimens visually and functionally. 3.2. (Attenuation) All singlemode loss was measured in accordance with FOTP-171, Method D3 processes. The initial optical power through each of the launch connector fiber paths was measured. The receive connector assembly was then mated and optical power measured from the receive side fiber. was calculated by taking the difference between these 2 measurements. The receive fiber was then connected to the optical test equipment. Optical power was recorded as a reference to calculate loss increase during/after subsequent tests. Optical power readings were compensated by changes in a source monitor cable. 3.3. Increase (Attenuation Increase) Increase was calculated by taking the difference between the initial measurement and the measurement during or after each test. increase represents a change in loss that results from a decrease in optical power (degraded performance). Optical power readings were compensated by changes in the source monitor cable. 3.4. Reflectance Reflectance was measured in accordance with EIA/TIA-455-107A, Method A. A single measurement was recorded for reflectance. Reflectance was measured initially and during/after each test evaluation as required by the specification. -51 Rev B 6 of 8

3.5. Reflectance Increase Increase in reflectance was calculated by taking the difference between the initial measurement and the measurement during or after each test. Reflectance increase is a change in reflectance that represents degraded performance. 3.6. Vibration 3.7. Flex Specimens were subjected to sinusoidal vibration, having a simple harmonic motion with amplitude of 1.5 mm [0.06 in] peak-to-peak. The vibration frequency was varied uniformly between the limits of 10 and 55 Hz for 2 hours in each of the 3 mutually perpendicular directions, at a rate of 45 Hz per minute. Optical performance was recorded before and after exposure in each plane with the specimens in place on the vibration machine. Specimens were subjected to 100 cycles of cable flexing. Specimens were tested at a rate of 25 cycles per minute. A 7.5 cm [3 in] mandrel was used to apply a tensile load of 0.6 kg [1.3 lbf] to jacketed cable on the Sr end of the adapter at an approximate distance of 25 cm [10 in] from the connector boot. The flex arc was ± 90 degrees from a vertical position. Optical performance was measured before and after test with the load removed. 3.8. Twist Specimens were subjected to 10 cycles of twist. Specimens were manually tested at a rate less than 30 cycles per minute. A 7.5 cm [3 in] diameter mandrel was used to apply a tensile load of 1.35 kgf [3.0 lbf] to jacketed cable on the Sr end of the adapter at an approximate distance of 25 cm [10 in] from the connector boot. The twist motion for each cycle was ± 2.5 revolutions about the axis of optical transmittance. Optical performance was measured before and after test with the load removed. 3.9. Proof Axial and 90 degree side loads were manually applied by wrapping the test lead cable around a 7.5 cm [3 in] diameter mandrel at an approximate distance of 25 cm [10 in] from the connector boot. Specimens were subjected to a 4.5 kg (10 lb) axial load on the Sr end of the adapter for a 5 second duration for Small Form Factor Connectors. The load was removed and optical measurements taken after 20 seconds to allow the specimens to normalize. Subsequently, the specimens were subjected to the 90 degree applied side load requirement of 1.5 kg (3.3 lb) for Small Form Factor Connectors. The load was removed and optical measurements taken after 20 seconds to allow the specimens to normalize. Rev B 7 of 8

3.10. Transmission with Applied Tensile Load Attenuation and reflectance were measured before the start of the test. An adapter was secured to the test fixture. The first load of 0.25 kg [0.55 lb] was manually applied on the Sr end of the adapter at 0 degrees by wrapping the cable around a 7.5 cm [3 in] diameter mandrel at an approximate distance of 25 cm [10 in] from the connector boot. Attenuation and reflectance were recorded after holding the load for a minimum of 20 seconds, or until stability was reached. The load was removed and the test was repeated with the next load and angle. During test measurements were recorded for each of the 8 load and angle combinations shown in Figure 4. Final attenuation and reflectance were recorded a minimum of 20 seconds after the last load was removed. The test criteria shown in the table below follows Telcordia GR-326-CORE Table 4-10 requirements for small form factor, media type I, except for the 135 degree load application. Small Form Factor Required Tensile Loads for Transmission with Applied Load Test Order Required Load Kilogram Pound Angle 1 0.25 0.55 0 2 0.17 0.37 90 3 0.7 1.54 0 4 0.47 1.0 90 5 1.5 3.3 0 6 1.0 2.2 90 7 2.0 4.4 0 8 1.3 2.9 90 3.11. Durability, 200 Cycles GR-326 Table 4-10 The plug on the receive end (Sr.-side of the adapter) was subjected to 200 cycles of durability. Half of the test specimens' test leads were connected to channel A. The remaining test specimens' test leads were connected to channel B. The simplex plug on the receive end (Sr.-side of the adapter) was mated and unmated for all specimens during durability cycling. Specimens were mounted at 1.8 m [6 ft], 1.4 m [4.5 ft] and 0.9 m [3 ft] above the floor per GR-326-CORE procedure. Specimens were manually cycled at a rate not in excess of 300 cycles per hour. Attenuation and reflectance were recorded after one sided cleaning at 25, 75, 125 and 175 cycles. Attenuation and reflectance were recorded after two sided cleaning at 50, 100, 150 and 200 cycles. If specimens did not meet optical criteria after any of the cleaning intervals, additional cleanings of the reference quality test leads were permitted. Rev B 8 of 8